| 1 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 2 | Cement Concrete 1:4:8 with Stone Ballast 40 mm gauge using concrete mixer volumetric type. |
| 3 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 4 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 5 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 6 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 7 | Cold twisted deformed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 8 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 9 | First class burnt brickwork laid in cement sand mortar 1:5 in foundation and plinth |
| 10 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. |
| 11 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 12 | 12.5 mm thick cement plaster 1:4 |
| 13 | Providing and fixing 110mm dia. U.P.V.C bend for Rainwater pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 14 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4kgf /cm²) conforming to IS: 4985, including fixing with MS clamps. |
| 15 | Terracing consiting of tiles 22.86 x 11.43 x 3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top Surface to be left clean after wire brushing |
| 16 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 17 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 18 | Cement pointing 1:2 flush on flat brick flooring |
| 19 | Extra for R.C.C/PCC. work done in each subsequent storey above the first storey upto height of 4 metres or part there of up to the roof top level of that storey. |
| 20 | Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block and Extra for c above 4 meters (where any single storey exceeds 4 metres in height) for every additional height of 2 metres or part there of for Brick Work/ Concrete Block/ Clay Block. |
| 21 | Extra rate for shuttering in each subsequent storey above the first Storey work done in subsequent storey above the first storey upto height of 4metres or part there of upto the roof top level of that storey. |
| 22 | Factory manufactured flush door fixed inposition iron hinges, etc excluding the cost of any fittings other than specified above but including labour for fixing the same in position |
| 23 | 35mm thick |
| 24 | 25mm thick |
| 25 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 26 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 27 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular ections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge.(Glazing and paneling to be paid for separately) : |
| 28 | For fixed portion and chawkhats |
| 29 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug /neoprene gasket required Please Enable Macros to View BoQ information |