|
| 1 | MAINTENANCE |
| 2 | OD342838/2025-2026:SITC of LED tube light on round block/Bracket 1200 mm LED (TMC100) lamps tube light fittings made of CRCA with 0.5mm thickness complete with all accessories and double side pin type single piece indoor LED Tube ,poly carbonate body (cool white at 6500 K temperature ) 1200 mm, G13 base 18 w with extruded aluminum heat sink with nominal system level lumen package of min 2100 Lumen having efficiency of minimum 115 lumen/watt, inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. etc and extruded Aluminium heat sink etc . The light should have minimum 70% of light at 40000 Hr life time as per relevant NABL Accreditation certification(LM 70& 80). Fittings directly fixed on wall or ceiling with PVC round block neatlypainted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections etc as required.( philips or equallant make ) |
| 3 | OD352662/2025-2026:Supply and fixing of 20 W LED tube in the existing CRCA sheet fitting etc as required. |
| 4 | OD352840/2025-2026:Supply Conveyance, installation, testing and commissioning of 6W LED bulk headfittings suitable for surface and wall mounting output greater than 115 lumen/W 6500K with IP 66 protection and IK09 protection with power factor greater than 0.95 atfull load, internal surge protection up to 4 KV,and corrosion proof LM6 gradepressure die cast aluminum body & poly carbonate diffuser cover complete withTHD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired upfor use on 230 V AC supply. including fixing as required Philips endura or itsequivalent |
| 5 | OD369156/2025-2026:Supply and fixing B-22 Type 3 W LED warm white bulb , in Existing batten holder philips or equqllqnt make etc. as required. |
| 6 | OD352661/2025-2026:Supply and fixing 7 W LED bulb in the existing batten holder etc as required. |
| 7 | OD369148/2025-2026:Supply and fixing PVC Batten/Angle Holder with 9W LED bulb and aluminum shade and giving connection etc as required. |
| 8 | 90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 9 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 10 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 11 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 12 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 13 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 14 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 15 | 90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator |
| 16 | 90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator |
| 17 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 18 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 19 | 1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 20 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 21 | 1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) |
| 22 | 1.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm) |
| 23 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 24 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 25 | OD369170/2025-2026:Urgent maintenance of Electrical installation including attending petty repairs , cleaning, of light fittings ,ceiling fan and exhaust fan ,checking all electrical connection in the DB and switch board. |
| 26 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 27 | 1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 28 | 90.6.5.9:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sq mm |
| 29 | OD352835/2025-2026:Supply, Conveyance,Testing and Commissioning of vertical wall mounting type 5 star rated 6 litres Instant Water Heater, 3 KW ,copper container with puff insulation and PVC body working on 230 Volt 50 Hz A/C supply , fixing on wall using suitable size anchor bolt / Screws etc and giving connection of water line and electrical supply. (Make Racold 6 litres Instant Water Heater, Pronto Stylo(491213632) or its equivalent). |
| 30 | OD369161/2025-2026:Supply and replacing of 2000 W Heating coil suitable for water Heater Geyser as required |
| 31 | OD369165/2025-2026:Supply and replacing of Geyser Capillary Thermostat and Cut Out, Capillary Thermostat Suitable for existing Geyser 5to 50 Liter with 1 Year Warranty etc as required |
| 32 | OD369179/2025-2026:Maintenance and servicing of 1TR/ 1.5TR/ 2TR/ 3 TR,240/415V , High Wall/ FloorMounting type Split Air Conditioner Units covering all routine and preventive maintenance , attending to all breakdowns and rectifying the defects if any (including the cost of spares and filling of sufficient quantity of Freon R-22,R-32 ,R -410A Gas) . The cleaning and servicing of IDU and ODU includes 1No. water servicing using chemicals, water pump etc. Air servicing using cleaning materials and pressure air pump etc. The operating status of the units should be regularly monitored and intimated to the department staff in charge and the Air conditioner Units should be maintained in proper working condition through out the period of contract. |
| 33 | OD369180/2025-2026:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer -in-Charge. Internal work -Exposed on wall25 mm nominal dia pipes |
| 34 | OD369172/2025-2026:Supply of Distilled/Deionized Lead acid battery water (5 Liter Bottle) Please Enable Macros to View BoQ information |