| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in PVC casing caping with modular switch modular plates suitable size modular surface box of specified Category and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.;(c) Group C -- with Cat B Modular Accessories |
| 2 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required;(b) Cat B |
| 3 | Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/ wooden block including connections etc as required. |
| 4 | Supplying and fixing brass batten/ angle holder including connections etc as required. |
| 5 | Supplying and fixing following size modular PVC box alongwith modular base and cover plate for modulator switches in recess etc. as required;(k) 6 Module Cat B |
| 6 | Supplying and fixing following size modular PVC box alongwith modular base and cover plate for modulator switches in recess etc. as required;(i) 3 Module Cat B |
| 7 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required;(h) 5/6 A switch Cat B |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required;(k) 3 pin 5/6 A socket outlet Cat B |
| 9 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required;(j) 15/16 A switch Cat B |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required;(l) 6 pin 15/16 A socket outlet Cat B |
| 11 | Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/Isolator);(j) 8 way single door Cat B |
| 12 | Supplying and fixing following rating double pole 240 V isolator in the existing MCB DB complete with connections testing and commissioning etc as required;(f) 40 A Cat B |
| 13 | Supplying and fixing B series SP MCB 240 V suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required\\";(c) 5 A to 32 A Cat B\\" |
| 14 | Supply and erecting meter box suitable for single phase energy meter and incoming SP/DP MCB fabricated out of 16 SWG sheet steel powder coated complete as required and conforming to the requirements of Goa Electricity Department. |
| 15 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately).;(b) In rocky strata |
| 16 | Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt). |
| 17 | Providing and laying earth connection from earth lectrode with4 mm dia copper wire in 15 mm dia GI pipe from earth electrode as required |
| 18 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop arthing . as required |
| 19 | Supply of 2 core armoured PVC/XLPE insulated PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;2 Core 6 sq.mm |
| 20 | Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required.;(a) 20 mm |
| 21 | Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc. as required;(b) Cat B |
| 22 | Supplying and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch on board the modular surface/recessed PVC/GI modular box by suitably increasing its modular capacity modular plate and cover including connection painting etc. as required.;(b) Cat B |
| 23 | Installation earthing testing and commissioning of pre-wired fluorescent fitting/ compact fluorescent fittings of all types complete with all accessories and tube etc. directly on ceiling / wall including connections with 1.5 sq .mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required. |
| 24 | Installationearthing testing and commissioning of ceiling fan including wiring the down rod of standard length ( upto 30 cm) with 1.5 sq .mm FRFRLS PVC insulated copper conductor single core cable etc. as required. |
| 25 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required |
| 26 | Supplying and fixing SP blanking plate in the existing MCB DB complete as required |
| 27 | Supply and making cable end terminations with compression gland and aluminium lugs for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade complete as required.;(3) 2 x 6 Sq. mm. |
| 28 | Supply and erecting of 48 inch (1200mm sweep) ceiling fan double ball bearing type complete with all accessories.;(b) Cat B |
| 29 | Wiring for 5A /15A plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in PVC casing capping alongwith 1 No 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 30 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independent PVC casing capping of appropriate size as required.;(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm casing ) |
| 31 | Supply of 4 feet, LED Single Box type, powder coated CRCA body fitting with all accessories, suitable for 18/20/22W LED tube, including 1no. of LED tube having integral driver, complete as required of makes: Havells, model-Regal Batten, T8 upto 1X22w SSBSWH (tube - Photon Ultra, E2.0 121 3T8 SSTL 20w LED 865 SPC).//Crompton, model-Eco-1, IGP 161 LT8-16 (tube-Ultron, LT8-20-865(2).//Jaguar, model-LUNI 01x120xc, CW, 20w (tube-LTBL 01x020Xc Tube, Al-PC based, CW, 20w).//Bajaj, model-BLRB-DB 118 ( tube-BLRB 20w LED 6500k). or equivalent models of above makes only (superseding at the time of execution), as directed by the Engineer-in-charge. |
| 32 | Supply of 9/10 Watts LED Bulb of make Philips/Crompton/Bajaj |
| 33 | Dismantling of old wiring, casing and caping, wall mounted wooden switch boards, tubelight frames, ceiling fans etc complete with stacking of serviceable items and disposal of unserviceable items. |
| 34 | Supplying and fixing of following sizes of PVC casing caping alongwith accessories on surface as required.;(b)25mm casing capping |
| 35 | Supply and fixing PVC Square/Round block on wall/surface. Please Enable Macros to View BoQ information |