| 1 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 2 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 3 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. |
| 4 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete |
| 5 | (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm |
| 6 | (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) R.C.C. work in Plinth Band |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) . R.C.C. work in Lintel |
| 9 | As in item no. 6 above but for slabs [Using 1:1.5:3 (1 cement : 1.5 coarse sand : 3 stone aggregates )Mix concrete]. (M-20) |
| 10 | As in item no. 6 above but for beam [Using 1:1.5:3 (1 cement : 1.5 coarse sand : 3 stone aggregates )Mix concrete]. (M-20) |
| 11 | M-150 brick work in 1:4 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 12 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 13 | Same as in item no. 11above but in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of brick work as required and also including oneycombed brick work in thickness of wall more than 12cms. (1:4 cement : coarse sand) |
| 14 | Half brick masonry with (Class M-150 First Class Brick) in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 15 | Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia piles |
| 16 | TMT Fe-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 17 | 15mm cement plaster on plinth in single coat on rough side of single or half brick wall fof mix. (1) 1 cement : 4 coarse sand |
| 18 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M. 2.25 |
| 19 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand .F.M. 2.25 |
| 20 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 21 | Chequerred precast cemenconcret tiles 22 mm thick in foothpath &courtyard, jointedwith neat cement slurry mixed with pigment to match the shed of tiles , including rubbing & cleaning etc. complet on20 mm yhick bed of cement mortor 1:4 ( 1 cement : 4 coarse sand) |
| 22 | dark shed pigment using ordinary cement |
| 23 | 18 mm thick cement plaster in dado/ skirting in 1:3 consisting of one part of cement and 3 part of approved coarse sand laid in panels, finished with 3mm floating coat of neat cement and marble dust in ratio of 5:1 including supply of all materials labour T & P etc. required for proper completion of the work. |
| 24 | Supply & fixing 5 mm thick china white glazed tiles in flooring or in skirting or dado laid with 1 :3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials labours & tools etc, required for completion of the work. (size of tiles upto 300x 300 mm). |
| 25 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 26 | (a) 35 mm thick (Single Leaf) |
| 27 | (b) Add extra for Double Leaf |
| 28 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 29 | Providing & fixing of hold fast for chaukhats of doors and windows. |
| 30 | Providing & fixing of door / windows grill. |
| 31 | Z-Section steel windows (Openable) |
| 32 | Angle iron door chaukhat 40*40*5 |
| 33 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) |
| 34 | Finishing walls with water proofing cement paint of required shade New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 35 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Ceiling) |
| 36 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured |
| 37 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 38 | Same as item 28 above but on new wood surface. |
| 39 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. |
| 40 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm. |
| 41 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 42 | (a) 250 mm x 10mm |
| 43 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm |
| 44 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 45 | Suspended floors, roofs, landings, balconies and access platform |
| 46 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 47 | ELECTRICAL WORKS |
| 48 | SUBHEAD I- WIRING POINTS |
| 49 | Wiring points for light with 1.5 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copper conductor cable as |
| 50 | earth continuity wire and piano type switch etc. complete in all respects. |
| 51 | Same as item No.(1) but for fan and light duty exhaust fan. |
| 52 | Supply and wiring of submain 2 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FR PVC insulated multistranded copper conductor |
| 53 | cable as earth contunity wire etc. complete in all respects. |
| 54 | INSTALLA TEON OF LIGHT FIXTURES AND FANS |
| 55 | eresction and testing of ceiling fan and regulator for room height upto 3.5 mtsincluding supply of 3mm thick g.l down rod 19mm dia duly painted compiete in all respects |
| 56 | S/F OF HEXAGonal fan box with hexagonai side of approox 80mm in length fabriated from 16swgm.s. sheet incorporating 10mm bia m.s. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the r.c.c.roof before conceting along with supply of all materials labour t& p etc. for proper completion |
| 57 | Supply fixing of electronic fan regulator 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. |
| 58 | Supply & fixing of single wall light bracket made of brass on matching polished MDFEG board brass including connection etc. as required. |
| 59 | DISTRIBUTION BOARD |
| 60 | Construction of recess distribution of all sizes including cutting of brick work providing lintel of suitable size & thickness plastering etc. with supply of all materials,labour, T&P etc. required for proper completion of work. |
| 61 | 480x480x200 mm. size |
| 62 | Supply and fixing of factory fabricated M.S. box in existing sunk with Godrej type almirah cover with handle etc. fabricated from 18 SWG M.S. sheet duly painted with red oxide primer followed by two coats of synthetic enamel paint complete with necessary |
| 63 | conduit entry and DP/TPN; fixing arrangement and provision for compartment for loose wires, openable housing on the top and hold fast etc. including supply of all material, labour and T & P etc. required for proper completion of the work. |
| 64 | 480X480X200 MM.SIZE |
| 65 | Supply and fixing of flush/surface mounting distribution boards complete in all respects. |
| 66 | 6 way spn |
| 67 | Supply and fixing of 240 volts 'L' series miniature circuit breaker 6 Amp. To 32 Amp. (10 K A ) in existing MCB, DB complete with connections as required. |
| 68 | 5 - 32 amps. [CAT-C] |
| 69 | Supply and fixing of 32 Amp DPMCB (10 K.A.) complete with connections as required. |
| 70 | INTERNAL & EXTERNAL WATER SUPPLY & SEWERAGE WORKS |
| 71 | Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware /Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. |
| 72 | White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. |
| 73 | Providing & fixing stainless steel AISI 304 (18/8) kitchen sink without drain board 610x460 mm bowl depth 200 mm with PVC waste pipe etc. complete. |
| 74 | Kitchen sink |
| 75 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. |
| 76 | Semi rigid pipe |
| 77 | a) 32mm dia |
| 78 | b) 40mm dia |
| 79 | Providing and fixing wash basin with C.I. brackets, 15 mm dia C.P. brass Single Hole Basin Mixture approved quality and make ,including painting of fittings and brackets, cutting and making good the walls wherever require. |
| 80 | a) White Vitreous China wash basin size 550x 400 mm with 15 mm dia C.P. brass Single Hole Basin Mixture. |
| 81 | Providing and fixing UV stabilized UPVC soil, waste pipe with one end plain and other end socketed and provided with square grooves, specials such as Tees, Bends, Y junctions etc. All fittings are to be provided with square grooves & T shaped rubber rings. The jointing is to be completed with rubber lubricant and including making good wall and flooring wherever necessary. |
| 82 | The wall thickness of the pipe and other technical characterstics confirm to IS 4985 - 1988 6 Kg/Cm2 . The jointing to be completed with rubber lubricant. |
| 83 | a) 110mm dia PVC Pipe |
| 84 | b) 75mm dia PVC Pipe |
| 85 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. |
| 86 | a) 15mm dia nominal bore |
| 87 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 |
| 88 | a) 15mm nominal bore |
| 89 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 90 | a) Circular Tank |
| 91 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, |
| 92 | exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 93 | a) Pipes 80mm to 300mm diameter. |
| 94 | Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. |
| 95 | a) 100mm diameter |
| 96 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. |
| 97 | a) 100mm diameter S.W. Pipe |
| 98 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: |
| 99 | SEPTIC TANK & SOAK PIT SIZE OF TANK :- Length = 1.9 M. Width = 1.10 Total Depth =2.25M |
| 100 | Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality). |
| 101 | From 0.00 mt to 1.50 mt |
| 102 | 1.50mt to 3.0 mt |
| 103 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. |
| 104 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. |
| 105 | As in item no. 3 above but for slabs (Using 1:1.5:3 Mix concrete) |
| 106 | M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. BAFFLE WALL |
| 107 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 108 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). |
| 109 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 3 Coarse sand |
| 110 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 1729 |
| 111 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) |
| 112 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 113 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 114 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 115 | M.D. -10- Circular shape 500mm internal diameter |
| 116 | L.D. -2.5- Circular shape 450mm internal diameter |
| 117 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 118 | TUBE WELL AND INSTALLATION OF SUBMERSIBLE PUMP |
| 119 | External W/S arrangement, T.W. boring of 150mm dia with 100mm dia P.V.C. pipe assembly, 1.5 H.P. submersible pump including supply of all accessories starter, panel etc. & pipe arrangement etc. |
| 120 | 4\\" PVC pipe of ISI mark [14 Kg pressure] |
| 121 | P/F 2\\" GI pipe (B) class. |
| 122 | NYLon mesh for filter |
| 123 | Plastic dori |
| 124 | Solvent dori |
| 125 | 4\\" End cap |
| 126 | 4\\" Submersible Cap |
| 127 | 2\\" MS clamp (Heavy) |
| 128 | 2\\" Gl elbow. |
| 129 | 2\\"*6\\" GI nipple |
| 130 | 1.5 HP 9 Stage Submersible Pump of ISI mark With automatic panel. |
| 131 | 2.5 Sqm. Submersible cable. |
| 132 | Drilling Charges for 6\\" dia tubewell. |
| 133 | Pea Gravel |
| 134 | 2\\" Ms Socket. |
| 135 | Cartage of material upto site. |
| 136 | COST OF BRANDING |
| 137 | GST extra as per applicable Please Enable Macros to View BoQ information |