Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Material and Labour for Excavating in post holes (or similar holes)each not exceeding 0.5 cum.getting out in hard/ dense soil,returning, filling in and ramming earth or broken rubble mixed with earth around,in layers not exceeding 25 cm in hard/dense soil complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Material & Labour for PCC 1:3:6, Type C2, using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in-Charge. |
| 3 | Removing excavated material of any type of soil not exceeding 50m and depositing where directedc at a level n exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in- Charge. |
| 4 | Supply & Fixing Mild steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) Fe 410 -W (Gde- E- 250) quality-A including distance pieces, cleats etc. complete all as speicied and as directed by Engineer in charge. |
| 5 | Supply & Fixing Mild steel work as in MS plates (plain or chequered)square cut or notched (forming holes with riveted,bolted welded attechment) Fe 410-w(Grade-E-250) quality-A complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Supply & Fixing Mild steel work as in Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-In-Charge. |
| 7 | Supply & Fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Supply & Fixing Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge. |
| 9 | Material and labour for 75 mm thick PCC (1:3:6) Type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection / path etc. finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge |
| 10 | Material & Labour for 100 mm thick PCC 1:4:8 ,Type-D2 ,using 40mm graded stone aggregates as in sub base of flooring complete all as specified and directed by Engineer-in-Charge. |
| 11 | Material & Labour for 100mm thick plain cement concrete 1:2:4,Type B2 ,using 40mm graded stone aggregates as in sub base of floor complete all as specified and as directed by Engineer-in-Charge. |
| 12 | Material & Labour for Machine Pressed Precast Interlocking paver block with grey cement and no pigment, factory made, any shape and size, conforming to IS 15658-2006 of 60 mm thickness, made out of M-35 grade concrete laid over sand cushioining complete all as specified and as directed by Engineer-in-charge. Note:Sand cushioning shall be measured and paid seperately under approriate item of Schedule'A' BoQ. |
| 13 | Material and labour for Sand cushioning for laying bed for interlocking paver block including watering and consolidation complete all as specified and as directed by Engineer-in-charge. |
| 14 | Material & Labour for preparation of newely steel surfaces of any description, over 10 cm in width or girth or otherwise described , with and including applying two coat of syntheic enamal paint over with and including one coat of red oxide zinc chrome primer complete all as spefied and as directed by Engineer-in-Charge. |
| 15 | Material & Labour for Brickwork with sub class ‘B’ burnt clay old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Material and labour for Rendering 15mm thick in Cement Mortar 1:4 , on fair faces of brick work or concrete surfaces of walls , finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 17 | Material and labour for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge. |
| 18 | Demolition cement concrete (unreinforced) in ground floor and pavings not exceeding 15cm thickness below or above ground level with and including removing rubbish material from building and thrown in low lying empty area complete all as specified and as directed by Engineer-in-charge. |
| 19 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) with and including removing rubbish material from building and thrown in low lying empty area complete all as specified and as directed by Engineer-in-charge. |
| 20 | Material & Labour for 25 mm thick PCC in Cement Mortar 1:2:4 Type B-0 (using 12.5 mm graded stone aggregate) as in sub base of floor complete all as specified and directed by Engineer-in-Charge. |
| 21 | Taking down cement or cement lime plaster from brick wall or concrete surfaces etc including racking out joints, hacking for key & scrubbing down with water etc including removing rubbish material from site and thrown in low lying empty area (as per direcction of AGE/JE) complete all as specified and as directed by Engineer-in-charge. |
| 22 | Material & Labour for Virified Ceramic tiles Light shade 10mm thick (square/rectangular) polished, (shade as approved by Engineer-in-charge ) , area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured/ shade cement to match the colour / shade of tiles , laid over with and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 23 | Material & Labour for Virified Ceramic tiles Light shade ,10mm thick (square/rectangular) polished, (shade as approved by Engineer-in-charge ) , area of each tiles exceeding 0.36 Sqm but not exceeding 0.42 Sqm, in vertical surfaces etc. set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured cement to match the colour / shade of tiles , laid over with and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 24 | Material & Labour for Non skid ceramic coloured joint free tiles , thickness 7mm to 8mm thick (square/ rectangular), colour as approved by Engineer-in-charge area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floor etc set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured cement to match the colour / shade of tiles , laid over with and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 25 | Material & Labour for Gazed Coloured Ceramic tiles , size 300mm x 200mm / 450mm x 350mm x 7mm to 8mm thick, colour as approved by Engineer-in-charge as in vertical surfaces set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured cement to match the colour / shade of tiles , laid over with and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 26 | Material and labour for preparation of new surface of walls, with and including two coats of cement base paint ,over with and including one coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge. |
| 27 | Material and labour for preparation of old surface of walls, with and including two coats of cement base paint complete all as specified and directed by Engineer-in-Charge. |
| 28 | Dismantling of plain or corrugated steel sheeting any gauge, thickness including roof covering etc complete all as specified and directed by Engineer-in-Charge. |
| 29 | Dismantling wall and ceiling boards (fiber, Pulp, insulation etc) or insulation board/slabs/blankets, any thickness, including cover fillets & snap grid frame etc, complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply, delivery and fixing in position decorative hollow PVC wall paneling comprising 8 mm thick plain coloured pre-laminated PVC panels of approved make, shade and design, having tongue and groove interlocking arrangement, with and including fixed over rigid uPVC batten framework, complete all as specified and directed by the Engineer-in-Charge.The framework shall consist of uPVC battens of size 25 mm × 25 mm (outer) with minimum 2.0 mm wall thickness, hollow box section, manufactured from high-quality unplasticized PVC, termite-proof, waterproof and self-extinguishing type. Battens shall be fixed to wall surface using 8 mm dia nylon rawl plugs and GI/SS screws of suitable length, at spacing not exceeding 450 mm centre-to-centre in both directions, ensuring proper alignment, level and plumb. The PVC panels shall be fixed to the framework using approved solvent cement/adhesive and screws/nails through grooves (concealed fixing), ensuring tight interlocking joints and uniform finish. Panels shall be cut to required sizes and fixed vertically/horizontally as directed, without undulations.The item shall include providing and fixing all necessary accessories such as starter strips, corner profiles (internal/external), joint trims, end caps, beading and mouldings, as required for a complete and aesthetically finished work. All joints, edges and corners shall be properly finished.The work includes surface preparation, cutting, notching, making good, scaffolding, wastage, and all incidental charges, complete in all respects. |
| 31 | Supply and Fixing in replacement PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle , with and including brackets, with and including 32 mm dia flush pipe of polyethylene of low or high density of PVC complete all as specified and as directed by Engineer-in- charge. |
| 32 | Supply and Fixing in replacement vitreous china wash down water closet pan ( pedestal pattern ) white , with and including stainless steel Jet , with and including ‘P’ or ‘S’ trap , with and including seat cover complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and Fixing in replacement Vitreous china wash hand basin, Vitreous china white, flat back, size of 550mm x 400 mm with Mild steel brackets, with and including cutting for and pinning in ends of brackets or erecting stand, with and including waste fittings of brass chromium plated ,with and including 32mm dia PVC waste pipe of required length complete all as specified and directed. as directed by Engineer-in-Charge. |
| 34 | Supply & Fixing in replacement Powder Coated Anodised aluminium frame (minimum thickness of powder coating not less than 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge. Note: 1. During the weighing of aluminium section the weight of powder coating 50 micron shall not be considered. The payment shall be made only on the actual weight of aluminium section. 2. The rate of 50 micron powder coating is included in this item hence contractor shall quote his rate accordingly.Nothing shall be paid extra on this account.3. if the aluminium section provided at site with thickness of powder coating more than 50 micron by contractor nothing shall be paid extra. |
| 35 | Supply & Fixing in replacement Door shutter made of aluminium sections weighing 0.55 kg/Rm , Powder coated (coating not less than 50 micron ), of any colour (as approved by Engineer-in-charge) , with and including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws etc . complete all as specified and directed by Engineer-in-Charge. Note : 1. The rate of Glass is not included in this item and shall be measured and paid under appropriate items of Schedule of BoQ3. The rate of cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, etc. is included in this item and nothing shall be paid extra on this account.4. The rate of anodised aluminium fittings such as , hinges , handles , tower bolts, stopers, sliding bolt is not included in this item . The measurment and payment of these items shall be made under appropriate items of Schedule'A' BoQ. |
| 36 | Supply, fabrication and fixing in replacement and in position aluminium window / ventilator shutter (fixed type, without sash bar), made from extruded aluminium sections conforming to relevant IS standards, having section weight not less than 0.55 kg per running metre and overall weight not less than 5.50 kg/Sqm, powder coated with minimum 50 micron thickness in approved colour and shade, complete all as specified and directed by the Engineer-in-Charge.The shutter shall include outer frame and fixed glazing members, properly cut, mitred and jointed to form rigid construction, true to line, level and plumb.The item shall include providing and fixing of necessary joining cleats, glazing clips, EPDM/neoprene rubber packing, anodised aluminium snap beading, screws and fasteners, etc., complete for proper fixing of glass.The unit shall be fixed in opening using suitable rawl plugs, screws/fasteners, complete in all respects.Note : 1. The rate of glass for glazing and wire mesh cloth is not included in this item and shall be measured and paid under appropriate items of Schedule of BoQ2. The rate of cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, is included in this item .Contractor shall quote his rates accordingly . Nothing shall be paid extra on this account.3 Net opening will be measured for payment purpose . 4. No measurment shall be considered sepertely for each shutter.. |
| 37 | Material and Labour 5.5mm thick glazing sheet glass ordinary quailty in square exceeding 0.50 Sqm in each pane complete all as specified and as directed by Engineer-in-charge. |
| 38 | Supply and Fixing aluminium alloy, anodised, sliding door bolt of length 300 mm with hasp, staple (bolt type) (ISI Marked ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of sections or cast-aluminium extruded alloy and fixed complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and Fixing 200mm long aluminium anodised barrel tower bolts of extruded section (ISI Marked ) complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply and Fixing 150mm long aluminium anodised barrel tower bolts of extruded section (ISI Marked ) complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply and Fixing 150 mm long Extruded aluminium alloy handles, fabricated type,anodised (ISI Marked ) as specified and directed by Engineer-inCharge. |
| 42 | Supply and Fixing Mild steel 300mm size ordinary rat tail pattern springs (ISI Marked ) including roller and roller plate complete all as specified and directed by Engineer-in-Charge. |
| 43 | Supply and Fixing Floor door stopper of aluminium alloy body and tongue, anodised,with hard drawn steel spring,fixed in floor Overall length of cover plate 150mm complete all as specified and directed by Engineer-in-Charge. |
| 44 | Material and Labour for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and as directed by Engineer-in-charge. Note: The rates include for any extra form work if required to form joints as per SSR-2020. preamble (a) specified on serial page no.480 . |
| 45 | Material and Labour for Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'A' complete all as specified and as directed by Engineer-in-charge. Note: The rates include for any extra form work if required to form joints as per SSR-2020. preamble (a) specified on serial page no.480 . |
| 46 | Material and Labour for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide on rough finished surfaces of concrete complete all as specified and as directed by Engineer-in-charge. |
| 47 | Material and labour for concealed Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), in new PVC conduit complete with and including 1.5 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked , drawn through with and including new PVC rigid conduit 20mm dia ( heavy duty ) ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with all new fittings and all accessories i.e pipe bend pipe hook, elbow,junction box, pressed steel powder coated sunken box of suitable size (min 60mm deep, suitable length and 1.2mm thick ) and flush fixed with cement mortar 1:4 , 3mm thick bakelite plastic laminated sheet for mounting with frame and top cover for switches 5Amp/6Amp , socket outlet 5Amp/6Amp and fan regulator, for light point controlled by one way switch 5Amp / 6Amp, top cover fixed with brass screws & cup washers, with and including one single core 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) (as in green colour) as continues earth wire connected to earth dolly etc. with and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge . Continued in item No 47.01 |
| 48 | Contd from serial item no. 47.00Notes for serial item nos. 47.00 to 48.00 : (i) switches one way 5 /6 Amp , socket out lets 5 /6 Amp shall be measured and paid seperately under respective items of Schedule'A' BoQ.(ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface is included in this item and nothing shall be paid extra on this account. (iii) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clips as directed by Engineer-in- Charge.The rate of this element is included in this item and nothing shall be paid extra on this account. (iv) Serial item no.47.00 to 48.00 pertain to new provision hence schedule of credit shall not be considered for these items. |
| 49 | All as per serial item No 47.00 of BoQ here-in-before but for socket outlet 5 pin 5Amp / 6 Amp on independent board complete all as specified and directed by Engineer-in-charge. |
| 50 | Supply and fixing Switch piano flush type 5 Amp single pole one way ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 51 | Supply & Fixing Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal 240 volt (ISI Marked ) complete all as specified and directed by Engineer-in-Charge. |
| 52 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as manufacturer's instructions with and including connection with copper conductor of appropriate size as required at site as directed by Engineer-in- charge from pole to street light fitting. Note : The rate of connection with copper conductor of appropriate size as required at site as directed by Engineer-in- charge from pole to street light fitting is included in this item and contractor shall quote his rate accordingly . Nothing shall be paid extra on this account. |
| 53 | Supply and fixing ceiling rose surface bakelite 65mm x 50mm three terminals ISI Marked complete all as specified and directed by Engineer-in-Charge. |
| 54 | Supply and Fixing in replacement Decorative ultra slim linear LED 18 Watt 4 Feet Long lighting fixture with extruded aluminium heat sink,environment friendly, Energy efficient , ready to use pack with and including LED Tube complete , with inbuilt electronic driver, PCB, Connector block complete all as per manufactureres instructions with and including connecting up with theree copper flexible cable from ceiling rose to fitting including connectiong up and fixed on with and including two nos.square box of required size complete all as specified and directed by Engineer-in-charge. Notes:(a) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. |
| 55 | Supply and fixing MCB SPN 32 Amp , rupturing capacity not less than 10 KA 'C' curve 230 V AC, 50 Hz ,ISI Marked, with and including necessary attachment , thimbles etc. complete all as specified and directed by Engineer-in-charge. |
| 56 | Supply and fixing MCB SP 6 to 32 Amps, 230 volts , AC supply , rupturing capacity not less than 10KA,' C' Curve ,ISI Marked, with and including necessary attachment , thimbles etc complete all as specified and directed by Engineer-in-charge. |
| 57 | Supply and fixing in replacement sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated DB SPN 4 way 230 V AC with 200 Amp rated copper bus bar, Double Door, dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge.Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account. |
| 58 | Supply and fixing in replacement sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated DB SPN 16 way 230 V AC with 200 Amp rated copper bus bar, Double Door, dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge.Notes: (i) MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account. |
| 59 | Material and Labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia medium grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 60 | Material and Labour for in replacement earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia medium grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 61 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 10 Sqmm 2.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 62 | Supply and Laying GI tubing 40mm bore Light grade with all fittings such as clamps laid in trenchs or fixed on wall along pole including fixing arrangement , nut bolts, clamps etc.complete for protection of electic cable / strip complete all as specified and as directed by Engineer - in charge. |
| 63 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable , Pipes , etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil such as in any type of soil complete all as specified and as directed by Engineer-in- charge. |
| 64 | Returning filling in, approved soft/loose soil, including spreading , levelling, watering and well ramming in layers, each layer not exceeding 25cm in any type of soil complete all as specified and as directed by Engineer-in- charge. |
| 65 | Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note:- Punned thickness shall be considered for payment purpose) |
| 66 | Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge. |
| 67 | Material and Labour in replacement Sub main wiring with two single core of size 4.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked including cuttting, chasing and grouting , with and including non metallic rigid PVC conduit medium quality of size 25 mm dia conforming to 3537 Part-I ISI marked including all fitting such as Tee, Elbow, bend etc drawn in and including one single core of size 4.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked as in contineous earth conductor cable connected to earth dolly complete all as specified and as directed by Engineer-in- charge. (Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and as directed by Engineer-in- charge. Notes:-(a) Cost of PVC conduit , conduit accessories and earth wire included in sub main wiring. (b) Three single core 4.0 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked with and including non metallic rigid PVC conduit of size 25 mm ISI Marked dia shall be measured as one length. |
| 68 | Taking down carefully aluminum / copper point wiring on Teak Wood Batten / in conduit / with conduit / in casing and capping(light /Fan / socket or power) complete with and including taking down fittings such as switches, ceiling roses, pendants, Regulators, sockets, light fittings etc complete all as specified and directed by Engineer-in-Charge. Notes:(i) The weight of aluminium scrap, copper scrap and scrap iron for schedule of credit shall be ascertain by BOO as ordered by GE.The copy of BOO duly countersinged by GE shall be enclosed with final Bill.(ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface shall be measured and paid seperately under serial item nos.68.00 to 71.00 of BoQ. |
| 69 | Material and labour for concealed Point wiring for Modular fittings using approved colour coding as per IS (Red, Black and Green for single phase circuits), in new PVC conduit complete with and including 1.5 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked , drawn through with and including new PVC rigid conduit 20mm dia ( heavy duty ) ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with all new fittings and all accessories i.e pipe bend pipe hook, elbow,junction box,etc. of required size for light / fan point controlled by one way modular switch 5Amp / 6Amp, with and including one single core 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) (as in green colour) as continues earth wire connected to earth dolly etc. with and including modular metal flush boxes concealed with modular natural / white finish front plate with base plate for the mounting of modular switches, sockets and fan regulators etc. etc complete all as specified and directed by Engineer-in-charge. Continued in item no.68.01 |
| 70 | Contd from serial item no. 68.00Notes for serial item nos.68.00 to 71.00 : (i) The quoted unit rate is deemed to be inclusive of cost of metal flush boxes, modular white cover plates, modular frame plates, etc.However modular switches and ,modular sockets shall be measured and paid seperately under respective items of Schedule'A' BoQ. (ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface is included in this item and nothing shall be paid extra on this account. (iii) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clips as directed by Engineer-in- Charge.The rate of this element is included in this item and nothing shall be paid extra on this account.(ii) The rate of sunken box of required size is included in this item and nothing shall be paid extra on this account. |
| 71 | All as per srl item No.68.00 here in before but for Modular One 3 pin socket outlet, 5 Amps on the same board complete all as specified and as directed by Engineer-in-charge. |
| 72 | All as per srl item No.68.00 here inbefore but for Modular One 3 pin socket outlet, 5 Amps, independent complete all as specified and directed by Engineer-in-Charge. |
| 73 | All as per srl item No 68.00 of BoQ here-in-before but 2.5 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked with and including one single core 2.50 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) as continues earth wire connected to earth dolly etc for Modular 3 pin socket outlet 15 Amps with complete all as specified and directed by Engineer-in-Charge. |
| 74 | Supply & Fixing Modular switch 1 way 6A,1 module (ISI Marked) complete all as specified and directed by Engineer-in-Charge. |
| 75 | Supply & Fixing in Modular switch 1 way 16A,1 module (ISI Marked) all complete all as specified and directed by Engineer-in-Charge. |
| 76 | Supply & Fixing in Modular socket, 6A - 2/3 pin combined 2 modules (ISI Marked) complete all as specified and directed by Engineer-in-Charge. |
| 77 | Supply & Fixing in Modular socket 6/16A,2/3 pin, combined 2 module (ISI Marked) complete all as specified and directed by Engineer-in-Charge. |
| 78 | S&F in replacement LED luminaire round/squre shape 15 watts 220 V AC surface/recessed type with hight efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for foof ceiling/surface complete all as per manufacturer's instructions suitable for roof ceiling with and including connecting up with driver from ceiling rose with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. |
| 79 | Supply & Fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp complete all as per manufacturer's instructions suitable for roof ceiling with and including connecting up with driver from ceiling rose with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. |
| 80 | Supply and fixing in replacement sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated TPN, 4 Way 415 V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCBs / MCCBs/ Isolators, conforming to IS/IEC-61439-2:2011, BS-5484 dust and vermin proof, complete all as specified and directed by Engineer-in-charge. Notes:(i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account. |
| 81 | Supplying and fixing MCB TPN 40Amps -100 Amps , 415 Volt AC, 'C' curve, ISI Marked, rupturing capacity not less than 10KA, with and including necessary attachment , thimbles etc complete all as specified and directed by Engineer-in-charge. |
| 82 | Supplying and fixing MCB SPN 63 Amps , 240 Volt AC, 'C' curve, ISI Marked, rupturing capacity not less than 10KA, with and including necessary attachment , thimbles etc complete all as specified and directed by Engineer-in-charge. |
| 83 | Supply and fixing Batten fitting square profile type LED mirror light fiting 15 watt, 6000K, 2 Feet long polycarbonate body and all other accessories fitting arrangements all other accessories fitting arrangements complete all as per manufacturer's instructions with and including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector complete all as specified and as directed by Engineer-in-Charge. Notes:(a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. |
| 84 | Taking down old unsrviceable service cable/UG cable of cross-sectional area 35sq mm 3.5 core including old uservicable bricks/ PCC concrete cable cover all as specified and directed by Engineer-in- Charge. |
| 85 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 35 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 86 | Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail