| 1 | Excavation in trenches in any type of soil not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for laying of cable, foundation etc and getting out complete all as specified and directed. |
| 2 | Excavation in trenches in any type of soil not exc. 1.5 mtr wide and exc. 1.5 mtr and not exc. 3.0 mtr in depth for laying of cable, foundation etc and getting out complete all as specified and directed. |
| 3 | M&L for sand cushioning & covering of UG cable using crushed metal sand in trenches for cable protection complete all as specified and directed. |
| 4 | M&L for sub class 'B' bricks well burnt of size 23 x 11.5 x 7.5 cm for protection of UG cable laid dry flat over the cable width wise across the length of the cable and abutting each other with gap less than 10mm between the adjacent bricks in trenches complete all as specified and directed. |
| 5 | M&L for laying un-reinforced precast concrete cable cover, class HV type-1, flat size 300x180x40 mm for protection of underground cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exc. 10mm over under ground cable in trenchescomplete all as specified and directed. |
| 6 | Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and directed. |
| 7 | Removing of excavated soil to a distance n exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 8 | M&L for cutting existing road/ hardstanding of any type by using crow bar chisel upto a depth of 60 cm for laying HDPE/ GI pipe upto 100 mm including making good the surface by returning, filling, watering, ramming in layers of 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 9 | M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundations and mass concrete for foundations of poles etc complete all as specified and directed. |
| 10 | M&L for PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary from work for finishing exposed faces of concrete smooth and even using extra cement complete all as specified and directed. |
| 11 | Taking out carefully LT cable of size From 10 sqmm to 300 sqmm or type or make from ground/ poles/ pipes etc and testing for serviceability and laying the same serviceable LT cables under ground/ on poles/ through pipes etc at same or any other location and testing after connections complete all as specified and directed.Note:- (a) Item to be measured only when cable is found serviceble for reuse.(b) Necessary excavation, sand cushioning, cable protection covers, returning, removal etc shall be measured and paid separately under relevant items. |
| 12 | Supplying, laying, jointing and testing in replacement underground XLPE insulated & PVC sheathed, armoured heavy duty multistranded electric cable with aluminium conductor, 1100 volts grade in trenches/ ducts/ along poles/ through pipe/ under road/ PCC etc and connecting with new aluminium lugs including taking out existing unserviceable cable of any size/ type complete for the following cables of cross sectional area all as directed: Notes:(a) Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc shall be measured and paid separately.(b) Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses.(c) Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor. |
| 13 | 25.0 Sqmm, 4 core. |
| 14 | 70.0 Sqmm, 3.5 core. |
| 15 | 95.0 Sqmm, 3.5 core. |
| 16 | 120.0 Sqmm, 3.5 core. |
| 17 | 240.0 Sqmm, 3.5 core. |
| 18 | Taking out HT cable of size from 95 sqmm to 185 sqmm type or make from ground/ poles/ pipes etc and testing for serviceability and laying serviceable HT cables under ground/ on poles/ through pipes etc at same or any other location and testing after connections complete all as specified and directed.Note:- (a) Item to be measured only when cable is found serviceble for reuse.(b) Necessary excavation, sand cushioning, cable protection covers, returning, removal etc shall be measured and paid separately under relevant items. |
| 19 | Supplying, laying, jointing and testing in replacement HT underground electric power cable, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, (conforming to IS-7098 Part-I), ISI Marked, with aluminium conductor multi stranded, heavy duty,11000 Volts grade ( earthed ) in trenches/ ducts/ along poles/ through pipe/ under road/ PCC etc complete including taking out existing unserviceable cable of any size/ type complete for the following sectional area complete all as specified and directed.Notes:(a) Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc and HT cable end joints/ straight through joints shall be measured and paid separately.(b) Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses.(c) Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor. |
| 20 | 95.0 Sqmm, 3.0 core. |
| 21 | 120.0 Sqmm, 3.0 core. |
| 22 | 185.0 Sqmm, 3.0 core. |
| 23 | M&L for heat shrinkable indoor type cable end joint complete with jointing material and accessories for 3 core XLPE armoured aluminium conductor HT U/G cable 11000 volts grade (earthed) and testing after jointing of the following sizes : |
| 24 | 95 sqmm, 3 core |
| 25 | 120 sqmm to 185 sqmm, 3 core |
| 26 | Material and labour for heat shrinkable outdoor type cable end joint complete with jointing material and accessories for 3 core XLPE armoured aluminium conductor HT U/G cable 11000 volts grade (earthed) and testing after jointing of the following sizes : |
| 27 | 50 sqmm to 95 sqmm, 3 core |
| 28 | 120 sqmm to 185 sqmm, 3 core |
| 29 | M&L for heat shrinkable straight through joint complete with jointing material and accessories for 3 core XLPE armoured aluminium conductor HT U/G cable 11000 volts grade (earthed) and testing after jointing of the following sizes : |
| 30 | 50 sqmm to 95 sqmm, 3 core |
| 31 | 120 sqmm to 185 sqmm, 3 core |
| 32 | Supply and laying in trenches/ fixed to poles/ wall/ laid in floor GI steel tubing 80mm bore (dia) Light grade including fitting bolt, nut & washers etc or wooden rubber bushing at the ends of complete all as directed incl disconnection and taking down existing tubing complete all as specified and directed. |
| 33 | All as per item No 18 but size of pipe 50mm dia. |
| 34 | Supplying, errecting and fixing in replacement steel tubular swaged poles of following type and height, complete with cast iron base plate, heat resistance finial taper plug, bolts, nuts and screws as specified including painting with two coats of synthetic enamalled paint over one coat of red oxide primer and 06 Nos bands/straps with white/ red/ black/ yellow as required (30cm wide each) epoxy heat resistant paint at a distance 30cm from plinth block and numbering of poles with black synthetic enamel paint in 2.5 cm height including taking out existing unserviceable pole of any type/ height/ make etc and removing from site complete all as specified and directed.Notes: 1. Excavation, returning, removal, PCC for foundation and coping etc shall be measured and paid separately.2. Any damage done during erection of pole to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses.3. Cost of T&P required for transporting/ handling/ erection etc of pole is deemed to be included in the rate quoted by the contractor. |
| 35 | Type 410-SP-31, 9.00 metre long |
| 36 | Type 410-SP-55, 11.00 metre long |
| 37 | Supplying, installing and testing in replacement gang operated air break switch 12 insulator type, HT 11 KV, AC 50 C/S, Triple pole, Horizontal/ vertical mounting type, mechanically operated from ground, mounted on 12 silicon rubber insulators 11 KV grade and steel frame, current rating upto 200 Amps complete with fuse mounting, fuse carriers and fuse elements of required capacity fixed on the pole structure on channel/ angle iron/ cross arm with suitable GI nuts, bolts & washers etc including taking down existing unserviceable of any type/ size etc and removing from site complete all as specified and directed. |
| 38 | Supplying, installing and testing lightning arrestor, station class type of rated voltage 11 KV and discharge current capacity 65 KA suitable for 11000 Volt including taking down existing unserviceable of any type/ size etc and removing from site complete all as specified and directed. |
| 39 | S&F in replacement of drop out fuse unit explusion type for out door air break gang operating switch single pole mounting on and including insulators for 11 KV working pressure fixed to and including MS Channel with nuts & bolts and washers etc synthetic bounded fuse carring tube complete with line tap suitable for current carring capacity upto 200 Amps complete all as specied & directed. |
| 40 | Material and labour for switch air break gang operated triple pole out door type ( Horizental ) as required at site, 33 KV 50 cycle AC Suitable for current rating upto 400 Amps mechanically operated mounted on porcelene insulators (09 insulators ) and frame with operating mechanism from ground level with earth switch on channel/ angle iron/ cross arm with suitable GI nuts, bolts & washers etc including taking down existing unserviceable of any type/ size etc and removing from site complete all as specified and directed. |
| 41 | Supplying, installing and testing station class type lightning arrestor suitable for 33 KV discharge current 65 KA fixed on existing steel structure including connection with earth strip conforming IS 3070 (Part -3) 1983 Class 'A' complete all as specified and directed including taking down existing unserviceable of any type/ size etc complete all as specified and directed. Please Enable Macros to View BoQ information |
| 42 | Supplying, installing and testing station class type lightning arrestor suitable for 33 KV discharge current 65 KA fixed on existing steel structure including connection with earth strip conforming IS 3070 (Part -3) 1983 Class 'A' complete all as specified and directed including taking down existing unserviceable of any type/ size etc complete all as specified and directed. Please Enable Macros to View BoQ information |