| 1 | M&L Air termination single pointed aluminium rod 12 mm dia and 300 mm long all as specified and as directed by Engr-in-charge. |
| 2 | M & L Test point terminal block made of gun metal or phosphorus bronze size incliding 3 Nos 8 mm dia 25 mm long hex. Head screw all as specified and directed by Engr-in-charge. |
| 3 | M & L aluminium strip 25 x 3.15 mm with saddles amd fixing secres etc for roof conductors and down conductors all as specified and directed by Engr-in-charge |
| 4 | M & L Galvanised iron stip 32 x 6 mm burried in ground all as specified and directed by Engr-in-charge |
| 5 | S&F in repair of GI tubing 15 mm bore 'medium grade' including all necessaory fittings i.e. socket, elbow etc.laid in trenches complete all as specified and directed. |
| 6 | S&F Stop valve of 15mm dia complete all as specified and directed. |
| 7 | Supply and fix Bib tap 15 mm bore size of cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed |
| 8 | M&L for Cutting the existing GI pipe upto 80mm for tapping of 15 mm branch including required fittings complete all as specified and as directed. |
| 9 | S&F epoxy insulators suitable of aluminium strip of 25x3.15 mm size with nut bolts/ screws for fixing of copper/ aluminium / GI strips on stone / PCC block walls etc complete all as specified and directed. |
| 10 | S&F in repair of earthing pit cover 50 mm thick precast slab of RCC 1:2:4 type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm incl 6 mm dia bar handle complete all as specified and directed. |
| 11 | M&L for fixing earth indicators made out of 3 mm thick MS sheet of size 200 mm x 300 mm duly fixed in MS angle iron 25 mm x 25mm x 3mm of 600 mm long fixed to ground by means and including necessary cement concrete foundation and painting with one coat of synthetic enamel paint over a coat of red oxide primer complete for writing earth reading and connected plant/ panel etc. and excavation and earth work complete all as specified and directed. |
| 12 | Material and labour for supply, installation, testing and commissioning of GI pipe electrode earthing maintenance free earthing based on 6 mtr long GI pipe 76 mm dia(ID) medium grade, GI strip 32x6 mm (Strip in pipe type electrode) and GI pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KGS approx of BFC shall be filled around the GI pipe electrode. Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed.Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore. Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out monthly by MES authority.GI strip must be connected with GI pipe electrode and other joints through GI nut bolt complete all as specified and directed. |
| 13 | M & L GI tubing of 40 mm bore light grade with all fitting fixed to wall/ceiling or laid on floor all as specifed and directed. |
| 14 | M & L for providing cement concrete in roof of type B1 1:2:4 20 mm graded aggregate in roof kerbs or mug stops, rounded or chamfered on deges all specified |
| 15 | Supply and laying in trenches or fixing to wall/pole or passing through pipe XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 150 Sqmm 3.5 core.Make of cable ICL/ICC/Gloster/Havells/ Paragon/ Grandlay/Kalinga. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification) |
| 16 | Supply and fixing 80 mm dia DWC (Double Wall Corrugated) pipe (6 mtr length) in trenches for laying of under ground cable, HSN Code : 3917 and product code A0214100NEC012D any approved make etc complete all as specified and as directed |
| 17 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft/loose soil etc complete all as specified and directed by Engr-in-Charge. |
| 18 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soil complete all as specified and directed by Engr-in-Charge. |
| 19 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft disintegrated rock complete all as specified and directed by Engr-in-Charge. |
| 20 | Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed by Engr-in-Charge. |
| 21 | Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point complete all as specified and directed by Engr-in-Charge. |
| 22 | Supply and fix GI Pipe Light grade with all connected accessories of sizes 80 mm dia complete all as specified and directed by Engr-in-Charge. |
| 23 | Cutting of existing road not exc 1.5 mtr in depth and not exceeding 1.5 mtr wide including black top, sub base and WBM, well ramming in layers with watering after laying of RCC /GI pipe under road making good in all respect to match with the existing surface all as directed by E-in-charge. |
| 24 | Supply install, test and commissioning of Powder coated LT panel cubical out door type free standing type compartmentalized in construction fabricated from CPRI approved manufacturer specified in particular specification and made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars of 300 A, incomer MCCB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The cubicle shall have free standing bottom frame/stand of height 600mm & dimension as required for panel & shall be made out of equal angle iron of size 50mm x 50mm x 6mm. A detachable predrilled gland plate of thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. Copper extension link shall be provided at incomer & outgoing end of MCCB of rating 100 Amps & above. The panel shall be powder coated of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire, including taking down of old unsv panel after disconnecting Existing cable & Reconnecting the cables to new panels including providing cable glands, lugs, nut bolts etc, grouting bolts, the panel shall comprise of following and including demolition of existing PCC foundation, complete all as specified & directed by Engineer in Charge. |
| 25 | a) Aluminium bus bar 450 Amps for 3 phase and 225 Amps for Neutralb) MCCB FP 250 Amps 415 Volt 36 KA - 1 Nosc) MCCB FP 160 Amps 415 Volt 25 KA - 2 Nosd) MCCB FP 125 Amps 415 Volt 25 KA - 2 Nose) MCB SPN 40 Amps, 10 KA 415 Volts- 1 Nosf) Fully automitic On load change over switch 4 Pole 250 Amps - 01No g) RYB Indicators - 1 Set h) Street Light Timer Circuit with Following Acessories:- (i) ML 3, Contactor Coil Voltage 440 Volts - 1 No (ii) Astro Timer - 1 No (iii) Auto Manual Selector Switch - 1 No (iv) Cnnector TPN 63 Amps - 4 Nos (v) MCB TPN 63 Amps - 1 NoNote - Note :-(i) The lay out drawing of the panel shall be got approved by the contractor before panel fabrication.(ii) PCC Foundation required for installation of Panel Shall be Measured and Paid Seperately under respective item. |
| 26 | Excavation in post holes or (Similar holes) each n.exc 0.5 cum, getting out, returning filling in and ramming each or broken rubber mixed with each around in layers, n.exc 25 cm watering and removing surplus soil to a distance n.exc 50 m and making food surfaces in Hard/Dense soil. |
| 27 | M&L for PCC 1:3:6 type C2 (40 mm graded Stone aggregate) as in foundation of post holes filling and mass con crete all as specified and directed. |
| 28 | S&F for steel work in tublar traes including special shaped washer etc complete using ERW or induction but welded tubes conforming to IS 1161-1979 grade SI-240 |
| 29 | S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 30 | S&F Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 31 | M&L for two coat of synthetic enemel paint on new steel surfaces over one coat of red oxide primer over 10 cm width of grith including prepration of surface Please Enable Macros to View BoQ information |
| 32 | M&L for two coat of synthetic enemel paint on new steel surfaces over one coat of red oxide primer over 10 cm width of grith including prepration of surface Please Enable Macros to View BoQ information |