| 1 | Dismantling of brick work in cement sand mortar / lime mortar including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material. & staking the serviceable material with all lifts & lead of 100 metre (By Mechanical Means) |
| 2 | Credit of bricks |
| 3 | Credit of brick bats |
| 4 | Scraping Bricks dismantled from brick work in lime or cement. |
| 5 | 115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure |
| 6 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Clerestory windows of area 3 sqm and below. |
| 7 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect Glazing area above 0.09 sqm 4mm thick or 10.78 Kg/ sqm |
| 8 | 12.5 mm thick cement plaster 1:5 |
| 9 | 20mm thick cement plaster 1:5 in two coat work |
| 10 | Cement rendering on plaster 1mm thick |
| 11 | Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. panelled, glazed or glazed and panelled. 30 mm thick |
| 12 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 13 | Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded). |
| 14 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 15 | Providing and fixing commercial plywood 18mm thick |
| 16 | Providing & fixing 6\\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 17 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete ISI designation no I (Size of door up to 700mm) |
| 18 | Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 19 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge. |
| 20 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ). Size 600x600 mm |
| 21 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 mm & 300x300mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 22 | Conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material |
| 23 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 24 | Cement concrete 1:5:10 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 25 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 26 | Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines. |
| 27 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 28 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 29 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
| 30 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete. |
| 31 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggrigate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing of material |
| 32 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing |
| 33 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 34 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 35 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebate weighing 3.43 kg per meter. |
| 36 | Providing and fixing Stainless Steel pipe and fitting of grade A ISI-304 as per IS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer-in- charge. (The pipe length inserted in the fitting shall not be measured for payment) 15.88 mm outer dia pipe |
| 37 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.60 mm (+ 0.05 %) thick |
| 38 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 39 | Providing and fixing ply wood, plain lining, butt jointed including PVC Plug placed at 45 cm to 65 cm centers complete with necessary nails (Frame work shall be payable extra) 4mm thick 3 ply commercial ply wood |
| 40 | Providing & Fixing decorative high pressure laminated sheet 1mm SF thick with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 41 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 42 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats on old distempered work when shade is changed |
| 43 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. |
| 44 | Finishing walls with cement based Water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade. |
| 45 | Add 5.35% Difference of GST from 12% to 18% |
| 46 | Providing and fixing of magnet catchers. complete in all respect as per specification, drawing/design & to the entire satisfaction of Engineer-in-Charge. |
| 47 | Providing and fixing of piano hinges. complete in all respect as per specification, drawing/design & to the entire satisfaction of Engineer-in-Charge. |
| 48 | Providing and fixing of telescop 12'' long. complete in all respect as per specification, drawing/design & to the entire satisfaction of Engineer-in-Charge. |
| 49 | Removing and refixing door shutter after necessary repair etc. complete in all respects and entire satisfaction of Engineer-in-charge. Please Enable Macros to View BoQ information |