| 1 | Boring,ProvidingandinstallingcastinsitusingleunderreamedpilesofspecifieddiameterandlengthinM20cementconcrete,excludingthecostofsteelreinforcementbutincludingthecostofboring,cementconcrete,allcomplete.(Lengthofpileforpaymentshallbemeasured upto to the bottom of pile cap) : |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level. Cement concrete grade M-10 (Nominal Mix) with 40 mm maximum size of stone aggregate |
| 3 | Brick work will well burnt open bhatta bricks crushing strength not less than25kg/cm² and water absoption not more than 20% in foundation and plinthIn cm 1:6. |
| 4 | Providing and laying in position specified grade reinforced cement convrete excluding the cost of centering and shuttering, finishing and reinforcement - All work up to plinth level. Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate |
| 5 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated Bars |
| 6 | Centering and shuttering including strutting, propping etc.and removal of form for : Foundations, footings, bases of columns, etc. For mass concrete. |
| 7 | 18mmcementplasterintwocoatsunderlayer12mmthickcementplaster1:5(1cement:5coarsesand)finishedwithatoplayer6mmthick cement plaster 1:4 (1 cement: 4 fine sand). |
| 8 | 6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand) |
| 9 | Wallpaintingwithplasticemulsionpaintofapprovedbrandandmanufacture to give an even shade: Two or more coats on new work |
| 10 | Distemperingwith1stqualityacrylicdistemper(readymixed)ofapprovedmanufacturer,ofrequiredshadeandcolourcomplete,aspermanufacturer's specification. Two or more coats on new work. |
| 11 | PaintingSteelworkwithDeluxeMultiSurfacePainttogiveanevenshade.Twoormorecoatapplied@0.90ltr/10sqmoveranundercoatof primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 12 | Kota stone 25mm thick flooring over 20 mm (average) thick base laid overand jointed with grey cement slurry mixed with pigment to match theshade of the slab including rubbing and polishing complete withbase of 1:4 cement mortar (1 cement : 4 course sand) (minimum size ofkota stone 2.0 sqft) |
| 13 | Structural steel work riveted, bolted or welded in built upsections, trusses and framed work, including cutting, hoisting, fixingin position and applying a priming coat of approved steel primer allcomplete: |
| 14 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply including all CPVC plane andbrass threaded fitting i/c fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall. 15 mm nominal outer dia .Pipes. |
| 15 | Providing and laying below ground unplasticised PVC pipe to withstand working pressure of 4 kg/cm2 soild waste pipes confirming toIS:13592 and IS:4985 including jointing with seal ring confirming toIS :5282 leaving 10mm gap for thermal expansion all necessaryfittings etc. complete. Excavation to be paid seperataly 110 mm diameter OD |
| 16 | Providingandfixinginpositioncollapsiblesteelshutters(ChannelGate)withverticalchannels20x10x2mmandbracedwithflatirondiagonals20x5mmsizewithtopandbottomrailofT-iron40x40x6mmwith40mmdia,steelpulleyscompletewithbolts,nuts,lockingarrangement,stoppers,handles,includingapplyingaprimingcoatofapprovedsteelprimer.Ratesincludesrecesscuttinginfloor and making good the same where ever required. |
| 17 | Provision for all type of Plumbing work as per sor complete direction of engineer in charge. |
| 18 | Provision for all type of Electrification work as per sor complete direction of engineer in charge. Please Enable Macros to View BoQ information |