| 1 | Demolition of brick work or stone/boulder masonry, built in cement mortar complete all as specified and as directed. |
| 2 | M & L for Walling of random rubble uncoursed , brought upto courses well bonded, bedded and solidly hearted built in CM 1:6 all as specified and directed by Engr-in-Charge. |
| 3 | Walling of random rubble uncoursed (but except stone), brought upto courses well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified and as directed. |
| 4 | M&L for Hammer dressing with maximum depression on face from straight edge held against the dressedsurface n exc. 40 mm for granite or trap stone face stones and dressing of face beds and joints, all as specified and as directed. |
| 5 | M&L for PCC 1:2:4 Type B-1 using 20mm graded aggregate as in copings etc including necessary formwork etc complete all as specified. |
| 6 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each complete as all specified and directed |
| 7 | M & L Cement concrete type B0 1:2:4 (12.50 mm graded aggregate) as in roof padding, roof kerbs or mud stops including demolition of existing roof padding and removal of debris to outside MD land all complete all as specified and as directed. |
| 8 | M&L for Roof Treatment including the following complete all as specified and as directed:-(i) Taking out of existing water proofing treatment roughening surfaces of concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing with neat cement slurry @ 3.00 kg of cement per Sqm and PCC padding (30 mm theack). (ii) 10 mm thick rendering in CM 1:4 on surface mixed with WPC @ 2% by weight of cement as per manufacturers instructions. (iii) Cleaning of plastered surface and applying one coat of hot blown bituminous primer conforming to IS -3384 (latest) @ 0.5 Ltr / Sqm. (iv) APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by torch application complete all as specified. Polymeric membrane shall be taken to a height of 30 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (v) Applying one coat of bituminous aluminium primer over APP membrane @ 0.11 Lit / Sqm. Note:- (a) Primer, APP membrane & bituminous aluminium paint shall be of same manufacturer and executed through applicator authorised by the approved manufacturer only. (b) Membrane shall be laid with side overlap of 100 mm and end overlap of 150 mm as per manufacturers instruction. (c) PCC Padding & WPC will be measured and paid separately. |
| 9 | S&F for Wire netting of stainless steel wire 1.4mm dia fixed with tinned tacks of stainless steel wire staples size of mess 12mm complete all as specified and directed. |
| 10 | S & F 5.5 mm thick sheet Glass ordinary quality,in any size fixed with glass putty or fitted with beads in squares exc 0.50 sqm in each pane in window and frames complete all as specified and as directed. |
| 11 | M&L Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of ancolour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including Dismantling of AC sheeting of any type in roof coverings complete all as specified and directed. |
| 12 | S&F rolled mild steel Framed work of grade Fe-410, (Gde E- 250), as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering to Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging , also fastening and fixing including dismantling structural steel work of any description not otherwise provided for complete all as specified and directed. |
| 13 | M&L for rubber door seal gasket n.exc 10 cm wide all round the shutter of steel door to seal airtight inside the room omplete all as specified and as directed. |
| 14 | S&F Rolled Mild steel for roof trusses (framed),Fe-410, (Gde E- 250), framed trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) with distance pieces, cleats etc. including dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 15 | M & L Cement concrete type B1 1:2:4 (20 mm graded aggregate) as insurface channels an drains all complete all as specified and as directed. |
| 16 | Demolition of cement concrete of any description from any position including removing the demolition material complete all as specified and as directed. |
| 17 | Material and labour for 75 mm thick, PCC 1:3:6 Type C-2 using 40mm graded aggregate as in Plinth protection etc surface finished even and smooth with using extra cement complete all as specified. |
| 18 | Material and labour for 75 mm thick, PCC 1:2:4 Type B-1 using 20mm graded aggregate with spike rolling to surfaces or making impressions of expanded metal while the concrete is green, over and including 100 mm thick, PCC 1:3:6 Type C-2 using 40mm graded aggregate as in footpath , hard standings etc surface finished even and smooth with using extra cement complete all as specified. |
| 19 | S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed. |
| 20 | Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 21 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in two layers of 10 mm and 5 mm thickness in cement mortar (1:4) and finished even and fair without using extra cement including mixing of water proofing compound in 5 mm thick layer as required as per manufacturers instructions complete all as specified and directed. (WPC will be measured & paid separately) |
| 22 | Supply only Integral waterproofing compound for cement concrete, complete all as specified and as directed. |
| 23 | M & L for preparation of new plastered surfaces of walls and applying Two or more coats of Premium acrylic distemper having VOC less than 50 gm/litre of required shade (Company Depot Tinted) over a coat of priming coat complete all as specified and directed. |
| 24 | M&Lfor rendering 5mm thick in cement mortar 1:3 on Ceiling brick / concrete surfaces, finished even and smooth without using extra cement all as specified and directed. |
| 25 | M & L for preparation of plastered surfaces of concrete / masorny walls by brooming down or steel wire brushes scrapping down smoke , soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying a coat of cement wash complete all as specified and directed. |
| 26 | M&L preparing new wall surfaces plastered or unplastered and Providing and applying Two or more coats of 100% Premium acrylic emulsion paint ( Camouflage patten ) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 27 | M & L for preparation of new plastered surfaces of walls and applying Two or more coats of Premium acrylic distemper having VOC less than 50 gm/litre of required shade (Company Depot Tinted) over a coat of priming coat complete all as specified and directed. |
| 28 | M & L for preparation of new plastered surfaces of ceillings and applying Two or more coats of Premium acrylic distemper having VOC less than 50 gm/litre of required shade (Company Depot Tinted) over a coat of priming coat complete all as specified and directed. |
| 29 | M & L for preparation of New plastered surfaces and applying Three coats of white wash on Ceiling complete all as specified and directed |
| 30 | M&L preparing old wall surfaces plastered or unplastered and Complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and directed by Engr-in-Charge. |
| 31 | M & L for complete removal of existing treament and preparation of surfaces of walls and applying Two or more coats of Premium acrylic distemper having VOC less than 50 gm/litre of required shade (Company Depot Tinted) over a coat of priming coat complete all as specified and directed. |
| 32 | M & L for complete removal of existing treament and preparation of plastered surfaces of ceillings and applying Two or more coats of Premium acrylic distemper having VOC less than 50 gm/litre of required shade (Company Depot Tinted) over a coat of priming coat complete all as specified and directed. |
| 33 | M & L for complete removal of existing treatment and preparation of surfaces and applying Two coats of white wash on ceilings complete all as specified and directed |
| 34 | M&L for applying two coat of fire resistant / intumescent paint on new steel surface over a coat of primer including preparation of surface of any description over 10 cm width or girth complete all as specified and directed. |
| 35 | M&L for applying two coat of fire resistant / intumescent paint on old steel surface over a coat of primer including preparation of surface of any description over 10 cm width or girth complete all as specified and directed. |
| 36 | S&F in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and connecting to earth strip complete all as specified and as directed. |
| 37 | S&F in repairs galvanized iron strip 32x6 mm size with saddles and fixing screws etc. for roof conductors and down conductors above ground on porcelain insulators suitable for running strip all as specified and as dircted. |
| 38 | S&F in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed. |
| 39 | S&F in repairs Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground on porcelain insulators suitable for running strip all as specified and as dircted. |
| 40 | Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 x 6 mm size GI strip [Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 5 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. including dismantling and taking down old earthing. complete all as specified. |
| 41 | M&L for Pre-cast cement concrete block masonry Type B1, 1:2:4 mix (using 20mm size graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in mortar CM 1:6 complete all as specified. |