| 1 | Taking down Chowkat or Frame with shutters (without taking off Shutter from the Frame) not exc. 1.50 Sqm complete all as specified and as directed. |
| 2 | Taking down Chowkat or Frame with shutters (without taking off Shutter from the Frame) exc. 1.50 Sqm but not exc. 4.00 Sqm Each, complete all as specified and as directed. |
| 3 | S&F Factory Made Solid PVC Door Frame of size 50 x 47 mm made out of 5.0 mm thick plain colour PVC Sheet reinforced with Mild Steel Square Tube, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, complete all as specified and as directed. |
| 4 | S&F Factory Made Solid Panel PVC Door Shutter 30mm thick, consisting of frame made out of Mild Steel Tube of 19 Gauge thickness and size of 19mm x 19mm for Stiles and 15mm x 15mm for Top & Bottom Rails. Mild Steel Frame shall have a coat of Steel Primer of Approved Make and Manufacturer. Mild Steel Frame shall be covered with 5.0mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming Stiles and 5.0mm thick, 75mm wide PVC Sheets For Top Rail, Lock Rail & Bottom Rail on either side, and 10mm (5.0mm x 2) thick, 20mm wide Cross PVC Sheet as gap insert for Top Rail, Lock Rail & Bottom Rail. Panelling of 5.0mm thick PVC Sheet Beading on either side and joined together with Solvent Cement Adhesive, etc. An additional 5.0mm thick PVC Strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC Solvent Adhesive, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, complete all as specified and as directed. |
| 5 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m deep for sewage pipe line etc. and getting out in soft/loose soil all as specified and as directed by Engr-in-Charge. |
| 6 | M&L Excavating over areas, n exc 1.5 m deep and getting out Soft/loose soil complete all as specified and directed. |
| 7 | Returning, filling in, including spreading leveling watering and well ramming in layers n,exc 25 cm thick in soft /loose soil for sewage pipe line /manhole and cleaning the site complete all as specified and as directed. |
| 8 | Removing excavated materials n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point complete all as specified and directed. |
| 9 | Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed. |
| 10 | M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed. |
| 11 | Labour only Brick Work using old bricks obtained from demolition, Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed. |
| 12 | M&L Brick Work with Sub-Class ‘B’ Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directec. |
| 13 | Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water, remove dust, debries/ rubbish, etc., complete all as specified and as directed. |
| 14 | Taking down plastering on lathing (other than wire-netting), without removing lathing, in lime mortar (one side only measured in cases where both sides are plastered) complete all as specified and as directed. |
| 15 | M&L 10mm thick rendering in CM (1:6) on other side of lathing finished even and fair without using extra cement complete all as specified and as directed. |
| 16 | M&L Rendering 15mm thick in Cement Mortar on fair faces of brick work or concrete surface of wall in two layer, first layer 10 mm thick in cement morter (1:4) and top layer 5mm thick in cement morter (1:4) using water proofing compound @ 3% by weight of cement and finishing the surface even and smooth without using extra cement including necessary scafolding and saftey measures complete all as specified and as directed. . (NOTE:-WPC shall be measured and paid separately) |
| 17 | M&L Rendering 15mm thick in CM 1:4on fair faces of brick work or concrete surfaces of walls, with water proofing compound finished even and smooth Brushing neat cement slurry with 3.0kg of cement per sq. metre ( without using extra cement) complete all as specified and directed. |
| 18 | Material and labour for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement ,including forms ,moulds, mitred/stopped ends etc complete all as specified and directed. |
| 19 | Material and labour for Add or deduct for each 25 mm girth or part there of over or under 30cm ditto etc complete all as specified and directed. |
| 20 | M&L Preparing new plastered surfaces of Walls and applying Two Coats of Exterior Emulsion Paint Weather Coat over a coat of Primer (as per Manufacturer’s instructions), and applied over 3mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 21 | M&L Rendering (Internally) 10mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and Smooth without using Extra Cement complete all as specified and as directed. |
| 22 | M&L preparing new plastered surfaces of wall and and applying Two Coats of Distemper Oil Emulsion over a coat of alkali resistant primer complete all as specified and as directed. |
| 23 | M&L Rendering 5.0mm thick in Cement Mortar 1:3 on Concrete Surfaces of Ceiling, etc. finishing Plastered Surfaces Even and Smooth, without using Extra Cement. complete all as specified and as directed. |
| 24 | Supply only Integral Water Proofing compound, conforming to IS 2645 and as approved, complete all as specified. |
| 25 | S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 straps, etc. have screwed, ends including keys, cotters, wedges, etc. for timber trusses and similar work conforming to Fe- 290 Gde-E-165 complete all as specified and as directed. |
| 26 | S&F Aluminium alloy Handle 150mm long, Extruded Section, Fabricated type, anodized and fixed, complete all as specified and as directed. |
| 27 | S&F Aluminium anodized, Barrel Tower Bolt 150mm long, Extruded Section and fixed, complete all as specified and as directed. |
| 28 | S&F Powder coated Aluminium anodised doors, windows, partitions and ventilators using aluminium sections of size and type approved by Engineer-in-Charge including jointing cleats, snap beading etc, complete all as specified and as directed. |
| 29 | S&F powder coated aluminium window and ventilator shutters,(Thickness or powder coating not less than 50 micron). sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, etc.complete all as specified and directed. |
| 30 | S & F powder coated aluminium door shutters (Thickness or powder coating not less than 50 micron)., aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 31 | S&F 4 mm thick heat absorbing/tinted glass of any size with aluminium bedding and complete all as specified and directed. |
| 32 | S& F 5.0 mm thick sheet glass ordinary/tinted/ Filmed to match exixting quality and glazing with oil putty in squares exc 0.5 sq. m in each pane in squares.complete all as specified and directed. |
| 33 | S&F 4 mm thick frosted/ pin headed glass in ventilator shutters including hacking out old broken glass any, size, quality or description from wooden / metal frame works all as specified and directed by Engr-in-Charge |
| 34 | S&F Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples complete all as specified and as directed.NOTE: Cost of Second Class Hardwood Bead-ing shall deemed to be included against Glazed and Skeleton Shutter. |
| 35 | S& F 100 mm stainless steel Butt hinges with with SS Screw complete all as specified and directed. |
| 36 | S&F Aluminium anodised sliding door bolts of size 250 mm long, with hasp & staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extreded sections or cast aluminium alloy.complete all as specified and directed. |
| 37 | S & F in repairs aluminum mortice lock verticle type 75 mm 4/6 levers complete all as specified and directed |
| 38 | S & F in repairs floor door stopper aluminium alloy body overall length 140 mm and tonge , anodised with hard drwansteel spring complete all as specified and directed |
| 39 | S&F in repairs stainless steel curtain rod of 20/25 mm bore incl brackets and end knobs for door and window complete all as specified and directed. |
| 40 | S & F In repairs Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specififed and directed |
| 41 | Demolition of Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed. |
| 42 | M&L Cement Concrete type C2(1:3:6) using 40mm graded crushed stone aggregate 75mm thick as in Plinth Protection, etc. laid in alternate Bays, finished Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. |
| 43 | M&L Cement Concrete type B1(1:2:4) (20mm graded crushed stone aggregate) 40 mm thick as in Floor, finishing Concrete Surfaces Even and Smooth with using Extra Cement, complete all as specified and as directed. |
| 44 | M&L Plain Cement Concrete type D2 (1:4:8) using 40 mm graded aggregate as in Foundation, Filling and Mass Concrete, complete all as specified and as directed. |
| 45 | &L Plain Cement Concrete type B-1, (1:2:4) (20mm graded crushed stone aggregate) as in Coping bed plate,hold fast etc,block benching,channeling slightly rounded or chamfered angle and throating including form work and finishing all exposed faces of cement concrete complete all as specified and as directed. |
| 46 | Dismantling Reinforced Cement Concrete of any description and in any Position not otherwise specifically provided for, complete all as specified and as directed. |
| 47 | M&L RCC (Nominal Mix) 1:2:4 type B-1 (Using 20mm graded stone aggreagate) as in slab, shelves supported on walls beam & coloumns in floor roof including balconies, canopies, deck slabs & shelves complete all as specified and directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 48 | M & L pre cast RCC (1:2:4) type B-1 using 20 mm nominal size crushed and graded stone aggregate in cover slabs or of similar items including necessary cutting, form work etc.cement complete in all respect as specified and directed. |
| 49 | M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed. |
| 50 | M&L Formwork to Soffits of suspend slab such as Roof slab, Floor slab, landings and similar works horizontal or sloping etc., not exceding 200mm thick ,flat rough finished surfaces of concrete, complete all as specified and as directed. |
| 51 | M&L Preparing old decorated Plaster Surfaces of Wall and applying One Coat of oil bound (any colour /tint) complete all as specified and as directed. |
| 52 | M&L Complete removal of existing Treatment of old decorated Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion over a coat of primer and applied over 3mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 53 | M&L Preparing old decorated Plaster Surfaces of Wall and applying One Coat of White Wash (any colour/ tint) complete all as specified and as directed. |
| 54 | M&L Preparing old decorated Plaster Surfaces of Ceiling and applying One Coat of White Wash, complete all as specified and as directed |
| 55 | M&L Preparing old decorated plastered surfaces of Walls and applying One Coats of Exterior Emulsion Paint Weather Coat (any colour /tint) (as per Manufacturer’s instructions), complete all as specified and as directed. |
| 56 | M&L for complete removal of existing treatment and applying two coats of weather coat over a coat of polymer (exterior grade) putty to make surface smooth and one coat of primer damp sheild over old plastered wall complete all as specefied and directed. |
| 57 | M&L Preparing new Surfaces of ceilings and applying Three Coats of White Wash, complete all as specified and as directed. |
| 58 | M&L Applying one coat of Acrylic distemper to old wall surfaces of walls and cornices including preparation of old decorative surface and removal of smoke soot ,moulds ,moss and efflorescent salts and trading oil and greasy spot complete all as specified and directed |
| 59 | M&L Applying two coats of acrylic distemper to newly plastered/previously untreated wall over a coat of 1 mm layer wall care putty over a coat of primer including preparation of newly platsered wall complete all as specefied and directed. |
| 60 | Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), and removing rubbish off the Premises, complete all as specified and as directed. |
| 61 | M&L glazed /matt finished vitrified coloured tiles 8 to 10 mm thick (square/ rectangular) of any shade, polished, area of each tiles exceeding 0.42 but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including over 15mm thick screed bed in CM 1:6 complete all as specefied and directed. |
| 62 | M&L glazed /matt finished vitrified coloured tiles 8 to 10 mm thick (square/ rectangular) of any shade, polished, area of each tiles exceeding 0.42 but not exceeding 1.00 sqm, as in skirting/ Dado. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed in CM 1:4 complete all as specefied and directed. |
| 63 | M&L Mat Finish /Non screed Ceramic Tiles 10 mm thick (square/ rectangular) in any Shade, Polished, size of each Tile 600mm x 600mm as in Floors, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over 20mm thick screed bed in cement sand mortar (1:6)complete all as specified and as directed. |
| 64 | S&F Coloured Glazed ceramic tiles 450 x 300 mm x 7 to 8 mm thick, in skirting /dado etc set and jointed in neat cement slurry and pointed with epoxy filler to match over 10mm screeding in Cement mortar 1:3 complete all as specefied and directed. |
| 65 | S& F for laying 15mm bore steel tubes medium grade glavanised with all fitting and fixed complete to walls/ceilings or laid in floors including taking down complete all as specified and directed |
| 66 | S&F for laying 20mm bore steel types medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors including taking down complete all as specified and directed |
| 67 | S & F Unplasticised PVC pipes 15 mm bore of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe including taking down complete all as specefied and directed. |
| 68 | S & F Unplasticised PVC pipes 20 mm bore of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe including taking down complete all as specefied and directed. |
| 69 | Cutting chases ,pinning ,making good to facing where required and painting in cement mortar 1:3 to ends or egdes of landings ,steps,cills ,sunshed,shelves,lintels etc and cutting chases for concealed water tubing etc inlcuding making good cutting shall n.exc 10 cm girth complete all as specified and directed. |
| 70 | S & F in repair only 15 mm bore pillar tap, fancy type cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanuls and fly nuts, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 71 | S & F,as in repair, 15 mm bore bib taps, cast copper alloy,cromium plated, fancy type, with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 72 | S & F, as in repair, stop valve/angle cock, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down high pressure, with crutch or butterfly handles for 15 mm bore pipe or for unions including dismantling wall tiles and fixing broken tiles with matching colour, area of wall tiles not exceeding 0.50 sqm. complete all as specified and directed. |
| 73 | S & F, waste coupling CP 32/40 mm dia for glazed ware basins/ Sink etc with fly nuts flanged including 610 mm long waste pipe etc complete all as specified and directed. |
| 74 | M & L, as in repair for 75 mm dia of outlet PVC(SWR) floor trap, plain with granting including jointing with solvent cement all as specified and directed |
| 75 | S & F, as in repairs, sheet glass self assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with cromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 76 | S&F in repair vitreous china wah basin pedestal pattern white, flat back size 550 x 400 mm, with 32mm dia Brass Chromium Plated Waste Fitting, excluding taps, waste chain, plug and porcelain stopper but including erecting stand complete all as specified and directed. |
| 77 | S & F,in repairs Vitreous China Urinal, full stall type, whitewhite, with grating and union for discharge pipe, (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinals against wall in cement mortar (1:2) securing urinals to plugs with and including 60 mm brass screws and pointing around urinals back in cement with spreader complete all as specified and directed |
| 78 | S&F 08 mm thick curved shaped urinal partition with frosted glass of size 900x450 mm including fixing accessories, fixing bolt, etc complete all as specified and directed. |
| 79 | S&F White PVC Flushing Cistern 10 Litre capacity, Low Level Valve Less, Syphonic Action type with Inlet, Ball Valve, Float and Handle including Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 and fixed including taking down/out unserviceable Flushing Cistern and connected Items, complete all as specified and as directed. |
| 80 | S & F as in repair, 600 mm x 450 mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commerical plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 81 | S&F in repairs PVC connections 15mm size with PTMT nut of length 450mm complete all as specified and directed. |
| 82 | Dismantling and breaking up PVC drain pipes of any dia jointed in CM and taking out of trenches complete all as specefied and directed. |
| 83 | S & F, 110mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls or laid in trenches or floor complete all as specified and directed. |
| 84 | S & F, 75 mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls or laid in trainches or floor complete all as specified and directed. |
| 85 | S&F for PVC (SWR) with access door bend 110mm dia. complete all as specefied and directed. |
| 86 | S&F for PVC (SWR) with access door bend 75 mm dia. complete all as specefied and directed. |
| 87 | S&F in repair PVC(SWR) junction single with access door (single 'T') equal or unequal 75 mm bore. complete all as specefied and directed. |
| 88 | S&F in repair PVC (SWR) junction single access door (single 'T') equal or unequal 110mm bore. complete all as specefied and directed. |
| 89 | S&F in repair PVC (SWR) junction double with access door , (double T), equal or unequal 110mm bore. complete all as specefied and directed. |
| 90 | Supply and Fix 300mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed. |
| 91 | Supply and fix, 150 mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls or laid in trenches or floor complete all as specified and directed. |
| 92 | S & F, PVC cowls 110 mm bore complete all as specified and directed. |
| 93 | S&F in repair tubular Towel rail chromium plated 600mm long 20mm dia D type complete all as specified and as directed. |
| 94 | S&F in repairs Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 95 | M&L in repairs for PVC(SWR) gully trap 125/110 mm setting and jointing with solvent complete all as specefied and directed. |
| 96 | Demolition of old damaged existing water proofing compound on RCC roof of any description and specification and cleaning the surface thoroughly complete all as specified and directed |
| 97 | M & L 15mm thick in cement mortar (1:4) on existing roof surface true to level after applying cement slurry @3Kg/Sqm including taking down plaster etc complete all as specefied and directed. |
| 98 | Supply and laying 3mm thick APP based Polymeric membrane of approved manufacture with weight not less than 3.60 Kg per Sqm reinforced with non-woven polyster febric weight not less than 150gms per Sqm applied over a coat of hot blown bitumen of grade 85/25 @1.2 Kg/Sqm, The overlap shall be not less than 100mm on transverse direction and 75mm on longitudinal direction and sealing overlaps and Applying evenly one coat of aluminium paint @ 0.10 liter per square metre over the APP based polymeric membrane including removal and refixing of PVC tank any capavity on same place with all required necessary fittings complete all as specified and as directed. |
| 99 | S&F in repair 15mm bore two way bib cock cast copper alloy CP Fancy type ,with wall flange screwed down for iron pipe or union , complete all as specified and directed. |
| 100 | S & F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specefied and directed. |
| 101 | S& F in repair of Towel Ring of stainless steel fixed and including Chromium plated brass screws complete all as specified and directed. |
| 102 | S & F in repairs Toilet paper holder of brass chromium plated fixed to walls with chromium plated(CP) brass screws. complete all as specefied and directed. |
| 103 | S & F, as in repair, vitreous china wash down water closet pan (Pedestal pattern) white (excluding flushing cistern ) but including seat cover white closed type and flush pipe complete all as specified and directed |
| 104 | Supply and fix, as in repairs, vitreous china squatting pan of Orrisa pattern size 580mm x 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including connection making good to floor complete all as specified and directed. |
| 105 | S & F, as in repairs, plastic water closet seat, closed pattern with flat bottom, and cover for water closet pan (padestan pattern) complete all as specified and directed. |
| 106 | Supply and fix,as in repair, 32/40 mm dia PTMT 610 mm long waste pipe suitable for WHB complete all as specified and directed. |
| 107 | S&F in repairs stainless steel grating round/ Square cockroach proof with or without hole100/75mm dia complete all as specified and directed. |
| 108 | S&F In repairs Concussive push button taps of cast copper alloy, screwed for iron pipe and fixed complete all as specefied and directed. |
| 109 | Dismanting wall /ceiling board (Fibre pulp insulation) or insulation boards any type and any thicknesses including cover filters complete all as specefied and directed. |
| 110 | S&F 6-10 mm thick PVC hollow panels with to 0.5 mm plain PVC sheet suitably placed in Wall inclding same and matching colour wall angle , u clip, end clip, fillets runners and jointer etc . As in ceiling and walls including aluminium frame work fixed to wall or wooden scantling vertically and horizontally at an interval as directed by Engr-in-Charge complete all as specified and directed |
| 111 | M&L for Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed |
| 112 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. complete all as specefied and directed. |
| 113 | S & F teak wood (1st class, hardwood) frame with 12mm toughned glass work for forming glass house, 3xdoors with all necessary fittings such as U handels in door, door spring , pivot, locking arrangments, brackets complete all necessary fittings which is essential for stability. Note :-(a) Rates also include hacking any type of design on glass approved by GE, french poish/wax polish on wooden. (b) Rates also including any mild steel frame work which is essential or dircted by engr-in-charge.(c) Rates also including making good of all type of finishes which is damaged during execution.(d) teak wood frame dimension to be approved by engr-in-charge before commencing the work |
| 114 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. including cutting chases of exsisting wall for wall taking out concealed conduit ec. and making good disturbed surfaces of walls, floors, etc as per existing specification after providing point wiring under respective items here-in-below complete all as specified and as directed. |
| 115 | Taking down main switches and DBs of any type and make including wooden board / junction box. complete all as specefied and directed. Please Enable Macros to View BoQ information |
| 116 | Taking down main switches and DBs of any type and make including wooden board / junction box. complete all as specefied and directed. Please Enable Macros to View BoQ information |