| 1 | E/WORK IN EXCAVATION OVER AREAS |
| 2 | i) All kinds of Soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m |
| 4 | Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil |
| 5 | SUPPLY FILLING SAND |
| 6 | i) Local Fine Sand within grading zone IV |
| 7 | CEMENT CONCRETE (CAST - IN - SITU) |
| 8 | ii) 1:1½:3(1 Cement :1½ Coarse Sand: 2 Graded stone aggregate of 20mm) |
| 9 | iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) |
| 10 | v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 12 | i) Foundations,footings,bases of column |
| 13 | RCC UP TO PLINTH LVL W/O CENT. & SHUTT. |
| 14 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 15 | FORM WORK,CENTERNG & SHUTTERING FOR RCC |
| 16 | i) Foundations,footings,bases of columns, etc. for mass concrete |
| 17 | iii) Suspended floors,roofs,landings,balconies, access platform and Shelves (Cast in situ) |
| 18 | STEEL REINFORCEMENT |
| 19 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 20 | BRICK WORK |
| 21 | i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH |
| 22 | viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH |
| 23 | Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks |
| 24 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 25 | Structural steel work in built up sections/ framed work in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cutting,hoisting,fixing in position & applying a priming coat of approved steel primer etc. as required. |
| 26 | KLIPPON GALVALUME SHEETING |
| 27 | i) Profile Sheet for roofing |
| 28 | ii) Plain Sheet for Ridges (500 - 600mm). |
| 29 | iii) Plain sheet for Flashings/ Aprons (Upto 600 mm) |
| 30 | RIGID PVC RAIN WATER PIPES |
| 31 | iii) 160 mm diameter |
| 32 | Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure. |
| 33 | CEMENT PLASTER WITH FINE SAND |
| 34 | i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) |
| 35 | Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm) |
| 36 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 37 | CONST. OF GRANULAR SUB-BASE |
| 38 | i) With material confirming to grade-I (size 75 mm to .075 mm) having CBR value - 30, Thickness as desired |
| 39 | Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). |
| 40 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to .075 mm) to wet mix macadam (WMM) specifications including premixing the material with water at OMC for all leads and lifts, laying in uniform layers with mechanical paver finisher in sub-base/base course on well prepared surface and compacting with vibratory roller of 8 to 10 ton capacity to achieve the desired density, complete as per specifications & directions of Engineer-in- charge |
| 41 | INTERLOCKING PAVER BLOCKS PLAIN FINISH |
| 42 | ii) M40 grade 80 mm thick Plain finish |
| 43 | Providing & fixing at or near ground level PRECAST CEMENT CONCRETE in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement:3 coarse sand) including the cost of required centering, shuttering complete. 1:1.5:3 (1 Cement : 1.5 Coarse sand : 3 graded stone aggregate 20mm nominal size) |
| 44 | PRE-CAST RCC MANHOLE COVER |
| 45 | i) L D- 2.5,Rectangular shape 600x450mm internal dimensions |
| 46 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and SW drain pipe 100 mm diameter, 1.8 m long complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 47 | Providing and fixing 700mm wide rain water gutter fabricated out of 1200mm wide Roll of 18 Gauge Aluminium sheets including MS clamp supports, fittings, fasteners etc. complete as per drawing . (NO joints shall be provided in the gutter and the same has to be fabricated from a continuous roll of Aluminium sheet) |
| 48 | S/F MS FOUNDATION BOLTS |
| 49 | v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate |
| 50 | Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen ≥ 2100lm. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc |
| 51 | E/WORK IN EXCAVATION OVER AREAS |
| 52 | i) All kinds of Soil |
| 53 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m |
| 54 | SUPPLY FILLING SAND |
| 55 | i) Local Fine Sand within grading zone IV |
| 56 | CEMENT CONCRETE (CAST - IN - SITU) |
| 57 | v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) |
| 58 | CENTERING AND SHUTTERING |
| 59 | i) Foundations,footings,bases of column |
| 60 | RCC UP TO PLINTH LVL W/O CENT. & SHUTT. |
| 61 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 62 | RCC UPTO 5 LVL IN WALL W/O CENT& SHUTT. |
| 63 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 64 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20 mm nominal size) |
| 65 | FORM WORK,CENTERNG & SHUTTERING FOR RCC |
| 66 | i) Foundations,footings,bases of columns, etc. for mass concrete |
| 67 | iii) Suspended floors,roofs,landings,balconies, access platform and Shelves (Cast in situ) |
| 68 | iv) Lintels, beams plinth beams,girders bressumers and cantilevers |
| 69 | v) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 70 | STEEL REINFORCEMENT |
| 71 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 72 | BRICK WORK |
| 73 | i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH |
| 74 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in: |
| 75 | ii) 1 Cement mortar 1:6 (1 cement : 6 Coarse sand) |
| 76 | RIGID PVC RAIN WATER PIPES |
| 77 | i) 75 mm diameter |
| 78 | CEMENT PLASTER WITH FINE SAND |
| 79 | i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) |
| 80 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 81 | EUROPEAN WC WITH VIT.CHINA CISTERN |
| 82 | i) W.C. pan with ISI marked white solid plastic seat and lid |
| 83 | WASH BASIN WITH ACCESSORIES |
| 84 | i) White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 85 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 86 | SOIL WASTE AND VENT PIPES |
| 87 | ii) 100mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989. |
| 88 | SELF CLEANSING TRAPS |
| 89 | i) 100mm inlet & 100mm outlet SCI S&S as per IS - 3989. |
| 90 | CPVC PIPES INTERNAL EXPOSED |
| 91 | iii) 25 mm nominal outer dia Pipes |
| 92 | CPVC PIPES CONCEALED |
| 93 | i) 15 mm nominal outer dia Pipes |
| 94 | ii) 20 mm nominal outer dia Pipes |
| 95 | GUN METAL VALVE WITH CI WHEEL |
| 96 | i) 25 mm nominal bore |
| 97 | iii) 40 mm nominal bore |
| 98 | Providing and fixing C.P. brass Pillar/ bib cock of approved quality conforming to IS:8931 -15 mm nominal bore. |
| 99 | Providing and fixing C.P. brass stop cock (concealed) of standard design & of approved make conforming to IS:8931 - 15 mm nominal bore. |
| 100 | P/L NP2 CLASS RCC PIPES |
| 101 | ii) 150 mm dia. R.C.C. pipe |
| 102 | PROVIDING INTERNAL WIRING |
| 103 | ii) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 104 | iii) Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. with modular switch, modular plate, suitable GI box |
| 105 | SUPPLY & DRAWING SUB-MAIN/POWER WIRING |
| 106 | i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire |
| 107 | ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire |
| 108 | iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire |
| 109 | S&F FOLL. ELEC. FITTINGS/FIXTURES |
| 110 | xii) Fan Regulator of stepped modular type |
| 111 | S & F EXHAUST FAN |
| 112 | i) 6\\" dia light duty, make Khaitan or equivalent |
| 113 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watt, having IP65 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc. |
| 114 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watt, having IP20 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports & reference/batch nos of LEDs & fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc. |
| 115 | S&F Ceiling fans |
| 116 | iii) 1200 mm sweep |
| 117 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 118 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 119 | P/F SS PRESS FIT DESIGN COUPLING/SOCKET |
| 120 | v) Coupling/socket for 42.70 mm outer dia pipe |
| 121 | P/F SS PIPES AISI 304 GRADE |
| 122 | ii) 22.22 mm OD SS pipe |
| 123 | BRASS TOWER BOLTS |
| 124 | i) 200x10 mm |
| 125 | WHITE VIT.CHINA URINALS |
| 126 | i) One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 127 | DOUBLE ACTION TYPE FLOOR SPRING |
| 128 | i) With stainless steel cover plate minimum 1.25 mm thickness |
| 129 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover |
| 130 | GUN METAL NON-RETURN VALVE |
| 131 | AL.WORK FOR DOOR/WIND.WITHOUT GLASS |
| 132 | i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections |
| 133 | iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 134 | GLAZING IN AL.DOOR/WIND ETC. |
| 135 | i) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 136 | iii) With float glass panes of 8.0 mm thickness (weight not less than 20kg/sqm) |
| 137 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). |
| 138 | 40mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand:4 stone aggregate of 20mm nominal size) finished with a floating cement coat of neat including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 139 | Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade. |
| 140 | Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete. |
| 141 | VITRIFIED FLOOR TILES |
| 142 | i) Flooring with size of Tiles 60x60Cm in cement mortar 1:4 |
| 143 | 6MM THICK CEMENT PLASTER WITH FINE SAND |
| 144 | ii) 6 mm cement plaster 1:3 (1 cement: 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. |
| 145 | Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 146 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 147 | Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm |
| 148 | S,E,T & COMM. SUBMERSIBLE WATER PUMP |
| 149 | ii) 33 LPM 100m head |
| 150 | BORING/DRILLING BOREWELL |
| 151 | iv) 300mm dia in all types of soil up to 90m depth below ground |
| 152 | xvi) 300mm dia in all types of soil 90m to 150m depth |
| 153 | SUP/LOWERING PVC SCREEN PIPE IN BORE |
| 154 | ii) 150 mm nominal size dia |
| 155 | Supplying, filling, spreading & levelling coarse sand of size range 1.5 mm to 2 mm, in the recharge pit, over gravel layer for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 156 | ERW FE410 MS PIPES IN BOREWELL |
| 157 | ii) 150 mm nominal size dia having minimum wall thickness 5.00mm |
| 158 | S/ F HDPE PIPES, IS 4984, FOR BOREWELL |
| 159 | vii) 40mm dia HDPE pipe for borewell upto a depth of 65m |
| 160 | E/WORK IN EXCAVATION OVER AREAS |
| 161 | i) All kinds of Soil |
| 162 | SUPPLY FILLING SAND |
| 163 | i) Local Fine Sand within grading zone IV |
| 164 | CEMENT CONCRETE (CAST - IN - SITU) |
| 165 | iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) |
| 166 | CENTERING AND SHUTTERING |
| 167 | i) Foundations,footings,bases of column |
| 168 | RCC UP TO PLINTH LVL W/O CENT. & SHUTT. |
| 169 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 170 | FORM WORK,CENTERNG & SHUTTERING FOR RCC |
| 171 | i) Foundations,footings,bases of columns, etc. for mass concrete |
| 172 | STEEL REINFORCEMENT |
| 173 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 174 | FLYASH BRICK WORK |
| 175 | i) 1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 176 | MARBLE/GRANITE- KITCHEN COUNTERS/SILLS |
| 177 | iii) Granite of any colour and shade having Area of slab upto 0.50 sqm |
| 178 | iv) Granite of any colour and shade having Area of slab over 0.50 sqm |
| 179 | Structural steel work riveted, bolted or welded in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 180 | CEMENT PLASTER WITH FINE SAND |
| 181 | i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) |
| 182 | Constructing brick masonry chamber for underground C.I. inspection chamber |
| 183 | ii) Inside dimensions 500x700 mm and 45 cm deep for pipeline with one or two inlets with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 184 | S & I OF HORIZONTAL AIR COMPRESSOR |
| 185 | iii) Horizontal air compressor Assembly of 5 HP (160-220 LITRES) including civil works |
| 186 | S AND L XLPE CU/AL ARMOURED CABLES |
| 187 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
| 188 | xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS |
| 189 | SUPPLY AND LAYING OF FLAT CABLES |
| 190 | i) 3core, 2.5 sq.mm copper Flat Cable for submersible pump |
| 191 | CABLE TERMIN. NONFLP DOUBLE COMP. GLAND |
| 192 | vii) 3 Core x 2.5 sq. mm |
| 193 | xviii) 3.5 Core x 50 sq. mm |
| 194 | CABLE TERMIN. - FLP DOUBLE COMP. GLAND |
| 195 | vii) 3 Core x 2.5 sq. mm |
| 196 | S&F, TESTING, COMMISSIONING FLP JUNC BOX |
| 197 | i) For cables 2.5 to 4 sqmm XLPE / AYFY |
| 198 | S& DRAWING EARTHING GI/CUSTRIP/GI WIRE |
| 199 | i) 50 x 10mm G.I. Strip |
| 200 | ii) 32 x 6 mm G.I.strip |
| 201 | v) 25 x 3 mm GI strip |
| 202 | CHEMICAL EARTHING - PIPE IN PIPE |
| 203 | ii) Current Capacity:15kA Primary Conductor(Inner pipe dia-20NB; Electrode Outer Pipe Dia-40NB Length of Concentric Pipes:3M |
| 204 | S & F FOLLOWING SAFETY EQUIPMENTS |
| 205 | i) Electrical insulating mats made of PVC Elastomer 3mm Thick & 1 mtr wide near swichboards, etc as per direction of Engineer In charge. Mat should conform to IS 15652 Class A - suitable for safe working voltage of upto 33 kV. Test certificate to be provided with supply. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. |
| 206 | ii) 6 mm thick chequered plate on cable trench inside swtich room, DG room, earthing pit including cutting, painting, lifting hooks, etc |
| 207 | iii) Supply and fixing of shock treatment chart in English, Hindi & local language framed in glass framework. |
| 208 | iv) 11 KV grade hand gloves, ISI mark |
| 209 | Supply and Installation of Flame Proof ESD Push Button |
| 210 | S& DRAWING 3CX2.5SQMM PVC CU CONDUCTOR |
| 211 | ii) \\"L\\" Pole |
| 212 | SUPPLYING & FIXING OCTAGONAL POLES |
| 213 | i) S/E of 7 Meter high galvanised Octagonal pole with top 70mm (A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 220 x 220 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides) |
| 214 | Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 215 | Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job) |
| 216 | Structural steel work in built up sections/ framed work in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cutting,hoisting,fixing in position & applying a priming coat of approved steel primer etc. as required. |
| 217 | Steel work in built up tubular (round,square or rectangular hollow tubes etc) trusses etc. including cutting,hoisting fixing in position and applying a priming coat of approved steel primer, including welded and bolted with special shaped washers etc. complete. |
| 218 | i) Hot finished welded type tubes |
| 219 | UPVC PIPE CLIPS |
| 220 | ii) 110 mm |
| 221 | Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.) |
| 222 | Supply and fixing of 30 W LED (Light Emitting Diode) light fixture with fittings and accessories for hoarding light purposes having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 223 | S&P ELECT CON 11/0.4 KV 25KVA TRANSFORM Please Enable Macros to View BoQ information |