| 1 | Work of Installation of 250 KV T/F In Place of 100 KVA T/F With All Accessories as per resspo norms. with cartage from store to site. |
| 2 | Work of Installation of 11 KV VCB I/C CTR 600/300/5A, 350MVA, 24 VOLT & O/G CTR 200/100/5A, 350 MVA, 1250 AMP With All Accessories as per respo norms with cartage from store to site. |
| 3 | Erection of Single/Double pole with 8.5/9 Mtr Long. PCC Pole by digging suitable pits in hard/soft soil/ rock and its back filling including concreting and grouting of pols and fixing of all accessories . Work shall be done as per respo specification. Grouting meterial to be provided by bidder with cartage from store to site. |
| 4 | Fixing of 11 KV FUSE SET with cartage from store to site. |
| 5 | Providing and Fixing of TOP CHANNEL. |
| 6 | Providing and Fixing of Dropper channel. |
| 7 | Providing & Fixing of Chemical Earthing for T/F ( netural & body) though GI Connecting strip (50x6mm) as per site requirement. |
| 8 | Providing & Construction of Plinth of Transformer with sand, raw material etc |
| 9 | Providing & Fixing of Fencing of Transformer with all material required material. |
| 10 | Providing & Installation of Henely type tailess units 500 Amp 650 volt consisting of 06 Nos. brass back entry, 06 nos U-Type spring contact made of copper, brass coupling with porcelain fitted on the G.I. sheet 16 SWG with arrangement of 01 Nos neutral. The Tailess fuse unit frame made of 65x65x6mm M.S Angle/Painted with fixing of all above things. The Tailess frame on the plinth 160/250/400/500/630 KV T/F with making the connection of T/F and line side completed work all material shall be provided by the Contactor. The frame of the tailess unit is to be grouted are depth of 2 feet below the ground level & there should be a gap of 1 feet between the ground surface & the main tsiless unit.(1 Tailess Unit Means Avg. 3 Circuits at 1 T/F) |
| 11 | Fixing of 11 KV DISC INSULATOR WITH DISC FITTING with cartage from store to site. |
| 12 | Fixing of MS cross bracing Angle as per norms with cartage from store to site. |
| 13 | Fixing of 11 KV PIN INSULATOR WITH PIN with cartage from store to site. |
| 14 | Fixing of 3 PHASE DISTRIBUSTION BOX with cartage from store to site. |
| 15 | Fixing of STAY SET with cartage from store to site. |
| 16 | Providing & Fixing of STAY WIRE 7/10 SWG |
| 17 | Providing & Fixing of LT LUG. |
| 18 | Providing & Fixing of CLAMPS WITH NUT& BOLT |
| 19 | Providing & Fixing of SUSPENSION CLAMP WITH I HOOK |
| 20 | Providing & Fixing of CONCERTING OF STAY SET |
| 21 | Providing & Fixing of LT PIERCING CONNECTOR |
| 22 | Providing & Fixing of MS NUT & BOLT OFF SIZE |
| 23 | Providing & Fixing of DEAD AND CLAMP WITH I HOOK |
| 24 | Providing & Fixing of CLAMP WITH BOLT |
| 25 | Providing & Fixing of DANGER BOARD |
| 26 | Providing & Fixing of EYE HOOK |
| 27 | Providing & Fixing of LT SHACKLE INSULATOR |
| 28 | Providing & Fixing of MS HOLDING CLAMP |
| 29 | Providing & Fixing of CONCERTING OF POLE |
| 30 | Providing & Fixing of T-OFF CHANNEL |
| 31 | Providing & Fixing of POLE CLAMP |
| 32 | Providing & Fixing of DISTRIBUTION CLAMP |
| 33 | Providing & Fixing of CONCERTING OF STAY |
| 34 | Providing & Fixing of MS WOODEN CLAMP |
| 35 | Providing & Fixing of GI PIPE 6\\" DIA |
| 36 | Providing & Fixing of HDPE PIPE |
| 37 | Laying of LT ABC 3X95+1X70+1X16SQMM with cartage from store to site. |
| 38 | Laying of LT ABC 3X120+1X95+1X16SQMM with cartage from store to site. |
| 39 | Laying of 11 KV 3X185 XLPE CABLE with cartage from store to site. |
| 40 | Laying of 11 KV 3X185 XLPE JOINTING KIT with cartage from store to site. |
| 41 | Laying of LT ABC 3X120 with cartage from store to site. |
| 42 | Laying of 1X400 XLPE CABLE with cartage from store to site. |
| 43 | FIXING OF V TYPE CROSS ARM with cartage from store to site. |
| 44 | FIXING OF X ARM HOLDING CLAMP with cartage from store to site. |
| 45 | FIXING & LAYING AL. BINDING WIRE with cartage from store to site. |
| 46 | FIXING OF AS ANGLE with cartage from store to site. |
| 47 | Binding , Sagging and jumpring etc. of ACSR WEASEL CONDUCTOR on the pole as per RESSPO specification and as per direction of engineer in charge it includes cost of labour, T & P Carrier etc. required for proper completion of work with cartage from store to site. |
| 48 | Binding , Sagging and jumpring etc. of ACSR RABBIT CONDUCTOR on the pole as per RESSPO specification and as per direction of engineer in charge it includes cost of labour, T & P Carrier etc. required for proper completion of work with cartage from store to site. |
| 49 | Binding , Sagging and jumpring etc. of ACSR PANTHER CONDUCTOR on the pole as per RESSPO specification and as per direction of engineer in charge it includes cost of labour, T & P Carrier etc. required for proper completion of work with cartage from store to site. |
| 50 | Dismenthing & Cartage of old and used all meterial & other accessories like conductor, Pole, AB cable, X arm etc Loading & Unloading at both end Received back from site to central store. |
| 51 | Dismenthing & Cartage of old and used 100 KVA T/F all rest meterial & other accessories Loading & Unloading at both end Received back from site to central store. |
| 52 | Dismenthing & Cartage of old and used 63 KVA T/F & all rest meterial & other accessories Loading & Unloading at both end Received back from site to central store. Please Enable Macros to View BoQ information |