| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed Heavy class PVC Conduit having wall thickness minimum 2.0 mm , with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (Make: Legrand Lyncus/ L&T Entice/ Anchor Roma Classic/ Panasonic Akina/ Crabtree Athena/ ABB Adiva/ Schneider Electric Clipsal & WIres Make: Finolex/ Anchor/ Polycab/ Plaza. |
| 2 | Group - C |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in excluding surface / heavy class PVC/steel conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Make: Legrand Lyncus/ L&T Entice/ Anchor Roma Classic/ Panasonic Akina/ Crabtree Athena/ ABB Adiva/ Schneider Electric Clipsal & WIres Make: Finolex/ Anchor/ Polycab/ Plaza. |
| 4 | Group - C |
| 5 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Make: Legrand Lyncus/ L&T Entice/ Anchor Roma Classic/ Panasonic Akina/ Crabtree Athena |
| 6 | 5/6 amp Modular switch |
| 7 | 5 pin 5/6 amp socket outlet |
| 8 | Fan regulator |
| 9 | Telephone socket |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. Make: Legrand Lyncus/ L&T Entice/ Anchor Roma Classic/ Panasonic Akina/ Crabtree Athena |
| 11 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 amps modular socket outlets and 2 nos 5/6 amps modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). Make: Legrand Lyncus/ L&T Entice/ Anchor Roma Classic/ Panasonic Akina/ Crabtree Athena |
| 12 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. Make: Legrand Lyncus/ L&T Entice/ Anchor Roma Classic/ Panasonic Akina/ Crabtree Athena |
| 13 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 , 3pin 5/6 amp modular socket outlet and 15/16 amp&5 /6 amp modular switch, connection etc. as required. Make: Legrand Lyncus/ L&T Entice/ Anchor Roma Classic/ Panasonic Akina/ Crabtree Athena |
| 14 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. Make: Legrand Lyncus/ L&T Entice/ Anchor Roma Classic/ Panasonic Akina/ Crabtree Athena |
| 15 | Supplying and fixing Computer board comprising 3 nos 5 amp modular switches & Sockets , G.I box 2 module for jack box and G.I Box 12 module for 5 amp switchs and 5 amp sockets comprising sheet cover for each 2 module metal box , one no computer jack (RJ-45)with shutter including connections etc as required. Make: Legrand Lyncus/ L&T Entice/ Anchor Roma Classic/ Panasonic Akina/ Crabtree Athena |
| 16 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required .Make:-Finolex/polycab/Plaza as approved by Er-In-Charge |
| 17 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 18 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 19 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 20 | 2 X 10sq. mm + 1 X 6 sq. mm earth wire |
| 21 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 22 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.Make:-Finolex/polycab/Plaza as approved by Er-In-Charge |
| 23 | 3 x 1.5 sq. mm |
| 24 | 3 x 4 sq. mm |
| 25 | 3 x 10 sq. mm |
| 26 | Supplying and fixing of following sizes of Heavy class FRLS PVC Conduit having wall thickness minimum 2.0 mm along with accessories in surface/recess including cutting the wall and making good as required. Make:- Diplast/BEC/Polyfit/AKG as approved by Engineer-In-Charge(for Networking, CCTV, Fire alarm etc.) |
| 27 | 25 mm |
| 28 | Supplying and fixing of DLP 105x50 mmPVC adaptable trunking on the exiting wall at required height from lower level for power connection, light connection and net working connection including partition chip flexible cover end cap Make:-Legrand / MK as approved by Engineer-in charge. |
| 29 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/ PVC conduit including conections,as required.Make:-Polycab/ Finolex/ Molex/ Digisol/ Commscope/ Legrand/ Dlink |
| 30 | Supplying and drawing of telephone cable of following size high conductivity copper conductor ,with high density polythylene insulation , paired ,polyster,and sheathedwith grey coloured, pvc compound telephone cables generally conforming to ITD specifications in the existing surface/recessed steel/ PVC conduit including conections,as required. Make:- Dlink/ Polycab/Plaza as approved by Er-In-Charge |
| 31 | 2 pair telephone Cable |
| 32 | Supplying and fixing 8-port 10/100/1000Mbps Unmanaged standalone gigabit switch in desk top (green ethernet) for getting blazing speed of giga bite that delivers power performance and reliability i.e increasing the speed of net work server in large in switching protocol storing and forwarding as required .Make:- D-Link(Code No DGS-1008A) Digilink/ Cisco as approved by Engineer-in-Charge. |
| 33 | Supplying and fixing Ding Dong bell suitable for single phase, 230 volts, complete as required.Make :-Anchor/ Great white/ Gold Medal |
| 34 | Supplying and fixing batten/ angle holder including connection etc. as required. |
| 35 | Providing, Installation, testing and commissioning of BLDC ceiling fan including five year warranty with socket type 2 module regulator,including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mmt win twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required.Five star rating . (Make: Usha Technix BLDC ISI/ Orient Echotech Prime/ Havells Efficiencia/ Bajaj Energos 26/ Anchor Ecobreez Urban 3 Blades/ Crompton Energion HS Groove Hyperjet only) .five year warranty |
| 36 | Ceiling Fan 1200 mm sweep. |
| 37 | Providing and installation exhaust fan of 300mm (L/D) size in the existing opening,including making the hole to suit the size of the above fan, making good thedamages, connections, testing and commissioning etc. as required. Make:- (Usha Aeroclean LD/ Orient Air Flow/ Crompton Drift Air Plus Metal Anti Dust/ Anchor Anmol Deluxe-R/ Havells Ventil Air DS Only). five year warranty |
| 38 | Exhaust Fan, Light duty, (Domestic) |
| 39 | Providing and installation exhaust fan PVC of 300mm (L/D) size in the existing opening,including making the hole to suit the size of the above fan, making good thedamages, connections, testing and commissioning etc. as required: Make:- Usha/Bajaj/Crompton as approved by Engineer-in-charge(Five year warranty) |
| 40 | Supplying and fixing exhaust fan louver shutter for 300 mm.exhaust fan on the existing wall,painting etc, as required, |
| 41 | Supply and fixing of surface led downlighter in 18 W (+/- 5%)watts in Round Shape with minimum system lumen efficacy of 100 lm/W and total luminous flux 1500 with Pressure Die cast Aluminium hOUSING and HET diffuser and polycarbonate mounting box P.F.>0.90 ,ATHD<15% ,CCT 6500K/4000K, CRI > 80,IP20 protection.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 220V to 240V .Fixture have Surge Protection 4 kV and inbuilt short circuit protection .Isolated Driver including ,cutting arrangement ,complete in all respect. Make Philips/Wipro/jaquar/ Panasonic or as approved by Engineer-in-Charge.(five year warranty) |
| 42 | Supplying and fixing LED batten 35 watt (+/- 5%)Watts, with clear glass cover with Aluminium housing optical material polystyrene and optical cover material polycarbonate having efficacy 130lm/W and luminious flux 4550 lumens having P.F.>0.95 with THD<10%. The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 6500 K with CRI of minimum > 80. The Input voltage range 23O VAC . Fixture have Surge Protection 4kV complete with all accessories, connections, testing and commissioning etc. Make:- wipro /Philips/Jaquar/ Panasonic as approved by Engineer-in-Charge (Five YEAR WARRANTY ) |
| 43 | Supply and fixing of Led fixture 1X4FT 33 W+/- 1W with Surface Mounted aluminium housing and Polycarbonate diffuser,minimum system efficacy of 100lm/W with P.F.>0.95 with THD<20% ,CCT6500 K,CRI 80,Surge Protection 2 Kv, IP20.The LED with Useful life of 50000 Hrs at L70. The Input voltage 230 volt AC .including ,hanging arrangement ,complete in all respect. Make Philips/Wipro/jaquar/ Panasonic or as approved by Engineer-in-Charge.(five year warranty) |
| 44 | Supply and fixing of 2X2 Led fixture 36 W (+/- 5%)Watts surface/recess mounted fixture with CRCA Housing with white powder coating with pc diffuser having efficacy 120lm/W and luminious flux 5040 lumens having P.F.>0.95 with THD<10%. The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 6500 K with CRI > 80. The Input voltage 230 Volt AC .Fixture have Surge Protection 4kV complete with all cutting, accessories, connections, testing and commissioning etc as: Make:- Philips/Wipro/jaquar/ Panasonic as approved by Engineer-in-Charge.(five year warranty) |
| 45 | Supplying and fixing street light LED 45 watt IP66 with G.I bracket die cast Aluminium housing with frame and toughened glass, pipe mounting 6500k, (Five YEAR WARRANTY ) and it should be compatible with specification e.i. Power Factor > .9, Harmonic Distortion<10% and efficacy >120 Lumens per wat and lumen out put 6500 lumens suitable for input voltage: AC 220-240 V, 50/60Hz with 5kv surge protection , complete with all accessories, connections, testing and commissioning etc. Make - Philips /JAQUAR /wipro/ Panasonic as approved by Engineer-in-Charge |
| 46 | Supplying and fixing , 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.) .Make:- L&T /Legrand/Hager / Schneider as approved by Engineer-in -charge. |
| 47 | Single pole 5-32 amp |
| 48 | Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of double poles in the existing MCB DB complete with connections etc. as required:-Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty) |
| 49 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts,10 KA residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:- L&T /Legrand/Hager / Schneider as approved by Engineer-in -charge. |
| 50 | 40 AMP |
| 51 | 63 AMP |
| 52 | Supplying and fixing of MCCB Four pole following rating and breaking capacity with thermal magnet in release complete with connection ,testing and commissioning etc as required. Make:- L&T /Legrand/Hager / Schinder as approved by Engineer-in -charge. |
| 53 | 63 amp -18KA. |
| 54 | Supplying and fixing of Segregated tripple pole and neutral 8 ways surface/ recess mounting, 7 Segment 415volts, TPN MCB distribution board of sheet steel, dust protected, dulypowder painted, with provision to mount FP-MCB incomer, DP MCB/RCCB sub-incomer ineach phase and SP MCBs as outgoing (but without MCB ’s and incomer),complete with tinned copper din-bar, wire-set, neutral link, earth bar, detachablegland plate, cable interconnections, including earthing etc. as required:-.Make:- L&T /Legrand/Hager / Schneider as approved by Engineer-in -charge. |
| 55 | Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar,din bar, detachable gland plate, interconnections, with appropriate rating copper lugs, gland , powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator. Make:- L&T /Legrand/Hager / Schneider as approved by Engineer-in -charge. |
| 56 | MCBDB 12WAY Double Door. |
| 57 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 58 | Providing and installation of following type of LED retrofit Lamp B-22 holder base with polycarbomate diffuser and aluminium heat sink including connections, testing and commissioning etc. as required. Make:- JAQUAR/ Wipro/ Philips as approved by Engineer-in-Charge. |
| 59 | LED LAMP 9 WATT |
| 60 | Supplying and fixing fan hook for existing ceiling fan |
| 61 | Installation of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 62 | Installatiomn of suitable size GI box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 63 | Installation of Computer board comprising 3 nos 5 amp modular switches & Sockets , G.I box 2 module for jack box and G.I Box 12 module for 5 amp switchs and 5 amp sockets comprising frame and cover plate for each 2 module metal box and 12 module metal box , one no computer jack (RJ-45) with shutter including connections etc as required. |
| 64 | Installation of 8-port 10/100/1000Mbps Unmanaged standalone gigabit switch in desk top (green ethernet) for getting blazing speed of giga bite that delivers power performance and reliability i.e increasing the speed of net work server in large in switching protocol storing and forwarding as required .Make:- D-Link(Code No DGS-1008A) Digilink/ Cisco/ as approved by Engineer-in-Charge. |
| 65 | Installation of Recess/Surface LED downlighter in Round/square Shape with minimum system lumen efficacy of 110 lm/W and total luminous flux 1500 with Pressure Die cast Aluminium heat sink with and HET diffuser and polycarbonate mounting box P.F.>0.90 ,ATHD<15% ,CCT 6500K/4000K, CRI > 80,IP20 protection.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 220V to 240V .Fixture have Surge Protection 4 kV and inbuilt short circuit protection .Isolated Driver including ,cutting arrangement ,complete in all respect. |
| 66 | Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (up to 45 cm) with 16/0.20 mmtwin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required. |
| 67 | Installation of exhaust fan in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: |
| 68 | Installation of LED batten 10/25/36/40 watt (+/- 5%)Watts, with clear glass cover with steel housing optical material polystyrene and optical cover material polycarbonate having efficacy 120lm/W and luminious flux 2000 lumens having P.F.>0.95 with THD<10%. The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 6500 K with CRI of minimum > 80. The Input voltage range shall be 150V to 270V . Fixture have Surge Protection 4kV complete with all accessories, connections, testing and commissioning etc. |
| 69 | fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 70 | Erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- |
| 71 | Erection of following 40/50/63 amp rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 72 | Erection of 63/100 AMP rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 73 | Erection of 4 pole MCCB Enclosure 4 pole suitable up to 125 amp DU100H/DU125H/DU100D/DU125D/DN0/DY12 with all accessories including connections, testing as required complete in all respect. Make:- L&T Cat. / Legrand/ Hager/ ABB as approved by Engineer-in -charge. |
| 74 | Erection of Segregated tripple pole and neutral 8 ways surface/ recess mounting, 7 Segment 415volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, with provision to mount FP-MCB incomer, DP MCB/RCCB sub-incomer ineach phase and SP MCBs as outgoing (but without MCB ’s and incomer),complete with tinned copper din-bar, wire-set, neutral link, earth bar, detachable gland plate, cable interconnections, including earthing etc. as required:- |
| 75 | Erection of MCB distribution board 8/12/16 way, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator |
| 76 | Dismantaling and Installation of split type Air conditioner 2/1.5 ton complete in all respect. as required |
| 77 | Dismantling of LED fitting,wire,sub main ,ceiling fan ,exhaust fan ,MCB ,MCCB,DP,RCCB etc. in all floors to the best satisfaction of Engineer-in charge Please Enable Macros to View BoQ information |