| 1 | Demolition of brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 2 | M&L for precast cement concrete block masonry with PCC solid blocks in 1:3:6 type C1 using 20mm graded stone aggregates, exc. 10cm in width and set in CM 1:4 complete all as specified and directed. |
| 3 | Taking down cement plaster on brick or stone walls or concrete surfaces etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 4 | M&L for rendering 15mm thick on fair faces of brick/concrete surfaces in CM 1:4 finished even and smooth without using extra cement all as specified and as directed |
| 5 | M&L for preparation of newly plastered external wall & concrete surfaces & applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over 3mm wall care putty in 2 layers to match with the existing level and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over wall/concrete surfaces of any height complete all as directed. |
| 6 | S&F PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, step clamps, fixed to walls/floor/trenches etc and height of buildings upto G+6, including taking down, complete all as specified and directed. |
| 7 | S&F PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, step clamps, fixed to walls/floor/trenches etc and height of buildings upto G+6, including taking down, complete all as specified and directed. |
| 8 | S&F PVC (SWR) bends any radius, 110mm bore complete all as specified and directed. |
| 9 | S&F PVC (SWR) bends any radius, 110mm bore with access door complete all as specified and directed. |
| 10 | S&F 110mm dia PVC (SWR) junction, single (singleT) equal or unequal with access door complete all as specified and directed. |
| 11 | S&F 110mm dia,(PVC (SWR) branch piece,double (double Y) equal or unequal complete all as specified and directed. |
| 12 | S&F PVC (SWR) bends any radius, 75mm bore complete all as specified and directed. |
| 13 | S&F PVC (SWR) bends any radius, 75mm bore with access door complete all as specified and directed. |
| 14 | S&F 75mm dia PVC (SWR) junction, single (singleT) equal or unequal with access door complete all as specified and directed. |
| 15 | S&F 75mm dia,(PVC (SWR) branch piece,double (double Y) equal or unequal complete all as specified and directed. |
| 16 | Demolition of cement concrete of Roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work including removal of debris outside MoD land all as per specified and directed. |
| 17 | M&L for PCC 1:2:4, Type B-0, using 12.5mm graded stone aggregate, 50mm thick for floors,paving,Coving etc complete all as specified and directed |
| 18 | M&L for Complete removal of existing treatment & making good of cracks with crack putty of external wall surfaces & applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over wall/concrete surfaces of any height & covering undulations with putty complete all as directed. |
| 19 | Cutting of small trees/plants at the stem and removal of the roots of the plants by using acids, chemicals/burning with blow lamp, cutting around the spot for removing the roots of any size and making good with cement mortar 1:3 including two coats of cement based paint/acrylic emulsion upto height 6 storey complete all as specified and as directed. Please Enable Macros to View BoQ information |