Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | Demolishing lime concrete manually/by mechanical means and disposal of material within 50 metres lead as per direction of Engineer-in-charge. |
| 3 | Dismantling tile work in floors & roofs laid in cement mortar including stacking materials within 50 mtrs lead for thickness of tiles 10 mm to 25 mm. Contractor has to dismantle WPC tiles from roof mosaictiles any types of tiles as per the direction of Engineer-in-charge at all heights & levels. |
| 4 | Demolishing cement concrete including disposal of material within 50 mtrs lead in ( 1 : 3 : 6 ) or richer mix. |
| 5 | Demolishing RCC work including stacking of steel bars and disposal of unserviceable material with in 50 mtrs lead at all heights & levels. |
| 6 | Demolishing brick work including stacking of serviceable materials and disposal of unserviceable materials within 50 mtrs lead in cement mortar at all heights & levels. |
| 7 | Demolising stone rubble masonry including stacking of serviceable material and disposal of unserviceable material within 50 mtrs lead in cement mortar. |
| 8 | Dismantling Doors, Windows, clerestory steel / wood windows, MS Doors, Rolling shutters (steel) at all heights & levels including chowkhats, architrare hold fasts etc complete stacking within 50 mtrs lead. Area 3.00 SQM & below |
| 9 | Dismantling Doors, Windows, clerestory steel / wood windows, MS Doors, Rolling shutters (steel) at all heights & levels including chowkhats, architrare hold fasts etc complete stacking within 50 mtrs lead. Area beyond 3 SQM |
| 10 | Dismantling steel work in built up sections in angles, tees flats & channels including all gusset plates, bolts, nuts, MS frames/ladders/ supports/beams etc., cutting rivets, welding etc., including all labours at all heights and levels. |
| 11 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the materials within 50 mtrs lead of asbestos sheet /GS sheet. |
| 12 | Dismantling Aluminium/Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 13 | Dismantling C I or asbestos or PVC rain water pipes & fittings and clamps including stacking of the materials within 50 mtrs lead - For 100 mm dia pipe. |
| 14 | Dismantling GI pipes (external work) including excavation and refilling trenches after taking out the pipes including stacking of pipes within 50 mtrs lead. 15 to 40 mm nominal bore |
| 15 | Dismantling GI pipes (external work) including excavation and refilling trenches after taking out the pipes including stacking of pipes within 50 mtrs lead. Above 40 mm nominal bore |
| 16 | Dismantling of Flush tank, wash basin, water closet ITWC, ETWC, Urinals etc. as per the directions of the Engineer-in-charge. |
| 17 | Dismantling Bituminous road manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 18 | Collecting conveying of debris/building rubbish, earth and excavated rocks etc., complete from factory premises to outside upto 50 kms lead including loading, unloading, all labours, hire charges of machinery etc., complete. |
| 19 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed by Engineer-in-charge. All kinds of soil in foundation, trench etc |
| 20 | Preparation and consolidation of sub grade with surface vibrator/roller after excavating earth to an verage of 22.5 cm depth, including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. |
| 21 | Supplying and stacking at site. 90 mm to 45 mm size stone aggregate. |
| 22 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 23 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 8 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA). |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns, slabs etc. |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form work for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form work for Suspended floors, roofs, landings, balconies and access platform |
| 27 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 28 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size of Recycled Concrete Aggregate(RCA) upto 20%. |
| 29 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20%: 3 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 20%). |
| 30 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m. |
| 31 | Providing and laying in position cement concrete (cast in situ) of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) the concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. |
| 32 | Providing and laying of cementitious floor hardener @4 kg/m2 on the wet concrete surface with levelling and finishing of the concrete with mechanical trowel (Abrasion Resistance ~1.70 mm wear loss (IS:1237, Surface hardness Between 8 and 9 (Moh's scale) (IS:13630 Part 13), Compressive Strength ≥ 70 N/mm2 (IS:4031 Part 6) of Sika, Myk, Ardex Endura, STP,fosroc or equivalent As per the direction of engineer in charge. |
| 33 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 34 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge (The payment of RCC band and reinforcement shall be made for separately). |
| 35 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in Cement mortar 1:3 (1 cement : 3 coarse sand). |
| 36 | Making cut out opening in wall and making good with all finishing to prevent leakage/seepage of water at all heights and levels. sizes upto 1sqm |
| 37 | Making cut out opening in wall and making good with all finishing to prevent leakage/seepage of water at all heights and levels. beyond 1 sqm |
| 38 | 15 mm cement plaster on rough side of single of mix: 1: 4 (1 cement: 4 coarse sand) - For external walls |
| 39 | 12 mm cement plaster on single or half brick wall of mix: 1:4 (1 cement : 4 fine sand) - For internal walls |
| 40 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) including manufacturing sand and derived from recycled aggregate (RCA upto 20% ) : 3 graded stone aggregate 20 mm of recycled aggregate (RCA) upto 20% |
| 41 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 42 | Providing and fixing pre-fabricated composite panels or insulated panels for roofing. Sandwich panels manufactured with profiled color coated GI sheets duly sandwiched with PUF ( Polyurethane Foam ) insulation of 50 mm thickness with top sheet of 0.5mm thick and bottom 0.5mm thick,(+0.05 %) total coated thickness with zinc coating 120 grams per sqm asper IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Puf Density is 38kg/cum, at all heights and levels with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces Rate includes material, transportation, labour, tools, tackles, etc. complete as per the direction of Engineer-in-charge. |
| 43 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 44 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) |
| 45 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) |
| 46 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 47 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge. Pre-laminated particle board with decorative lamination on both sides |
| 48 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 49 | Providing and fixing of anodized aluminium grill (anodized transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design/pattern with approved standard section and fixed to the existing window frame with CP brass /stainless steel screws @200 mm centre to centre ,including cutting to grill proper opening size for fixing approved anodized aluminium standard section around the opening, all complete as per requirement and direction of Engineer in charge (Only weight of the grill to be measured for the payment). |
| 50 | Painting with synthetic enamel paint of approved brand and manufactureto give an even shade: Two or more coats on new work |
| 51 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 52 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 53 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) : 30 mm thick |
| 54 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/clerestory windows & cleresrtory other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.Frame size 45x85 mm. |
| 55 | Providing and fixing on wall face unplasticised Rigid PVC pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75mm dia |
| 56 | Providing and fixing on wall face unplasticised Rigid PVC pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110mm dia |
| 57 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls. 20 mm nominal outer dia Pipes |
| 58 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls. 25 mm nominal outer dia Pipes |
| 59 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) (b)20 mm nominal bore |
| 60 | Providing and fixing water closet squatting pan (Indian type W.C pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required (a)White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 61 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.a) W.C. pan with ISI marked white solid plastic seat and lid |
| 62 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 580 x 380 x 350 mm sizes respectively with standard flush pipe and C.P brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors |
| 63 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 64 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 65 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 66 | PU watreproofing coat : a) Surface Preparation - Before waterproofing treatment, surface preparation including final cleaning of the surface using wire brush, mechanical grinding and jet washing. B) Primer Coat - Providing and applying of two component, primer by mixing resin and hardner at a ratio of 1 : 3 and also thinned with water upto 100% by weight. Epoxy primer is applied @ 180 - 200grams per sqm. c) PU Waterproof Coating - Supplying and applying PU coating, Mechanical, Thermal, Chemical, UV and weather resistant properties based on elastomeric polyurea polyurethane hybrid chemistry, with minimum elongation of 280%, tensile strength of 2.7Mpa. The system consists of applying the waterproofing treatment to 1.6 kg/sq.m. The coating is to be continued from coving joint to end of parapet wall. Waterponding test : Post Completion of waterproofing activities, the substrate needs to be checked for water tightness & Leak free condition, to ensure it. Allow the water to flood on the treated area for about 48 - 72 hrs . |
| 67 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two Coats |
| 68 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content with water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 69 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 70 | Providing and fixing of face unplasticized rigid PVC rain water pipeof 160 mm dia (single socket pipe) including all fitting like GI clamp, bent, tee, clamp, screws ,cleat etc complete at all height and levels as per the dicrection of engineer in charge. |
| 71 | Making connection of GI distribution branch with GI main of the existing size by providing and fixing tee and other necessary fittings including cutting and threading the pipe, sealing the joints, etc., complete for 25 to 40 mm nominal bore. |
| 72 | Providing and fixing brass stop cock of approved design, quality and make 15 mm NB. |
| 73 | Providing and fixing brass ball valve with C I wheel of approved quality ( screwed end ) for 25 mm dia nominal bore with reducer if necessary at all heights & levels. |
| 74 | Providing & fixing 100 mm PVC gully, floor or nahani trap at all heights and levels. |
| 75 | Providing and fixing CP towel rod of Jaguar or equivalent 2 feet long including all labours lead lift etc., at all heights & floors. |
| 76 | Providing and fixing PVC waste and vent pipes conforming to IS 4985 of SWR quality 4 Kg & 6 Kg / Sq cm, pressure. The rate shall incude cost of all fittings like plain elbow, plain tee, plain Y, 4 way tee and all required necessary specials etc., complete. jointing with rubber ring and solvent joints providing MS brackets grouted in the wall and fasteners cutting and making good the walls and floors (pipes running expose in sanitary ducts) supreme or prince quality pipes. 75 mm dia |
| 77 | Providing and fixing PVC waste and vent pipes conforming to IS 4985 of SWR quality 4 Kg & 6 Kg / Sq cm, pressure. The rate shall incude cost of all fittings like plain elbow, plain tee, plain Y, 4 way tee and all required necessary specials etc., complete. jointing with rubber ring and solvent joints providing MS brackets grouted in the wall and fasteners cutting and making good the walls and floors (pipes running expose in sanitary ducts) supreme or prince quality pipes. 110 mm dia |
| 78 | Providing and fixing PVC waste and vent pipes conforming to IS 4985 of SWR quality 4 Kg & 6 Kg / Sq cm, pressure. The rate shall incude cost of all fittings like plain elbow, plain tee, plain Y, 4 way tee and all required necessary specials etc., complete. jointing with rubber ring and solvent joints providing MS brackets grouted in the wall and fasteners cutting and making good the walls and floors (pipes running expose in sanitary ducts) supreme or prince quality pipes. 150 mm dia |
| 79 | Constructing Brick masonry circular type manhole 0.91 mtrs internal dia at bottom and 0.58 m dia at top with 75 class designation FPS Bricks in cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) inside cement plaster 12 mm thick with cement mortar ( 1 : 3 ) ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement foundation concrete ( 1 : 3 : 6 ) mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm noninal size ) and making necessary channel in cement concrete ( 1 : 2 : 4 ) ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement all complete as per standard design for 0.91 m deep with SFRC cover and frame ( heavy duty, HD - 20 grade designation ) 580 mm internal dia conforming to IS 12592, total weight of cover and frame to be not less than 182 kgs fixed in C .C ( 1:2:4 ) including centering shuttering and complete (excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) with FPS bricks class designation 50. |
| 80 | Providing MS foot rests including fixing in man holes with 20 x 20 x 10 cm Cement concrete blocks ( 1 : 3 : 6 ) ( 1 Cement : 3 Coarse Sand : 6 graded stone aggreate 20 mm nominal size ) as per standard design with 20 x 20 mm square bar |
| 81 | Providing and fixing CP brass long body bib cock of approved quality conforming to IS complete with necessary accessories for 15 mm nominal bore of Jaguar or equivalent tap / cock at all heights and floors |
| 82 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 83 | Providing and fixing constructing road gully chamber 50 x 45 x 60 cm with bricks of class designation 75 in cement mortar 1:4 ( 1 cement : 4 fine sand ) including 500 x 450 mm pre cast RCC horizontal grating with frame complete as per standard design with FPS bricks |
| 84 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete( 1:2:4 ) ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 nominal size ) cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement and making necessary channels for the drain etc., complete for pipes 100 to 250 mm diameter |
| 85 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with insect proof cover (thread type) or cover with suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank (Each 5000 ltr) |
| 86 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P/ H.P.H.D. plastic ball. 20 mm nominal bore, 120 mm long, weighing not less than 198 gms |
| 87 | Providing and fixing CPVC extension nipple for water tank pipe, fittings of approved quality and colour. 20-30 mm nominal bore. Weighing not less than 40 gms. |
| 88 | Supplying, installing, testing and commissioning Electrical Hand Drier twin blower integrated with timer (0-3 minutes) and infrared arrangement. The drier shall be fully automatic. Make : Nova-Tech Model: NT-800, Power: 1700Watts (Size:12x6x12 inches) 230v, 1PH. 50Hz. |
| 89 | Providing and fixing approved quality soap dispenser on wall of 400 ml , all materials labours etc., complete |
| 90 | Supplying, installing, testing 15mm CP health faucet of approved make with necessary CP flexible hose 750mm long nozzle,CP wall flange comptal,model no. 563 |
| 91 | Supplying and filling up the sunken floor with broken light weight cinder as directed by engineer-in-charge. |
| 92 | Providing and laying water proofing treatment in sunken portion ofWCs, bathroom etc., by applying cement slurry mixed with waterproofing cement compound consisting of applying : a) First layer ofslurry of cement @ 0.488 kg/sqm mixed with water proofing cementcompound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry withpolymer mixed slurry. |
| 93 | Providing and fixing Auto Closing Concealed Urinal Flush Valve, of approved quality and colour. ( Jaguar PRODUCT CODE: PRS-CHR-073 or equivalent) as per direction of engineer-in-charge. |
| 94 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of ize(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening“for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. |
| 95 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). and of design approved by Engineer - in - charge at all heights and levels. |
| 96 | Providing and applying of 4mm Thick EPU Flooring: Surface preparation of the substrate by mechanical grinding. Providing and applying one coat of epoxy primer Screed and allow it to dry. Providing and applying 2mm thick Epoxy screed and allow it to dry. Providing and applying 2mm thick top coat of PU flooring including 50x50 mm coving on wall and finishing etc. complete. Consumption & specification will be as per the manufacturere TDS's of Make Sika,MYK Armet, Foscroc, STP, Ardex Endura or equivalent. |
| 97 | Providing and laying vitrified floor tiles of size 600 x 600 mm of thickness not less than 10 mm of M/s. Johnson (Marbonite ) or equivalent in light colours and shades laid on 20 mm thick CM ( 1:3 ) ( 1 cement : 3 coarse sand ) and curing and filling the joints with filler to match with colour of tiles complete as per the directions of the Engineer-in-charge at all levels and floors. |
| 98 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut granite for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 99 | Designing, fabricating, testing,installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc.including:a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5/MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 100 | Supply & Installation of 1.0 mm thick galvanised metal deck sheet with 120 GSM coating mass (Width = 960 mm, Depth = 45 mm, Pitch = 160 mm) including installation with self-drilling & tapping zinc coated fasteners of 12 x 35 mm. Material Properties: High tensile structural grade steel. Coating Standard IS:277:1992. Yield Strength : 550 MPA Premier Coating : 10 - 25 Microns Available Finish : Cold Rolled (CR) |
| 101 | ELECTRICAL WORKS |
| 102 | MCB DBs : Supply, instalation, testing & commissioning of following sizes of 415V, VTPN MCB DBs with metallic door (surface mount / flush mount). The DBs shall be mounted on the wall and shall include necessary mounting hardware, etc. The DBs must have 300 mA earth leakage protection in the incomer circuit. |
| 103 | 8 way DB with 1 no 63A, 4 pole, Isolator as incomer, 3 no's 32/20/16A TP MCB and 15 no's 16A/10A SP MCBs as outgoing.Further detailed breakup of the following work-a) Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) b) Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A, 4 pole, Isolator as incomer(RCCB)c) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required 32/20/16A TP MCB(Out going).d) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required 16A/10A SP MCB(Out going)Note - \\"Inside the DB (Distribution Board), there can be complete single-phase MCBs, three-phase MCBs, or a combination of single and three-phase, according to the site requirements. |
| 104 | Industrial Plug & Sockets: Supply, installation, testing and commissioning of following ratings of Industrial plug and socket controlled by MCB, housed in manufactured sheet metal enclosure. |
| 105 | 30A 5 pin plug and socket with 16A TP MCB.Further detailed breakup of the following work-30A 5 pin plug and socket with 16/20/30A TPN MCB; Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 16/20/30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 106 | 16A SP socket with 16A SP MCB.Further detailed breakup of the following work-16/20A 3 Pin plug and socket with 16/20A SPN MCB; Supplying and fixing 16/20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 16/20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 107 | Socket outlets:Supply, fixing, testing & commisioning of following modular type switch, socket fixed to modular box as mentioned below, with all necessary accessries like modular switch plate etc. |
| 108 | 16 A switch controlled by a 16 A universal shuttered socket.Further detailed breakup of the following work-Supplying and fixing of 16A modular switch and shuttered socket on the modular plate and switch box, including all necessary connections, complete as required. |
| 109 | 6 A switch controlled by a 6 A universal shuttered socket.Further detailed breakup of the following work-Supplying and fixing of 6A modular switch and shuttered socket on the modular plate and switch box, including all necessary connections, complete as required. |
| 110 | RJ-45 socket (suitable for CAT-6) for modular table (without box).Further detailed breakup of the following work-Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 111 | RJ-11 Socket. for modular table (without box).Further detailed breakup of the following work-Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 112 | 10A switch controlling a 10A universal shuttered socket for modular table (without box)Further detailed breakup of the following work-Supplying and fixing of 10A modular switch and 10A Universal shuttered socket on the modular plate including all necessary connections, complete as required. |
| 113 | Circuit wiring:Supply, wiring, testing & commissioning of 650/1100V, FRLS PVC insulated, flexible copper wires for phase, nuetral & earth, drawn in PVC pipe/ Casing-N-Caping. Standard wiring colour code to be used. (wire and pipe/ casing-N-capping are seperately itemised and quantified). |
| 114 | 2mm thk. 1 inch pipe.Further detailed breakup of the following work-Supplying and fixing of 2mm thk. 1 inch pipe size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 115 | 2mm thk. 3/4 inch pipeFurther detailed breakup of the following work-Supplying and fixing of 2mm thk. 3/4 inch pipe size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 116 | 2 inch pvc casing-caping.Further detailed breakup of the following work-Supply, fixing, and commissioning PVC casing and capping of size 2 inch on surface/wall including supply of base channel, snap-on cover (capping), and necessary accessories like elbows, tees, couplers, and end caps of the same make.Rate includes fixing with suitable screws, and all required hardware, ensuring a smooth and neat installation, as per instruction of the Engineer-in-charge. |
| 117 | 1.5 inch pvc casing-caping.Further detailed breakup of the following work-Supply, fixing, and commissioning PVC casing and capping of size 1.5 inch on surface/wall including supply of base channel, snap-on cover (capping), and necessary accessories like elbows, tees, couplers, and end caps of the same make.Rate includes fixing with suitable screws, and all required hardware, ensuring a smooth and neat installation, as per instruction of the Engineer-in-charge. |
| 118 | 1 inch pvc casing-caping.Further detailed breakup of the following work-Supply, fixing, and commissioning PVC casing and capping of size 1 inch on surface/wall including supply of base channel, snap-on cover (capping), and necessary accessories like elbows, tees, couplers, and end caps of the same make.Rate includes fixing with suitable screws, and all required hardware, ensuring a smooth and neat installation, as per instruction of the Engineer-in-charge. |
| 119 | 3/4 inch pvc casing-caping.Further detailed breakup of the following work-Supply, fixing, and commissioning PVC casing and capping of size 3/4 inch on surface/wall including supply of base channel, snap-on cover (capping), and necessary accessories like elbows, tees, couplers, and end caps of the same make.Rate includes fixing with suitable screws, and all required hardware, ensuring a smooth and neat installation, as per instruction of the Engineer-in-charge. |
| 120 | 10 sqmm wire.Further detailed breakup of the following work-Supplying and drawing of 10 sq. mm FRLS/HFFR PVC insulated copper conductor, single-core cable, through existing PVC conduit (surface/recessed/concealed) or above false ceiling, including necessary accessories, handling, and installation, complete as required. |
| 121 | 6 sqmm wire.Further detailed breakup of the following work-Supplying and drawing of 6 sq. mm FRLS/HFFR PVC insulated copper conductor, single-core cable, through existing PVC conduit (surface/recessed/concealed) or above false ceiling, including necessary accessories, handling, and installation, complete as required. |
| 122 | 4 sqmm wireFurther detailed breakup of the following work-Supplying and drawing of 4 sq. mm FRLS/HFFR PVC insulated copper conductor, single-core cable, through existing PVC conduit (surface/recessed/concealed) or above false ceiling, including necessary accessories, handling, and installation, complete as required. |
| 123 | 2.5 sqmm wire.Further detailed breakup of the following work-Supplying and drawing of 2.5 sq. mm FRLS/HFFR PVC insulated copper conductor, single-core cable, through existing PVC conduit (surface/recessed/concealed) or above false ceiling, including necessary accessories, handling, and installation, complete as required. |
| 124 | 1.5 sqmm wire.Further detailed breakup of the following work-Supplying and drawing of 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor, single-core cable, through existing PVC conduit (surface/recessed/concealed) or above false ceiling, including necessary accessories, handling, and installation, complete as required. |
| 125 | 2 pair 0.5 mm ATC telephone cable.Further detailed breakup of the following work-Supplying and drawing of 2 pair, 0.5 mm dia ATC telephone cable with FRLS/HFFR PVC insulated annealed copper conductors, unarmoured, through existing surface/recessed/concealed PVC conduit or above false ceiling, including all necessary accessories, handling, and installation, complete as required. |
| 126 | 5 pair 0.5 mm ATC telephone cable.Further detailed breakup of the following work-Supplying and drawing of 5 pair, 0.5 mm dia ATC telephone cable with FRLS/HFFR PVC insulated annealed copper conductors, unarmoured, through existing surface/recessed/concealed PVC conduit or above false ceiling, including all necessary accessories, handling, and installation, complete as required. |
| 127 | 20 pair 0.5 mm ATC telephone cable.Further detailed breakup of the following work-Supplying and drawing of 20 pair, 0.5 mm dia ATC telephone cable with FRLS/HFFR PVC insulated annealed copper conductors, unarmoured, through existing surface/recessed/concealed PVC conduit or above false ceiling, including all necessary accessories, handling, and installation, complete as required. |
| 128 | Ethernet UTP CAT-6 cable (Make: AMP, Crone, D-link, Avaya)Further detailed breakup of the following work-Supplying, drawing, Installation, Testing and commissioning of Ethernet UTP CAT-6 cable in existing PVC conduit on surface/ recessed/concealed Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. |
| 129 | Supply, Installation, testing and commissioning of DLP PVC Trunking 80 mm x 35 mm with central partition along with the cover, end caps and accessories for the junctions as per site condition. Installation has to carried out along the wall (Make: Legrand or equivalent) (Vendor may carry out site inspection before quoting) |
| 130 | Supply, Installation, testing and commissioning of 10A switch controlling a 10A universal shuttered socket in the DLP PVC trunking.Further detailed breakup of the following work-Supply, installation, testing, and commissioning of 10A modular switch controlling a 10A universal shuttered modular socket, mounted in DLP PVC trunking, including all necessary hardware, accessories, connections, and fixing, complete as required. |
| 131 | Supply, Installation, testing and commissioning of RJ-11 Socket in the DLP PVC trunking.Further detailed breakup of the following work-Supply, installation, testing, and commissioning of RJ moduler socket, mounted in DLP PVC trunking, including all necessary hardware, accessories, connections, and fixing, complete as required. |
| 132 | Supply, Installation, testing and commissioning of RJ-45 Socket (suitable for CAT-6) in the DLP PVC trunking.Further detailed breakup of the following work-Supply, installation, testing, and commissioning of RJ45 modular socket (CAT 6 compatible), mounted in DLP PVC trunking, including all necessary hardware, accessories, terminations, connections, and fixing, complete as required. |
| 133 | Telephone Tag Blocks: Supply and fixing of 10 pair size KRONE Make Telephone Tag Block with enclosure. The scope of work shall also include terminating the Telephone cables to the Tag Block as required.Further detailed breakup of the following work-Supply and fixing of 10-pair telephone tag block (Krone make or equivalent) with suitable enclosure, including termination of telephone cables, complete with all necessary hardware, accessories, connections, and fixing, as required. |
| 134 | Point Wiring :Supply, wiring, testing & commissioning of point wiring using 1100V FRLS PVC insulated, 1.0 sq. mm flexible copper wires for phase, neutral and earth, drawn in concealed 2mm thk. PVC conduit pipe. The scope shall also include accessories such as 3 plate ceiling rose, 6A modular switch, modular switch plate with box, etc. Standard wiring colour code to be used. Primary Point wiring shall be using one control switch for one light. Every switch box shall have one 6A modular universal shuttered socket controlled by a 6A switch. |
| 135 | Primary Point wiring for light fittings/ exhaust fan.Further detailed breakup of the following work-Providing primary point wiring for light fittings and exhaust fans, including supply and laying of required wiring in existing surface/recessed/concealed PVC conduit, along with all necessary hardware, accessories, terminations, connections, and fixing, complete as required. |
| 136 | Secondary point wiring for Light fitting/ exhaust fan. (Secondary point shall have a common switch with primary point.)Further detailed breakup of the following work-Providing Secondary point wiring for light fittings and exhaust fans, including supply and laying of required wiring in existing surface/recessed/concealed PVC conduit, along with all necessary hardware, accessories, terminations, connections, and fixing, complete as required. |
| 137 | Point wiring for celling fans including a 2 module electronic stepped speed regulator.Further detailed breakup of the following work-Providing point wiring for ceiling fans, including supply and installation of 2-module electronic stepped speed regulator, along with supply and laying of required wiring in existing surface/recessed/concealed PVC conduit, complete with all necessary hardware, accessories, terminations, connections, and fixing, as required. |
| 138 | Cable tray: Supply, fixing and commissioning of the following sizes of hot dipped GI ladder type cable trays with all required accessories like couplers, tees, bends, reducers, suitable angle brackets, anchor fasteners etc. |
| 139 | 300mm wide X 75mm height X 2mm thick.Further detailed breakup of the following work-Supplying and installation of hot-dip galvanized ladder-type cable tray of size 300 mm (W) × 75 mm (H) × 2 mm thickness, with powder-coated finish, in suitable sections, including joining with connectors, suspension from ceiling using MS/GI suspenders (2 Nos. per section), complete with bolts, nuts, fasteners, painting of suspenders, and all necessary accessories, complete as required. |
| 140 | M.S. supports for the cable trays Further detailed breakup of the following work-Providing and fixing MS supports for ladder-type cable trays, including fabrication, cutting, drilling, welding, and installation, complete with all necessary fasteners, hardware, and painting, as required. |
| 141 | Light fixtures :Supply, fixing, testing & commissioning of the following Luminaries with all accessories like lamp holders, electronic control gear and lamps. The fittings shall be fixed on ceiling/ suspended fom the ceiling using MS Chain and anchor fateners and connected using 3 core flexible cable, etc. |
| 142 | Supply, fixing, testing & commissioning of LED type high bay light fitting of 120W, Color Temp: 6000K+/-500K, CRI>=70%, THD<=10%, beam angle >=120 deg with all required electronic control gear. The fixture shall be supported by a test certificate from a reputed lab such as CPRI/ CE/UL/ ULC/ FCC etc. Light fittings to be approved by BHEL engineer incharge before supply. The fixture shall have mounting arrangement and should be mounted at 10m height using suitable clamping arrangement. (Vendor has to arrange suitable platforms to work at height of 10 mts, and vendor shall quote accordingly) |
| 143 | Supply, fixing, testing & commissioning of 20 Watt, 1200mm LED Tube light fitting with all required control gear. The fixture shall be supported by a test certificate from a reputed lab such as CPRI/ CE/UL/ ULC/ FCC etc. Light fittings to be approved by BHEL engineer incharge before supply.Further detailed breakup of the following work- Supplying and fixing of batten-type LED light fitting, 20 W, 1200 mm length, with polycarbonate housing and CCT 6500 K, including all necessary accessories, connections, and fixing, complete as required. |
| 144 | Supply, fixing, testing & commissioning of Bajaj 36 W, 4 x 1 luminaire, model- BZSSLL 36W or BZRSLL 36W GZ1of white light type or equivalent fitting suitable for recessed mounting/ surface mounting .Light fittings to be approved by BHEL engineer incharge before supply.Further detailed breakup of the following work-Supply, installation, testing, and commissioning of LED light fitting, 36/40 W, size 4 ft × 1 ft, Bajaj make or equivalent, with CCT 6500 K, suitable for recessed/surface mounting or fixing on false ceiling, including all mounting accessories, internal wiring, connectors, and complete installation, as required. |
| 145 | Fans: |
| 146 | Supply, fixing, testing and commissioning of wall mounting fan, 400 mm sweep, as per approved make.Further detailed breakup of the following work-400mm BLDC motor Wall Mount Fan. Voltage - 230 volt, 50Hz. Power - Maximum 45 watt. Warranty - 1 Year (White colour), BEE( Bureau of energy efficiency) 5 Star rating. Speed - 1300 to 1500 Rpm. Power Source -Corded Electric, Mounting Type Wall Mounted. |
| 147 | Supply, fixing, testing & commissioning of 380 mm sweep, 1400 rpm, heavy duty exhaust fan with all necessary accessories. The scope shall include fixing of Exhaust fan using necessary hardwares.The rate shall include connecting cable.Further detailed breakup of the following work-Propeller Type AC Ventilating Fans- Exhaust Fan(v2) as per IS 2312. Electric Exhaust Fan 380mm, BIS marked, ISI marked, Voltage - 230v 50 Hz a.c single phase ,Warranty 01 yrs,No of blade 4, No of pole 4, Capacitor type, no speed regulator. |
| 148 | Supply, fixing, testing & commissioning of 5 Star rated Energy efficient Ceiling fans of 3 blade, 1200 mm sweep without fan regulator. The rate shall include connecting cable.Further detailed breakup of the following work-5-star BLDC ceiling fans typically consume 28W–35W, 1200mm sweeps, 340-380 RPM, and 220-237 CMM air delivery. Standard specs include 100% copper motors, RF remotes with timer/speed modes, and broad voltage range operation (e.g., 140V–285V) |
| 149 | Fire Alarm System Supply, installation, testing and commissioning of the following . |
| 150 | Microprocessor based fire alarm panel: Supply, installation, testing & commisioning of 8 Zone, Fire control panel in sheet steel enclosure, Input - 230V A/C and Output - 24V DC, with all necessary indications like Main, System ON, Standby, Low Battery and individual fire and fault with audio - visual indication, test and isolation facility, consisting of power supply module with built in charger without battery, relay output, fully assembled and wired. suitable quantity of Lead acid sealed maintenance free battery 12v, 7Ah including connecting leads and battery charger shall be included in the package.(Make: Cherytech / Alert / Globe/ Kafex/ Minimax.)Further detailed breakup of the following work-Supply, installation, testing, and commissioning of 8-zone conventional fire alarm control panel, complete with inbuilt SMPS and automatic battery charger, having individual LED indications for FIRE and FAULT for each zone, and system indications for AC mains ON, system ON, standby/battery low, charger ON, and earth fault. The panel shall be housed in a rugged CRCA sheet steel enclosure (18 gauge, 1.2–1.5 mm thick) with powder-coated finish, suitable for wall mounting, and shall be provided with both trickle and fast battery charging facility. Make: Cherytech / Alert / Globe / Kafex / Minimax / Ravel or equivalent, complete as required. |
| 151 | Photoelectric smoke cum heat detectors: Supply, installation, testing & commisioning of Photo electric smoke cum Heat detector (multi sensor) detectors with base.Further detailed breakup of the following work-Supply, installation, testing, and commissioning of multi-sensor detector (photoelectric smoke cum heat type) with base, suitable for conventional/addressable fire alarm system, operating on optical smoke detection combined with thermal sensing (fixed temperature/rate-of-rise), housed in high-impact fire-retardant ABS/PC enclosure, including all necessary mounting accessories, wiring, terminations, and integration with fire alarm control panel, complete as required. Make: Honeywell / Siemens / Ravel / Agni / System Sensor or equivalent. |
| 152 | Heat Detectors.Further detailed breakup of the following work-Supply, installation, testing, and commissioning of heat detector (rate-of-rise cum fixed temperature type) with dual thermistor, operating at 54°C/57°C, suitable for fire alarm system, housed in high-impact fire-retardant ABS/PC enclosure, ceiling-mounted with compatible base, including all necessary mounting accessories, wiring, terminations, connections, and integration with fire alarm panel, complete as required. Make: Honeywell / Siemens / Ravel / Agni / System Sensor or equivalent. |
| 153 | Manual call points : Supply, installation, testing & commisioning of manual call point break glass unit including hammer and chain.Further detailed breakup of the following work-Supply, installation, testing, and commissioning of manual call point (break-glass type), with resettable/replaceable glass, LED indication for alarm status, complete with hammer and chain, suitable for wall mounting with back box, housed in fire-retardant ABS/PC enclosure, including all necessary accessories, wiring, terminations, connections, and integration with fire alarm system, complete as required. |
| 154 | Electronic hooter with strobe: Supply, installation testing & commissioning of dual tone electronic hooter with strobe.Further detailed breakup of the following work-Supply, installation, testing, and commissioning of dual-tone electronic hooter with high-intensity LED strobe light, suitable for fire alarm system, housed in high-impact fire-retardant ABS/PC enclosure, suitable for wall/ceiling mounting with appropriate base, including all necessary mounting accessories, wiring, terminations, connections, and integration with fire alarm control panel, complete as required. Make: Honeywell / Siemens / Ravel / Agni / System Sensor or equivalent. |
| 155 | Supply, laying, testing and commissioning of 2 X 1.5 sq. mm 1.1 KV grade PVC insulated copper conductor flexible cable.Further detailed breakup of the following work-Supply, laying, testing, and commissioning of 2C × 1.5 sq. mm, 1.1 kV grade flexible cable with annealed stranded copper conductors and PVC insulation (FR/FRLS/HFFR as required), laid through existing surface/recessed/concealed conduit or on cable tray/above false ceiling, including all necessary accessories, saddles, clamps, terminations, ferruling, dressing, and connections, complete as required. |
| 156 | Cabling for fire alarm: Supply, laying, testing & commissioning of following XLPE insulated, Copper conductor, armoured cables. The cable shall be laid underground at 750 mm depth, covered by brick and sand cushioning/ in GI pipe/ clamped on wall using clamps as per site condition. All excess soil shall be removed out of the factory. Necessary cable route markers shall be provided. The cost of G.I pipe is covered seperately. |
| 157 | 4C 1.5 sqmm cable laid underground. |
| 158 | 4C 1.5 sq. mm. cable clamped on wall/ laid in indoor trench. |
| 159 | Dismantling Works in Building 13 - Following items to be dismantalled and shifted to another location within the factory premises (within 300 mtrs) - Vendors are advised to inspect the site befor quoting |
| 160 | Roof Top Solar System: It has 2 nos 50KW inverters, 1 no 20 KW inverter, and approx.500Nos PV Modules along with associated wiring and metallic structures.Further detailed breakup of the following work-Dismantling, careful handling, and shifting of existing rooftop solar power system from Building No. 13 to another location within the factory premises (within 300 meters), comprising 2 Nos. 50 kW inverters, 1 No. 20 kW inverter, approximately 500 Nos. PV modules, along with all associated wiring, cables, junction boxes, and metallic support structures, including necessary disconnection, labeling, packing, loading, unloading, and re-stacking, complete as required. |
| 161 | Goods / Cage Lift - G+1 Floor, 2000 / 2500Kg Capacity along with all accessories and controls.Further detailed breakup of the following work-Dismantling, careful handling, and shifting of Goods/Cage Lift (G+1 floor) of 2000/2500 kg capacity from Building No. 13 to another location within the factory premises (within 300 meters), including all associated accessories, controls, panels, wiring, and mechanical components, complete with necessary disconnection, dismantling, packing, loading, transportation, unloading, and re-stacking, as required. |
| 162 | Electrical LT Panels |
| 163 | LT Panel with 1 No 630A SDFU as Incomer and outgoing MCCBs compartments 400A - 2Nos, 250A - 3Nos, 200A - 4Nos, 125A - 12Nos, 63A - 12 Nos along with removal of cable terminations in each incoming and outgoing compartments |
| 164 | LT Panel with 1 No 400A SDFU as Incomer and outgoing MCCBs compartments 63A - 10 Nos along with removal of cable terminations in each incoming and outgoing compartments |
| 165 | LT Panel with 1 No 400A SDFU as Incomer and outgoing MCCBs compartments 63A - 5 Nos along with removal of cable terminations in each incoming and outgoing compartments |
| 166 | TPN MCB Distribution Boards -20 nos.Further detailed breakup of the following work-Dismantling, careful handling, and shifting of TPN MCB distribution boards (20 Nos.) from Building No. 13 to another location within the factory premises (within 300 meters), including all associated components, wiring, and accessories, complete with necessary disconnection, dismantling, labeling, packing, loading, transportation, unloading, and re-stacking, as required. |
| 167 | TPN AC BBT System and DC BBT System approx. total 100MtrFurther detailed breakup of the following work-Dismantling, careful handling, and shifting of TPN AC BBT System and DC BBT System (100 Mtrs) from Building No. 13 to another location within the factory premises (within 300 meters), including all associated components, wiring, and accessories, complete with necessary disconnection, dismantling, labeling, packing, loading, transportation, unloading, and re-stacking, as required. |
| 168 | 200A/250A/400A MCCB with enclosures - 4 nos.Further detailed breakup of the following work-Dismantling, careful handling, and shifting of 200A/250A/400A MCCB (04 Nos.) from Building No. 13 to another location within the factory premises (within 300 meters), including all associated components, wiring, and accessories, complete with necessary disconnection, dismantling, labeling, packing, loading, transportation, unloading, and re-stacking, as required. |
| 169 | Ceiling light fittings approximately 200 nos.Further detailed breakup of the following work-Dismantling, careful handling, and shifting of Ceiling light fittings(200 Nos.) from Building No. 13 to another location within the factory premises (within 300 meters), including all associated components, wiring, and accessories, complete with necessary disconnection, dismantling, labeling, packing, loading, transportation, unloading, and re-stacking, as required. |
| 170 | Cables - To be cutted into 1 mtr pieces before disposal |
| 171 | 3.5 C * 185 Sq.mm Al cable - 100 mtrs approxFurther detailed breakup of the following work-Dismantling and disposal of existing 3.5C × 185 sq. mm aluminium cable, approximately 100 meters in length, including cutting into 1-meter pieces, handling, loading, and safe disposal as per site requirements, complete as required. |
| 172 | 3.5 C * 70/50/30/25 Sq.mm Al cable - 400 mtrs approx.Further detailed breakup of the following work-Dismantling and disposal of existing 3.5 core aluminium cables of sizes 70/50/30/25 sq. mm, approximately 400 meters in total length, including cutting into 1-meter pieces, handling, loading, and safe disposal as per site requirements, complete as required. |
| 173 | Misc. minor items wires, conduit pipes, cables power points etc.Further detailed breakup of the following work-Provision for execution of miscellaneous electrical works including panel modifications, removal of existing conduit pipes, alteration/extension of wiring and cables, removal of power outlets, dismantling and refixing of electrical equipment/items, and other associated works as per site requirements and instructions of the Engineer-in-Charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |