| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m all kind of soil |
| 2 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. Complete |
| 3 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) Footing |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) Plinth Beam |
| 8 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Coloumn |
| 10 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 11 | Providing& applying a coat of residual petrolium bitumen of grade of vg-10 of approved qualityusing 1.7 kg per sqm on dpc after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Lintal Bend + Sunshade |
| 15 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Slab Beam |
| 16 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Slab |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting,Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 18 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 19 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works (Z Section) |
| 20 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works (MS Grill) |
| 21 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 22 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete 100x75x3.5 mm |
| 23 | Providing and fixing I.S.I. mark oxidised M.S. tower bolt finish (Barrel type) with necessary screw etc complete (150 x 100 mm) |
| 24 | Providing and fixing I.S.I. mark oxidised M.S. Sliding door bolt with nut and screw etc complete (250 x 16 mm) |
| 25 | Providing and fixing I.S.I. mark oxidised M.S. Handles conforming to with nut and screw etc complete (100 mm) |
| 26 | Providing and fixing aluminium work for doors section of approved makes confirming to IS:1285, fixing with dash fastner of required dia and size ,including necessary filing up the gaps at junction i.e. at top bottom and sides with required EPDM rubber/neoprene gasket etc.Aluminium section shall be smooth rust free , straight ,mitred and jointed mechanically wherever required including cleat angle .Aluminium snap beading for glazing/panelling C.P. brass/stainless steel screw all complete as per arhitectural |
| 27 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes |
| 28 | Providing and fixing 1mm thik M.S sheet door with frame and diagonal braces of 40x40x6 mm. (1 1/2' x1 1/2'x1/4') angle iron , 3.15 mm.(1/8')gusset plates at the junctions & corners ,hooks at top ,25 mm.(1'), dia. Pulleys at bottom ,40x40x6 mm.(1 1/2' x1 1/2'x1/4') angles & T iron guides at top & bottom respectively including locking arrangement with handles,etc. complete and applying one priming coat of approved lead point. |
| 29 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand) |
| 30 | 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) |
| 31 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand) (Bearing Plaster) |
| 32 | 12 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand) Sunshade Plaster |
| 33 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 34 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 35 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 36 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 37 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height includingcleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 38 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm |
| 39 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete Size of Tile 600x600 mm |
| 40 | Kota Stone flooring over 20mm thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1:4 |
| 41 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 42 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 43 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete |
| 44 | Providing and fixing U. p.v.c rain water pipe 110mm dia with shoe,door bend etc. |
| 45 | Providing and fixing of wall face unplastiside PVC mold fitting accessories for unplastiside rigid PVC rain water pipe coforming including joint with seal ring conforming to leaving 10 mm gap to thermal expension Cuppler (110 mm) |
| 46 | Providing and fixing of wall face unplastiside PVC mold fitting accessories for unplastiside rigid PVC rain water pipe coforming including joint with seal ring conforming to leaving 10 mm gap to thermal expension Shoe Plain (110 mm) |
| 47 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 48 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 49 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) |
| 50 | Appron WorkSupply and filling of Moorum soil in plinth protection /appron |
| 51 | Brick work in 1:4 cement:sand moratr in Appron |
| 52 | Lean concrete in 1:4;8 in appron |
| 53 | 25 mm p.c.c.flooring in 1:2;4 |
| 54 | Providing & fixing Glass sttirups in flooring |
| 55 | Appron DrainEarth work in exacavation in trenches for foundations land for pipes cables etc. in ordinary soil (loan clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. |
| 56 | Providing and laying in cement concrete 1:4:8 (1 cement :4coarse sand :4 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form-work, in foundation and floors. Same as above but 1:4:8 |
| 57 | Class 150 Brick Work in 1:4 cement and coarse sand of 2.20 fineness modulus mortar in foundation and plinth including supply of all materials, labour and tools and plants etc. required for proper completion of the work. |
| 58 | 12 MM Th. Cement plaster 1:3 (cement & C.sand) with Neat Cement Finish |
| 59 | Centering and Shuttering including strutting ,propping etc.and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 60 | Centering and Shuttering including strutting ,propping etc.and removal of form for Small lintels not exceeding 1.5 m clear span moulding as in cornices ,window sills ,string coures, bands,copings,bed plates anchor blocks and the like |
| 61 | Centering and Shuttering including strutting ,propping etc.and removal of form for Colums ,pillars,piers,Abutments,posts and struts |
| 62 | Centering and Shuttering including strutting ,propping etc.and removal of form for Suspended floor ,roof, landings ,balconies and access plateform |
| 63 | Lab WorkProviding and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete |
| 64 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P. brass waste and 40mm CP brass tap with necessary CP brass union complete, inc painting of fitting and brackets, cutting and making good (600x450) |
| 65 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all 15 mm nominal outer dia Pipes |
| 66 | Providing and fixing U. p.v.c rain water pipe 75mm dia with shoe,door bend etc. |
| 67 | Providing and fixing Brass bib cock of approved quality and colour. 15 mm nominal bore, 165 mm long, weighing not less |
| 68 | Internal Sanitary & Water SupplyProviding and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. |
| 69 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required . |
| 70 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 71 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 72 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 73 | Providing and fixing P.V. C. Pipe 6kg.Pis including all Material, Labour T.&P. Complete of work. 110 mm dia. |
| 74 | Providing and fixing P.V. C. Bend including all Material, Labour T.&P. Complete of work. For 110 mm dia. |
| 75 | Providing and fixing P.V. C. N Trape including all Material, Labour T.&P. Complete of work. 100*100mm. |
| 76 | Providing and fixing of P.V.C. Copler For 110 mm dia. |
| 77 | Providing and fixing of P.V.C. Tee For 110 mm dia. |
| 78 | Providing and fixing of P.V.C. Door Bend For 110 mm dia. |
| 79 | Providing and fixing of P.V.C. Clamp For 110 mm dia. |
| 80 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 15 mm dia. nominal bore |
| 81 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 20 mm dia. nominal bore |
| 82 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 25 mm dia. nominal bore |
| 83 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore |
| 84 | Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length 15 mm nominal bore |
| 85 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 20 mm nominal bore |
| 86 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 25 mm nominal bore |
| 87 | Cutting holes upto 30x30 cm in walls including making good the same : With F.P.S. bricks. |
| 88 | Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. |
| 89 | Providing and fixing C.P. brass Piller cock Sencered of approved quality conforming to IS:8931 as such Hindwair 15 mm nominal bore. |
| 90 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore. |
| 91 | Providing and fixing C.P. brass long body /shortbody bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. as Such Hindwair 15 mm nominal bore |
| 92 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 as Such Hindwair 15 mm nominal bore |
| 93 | Providing and fixing of C.P. towel rod 24\\"heavy. |
| 94 | Providing & Placing of polyethylene waterstorage tank, ISI 12701 locking arregment and making necessary holes for inlet, outlet and overflowpipes but without fittings. (10000 for fire) |
| 95 | Providing & Making of Platefom for 5000 Ltr. P.V.C. Water Storege Tank. |
| 96 | Providing & Fixing of Disable Toilet Kit set complete such as make Hindwair or Eq. |
| 97 | Civil External Service ConnectionConstruction of Manhole 60x60x75 cm size complete |
| 98 | Construction of Sewer line 150mm dia complete |
| 99 | Providing and laying G.I. pipe 32mm dia for water supply |
| 100 | Boring WorkBoring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart bore log, including hire & running charges of all equipments, toois, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 300 mm dia |
| 101 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia |
| 102 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia |
| 103 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 104 | Development of tube well in accordance with IS: 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit) with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, ic disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 105 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 100 mm dia |
| 106 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 100 mm clamp. |
| 107 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubeweli as per IS:2800 (part 1). 100 mm dia. |
| 108 | Supply of submersible pump of make KSB 1.0 HP with control panel, support wire etc. complete. |
| 109 | Providing 2 core PVC insulated submersible cable from pump panel to submersible pump |
| 110 | Providing and foxing GI pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore |
| 111 | Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) |
| 112 | Construction of Septick tank 50 USER Size as per ISI Standered 5.00x1.60x1.40Earth work in excavation in foundation/tank |
| 113 | Base concrete in 1:4:8 cement:sand:stone ballast |
| 114 | Brick work in 1:4 cement:sand mortar in septick |
| 115 | Brick work in 115mm wall in 1:4 cement : sand mortar |
| 116 | R.c.c. work in 1:1.5:3 cement:sand:stone grit in Slab and beam |
| 117 | Providing cutting beding MS bar Reinforcement in slab |
| 118 | 20mm plaster in 1:3 cement:sand mortar with neat cement finish |
| 119 | P.c.c. in 1:2:4 cement:sand :stone grit in base to making slope |
| 120 | Providding and fixing C.I. man hole chembar 600x600mm size in slab |
| 121 | Providing and fixing C.I. vent pipe 100mm dia |
| 122 | Providing and fixing c.i. cowel guard 100mm dia |
| 123 | Providind and fixing 150mm dia inlet and out let pipe |
| 124 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 125 | Electrification WorkSchedule Rate - (As per CPWD - DSR (E&M) -2022)Wiring for light point/fan point /exhaust fan point /call bell/Sodium point with 1.50 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable G I box and earthing the point with 1.50 sq. mm FRLS PVC insulated copper conductor single core etc. as required. Group C |
| 126 | Wiring for Circuit/Submain wiring along with earth wire with the Following size FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 127 | Wiring for Circuit/Submain wiring along with earth wire with the Following size FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire |
| 128 | Wiring for Circuit/Submain wiring along with earth wire with the Following size FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required. 2 x 6 sq. mm + 1 x 6 sq. mm earth wire |
| 129 | Wiring for Circuit/Submain wiring along with earth wire with the Following size FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required. 4 x 10 sq. mm + 2 x 6 sq. mm earth wire |
| 130 | Supplying and Drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed medium class PVC conduit as required. Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 131 | Supplying and fixing 5 A to 32 A rating, 250 / 415 V, 10 Ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. required. Single pole |
| 132 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. required. 40 Amp. |
| 133 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface / recess, complete with tinned copper bes bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, double door |
| 134 | Supply and fixing of Following way , surafce / recess,Vertical type ,415 v TPN MCB distribution board of sheet steel , dust protected duly powder painted , including of 200 a tinned copper bus bar , comman neutal link , earth bar , din bar for mounting MCBs etc. as required 4 way(4+12) Double door |
| 135 | Supply and fixing of Following way , surafce / recess,Vertical type ,415 v TPN MCB distribution board of sheet steel , dust protected duly powder painted , including of 200 a tinned copper bus bar , comman neutal link , earth bar , din bar for mounting MCBs etc. as required 63 amp FP isolator |
| 136 | Installation, testing and commissioning of ceiling fan, including wiring of the down rods of standard length (upto 30 cm) with 1.50 sq. mm, FRLS PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc.. as required. |
| 137 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc.. as required. Upto 450 mm sweep. |
| 138 | Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 139 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junctiorpox/ wooden block including connections etc. as required. Each |
| 140 | Supplying and fixing brass batten/ angle holder including connection etc. as required |
| 141 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but modular plate etc. as required. |
| 142 | Schedule Rate - (As per UPPWD - 2024-25)Supply & Laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. Including excavation and refiling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25 sq.mm x 3½ core. |
| 143 | Supply and fixing of recess / surface mounting round 10 to 15 Watt cut out min 150 mm, Height Min 40 mm, LED Down lighter having with heat sink, diffuser die cast aluminium housing with heat sink, diffuser/Reflector and driver set, suitable for 24 Hr. Continuous Operation, complete in all respect. CAT: AAA, 1980 - 2200 system lumens, 110 lm/W, PF>0.95, THD<10%, at full load, CRI>80, with 5 year warranty. |
| 144 | Supply and fixing of LED Tube Light with Metal heavy duty Box type batten light fitting 2 x 22 Watt suitable for upto 2 X 22 W LED Polycarbonate tube light complete including tube etc. on surface complete in all respects. CAT: AAA, 2420 system lumens, 110 lm/W, PF>0.95,THD<10% at full load, CRI>80, Tube with aluminium heat with 5 year warranty. |
| 145 | Supply and fixing of LED Tube Light with Metal heavy duty box type batten Light fitting 1 x 22 watt suitable for upto 1 x 22 watt LED Polycarbonate tube light complete including tube suitable for both surface & suspended complete in all respect. 2420 system lumens, 110 Lm/watt, PF > 0.95, THD<10%, at full load CRI>80, Tube with aluminium sink hit with 3 year warrantee Cat AA |
| 146 | Supply and fixing of water tight oblong 10 watt LED bulkhead luminaire having die cost housing with driver set confirming to IP 65 and above protection. complete in all respect. 1100 system lumens, 110 Lm/watt, PF > 0.95, THD<10%, at full load CRI>80, with 3 year warrantee Cat AA |
| 147 | Supply and fixing of LED Street light fitting having die cast aluminium body and diffuser with driver set suitable for 60 to 72 watt. Confirming to IP 66 and above Protection complete in all respect. 7200-8640 system lumens, High power LED with lenses, 120 Lm/watt, PF> 0.95, THD<10%, at full load, CRI>70, > 440 V & >300 V autocut & restarts feature with 5 year warrantee Cat AAA |
| 148 | Schedule Rate - (As per UPPWD - 2018)Supply and fixing of 16 gauge M S drum with louvers duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respects . |
| 149 | S&F of Fire extinguisher, ABC Type 6.00 Kg. capacity (ISI marked IS: 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 150 | S&F of Co2 type Fire extinguisher, 4.5 Kg. capacity (ISI marked IS: 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 151 | Supply and fixing of hexagonal / round G P fan box of approved make made up 1.0 mm thick ISI Marked G.P. sheet spot welded four to Eight holes of 25.40 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.50 mm G P sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S. bar x 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting along with supply of all material, labour, T&P etc. required for proper completion of work. |
| 152 | Supply and fixing of 100 Amp. Four pole Change over switch on 50 mm x 50 mm x 6 mm angle iron frame , including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. |
| 153 | Market Rate - (Non Scheduled Items) -Supply & Fixing of Fan Sheet of Backelite |
| 154 | S/F of LED Bulb 9 watt ISI |
| 155 | Supply & Fixing of light duties exhaust fan 12”dia ISI double ball bearing metalic Usha / Crompton/Bajaj make |
| 156 | Supply & Fixing of exhaust fan luvers 12”dia |
| 157 | S/f of ceiling fan 1200 mm sweep. Single star rated Usha / Crompton/Bajaj mak |
| 158 | S/F of Kit-Kat fuse 63 Amp with neutrail link ,wooden ply board ,Hole fasner with connection |
| 159 | S/F Required Lugs, Gland ect. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail