| 1 | Dismantling Stone slabs and tiles of any description or thickness layed bedded and pointed in any mortar in floors, aprons etc. and removing the debris outside MD land upto requisite distance of 15 km. Note : Old stone slabs cattered in sch of credit. |
| 2 | Roughening surfaces of old concrete floor by hacking and by picking, sweeping clean and washing down with water to remove dust, etc. to receive tiles all as specfied and directed |
| 3 | Demolition of cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing the debris outside MD land upto requisite distance of 15 km complete all as specified and directed by EIC. |
| 4 | M&L 75 mm thick Cement concrete type B- 2, 1:4:8 (40mm graded aggregate) as in sub base complete all as specified and directed by EIC. |
| 5 | M&L for Pre polished Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete, laid over and including screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to recive tiles complete all as specified and directed. |
| 6 | M&L for Pre polished Kota stone slab 20-25mm thick in riser of steps, skirting, dadoand pillar laid over and including backing coat of 10mm thick in CM 1:3. and jointed with with grey cement slurr mixed with pigment to match the shade of the slab complete incl taking down old plaster and removing the debris outside MD land upto requisite distance |
| 7 | M & L PCC type 1:3:6 (40 mm graded aggregate) as in surface channels and drains. mixed with WPC(water proofing compound) as per manufacturer's instructions including demolition of cement concrete (Reinforcement cut as required to facilitate demolition) in ground floors (below or above ground level) not exceeding 15cm thickness and removing the debris outside MD land upto requisite lead all as specified and directed |
| 8 | Supply only intergal water proofing compound. (ISI marked). |
| 9 | Extra for forming fair finished drain or channel 30 CM inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc, |
| 10 | M&L for providing leakage/seepage proof coating on the wall surface of drain by applying primeseal primer of Dr fixit or equivalent of M/s STP Ltd under torch dry condiiton and subsequently applying two coats of water proof decorative elastomeric coating Note The aforesaid treatment shall be got executed by the contractor frpom authorised applicator of the manufacturer and also necessary documents in support of the above shall be submitted by the contractor complete all as specified and directed. |
| 11 | M & L for preparation of newly plastered surface and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including requisite scaffolding with all safety equipments upto 15 mtr height complete all as specified and directed by EIC. |
| 12 | M&L for Complete removal of existing treatment by washing, rubbing down and stopping of old surfaces on walls, preparation for wall surface and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including requisite scaffolding with all safety equipments upto 15 mtr height complete all as specified and directed by EIC. |
| 13 | M&L for three coats of white wash on old surface of walls including requisite scaffolding with all safety equipments upto 15 mtr height complete all as specified and directed by EIC. |
| 14 | S&F 150 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls using clamps including filling the joint between aluminium sheet and PVC pipe with water proofing material complete all as specified and directed. including taking down of old pipe of any diescription. |
| 15 | Dismantling GI Sheets (corrugated, semi corrugated,plain etc sheets in roof coverings, valley gutters complete all as specified and directed. |
| 16 | S&F Pre- painted galvalume sheet having aluminum zinc coating sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fastners etc complete all as specified and directed |
| 17 | S&f for Fibre glass reinforced translucent corrugated sheeting 2mm thick with two corrugations side lap fixed using self tapping screws complete all as specified and directed by EIC. |
| 18 | Taking down eaves gutters (size upto 1.20m wide) and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store including necessary scaffolding (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by EIC. Please Enable Macros to View BoQ information |
| 19 | Taking down eaves gutters (size upto 1.20m wide) and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store including necessary scaffolding (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by EIC. Please Enable Macros to View BoQ information |