| 1 | Repair / maintenance of internal light fitting of any type like tube lights / wall bracket light fittings / ceiling lights / bulk head light / mirror lights etc in its position, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like tube rod/batten, side holders, holders, lamps etc all as directed by Engr-in-charge. Note: (i) The rate against the above mentioned item is deemed for cost of labour only. (ii) Cost of spares like capacitor, lamp holder, connector, connection wire etc. replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (iii) The contractor/ his representative will report to concerned Engr-in- Charge / JE E/M at 0900hrs daily to collect the list of defects and will submit the completion report to the JE E/M/ Engr-In-Charge.In case contractor/ his rep do not receive complaint in morning, a recovery of Rs 50 per Complaint shall be recovered which remains pending due to non availability of contractor manpower. |
| 2 | (iv) Contractor will provide veh, ladder, any other tools & plants required at site at his own costs.(v) The contractor shall maintain proper record of repair / maint in a binded compliant register and complaint slip books duly signed by the user and bringing out the details of spares replaced and get it authenticated from concerned AGE/JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings . |
| 3 | Taking down carefully existing point wiring any type (light/fan/socket) including all accessories wire, casing caping/conduit, screws etc and making good the disturbed surfaces complete as specified and directed by Engr-in-Charge. |
| 4 | M&L point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metalic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, suitable for switches, sockets, fan regulator etc complete all as specified and directed , for the following :-Note:- Contractor shall make good all disturbed surfaces at his own cost without any extra claim. |
| 5 | One light/fan / exhaust fan point controlled by one, one way switch |
| 6 | One Switch socket outlet point controlled by one switch on independent boad |
| 7 | One switch socket outlet, three pin 5 amps on the same board |
| 8 | One light point controlled by two, two way switch |
| 9 | One Bell/Buzzer Per Points controlled by one bell push button |
| 10 | Description all as per item No.3.0 above but using 2.5 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly etc complete all as specified and directed. |
| 11 | Supply only of switch piano flush type 5 Amps SP one way complete as specified and directed by Engr-in-Charge. |
| 12 | S & F in replacement of switch piano flush type 5 Amps SP one way complete as specified and directed by Engr-in-Charge. |
| 13 | Supply only of switch piano type 15 Amps SP one way complete as specified and directed by Engr-in-Charge. |
| 14 | S & F in replacement of switch piano type 15 Amps SP one way complete as specified and directed by Engr-in-Charge. |
| 15 | S & F in replacement of switch socket combination 5/6 Amps flush mounted 5 pin multi purpose complete as specified and directed by Engr-in-Charge. |
| 16 | S & F in replacement of switch socket combination 6/16 Amps flush mounted 3/5 pin multi purpose complete as specified and directed by Engr-in-Charge. |
| 17 | S&F in replacement of socket outlet 5/6 Amps 2in 1, flushtype, 3 pin complete as specified and directed by Engr-in-Charge. |
| 18 | Supply only of socket outlet 5/15 Amps, 2 in 1, flush mounted 3/5 pin multi purpose all as specified. |
| 19 | S&F in replacement of socket outlet 5/15 Amps, 2 in 1, flush mounted 3/5 pin multi purpose all as specified. |
| 20 | S&F in replacement for ceiling rose, 3 terminals PVC/Polycarbonate, isolated body complete as specified and directed by Engr-in-Charge. |
| 21 | M&L in replacment of fan regulator electronic five step flush type suitable for 1200/1400 mm sweep fan 100 W & compatible with existing switch board as specified and directed by Engr-in-Charge. |
| 22 | M&L in replacment of fan regulator electronic five step flush type suitable for 1200/1400 mm sweep fan 100 W & compatible with existing switch board as specified and directed by Engr-in-Charge. |
| 23 | S&F in replacement Bell push, flush type 5 amp complete as specified and directed by Engr-in-Charge. |
| 24 | Supply Only of door bell AC 230 volts single phase ding dong type complete as specified and directed by Engr-in-Charge. |
| 25 | M&L in replacement of door bell AC 230 volts single phase ding dong type complete as specified and directed by Engr-in-Charge. |
| 26 | Supplying, laying, jointing and testing in repair in trenches, wall & floor steel water tubing galvanised medium grade conforming to IS-1239 with all fittings of sizes 15 mm bore complete. |
| 27 | S&F in replacement Lamp Holder PVC/Polycarbonate type with cord grip cap suitable pendent fittings complete all as specified and directed. |
| 28 | M & L for Point wiring with colour coding as per IS, with multistranded copper conductor 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLSH Cable conforming to IS: 694-1990 PVC insulated, unsheathed copper conductor cable drawn through in and including heavy duty PVC concealed conduit of white/ ivory colour including all accessories after cutting chasing in wall of any type /ceiling etc, incl making good of disturbed surface to match the existing surface complete etc including heavy duty ISI marked, with GI sunken & hylam sheet / PVC box suitable for switches, sockets, fan regulator etc complete all as specified and directed for the following :- Note:- Contractor shall make good all disturbed surfaces at his own cost without any extra claim. |
| 29 | One light/fan / exhaust fan point controlled by one, one way switch |
| 30 | Switch socket outlet point controlled by one switch on independent boad |
| 31 | One switch socket outlet, three pin 5 amps on the same board |
| 32 | One light point controlled by two, two way switch |
| 33 | One Bell/Buzzer Per Points controlled by one bell push |
| 34 | Description all as per item No.22 above but using 2.5 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly etc complete all as specified and directed. |
| 35 | M&L for Taking down carefully sub main wiring of any type and size and making good disturbed surfaces complete as directed by Engr-in-Charge. |
| 36 | M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 1.5 Sqmm , 1100 Volts grade in and including PVC Conduit/casing caping medium grade not less than 25 mm complete with conduit accessories and copper cable 1.5 sqmm continuous earth wire complete all as specified and directed (Two runs of 1.5 Sqmm cable with 01 run of 1.5 Sqmm earth wire along with casing caping/conduit shall be measured as one RM) |
| 37 | M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with conduit accessories and copper cable 2.5 sqmm continuous earth wire complete all as specified and directed (Two runs of 2.5 Sqmm cable with 01 run of 2.5 Sqmm earth wire along with casing caping/conduit shall be measured as one RM) |
| 38 | M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with conduit accessories and copper cable 4 sqmm continuous earth wire complete all as specified and directed (Two runs of 04 Sqmm cable with 01 run of 4 Sqmm earth wire along with casing caping/conduit shall be measured as one RM) |
| 39 | M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 6 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with accessories and copper cable 6 sqmm continuous earth wire complete all as specified and directed (Two runs of 06 Sqmm cable with 01 run of 6 Sqmm earth wire along with casing caping/conduit shall be measured as one RM) |
| 40 | M&L for secruing loose wiring and repair to point wiring with necessary rigid non metalic PVC casing caping double lock type/ PVC conduit ISI marked of size not less than 25 mm inclusive all accessories and suitable fixing arrangement for PVC Conduit/Casing caping complete as specified and directed by Engr-in Charge. |
| 41 | Supply Only of modular five step type fan regulator upto 100W, 2 module suitable for operation on 230 V supply all as specified and directed |
| 42 | Supply Only of modular switch 6 amps one way one module all as specified and directed. |
| 43 | Supply Only of modular switch 16 amps one way one module all as specified and directed. |
| 44 | Supply Only of modular Socket, 6A - 2/3 pin 2 module all as specified and directed. |
| 45 | Supply Only modular Socket, 6/16A - 2/3 pin 2 module all as specified and directed. |
| 46 | S&F in replacement MCB DB 12 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 100-200 Amp rating busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed by the Engr-in-Charge. Note - (a) MCBs will be measured & paid separately under respective item of sch A, if required to be replaced. (b) Contractor shall make good all disturbed surfaces at his own cost without any extra claim. |
| 47 | Dittto all as per item no 35 above but 08 way SPN DB |
| 48 | Dittto all as per item no 35 above but 04 way SPN DB |
| 49 | S&F in replacement factory made epoxy powder coated Distribution Board TP & N 4 way double door (VTPN MCCB DB ) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 160 Amp copper bus bar (Min) , neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified Note:MCBs/ MCCBs will be measured and paid seperately under respective Sch A item in the schedule |
| 50 | M&L in repair for earthing complete with galvanized steel earth plate electrode size 600 mm x 600 mm x 6 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth lead 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth wire on pole or control board and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. RCC cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed. |
| 51 | Note :- (a) The rate quoted include the cost of GI strip & GI protection pipe light 40mm dia bore light grade upto 7.5 metres. PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner . (b) Value of earth resistance should be less than 1 Ohms for equipments earthing and less than 5 ohms for LA & Power Supply earthings. (C) 1. If result is not satisfactory then contractor will do 2nd earthing on his own cost. |
| 52 | M&L in repair for PVC Surface box for mounting, switches, sockets, fan regulator etc with and including cover laminated sheet cover of size 250mmx200mm and 50mm deep and making good of disturbed surfaces as per existing, complete all as specified and directed. |
| 53 | M&L in repair for PVC Surface box for mounting, switches, sockets, fan regulator etc with and including cover laminated sheet cover of size 200mmx150mm and 50mm deep and making good of disturbed surfaces as per existing, complete all as specified and directed. |
| 54 | M&L in repair for PVC Surface box for mounting, switches, sockets, fan regulator etc with and including cover laminated sheet cover of size 100mm x100mm and 50mm deep and making good of disturbed surfaces as per existing, complete all as specified and directed. |
| 55 | M & L for repair/replacement of Meter Panel board/LT panel/ Switchgear panel doors made up of MS CRCA sheet powder coated (7 tank) having 2 mm thickness , cut to size and pressed to shape required as per size of existing Meter Panel/LT panel installed/ located at various locations/site including welding, fixing of hinges to sheet, provn of suitable locking arrangements, fixing of sliding bolts (sliding bolts shall be measured under relevant item of Sch) and further fixing to LT panel/ Switchgear panel for fixing complete all as per directed by Engr in charge.Note : The contractor shall take actual measurements of LT panel doors on site for suitable fitting of the doors. |
| 56 | Supply only butt hinges, heavyweight, cold rolled mild steel of size 125 mm suitable for MS CRCA sheet of thickness 2 to 3.15 mm complete all as specified and directed by Engr-in -Charge. |
| 57 | Supply only Mild steel sliding door bolts, plate type, stainless steel finish, with bright bolt not less than 12mm dia, length 250mm with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate suitable for LT panel/Meter Panel door complete all as specified and directed by Engr-in -Charge. Please Enable Macros to View BoQ information |
| 58 | Supply only Mild steel sliding door bolts, plate type, stainless steel finish, with bright bolt not less than 12mm dia, length 250mm with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate suitable for LT panel/Meter Panel door complete all as specified and directed by Engr-in -Charge. Please Enable Macros to View BoQ information |