| 1 | Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed . |
| 2 | M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed . |
| 3 | All as per item No 02 above but except bricks. |
| 4 | M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and directed . |
| 5 | Taking down cement / Grit plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed |
| 6 | M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed |
| 7 | M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl WPC as per user manual complete all as specified and directed. |
| 8 | M&L for rendering 10mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed. . |
| 9 | M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed . |
| 10 | M&L for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed . |
| 11 | M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed . |
| 12 | M&L for two coat of Acrylic smooth exterior emulsion paint over one coat of acrlic primer incl one layer of 1mm thick wall care compound of altek/birla putty for exterior/interior on old scraped wall/ceiling surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed . Note : Colour and make as approved by EIC/GE. |
| 13 | M&L for preparation of old surfaces by removal of existing treatment and applying two coats of distemper oil emulsion on wall/ceiling over one coat of primer incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed . |
| 14 | M&L for preparation of old surfaces by removal of existing treatment and applying one coats of distemper oil emulsion on wall/ceiling over one coat of primer incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed . |
| 15 | M&L for non skid ceramic coloiured tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling tiles etc complete all as specified and directed. |
| 16 | All as per item No 16 above but area of each tile exe 0.11 sqm but n.exe 0.18 sqm, in floors & dado etc. |
| 17 | M& L for Glazed ceramic jointless light/coloured group of size 300/350mmx450/600mm, thickness not less than 6mm as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement and pigment to match, laid over and including 10mm thick plastering in cement mortar 1:4, incl dismantling tiles etc complete all as spd and directted. Note : shade & design as approved by EIC/GE complete all as specified. |
| 18 | M&L for Vitrified tiles light shade /dark shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling tiles etc complete all as specified and directed. |
| 19 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.laid, bedded and pointed in any mortar, complete all as specified and directed |
| 20 | M&L for Granite 18-20 mm thick (of any type ) (table runned and polished ) in floors steps , jamns, pillars,window-cills,cooking plateforms and vertical surfaces bedded and jointed with grey cement slurry and pointing in white ciment (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed |
| 21 | M&L rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed |
| 22 | M&L for marble 15-18 mm (green/any colour shade approved by EIC) thick over cement screed bed laid on 15 mm thick CM 1:6 and jointed with grey cement slurry mixed with pigment ot match the shade of the slab / staircase / steps,riser incl rubbing and polishing incl rounding to edge of marble and incl dismantling complete all as specified and directed. |
| 23 | M&L for 15 to 20 mm thick Kota stone slab flooring (Machine cut) of any size laid over and incl 20mm thick bedding layer in cement mortar 1:6 over neat cement slurry @ 3Kg/sqm over sub base , jointed and pointed in grey cement mixed with pigment to match the shade of slab including rubbing and polishing to achieve mirror finish complete as in flooring complete all as specified and directed |
| 24 | Dismantling wall and ceiling boards (fibre pulp insulation etc) or insulation boards, slabs, blankets any thickness, incl cover fillets complete all as specified and directed |
| 25 | S & F for 600x600mm plain board panel for ceiling 4.0 to 8.0 mm thk and incl necessary Gl/Alu frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre incl dismantling of walls and ceiling board any type complete all as specified and directed |
| 26 | M&L for PVC hollow panelling 5 to 8 mm thick on ceilling with necessary frame work in Design POPUP pattern and any colour approved by engr-in-charge, inclusive of fixing on to ceiling incl moulding end caps fixed with PVC sleeves and screws as required at site complete all as specified and directed |
| 27 | M&L in repair for PVC hollow wall panelling 7 to 8mm thick any colour/design approved by engr-in-charge, inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as required at site complete all as specified and directed |
| 28 | Removing plants / sherbs duct wall , junction with roots using herbicide chemical of existing brick or concrete for multistoried building at any storeyed and any height and match the surface with existing surface using 1:3 CM, completer all as specified and directed. |
| 29 | S&F for rotational moulded polyetheylene water storage tanks tripple layered (cylingrical verticlal with closed top) of 500 ltr capacity, hoisted and fixed in any position incl 20 mm dia ball float valve with aluminium fitting, GI nipple and any fitting ,dismantling existing water tank complete all as specified and directed. |
| 30 | S&F for rotational moulded polyetheylene water storage tanks tripple layered (cylingrical verticlal with closed top) of 1000 ltr capacity, hoisted and fixed in any position incl 20 mm dia ball float valve with aluminium fitting,GI nipple and any fitting , tank cover dismantling existing water tank complete all as specified and directed. |
| 31 | S&F for Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and re-fixing in position. (incl writing in white paint of 150mm size \\" Tank cleaning on dt _______ \\" complete all as specified and directed (a) Tank Capacit exc 250 Ltr but n exc 500 Ltr. |
| 32 | S&F for Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and re-fixing in position. (incl writing in white paint of 150mm size \\" Tank cleaning on dt _______ \\" complete all as specified and directed (a) Tank Capacit exc 500 Ltr but n exc 1000 Ltr. |
| 33 | S&F for Gun-metal globe or gate valves of 20mm bore , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. . |
| 34 | S&F for 20mm dia Nipple suitable for HDPE water tank.(Minimum weight 15mm-38gms/20mm 45gms /25mm- 65gms) complete all as specified and directed. |
| 35 | S&F 20 mm dia Unions brass to connect iron to polyethylene and fixed complete all as specified and directed |
| 36 | S&F stainless steel pegset of six suitable size of length etc, complete all as specified and directed |
| 37 | Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing or removed to store complete all as specified and directed. |
| 38 | S&F for GI tubing 15mm bore medium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required complete all as specified and directed |
| 39 | Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directed.. |
| 40 | S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed. |
| 41 | Taking down chowkhats or frames with shutters not exc. 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed |
| 42 | Taking down shutters of any description n exc 1 sqm each complete all as specified and directed |
| 43 | Taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed |
| 44 | S&F for 30mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed. |
| 45 | S&F for 2nd class H.W. glazed and skelton door shutters 35mm thick, open rebated and prepared to received glass/gauge etc (without sash bars) edges of framing plain, chamfered or rounded and mitred , beads for securing glass etc the size of member of shutter as specified in SSR part-I clause 8.23(b) and fitted to chowkahts incl stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads etc complete all as specified and directed |
| 46 | S & F solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube incl taking down old frame any type complete all as specified and directed. |
| 47 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be convered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and raials with suitabale PVC sheet beading, and jointed together with solvant cement, fixing in the frame at side as per specification and drawing incl 3Nos- 100mm Aluminium hinges for each shutter complete all as specified and directed . |
| 48 | S&F for MS butt hinges, medium weight, cold rolled mild steel 100mm long (ISI Marked) with welded or complete all as specified and directed. |
| 49 | S&F for aluminum anodized barrel tower bolts of extruded section 150mm long (ISI Marked) complete all as specified and directed. |
| 50 | S&F for aluminum handles cast type anodized 200mm long (ISI Marked) complete all as specified and directed. |
| 51 | S&F for 250mm long aluminium alloy, anodised, sliding door bolt of 16mm dia with hasp, staple (bolt type) and fixing clips of sheet, extruded sections and fixing bolts and sliding bolts of extruded sections complete all as specified and directed. |
| 52 | S&F in repair, 150 mm ordinay rat tail rod pattern springs incl roller and rabber plate fixed to chowkhats in repairs incl necessary welding if reqd. complete all as specified and directed. |
| 53 | M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface width or girth exc 10cm all as specified and directed. |
| 54 | M&L for two coats of synthetic enamel paint over a coat of pink primer on wooden new surfaces of any description over 10cm width or girth incl preparation of new surfaces complete all as specified and directed. |
| 55 | M&L for one coats of synthetic enamel paint on wooden surfaces of any description over 10cm width or girth including preparation of old surfaces complete all as specified and directed. |
| 56 | M&L for anodised aluminium framed work for door, window / vent (powder coated) aluminium with one or more rebated incl jointed cleat for fixing etc complete all as specified and directed |
| 57 | M&L for anodised aluminium powder coated door shutter , aluminium section weighting not less than 0.55kg/RM incl necessary 4.8mm th sheet glass ordinary quality / frosted glass or ACP sheet incl joining with cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, lock , 2 x 150mm aluminium handles, 3 x 100mm hinges aluminium, 2 x 150mm Aluminium tower bolts,1xdoor stoper,1xHydralic door closer with each shutter any type incl taking down complete all as specified and directed |
| 58 | M&L for anodised aluminium powder coated window and ventilator shutters, aluminium section weighting not less than 0.55kg/RM incl necessary 4.8mm th sheet glass ordinary quality glass/ frosted incl joining with cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, lock , 2 x 150mm aluminium handles, 3 x 100mm hinges aluminium, 2 x 150mm Aluminium tower bolts complete all as specified and directed . |
| 59 | S&F aluminium wire guard mesh of 4mm nominal dia of wire and average width of aperture 75 - 85mm and fixed with aluminium frame / staples complete all as specified and directed |
| 60 | M&L for 4.8 mm thick float glass ordinary quality' frosted glass and glazing with aluminum beeding and gasket to aluminum framework in square exc 0.50 sqm in each pane in repair complete all as specified and directed |
| 61 | S & F for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads complete all as specified and directed. |
| 62 | S & F in repair for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads complete all as specified and directed. |
| 63 | S&F of door closer hydraulically regulated design No 3, universal type, suitable for door shutters of 851 to 1000m in width and weifht between 61 to 80 kg etc complete all as specified and as directed |
| 64 | S&F double legged door stopper of aluminium alloy with rubber complete all as specifified and as directed. |
| 65 | M&L for 10 to 12 mm thick toughned glass door fixing to the wall or ground including hinges cleats etc incl all necessary wooden beading, gasket screws etc. complete all as specified and directed. |
| 66 | S&F Double Action Floor Spring Hydraulically Regulated made up of minimum 1.25mm thick Aluminium Alloy sheet foundation Box, Main Body with stainless steel cover, outer ring pivot made of brass, other part made Mild steel heavy duty and fixing to Aluminium Shutters with necessary fittings as required/ ordered at site(s), complete all as specified and as directed. |
| 67 | M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of existing sheet in any position, complete all as specified and directed |
| 68 | S&F in repairs for 5 mm thick polycarbonate sheet of any colour as in roof covering/cladding to wall fixed with coach screws and washers over Aluminium cover Strip 40x3mm and rubber washer in each joint complete all as specified and directed |
| 69 | M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 White cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed. Note : Payment for providing grooves shall be made separately. |
| 70 | M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed |
| 71 | S&F stainless steel letters (English/ Hindi) and grade SS-204 consisting of 100-300mm high , 50mm width and 25mm depth hollow walls fixed on wall surface or on ACP sheets board of any descriptions using stainless steel screws of suitable size or best qualith adhesive complete all as specified and as directed. |
| 72 | M & L for preparation of old wall surfaces by removal of existing treatment and apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 1mm thick wall care putty on old scraped surfaces and obtain smooth finish using sand paper complete all as specified and directed . |
| 73 | M & L for preparation of old surfaces by removal of existing treatment and apply one coats of cement based paint over a coat alkali primer resistance incl one layer of 1mm thick wall care putty on old scraped surfaces and obtain smooth finish using sand paper complete all as specified and directed . |
| 74 | M&L for providing and laying factory made kerb stone of M-25 grade cement concrete inposition to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and directed |
| 75 | M & L for preparation of old stone, concrete surfaces of any description over 10 CM width or girth and applying one coat of plastic emulsion paint (Weather Coat) on old footpath/colour tiles/ kerb stone etc (colour and pattren as per approved by EIC ) complete all as specified and directed. |
| 76 | Removing/cleaning of silt, mud,etc under culvert and in the drain of any width and length in soft/loose soil including depositing of removed material from site at a distance exc 500 m and n exc 1.5 KM deposited where complete all as specified and directed |
| 77 | M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/benching and all other similar works including necessary formwork complete all as specified and directed |
| 78 | S&F in repair precast factory made polycrete (SFRC) medium duty perforated drain cover 75-100 mm thick rectangle in shape upto 01 sqm area each with hole for drain complete all as specified and directed |
| 79 | Dismantling of fencing post or strut (wood, steel or RCC) any section, posts embeded in concrete, brick work, masonery etc, including taking out embeded portion in concrete, and making good disturbed ground complete all as specified and directed |
| 80 | Demolition of cement concrete of any description and in any position not otherwise specificially provided for complete all as specified and directed |
| 81 | Dismantling of barbed wire any type complete all as specified and directed. |
| 82 | Dismantling of concertina coil of any size any description fixed on posts or angle of any kind all as in fencing complete all as specified and directed. |
| 83 | S&F MS work as in post and strutt and fencing, drilled and countersunk for balusters running bars for doors balusters,noising to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts,posts and struts in fencing including cutting tops to shape as directed drilling hoes nothcing for wire etc flat iron fillets ( for securing wire mesh ) including all necessary drilling bolting or riveting etc. and similar work conforming to Fe - 290 Gde E - 165 complete all as specified and directed |
| 84 | S&F for plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attchment confirming to Fe 410-0 or Fe 310-0 complete all as specified and directed. |
| 85 | M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed |
| 86 | S&F in repair two strand galvanised steel barbed wire 2.24mm dia barbed with 2mm dia bars @ 75mm spaciang and fixed to any type started rails strained bolts incl securing or tying at closing with and provn of galvanised mild steel wire staples or steel pins complete all as specified and directed |
| 87 | S&F for 900/600 mm dia concentrina spiral coil fencing with punched tape and 6 m max openable length, on wall with angle iron Y shaped with 9 horizontal RBT reinforced barbed wire studied with GI staples and GI clips to retain horizontal incl necessary bolts or GI barbed wire tied to angle iron, all complete as per direction of EIC, with reinforced barbed wire tape (RBT)/spring core (2.5 mm thick) wire of tensile strength of 165 kg/sqmm with tape (0.52mm thick) and weight 43.47 gm/m complete all as specified and directed |
| 88 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and directed |
| 89 | M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm agg. ) as in plinth protection / path/ any paved area complete all as specified and directed. |
| 90 | M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base all as specified and directed. |
| 91 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, with grey cement, pigment incl 25mm thick sand filling complete all as specified and directed. |
| 92 | M&L for 60 mm thick machine cut precast concrete inter locking paver block except tile ,(M-35) grade any clours as approved by EIC /GE complete all as specified and directed |
| 93 | M&L for 80 mm thick machine cut precast concrete inter locking paver block with grey cement and pigment ,(M-40) grade any clours as approved by EIC /GE complete all as specified and directed |
| 94 | M&L for 80 mm thick machine cut precast concrete inter locking paver block except tile ,(M-40) grade any clours as approved by EIC /GE complete all as specified and directed |
| 95 | M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed |
| 96 | M&L for Cement mortar 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, for tiles under the floor complete all as specified and directed |
| 97 | Dismantling of floor/ wall tile including cement mortar complete all as specified and directed |
| 98 | M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed. |
| 99 | Removing daberies/excavated material to a distance exceeding 1.5KM but not exceeding 5 KM and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed Please Enable Macros to View BoQ information |