| 1 | Supply of cost of MS Longitudinal welded pipes in Bare condition as per IS : 3589-2002, Gr- Fe410, per Meter length of different diameter and thickness including cost of loading, unloading and freight charges (@1480 KM from factory to delivery at site, excluding GST and Cessa) 100 mm dia. (8 mm thick) |
| 2 | b) 150 mm dia. (8 mm thick) |
| 3 | Lowering MS pipe and Specials in trench upto a depth of 3.0 metre below GL, Laying and jointing the same inside the trench / Over ground by means of Gantry/ Hydra and field joint by means of Electrical arc welding using standard Electrodes per IS specification etc all completea) 100 mm dia. (8 mm thick) |
| 4 | b) 150 mm dia. (8 mm thick) |
| 5 | 500 micron polyurethanr ( PU) as outside coating. |
| 6 | 300 micron food grade epoxy as internal lining |
| 7 | Cutting to requisite length or shape of M.S. Pipe, channels, angles, tees, plates etc. |
| 8 | Field welding of machined ends of pieces of MS pipes and specials for laying the same inside trench over ground by means of electric are welding as per relavent IS spec using standard electrods incl. / edge preparation and charges for deployment of electric generatyor set with fuel , lubricants and all other tools & plants all complete as per spec and direction o f EIC.a) 8mm thickness -2.5 run consolidated rate |
| 9 | Making flange joint to DI/CI pipes, specials and valves where necessary with supply of required rubber insertion and nut bolts, washers etc. of approved quality and type all complete as per specification and direction of EIC (Nut and bolts shall be of TATA/GKVV rate).a) 150 mm dia (ID) MS pipe |
| 10 | b) 100 mm dia (ID) MS pipe |
| 11 | Supplying CI Mechanical joint fitting (i.e. Bend, Tee, Reducer etc.) as per relevant IS code with rubber gaskets and nut bolts complete as per direction of EIC (Rate including 1% Cess)NB: Payment on this item will be made only after installation, fitting, fixing & as per actual execution of specials in the pipeline works. No advance payment on more supply will be entertained under any circumstances.a) 150 mm dia. i) CI/MJ Collar Coupling |
| 12 | b) 150 mm dia. i) 45o MJ Bend |
| 13 | c) 150 mm dia. i) 90o MJ Bend |
| 14 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 15 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety |
| 16 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor/upto 4 m(i) Tor steel/Mild SteelII. Other than SAIL/ TATA/RINL |
| 17 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 18 | Construction of different dia sluice valve / Air valve / washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt. approved drawing with 25 cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over 150 mm thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100 mm & 150 mm thick slab on top of chamber with 1% reinforcement in roof slab including supply of 150 mm X 150 mm C.I. surface box embedded into RCC cover slab all complete including cost of labour & materials.a) 150 mm dia |
| 19 | Supply and delivery of CIDF sluice valve (Special type) PW-1.00 of different dia make with CI double flanged non rusting spindle sluice valves conforming to IS 14846 -2000 with latest emended having body dome/bonnet and cover of C.I.Gr-F.G 210mtr. spindle of IS-6603 G.R- 12/Gr-13 non-magnetic, nuts seat rings are of Gunonetal as per IS:318 LTB-2 flanges and drilled to IS:1538 Part IV & VI valves are suitable for max. working pressure of 10kg/cm2(seat test) and body tested to 15kg/cm2.N.B: The above item should be procured from the reputed manufactures as per deptt. approved vender lista) 150 mm dia |
| 20 | b) 100 mm dia |
| 21 | Supply of M.S. Flange (slipper type) as per IS-6392 TABLE 17 Thickness12mma) 150 mm dia |
| 22 | b) 100 mm dia |
| 23 | Making holes in two sides of wall of culvert/drain or any other structures in any places for laying any dia pipe line within structures intwo sides of wall of culvert /drain /any structure at any places and mending good damages all complete as per direction of EIC. |
| 24 | Supplying, fitting and fixing street pattern hydrant 65 mm with guaranteed spindles and C.I.cover complete. |
| 25 | Supplying, fitting and fixing C.I.cover for street pattern hydrant |
| 26 | Cutting DI pipe (all class & type) to required length with cutting device etc. and grinding the cutting portion with file as per direction and satisfaction of EIC.a) 150mm.dia.to 200mm.dia pipe |
| 27 | Chamfering the spigot end of all type/class of DI pipe for proper using of push joint by means of grinder set at site for proper joint etc. all complete as per direction of EIC.a) 150mm dia. |
| 28 | Add GST @ 18 % |
| 29 | Add Cess @1% Please Enable Macros to View BoQ information |