|
| 1 | Dismantling of AC Sheet corrugated / semi corrugted sheets in wall cladding or in roof covering complete all as specified and directed. |
| 2 | M&L 6mm thick non-asbestos fibre cement corrugated or semi corrugated sheets as in roofs, walls etc fixed with 'L' type or 'J' type hooks or cranked hook bolts complete all as specified and directed. |
| 3 | Fixing only 6mm thick Asbestos fibre cement corrugated or semi corrugated sheets as in roofs, walls etc. fixed with 'L' type or 'J' type hooks or cranked hook bolts complete all as specified and directed. Note : AC Sheets retrieved from dismantling shall be used. |
| 4 | S&F 6mm thick non-asbestos fibre cement two piece serrated ridges for corrugated or semi-corrugated sheet fixed with 'L' hooks or 'J' hooks or cranked hook bolts complete all as specified and directed. |
| 5 | Dismantling structural steel work including doors, gates but excluding framed trusses etc complete all as specified and directed. |
| 6 | M&L for structural steel work with rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins, MS tubes where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to Fe-290 (Gde E-165) quality 'A' complete all as specified and directed. |
| 7 | Dismantling plain or corrugated steel sheeting any gauge thickness including nanital or similar pattern roof covering complete all as specified and directed. |
| 8 | M&L pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 9 | M&L Prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 10 | M&L for reinforced cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in chajjas, landing, balconies, canopies, desk slab and in shelves etc complete all as specified and directed. |
| 11 | Use and waste for form work to chhajjas, kitchen slabs or shelves racks stabs, lintel or similar work for fair finished surfaces, horizonal etc complete all as specified and directed. |
| 12 | S/F mild steel TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends land binding with mild steel wire (annealed) not less than 0.9mm dia, or securing with clips complete all as specified and directed. |
| 13 | Dismantling, floor hearth or wall tiling inclduing cement mortar bedding and removing rubbish off the premises complete all as specified and directed. |
| 14 | S&F joint free non skid Ceramic tiles, 7 to 8mm thick (square/rectangular), area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 15 | M&L joint free vitrified ceramic tiles of 7 to 8mm thick area of each tile exceeding 0.18 and not exc 0.36 Sqm in floor, shelves etc set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed. |
| 16 | Discription same all as per item No 15 here-in-before but on wall for skirting etc over a 10mm thick backing layer of CM 1:4 |
| 17 | M&L for Glazed ceramic coloured tiles 450 mm x 300 mm x 6 mm to 7 mm thick in skirting, dados, risers to steps etc and jointed in neat cement slurry and pointed in coloured cement to match tiles over and including 10mm thick rendering or backing layer in cement mortar 1:4 complete all as specified and directed. |
| 18 | M&L for first or premium quality heavy duty pavement tiles 300mm x 300mm x 10mm / 400mm x 400mm x 10mm thick coloured for floor/pavement etc & jointed in neat cement slurry and pointed with white cement fixed with colour pigment to match colour of tiles including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 19 | M&L for Granite 15-18mm thick (of any type) work (table rubbed and polilshed) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 20 | M&L for Granite 15-18mm thick (of any type) work (table rubbed and polilshed) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing in wite cment (1:2) using marble dust with admixture of pigment to match with shade of granite over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 21 | M&L Marble work (Green marble) 12 to 15mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including 15mm thick screed bed in CM 1:6 complete including making grooves if the marble provided on the steps complete all as specified and directed. |
| 22 | S&F Steel water tubes, medium grade, ISI marked, galvanised 15mm bore with all fittings, fixed to walls and ceiling or laid in floors including taking down complete all as specified and directed. |
| 23 | S&F Steel water tubes, medium grade, ISI marked, galvanised 20mm bore with all fittings, fixed to walls and ceiling or laid in floors including taking down complete all as specified and directed. |
| 24 | S&F Steel water tubes, medium grade, ISI marked, galvanised 25mm bore with all fittings, fixed to walls and ceiling or laid in floors including taking down complete all as specified and directed. |
| 25 | Supplying and laying 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 including fittings and fixtures of brass or simple type in trenches including taking down of GI pipes complete all as specified and directed. |
| 26 | Refixing old 15mm dia bore steel water tubing and connection with new fitting in new or old position fixed to wall, ceiling or laid in floors including taking down complete all as specified and directed. |
| 27 | Refixing old 20mm dia bore steel water tubing & connection with new fitting in new or old position fixed to wall, ceiling or laid in floors including taking down complete all as specified and directed. |
| 28 | Refixing old 25mm dia bore steel water tubing & connection with new fitting in new or old position fixed to wall, ceiling or laid in floors including taking down complete all as specified and directed. |
| 29 | S&F in repair vitreous china wash hand basin white, flat back of size 550mm x 400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of tap, waste fitting etc complete all as specified and directed. |
| 30 | S&F in repair vitreous china counter top wash basin sunk type, white, oval shape of size 600 x 400 x 185mm fixed on granite including cutting for and pinning in ends in CM 1:3 including 32mm dia chromium plated waste coupling complete all as specified and directed. |
| 31 | S&F in repair pillar taps, cast copper alloy, swan neck type quarter turn, fancy type, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore complete all as specified and directed. |
| 32 | S&F in repair Brass CP central hole basin mixer quarter turn for mixing hot & cold water screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore for WHB complete all as specified and directed. |
| 33 | S&F in repair CP stop valve 15mm bore, fancy type cromimum plated with long shank and cup (concealed type), high pressure crutch or butter fly handle quarter turn screwed both ends screwed for iron pipe or for unions complete all as specified and directed. |
| 34 | S&F in repair CP stop valve/angle valve 15mm bore, fancy type cromimum plated with long shank and cup, high pressure crutch or butter fly handle quarter turn screwed both ends screwed for iron pipe or for unions complete all as specified and directed. |
| 35 | S&F in repair rotational moulded, multilayer HDPE water storage tank (white colour) of 1000 ltrs capacity (Cylindrical vertical with closed top) ISI marked fixed in position on existing places with fittings and refixing of inlet, outlet & overflow pipe etc complete all as specified and directed. |
| 36 | S&F in repair rotational moulded, multilayer HDPE water storage tank of 500 ltrs (white colour) capacity (Cylindrical vertical with closed top) ISI marked fixed in position on existing places complete and refixing of inlet, outlet & overflow pipe etc complete all as specified and directed. |
| 37 | S&F in repair PVC waste pipe 32mm dia, 60 cm long for WHB/Urinal with cup, complete all as specified and directed. |
| 38 | S&F in repair PVC waste pipe 40mm dia, 60 cm long for Sink with cup, complete all as specified and directed. |
| 39 | S&F in repair PVC connection 15mm size with P.T.M.T nuts of length 450mm complete all as specified and directed. |
| 40 | S&F float Valves 20mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed. |
| 41 | S&F in repair 5.5 mm thick bevelled edge looking mirror of selected quality glass, mounted on wall with stainless steel struts and screw complete all as specified and directed. |
| 42 | S&F in repair PVC valve, symphonic action type, flushing cistern 10 ltrs capacity low level white with inlet, ball valve, float and handle including brocket complete all as specified and directed. |
| 43 | S&F in repair for grating doom 100 mm dia of stainless steel complete all as specified and directed. |
| 44 | S&F in repair bib taps with wall flange 15mm bore, fancy type, quarter/half turn, brass chromium plated, long body with capstan head and cup screwed down, screwed for iron pipe or for brass ferrule including accessories complete all as specified and directed. |
| 45 | S&F in repair Bib tap standard of PTMT 15mm bore any colour high pressure screwed for iron pipe and fixed complete all as specified and directed. |
| 46 | Demolition and breaking up drain waste pipes (SGSW, AC or RCC, CI ) of internal dia 75mm / 110 mm, set in cement mortar complete all as specified and directed. |
| 47 | S&F PVC (SWR) pipes, Single socketed, in any length with rubber ring joints, fixed to walls 110 mm bore complete all as specified and directed. |
| 48 | S&F PVC (SWR) pipes, Single socketed, in any length with rubber ring joints, fixed to walls 75 mm bore complete all as specified and directed. |
| 49 | S&F PVC (SWR) bends any radius, 75 mm with access door complete all as specified and directed. |
| 50 | S&F PVC (SWR) bends any radius, 110 mm with access door complete all as specified and directed. |
| 51 | S&F PVC 75mm bore (SWR) junction single (Single T), equal or unequal 75mm bore complete all as specified and directed. |
| 52 | S&F PVC 110mm bore (SWR) junction single (Single T), equal or unequal 110 mm bore complete all as specified and directed. |
| 53 | M&L for Water Proofing Treatment to sunken floor with polymeric water proofing membrane after cleaning the surface by wire brushes, brooming, removing dust and applying treatment as under complete all as specified and directed :-(a) M&L Plastering 15mm thick in CM 1:4 using 100% coarse sand on roof including WPC 3% by weight of cement.(b) Applying a coat of bitumen primer conforming to IS-3384 - 1965 @ 0.50 lit/Sqm and allow to dry.(c) Applying one coat of hot blown bitumen grade 85/25 as per IS-702-1988 @ 1.20 Kg/Sqm of each coat applied over primer incl cleaning of surfaces .(d) Supply and laying polymeric water proofing membrane of 3mm thick with consists of a centre core 90 micron thickness molecular high density polyethylene film protected on both sides with a high quality polymeric asphaltic mix will be protected on both sides with20 micron HMHDPE film, weight not less than 3.00 Kg/Sqm over area including overlapping as per manufacturers instruction.(e) M&L for for applying a tack coat of hot blown bitumen as per IS 702-1988 applying evenly on top of polymeric water proffing membrance @ 1.20 Kg/sqm. (f) M& L for blending of course dry sand @ 0.75 KG/Sqm |
| 54 | S&F in repair vitreous china wash down water closet of \\"Orissa\\" pattern size 580 x 440 mm white with integral foot rests including removing filled lean concrete from sunken portion and putting of lean concrete after treatment of sunken slab, connection to trap and to flushing pipe etc and making good to floor complete all as specified and directed. |
| 55 | S&F in repair vitreous china wash down water closed pan (Pedestal pattern) with 'P' or 'S' trap white including connection to trap and cistern, flush pipe including white plastic water closet seat cover, closed pattern with flat bottom & cover and aluminium anodised hinging device and making good disturbed surface of floor complete all as specified and directed. |
| 56 | S&F in repair plastic water closet seat cover, white, closed pattern with flat bottom & cover and aluminium anodised hinging device and fixed WC pan complete all as specified and directed. |
| 57 | S&F in repair for flush kit for cistern complete all as specified and directed. |
| 58 | S&F rubber door seal 5mm thick, 32mm wide, with Aluminium strip of size 19mm thick fixed with machine steel screw with washer complete all as specified and directed. |
| 59 | Demolition of brick work built in cement mortar or cement lime mortar complete all as specified and directed. |
| 60 | M&L for brick work with fly ash old size bricks straight or curved on plan exc 6 m mean radius built in cm (1:6) complete all as specified and directed. |
| 61 | Description same all as per item No 60 here-in-before but except brick (brick used obtained from demolition) |
| 62 | M&L for brick work with Sub Class ‘B’ Bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:6) complete all as specified and directed. |
| 63 | M&L for 15mm thick rendering (including taking down) on other than fair faces of brick wall in CM 1:6 finished even and smooth with out using extra cement complete all as specified and directed. |
| 64 | M&L for 15mm thick rendering (including taking down) on fair faces of brick wall or concrete in CM 1:4 finished even and smooth with out using extra cement complete all as specified and directed. |
| 65 | M&L for 5mm thick rendering (including taking down) on fair faces of brick or concrete ceiling surface in CM 1:3 finished even and smooth with out using extra cement complete all as specified and directed. |
| 66 | M&L for preparing of newly plastered wall surface and applying two coats of cement base paint over a coat of cement wash complete all as specified and directed. |
| 67 | M&L for applying 1 to 2mm thick wall care putty (weatherproof or as applicable) on wall or ceiling complete all as specified and directed. |
| 68 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade complete all as specified and directed. |
| 69 | M&L for preparation of newly plastered surfaces of ceiling & applying three coats of white wash complete all as specified and directed. |
| 70 | M&L applying for preparing new plastered decorated surfaces of wall and applying two coat of exterior emulsion paint (Apex/Weather coat) white or tinted as approved complete all as specified and directed. |
| 71 | M&L for preparation of old plastered or unplastered surface of wall including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and applying two coat of white wash on old surface of wall complete all as specified and directed. |
| 72 | M&L for preparation and complete removal of existing treatment from old plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint complete all as specified and directed. |
| 73 | M&L for complete removal of existing finishes of wall including cornices etc and applying one coat of exterior weather proof 100% anti fungal acrylic smooth emulsion with silicon additives that offer anti algae high performance exterior wall finish with 4 years of performance warranty by manufacturer complete all as specified and directed. |
| 74 | M&L for preparation of old plastered or unplastered surface of wall including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and applying two coat of Cement Base Paint white or tinted of approved shade complete all as specified and directed. |
| 75 | Taking down door chowkhat with shutter area not exc 1.5 Sqm each (without taking off shutters from the frame) complete all as specified and directed. |
| 76 | Taking down chowkhats or frames with shutters exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutters from the frame) complete all as specified and directed. |
| 77 | Taking down shutters of wooden or aluminium door any description area exc 1 Sqm and not exc 2 Sqm each complete all as specified and directed. |
| 78 | Refixing wooden or aluminium door shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each in the same opening after taking down, easing and adjusting including refixing builders hardware, glass etc as required & renewal of unserviceable screws complete all as specified and directed. |
| 79 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/window/ Ceosetory windows & other Frames/Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 Gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 Kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/Sqmm, modules of elasticity 900 N/Sqmm and resistance to spread of flame of Class 'A' category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed (M.S hold fast/ lugs or SS dash fasteners shall be paid for separately). Note : For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 80 | Description same all as per item No 79 here-in-before but of Frame size 65mm x 125 mm |
| 81 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/Sqmm, modulus of elasticity 850 N/Sqmm and resistance to spread of flame of Class 'A' category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as specified and directedNote : Stainless Steel butt hinges and necessary S.S screws shall be paid separately. |
| 82 | M&L for PCC 1:3:6 type C-1 using (20mm graded stone aggregate) as in bed blocks for hold fast,Coping errection of posts etc complete all as specified and directed |
| 83 | M&L Mild Steel work as in bands, straps, supports or stays for rain water, ventilating pipes including bolts, if required, hooks (stay) heavy for large gates, hooks and pintle hinges, large hasp and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed |
| 84 | S&F 30mm thick FACTORY MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of Density 650 Kg/Cum manufactured by an ISO-9001-2015 certified Company, Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose (confirming as per IS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 Nos M.S powder coated butt hinges size 100mm x 25mm x 2mm and 32mm long steel screws drilled suitable to pass through both the walls of the MS tube. Other hardwares should be fixed with 19 x 6mm size steel screws etc as per manufacturer's specification & drawings, complete all as specified and directed |
| 85 | S&F for 2nd class hardwood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed |
| 86 | S&F factory made 30 mm thick flush shutter solid core construction with block board core & plywood face panels commercial type on both sides incl 5mm thick teakwood leaping alround complete all as specified and directed |
| 87 | S&F 2nd class hardwood factory made door, 35 mm thick, glazed and skeleton shutters, open rebated and prepated to receive glass gauze etc (with sash bars) edges of framing plain, chamfered or rounded materials and revated sash bars any number, edges of framing plain chemfered or rounded fitted with cut and mitred beads for securing glass in door etc or provided with styles and rails as specified in SSR part 1 section 8, clause 8.20 (a) complete all as specified and directed Please Enable Macros to View BoQ information |
| 88 | S&F 2nd class hardwood factory made door, 35 mm thick, glazed and skeleton shutters, open rebated and prepated to receive glass gauze etc (with sash bars) edges of framing plain, chamfered or rounded materials and revated sash bars any number, edges of framing plain chemfered or rounded fitted with cut and mitred beads for securing glass in door etc or provided with styles and rails as specified in SSR part 1 section 8, clause 8.20 (a) complete all as specified and directed Please Enable Macros to View BoQ information |