| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group B |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 4 | Group B |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required |
| 6 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 7 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 8 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 9 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 10 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 11 | Supplying and fixing following size/ modules, GI box as reuired on the site alongwith modular base & cover plate for modular switches in recess/surface etc. as required. |
| 12 | 12 Module |
| 13 | 8 Module |
| 14 | 6 Module |
| 15 | 3 Module |
| 16 | 1 or 2 Module |
| 17 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 18 | 5/6 A switch |
| 19 | 3 pin 5/6 A socket outlet |
| 20 | 15/16 A switch |
| 21 | 6 pin 15/16 A socket outlet |
| 22 | Bell Push |
| 23 | Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 24 | 3 x 1.5 sq. mm |
| 25 | 3 x 4 sq. mm |
| 26 | 6 x 1.5 sq. mm |
| 27 | 6 x 4 sq. mm |
| 28 | 3 x 6 sq. mm |
| 29 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 30 | 20 mm |
| 31 | 25 mm |
| 32 | SITC of Video call bell with display with necessary specification Video Door Bell Pro 2K Resolution with 3MP Lens,.140° Field of Vision, Night Vision, 2W Speaker Person Detection, Visitor Log, Intruder Alarm, Works with Alexa, Wireless Chime with 36 tunes with all accessories etc. complete as required. |
| 33 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 34 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 35 | 12 way (4 + 36), Double door |
| 36 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 37 | Single pole |
| 38 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 39 | 100 A |
| 40 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 41 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 42 | Supplying, installation, testing and commissioning of 600 mm sweep ceiling fans without regulator i/c wiring the down rod of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.complete as reqd. |
| 43 | SITC of Single Wall Light suitable for retrofit 7.5 Watt Led Lamp. Base of the Wall Light is made of Spun CRCA Sheet and is Circular/oval shape or any other shape as approved . Arm of the wall light is made of mild steel tube. Holder Cap and design is made of CRCA sheet duly approved colour Plated. Base and Arm are duly Powder coated in approved Colour Shade , all colour , shape and model to be approved by the client or Engineer in charge . Mounting Plate is made of CRCA Sheet . Hardware parts are made of mildsteel duly plated. E-27 Lamp holder is fitted in the fixture . Frosted Glass diffuser is provided with the fixture and E-27 LED bulb 7 W in warm/cool light to be provided with the fixture etc as required. |
| 44 | SITC of Double Wall Light suitable for retrofit 7.5 Watt Led Lamp. Base of the Wall Light is made of Spun CRCA Sheet and is Circular/oval shape or any other shape as approved . Arm of the wall light is made of mild steel tube. Holder Cap and design is made of CRCA sheet duly approved colour Plated. Base and Arm are duly Powder coated in approved Colour Shade , all colour , shape and model to be approved by the client or Engineer in charge . Mounting Plate is made of CRCA Sheet . Hardware parts are made of mildsteel duly plated. E-27 Lamp holder is fitted in the fixture . Frosted Glass diffuser is provided with the fixture and E-27 LED bulb 7 W in warm/cool light to be provided with the fixture etc as required |
| 45 | Supplying, installation, testing & commissioning of 200 mm sizes white body Sweep PVC body Fresh Air Ventilator Exhaust fan with louver shutter in the existing opening of toilet room/kitchen etc i/c connection with 1.5 sqmm FRLS PVC insulated wires and fibre sheets etc as reqd. |
| 46 | Supplying, installation, testing & commissioning of 250 mm sizes white body Sweep PVC body Fresh Air Ventilator Exhaust fan with louver shutter in the existing opening of toilet room/kitchen etc i/c connection with 1.5 sqmm FRLS PVC insulated wires and fibre sheets etc as reqd. |
| 47 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . |
| 48 | 12 -15 watt |
| 49 | 18 watt |
| 50 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 51 | 18- 22 watt |
| 52 | Supplying and replacement, installation, testing & commissioning of 2 feet, 10-12 watt capacity wall mounted LED batten fitting with extruded aluminum housing having lumen output > 100 lumens/watt in cool daylight (5700 k to 6500k) power factor> 0.90 CRI> 70 surge protection >, 2.5 kv with integrated electronic driver suitable for mirror light i/c connection of wires with 1.5 sqmm FRLS PVC insulated wires etc complete as reqd. |
| 53 | Supplying , Laying and fixing following size of PVC insulated and PVC sheathed al. conductor armoured power cable of 1.1 KV grade of following ways as reqd. |
| 54 | (a) 3 X 10 sq.mm. cable on surface |
| 55 | Supply & Fixing of 50 X 105 mm PVC snap on trunking i/c body and cover including joint accessories like bend etc. on surface of wall etc. complete as required |
| 56 | Sub Head -II (Credit of Dismantle material)Less for credit buy back of old irrepairable defective items |
| 57 | Assorted size wire in pieces |
| 58 | Assorted size switch/socket |
| 59 | Assorted size conduit/ MS Box/junction box/angle iron frame etc. |
| 60 | Unserviceable Ventilation Fan |
| 61 | Unserviceable Batten Fitting |
| 62 | Unserviceable Downlighter |
| 63 | Unserviceable Ceiling fan |
| 64 | Unserviceable Single/Double Wall Light Please Enable Macros to View BoQ information |