| 1 | CONSTRUCTION OF SHEDE FOR CLEANING, GRADING AND DAL MILL FOR VIDARBHA KRUSHI GRAMASTHA FARMER PRODUCER CO.LTD.AT. MEDSHI Tq. MALEGAON Dist WASHIM |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means--Specification No--Bd.A.1 Page One Number 259 -SSR 2022-23 I No21.01 |
| 3 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc.complete.--Specification No--Bd.A.11 Page One Number 263 -SSR 2022-23 I No21.37 |
| 4 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)--Specification No--Bd. E. 1 Page One Number 287 -SSR 2022-23 I No24.01 |
| 5 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.--Specification No--As directed by Engineer in charge. -SSR 2022-23 I No21.22 |
| 6 | Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)--Specification No--Bd.F.3 Page One Number 298 and B.7, Page One Number38 -SSR 2022-23 I No25.11 |
| 7 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)--Specification No--Bd.F.5 Page One Number 300 and B.7,Page.One Number 38 -SSR 2022-23 I No25.31 |
| 8 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)--Specification No--Bd.F.6 Page One Number 300 and B.7, Page One Number38 -SSR 2022-23 I No25.5 |
| 9 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters forR.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.--Specification No--Bd.F.17, Page One Number 306 -SSR 2022-23 I No26.33 |
| 10 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. |
| 11 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering andscaffolding etc. Complete--Specification No--Bd.G.5 Page One Number 315 -SSR 2022-23 I No27.05 |
| 12 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc.complete.--Specification No--Bd. L.2 Page One Number 368 -SSR 2022-23 I No32.04 |
| 13 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.--Specification No--Bd.L.7 Page One Number 369 -SSR 2022-23 I No32.11 |
| 14 | Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete.--Specification No--Bd. P. I Page One Number 411 -SSR 2022-23 I No36.03 |
| 15 | Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete.--Specification No--Bd. P.2 Page One Number 412 -SSR 2022-23 I No36.04 |
| 16 | Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete.--Specification No--As directed by Engineer incharge -SSR 2022-23 I No33.31 |
| 17 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.--Specification No--Bd.C.8 Page One Number 278 -SSR 2022-23 I No23.04 |
| 18 | Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (AntiCorossive Paint)--Specification No--Bd. V. 19 Page One Number 559 -SSR 2022-23 I No41.56 |
| 19 | Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.).--Specification No--Bd.R.5, Page One Number 453 -SSR 2022-23 I No38.04 |
| 20 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear)--Specification No--BD-T-55 PageOne Number 510 -SSR 2022-23 I No39.25 |
| 21 | Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.)--Specification No--BD-T-53 PageOne Number 509 -SSR 2022-23 I No39.2 |
| 22 | Providing and fixing of colour coated Zincaluminium( R ) AZ150 (min150 gms /sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness (BMT ) (0.5 mm TCT ), Hi-strength steel withmin.550 MPa yield strength, metallic hot dip coated withAluminium-Zinc alloy (55% Aluminiumm 43.4% zinc 1.6% silicon) with COLORBOND (R ) steel quality super durable polyster paint coat ( with inorganicpigment). The paint shall have a total coatingthickness of nominal 35 mm, comprising of nominal 25mmexterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with sublet square fluting in the five pan at nominal 180-250 mmcenter- to-center. The end rib shall bedesigned for anti-capacity groove. and return leg. The feed material shouldhave coil manufacturers product details marked a regular interval.including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 |
| 23 | Supplying and erecting mains with 3x2.5 sq.mmFRLSHcopper PVC insulatedwire laid inprovidedconduit/trunking/insidepole/Busbarsor any other places as per specification No: WG-MA/BW SSR 1-3-6 |
| 24 | Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty SSR 2022-23 INo 2-1-7 |
| 25 | Pointwiring in for light/fan/bell in20mmmetal conduitwith1.5 sq.mm (2+1E) FRLSHgrade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW SSR 2022-23 I No 1-7-1 |
| 26 | Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. OH-PL/STP SSR 2022-23 INo 8-1-1 |
| 27 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP SSR 2022-23 Ino 9-1-1 |
| 28 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP SSR 2022-23 I No 9-1-4 |
| 29 | Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated shortcircuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB SSR 2022-23 Ino 5-3-6 |
| 30 | upplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated shortcircuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB SSR 202-23 Ino 5-3-7 |
| 31 | Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. SSR 2022-23 INO 6-1-6 |
| 32 | Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010 SSR 2022-23 I No 6-1-14 |
| 33 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG PW/CW SSR 2022-23 I No 1-7-26 |
| 34 | Supplying and erecting regular/standard model ceiling fan of 900/1050mm. sweep complete erected in position as per specification no. FG-FN/CF SSR 2022-23 Ino 2-10-2 |
| 35 | Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board. SSR 2022-23 INO 5-3-14 |
| 36 | Royalty For Sand |
| 37 | Royalty For All Other Murum & 80mm Metal |
| 38 | Material Testing MIX DESIGN M-20 Concrete Concrete Mix Design (With all Tests on basic materials) |
| 39 | CONCRETE CUBE TEST For M-10 (Compressive Strength OF C.C. Cube (Set of 3 cubes)) |
| 40 | CONCRETE CUBE TEST For M-20 (Compressive Strength OF C.C. Cube (Set of 3 cubes)) |
| 41 | BRICK TEST (Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5 Bricks), Efflorescence) |
| 42 | BASIC TEST OF CEMENT.(Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness.) |
| 43 | STEEL BAR TESTING (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.) |
| 44 | BASIC TEST OF AGGREGATE.(Water Absorption, Specific Gravity,Impact Value, Crushing Value.) |
| 45 | FINE AGGREGATE.(Fineness Modulus ( Sieve Analysis ),Silt & Clay Content) |
| 46 | SOIL / MURUM (Sieve Analysis.) |
| 47 | Liquid limit & plastic Limit. |
| 48 | Compaction Test ( Proctor Density ) Please Enable Macros to View BoQ information |