| 1 | Surface excavation n.exc 30cm deep and averaging 15 cm deep and getting out in Hard/dense soil all as specified and as directed. |
| 2 | M&L for 150mm thick hard core of guage n.exc.63mm using broken stone aggregate spread, levelled, watered and rammed to a true surface all as specified and as directed. |
| 3 | M&L for PCC in foundation filling and mass concrete type C2 1:3:6 (40mm graded stone aggregate) all as specified and as directed. |
| 4 | M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors finished with white cement and pigment including 20mm thick screed bed in CM 1:4 all as specified and as directed. |
| 5 | M & L for Pre-cast PCC block masonry type B-1 (1:2:4) with solid block and set in CM1:6 all as specified and as directed. |
| 6 | M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement all as specified and as directed. |
| 7 | M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including prepartion and applying priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfacestc complete all as specified and as directed. |
| 8 | Excavation in post holes (or similar holes) each n.exc 0.5 cum, getting out in hard/dense soil all as specified and as directed |
| 9 | S&F MS steel work in tubular, trusses incl purlins, special shaped washers etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade 240 all as specified and as directed. |
| 10 | S&F MS works as in wind ties for roof including securing bolts etc complete all as specified and as directed. |
| 11 | M&L for plates of plain or chequered, square cut or notched of steel welded to steel structure for base plate etc all as specified and as directed |
| 12 | M&L for prepainted galvalume aluminium zinc coating GI based corrugated sheet 0.5mm thick of colour having tesile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified. |
| 13 | M&L for prepainted galvalume aluminium zinc coating GI based plain sheet 0.5mm thick of colour having tesile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified. |
| 14 | Supply and fix PVC (SWR) pipes 110 mm bore in any length with rubber ring joints fixed to walls complete all as specified and directed |
| 15 | Supply and fix 110mm PVC (SWR) bends any radius with access door all as specified and directed Please Enable Macros to View BoQ information |