| 1 | Items : |
| 2 | Removing dry or oil bound distemper by a washing and scraping and sand papering the wall surface smooth including necessary repairs to scratches complete. |
| 3 | Distempeing (Two coats) with oil bound washable distemper of approved brand and manufacture and of required shade on wall surfaces to give an even shade, over and including a priming coat with alkali resistance primer of approved brand after thoroughly brushing the surface and other foreign matter and also including preparing the surface even and sand parpered smooth. |
| 4 | Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete |
| 5 | Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint, interior to give an even shade including cleaning the surface of all dirt, dust and otherforeign matter sand papering and stopping. |
| 6 | Applying two coats of putty & two coats of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth. |
| 7 | Supply and apply of Asian paints Smartcare Damp Proof -single component fibre reinforced acrylyc coating.The coating must be applied in three coats with first coat at 33% dillution and the remaining two coats without dillution.for priming coat ,no additional primer is allowed.The coating should be white in colour and shall carry TUV test certificate, singapore with SRI value of 105.6. the coating shall also have anticarbonation property with waterproofing protectionup to 7 bars hydrostatic pressure as Directed by Engineer incharge. |
| 8 | Providing and fixing flase celling 600 x 600mm cement sheet with Aluminium framing as directed by engineer-in-charge. |
| 9 | Dismentaling of sheet roofing including ridges, Hips, Valleys,Gutters etc. stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(i) G.I.sheet roofing. |
| 10 | Excavation for foundation upto 1.5 m depth includingsorting out and stacking of useful materials anddisposing off the excavated stuff upto 50 Meter lead.(C)Hard Murrum |
| 11 | Excavation for foundation for depth from 1.5 m to 3.0 mincluding sorting out and stacking of useful materials anddisposing off the excavated stuff upto 50 Meterlead.(C) Hard Murrum |
| 12 | Filling in foundation and plinth with brick Bats Chhara inlayers of 20cm. thickness including watering, remmingand consolidating etc. complete. |
| 13 | Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mmnominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth |
| 14 | Providing formwork of ordinary timber planking so as to give arough finish including centering shuttering strutting and proppingetc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situreinforced concrete and plain concrete work in. (A) FoundationsFootings Bases of Columns etc. and Mass concrete. |
| 15 | Providing and laying controlled cement concrete M.200 and curing complete excluding the cost of formwork and reinforcement forreinforced concrete work in (A) Foundations, footings, Base of columns and Mass concrete |
| 16 | Providing and laying controlled cement concrete M.200 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (D) Columns, Pillars posts and struts upto floor two level. |
| 17 | Providing and laying controlled cement concrete M.200 and curing complete excluding the cost of formwork and reinforcement forreinforced concrete work in (C) Slabs,landing,shelves,BalconiesLintels, Beams, Girders and Cantilever upto floor two level. |
| 18 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating eachdisposited layer by ramming and watering. |
| 19 | Providing formwork of ordinary timber planking so as to give arough finish including centering shuttering strutting and proppingetc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situreinforced concrete and plain concrete work in. (G) ColumnsPillarsPosts and struts. (2)Circular or curved in Plan. |
| 20 | Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (D) Columns, Pillars posts and struts, upto floor two level. |
| 21 | Providing and laying controlled cement concrete M.250 and curingcomplete excluding the cost of formwork and reinforcement forreinforced concrete work in (C) Slabs,landing,shelves,Balconies, Lintels,Beams, Girders and Cantilever upto floor two level. |
| 22 | Providing formwork of ordinary timber planking so as to give arough finish including centering shuttering strutting and proppingetc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situreinforced concrete and plain concrete work in. (B) Flat surfaces such as soffits of suspended floor roof slabs Landings and the like.(2) Floors etc. above 200mm in thickness. |
| 23 | Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement forreinforced concrete work in (C) Slabs,landing,shelves,Balconies, Lintels, Beams, Girders and Cantilever upto floor two level. |
| 24 | Brick work using common burnt clay building bricks havingcrushing strength not less than 35 kg./Sq.Cm. in foundation andplinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand) (A)Modular |
| 25 | Brick work using common burnt clay building bricks havingcrushing strength not less than 35 kg./Sq.Cm. in foundation andplinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(A)Modular.Extra for brick work in superstructure above plinth level upto floor two level (A) Modular |
| 26 | (i) Half brick masonry in common brunt clay building brickshaving crushing strength not less than 35 Kg/Sq.Cm. in Cementmortar 1:4 (1- Cement : 4 -coarse sand ) in foundation andplinth (A) Modular |
| 27 | Providing and laying black polished granite stone slab 25mm thick in window sills,risers of steps,wall,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. |
| 28 | Providing and fixing FRP frame size 125x65 mm and 35mm thickFRP shutter having extra reinforcement on sides & edges in polish finish. The core of the shutter & frame is to be filed up with injected polyurethene foam done in situ alongwith embeddedwooden pieces for stiffening & also taking hinges & fintures. The whole FRP frame & shutter is to be water proof weather proof, termite proof & resistance to mild acid/alkali. Rates are to beinclusive of S.S hinges with necessary screws & alluminium S.S fixtures & fastenings & fastener sleeve. |
| 29 | Providing and fixing standared extruded of alluminium sectionof size 63.50 x 38.10 x 1.95 mm @ Wt 1.094Kg / Rmt withcolour anodized alluminium frame with 5 mm thick transparent bronze colour tinted float glass with colour anodized alluminium frame for ventilation with 5 mm thick frosted glass as details etc complete for.window |
| 30 | Providing 15mm thick cement plaster in single coat on Rough(Similar)side of single or half brick walls for interior plasteringupto floor two level and finished even and smooth in (ii) Cementmortar 1:4 (1-cement :4-sand) |
| 31 | Providing 20 mm thick double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar1:2 (1 Cement : 2 Coarse sand) finished with trovel including scaffolding curing etc. complete. |
| 32 | Providing and fixing Urinal of approved quality includingconnection with trap and with integral longitudinal flush pipe.(A) Squating plate pattern white earthenware 550mm x 300mm. |
| 33 | Providing and fixing wsh down water closet (European type, W.C.Pan) with integral P or S trap including jointing the trap with soil pipe in Cement Mortar 1:1 (1-Cement : 1-fine sand) (Seal and cover to be measured and paid for separately)(A) vitreous China Pattern :(i) in white colour |
| 34 | Providing and fixing washbasin with single hole for pillar tap withC.I. or M.S. brackets painted white including sutting holes andmaking good the same but excluding fittings.(A) Vitreous China:(ii) Flat Back washbasin 550 mm x v 400mm size. (i) In white colour. |
| 35 | Providing and fixing 100mm sand cast iron grating for gully, floor or Nahni trap. |
| 36 | Providing and fixing screw down bib taps of following size.(A)Brass screw down bib tap polished bright. (i) 15mm dia. |
| 37 | Providing and fixing pillar tap, capstan head, screw down highpressure with screws, shanks and back nuts. (i) 15mm dia. |
| 38 | Providing and fixing chromium plated brass half trun flush cock of approved quality including fixing in pipe line etc. complete.(i)20mm dia. |
| 39 | Providing and fixing ball cock of approved. quality as directed.(A)Copper Metal (i) 25mm dia. |
| 40 | Providing erecting and fixing double coated ISI water tank ofrequired capacity each with all necessary fittings and connectionetc. complete on terrace |
| 41 | Providing laying and jointing in true line and level 15mm dia.U.P.V.C. Pipe ( SCH- 40) for cold water including fittings asapproved by Engineer In Charge. Pipe shall be fixed on the wallwith the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 42 | Providing laying and jointing in true line and level 25mm dia.U.P.V.C. Pipe ( SCH- 40) for cold water including fittings asapproved by Engineer In Charge. Pipe shall be fixed on the wallwith the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 43 | Providing laying and jointing in true line and level 50mm dia.U.P.V.C. Pipe ( SCH- 40) for cold water including fittings asapproved by Engineer In Charge. Pipe shall be fixed on the wallwith the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 44 | Providing, laying and jointing in true line and level 110 diametreU.P.V.C (Type B) conforming to IS 13592-1992 with one end plainand other end socketed with rubber ring, & fittings conforming toISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mmdiametre x 149 mm length x 145 mm heigh at every 2000 mm centerto center or shall be concealed in walls as directed includingnecessary fittings such as bends, shoes etc. including testing ofpipes and joints and jointed with adhesive solvent cement includingcost of all materials. |
| 45 | Providing and fixing 600mm x 450mm bevelled edge mirrror ofsuperior glass mounted on 6mm thick A.C. sheet or plywood sheetand fixing to wooden pluge with C.P. brass screws and washers |
| 46 | Extra over item 24.1 for providing salt Glazed stoneware fittings.(iii) Single Junction of required angle of following internal diametrs. (A) 100mm. |
| 47 | Providing and fixing 100mm size P or S trap for water closetsquatting pan including jointing the trap with the pan and soil pipe in cement Mortar 1:1 (1-Cement : 1-Fine sand)(A) Vitreous China |
| 48 | Providing and fixing in Cement Mortar 1:3 (1-Cement : 3-coarsesand)a, pair of white vitreous China 250mm x 130mm x 30mmfootrest to long pattern squatting pan water closet. |
| 49 | Providing and fixing plastic seat and cover for wash down watercloser with C.P. brass hinges and rubber buffers. (B) Black plasticseal and cover. |
| 50 | Providing and fixing C.P. brass waste for washbasin or sink. (A)32mmdia. |
| 51 | Providing and fixing cast iron spigot and socket soil, waste andventilating pipes of the following nominal size.(C) 100mm dia. |
| 52 | Providing and fixing Gun metal check or non-return fullway wheel valve.(C) 25mm dia. |
| 53 | Providing and fixing cast iron spigot and socket soil, waste andventilating pipes of the following nominal size.(B) 75mm dia. |
| 54 | Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24'' in flooring treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse sand ) finishing with flushpointing in white cement. |
| 55 | Providing and laying polished kota stone slab 25mm thick in risersof steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. |
| 56 | Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24'' in skrting risers of steps and dedo on 10mm thick cement plaster 1:3 (1- cement : 3-coarse sand) and jointed with white cement slurry |
| 57 | Providing TMT Bar FE 500D reinforcement for R.C.C work including bending, binding and placing in position complete upto floor two level with fusion bonded Epoxy coating not less than 175 micron thickness and up to 300 micron to reinforcement bars as per IS-13620-1993/ASTM-775 M including testing of coating at plant and all taxes (A) 10 mm to 16 mm dia bar |
| 58 | Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block 60mm thick with grade of concrete M300 pnumatic compressed / vibrated mechanically and as per approved design Confirming to IS 15658 : 2006 including 35 mm Sand layer for levelling and filling the joint with sand in proper line and level as per guidlines of IRC : SP 63-2018 etc. Complete. |
| 59 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including profile correction with 100 mm thickness including premixing the material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoRTH. |
| 60 | Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm length,30cm height and 15cm thick of M200 grade concret as per approved design and including excavation for fixing in proper line and level,filling the joint with C:M 1:3 (1cement:3fine sand) etc complete. |
| 61 | Point wiring for Light / Bell with 2-1.5 sq. mm & earth wire of 1.5 sq. mm (green) both are of ISI marked 1.1 KV grade FR PVC insulated multi strand copper wires, in following type of pipe to be erected concealed in / on surface on wall / ceiling complete with 6 A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on/ in wall / ceiling as per pipe erected, with necessary Lamp holder / ceiling rose / H.D. Connector as directed.(C)with oval conduit / pvc casing capping double lock type.(Cat. III) |
| 62 | Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm. (green) both are of ISI marked 1.1 KV Grade FR PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall / ceiling complete with 6A Modular type switch and hum free EME four or more step type electronic fan regulator with separately mounted and accessories with earth continuity of following type erected on PVC/Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on/ in wall / ceiling as per pipe erected, with necessary ceiling rose / H.D. Connector as directed.(c)with oval conduit / pvc casing capping double lock type. (Cat-III) |
| 63 | Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection. As desired by Engineer In charge(1)One No. SP 6 Amp.(Cat- III) |
| 64 | (2) One No 5 pin plug (Cat- III) |
| 65 | (7) Blank Plate Single.(Cat - III) |
| 66 | Supplying & erecting UPVC Mini trunking (PVC Casing-n-Capping) having double-locking arrangement with grooves, trunking of size not below 12.5 mm in height as per IS with accessories of PVC/Resin polypropylene not below 1.8 mm thick duly sealed in joint & erected on wall/celling of following size. (2) 25 mm. |
| 67 | Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FR PVC insulated stranded wire of green colour for earth continuity of following size (c) with oval conduit/pvc casing capping double lock type. (b) 2 wire 2.5 sq. mm |
| 68 | Miniature circuit breaker single pole 6A to 32A. Suitable to operate on 240V. A.C. system and having breaking capacity 10 KA to be erected in existing box. Confirming to IS 8828 / 1996 with ISI Mark. (Cat-III). |
| 69 | Providing and erecting four pole MCB isolator A.C. 22 duty confirms to IS 13947-3 in existing box. (b) for 63 Amp. (Cat-III). |
| 70 | Plastic enclosure fitted with DIN rail suitable for incorporating One/Two nos MCB. |
| 71 | Providing and erecting Sheet Steel powder coated MCB distribution board – flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 with out MCB to house appropriate nos. of MCBs. (The DBs should be used of same company of MCB to be used). (J) Three phase 4 way SS Double door for single phase outgoing horizontal box |
| 72 | Providing and erecting Approved make Power saving 50 watt Ceiling fan with double ball bearing ISI mark with condenser A.C. 230 V. 50 Cys. 1200 mm. sweep complete having 3 blades with aluminium blades with, canopy and 30 cms. down rod erected with 24/0.2, 3 core flexible wire with earthing [ Make shall be approved by Engineer in charge] |
| 73 | Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA polyester powder coated and high U.V. & corrosion resistance with diffuser and/or Polycarbonate optics with with company mark/name 120 to 300 V, Power Factor more than 0.9, THD < 10 %,CCT 4000 K to 6500K, Uniformity ratio >0.7,Luminaire efficiency> 85 lumens/watt,LED driver efficiency > 85 %CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/Bridgelux(U.S.A.) make LED used for luminaire. (Each fitting required LM-79 & LM-80 Certificates).(A) Tube Light with integral/ non-integral driver.(c) 16-18 Watts, Surge - 4KV, IP-20, 4 feet. (Cat-III) Make:Wipro, Havells, Philips, Bajaj, Surya, HPL. (as directed by Engineer-in-charge). |
| 74 | Supplying & erecting approved make low noise decorative exhaust fan having size 200mm with 1350 RPM with square frame ABS body with inbuilt lowers & square frame. |
| 75 | Removing dry oil bound distemer by washing and scrapping and sand preparing the on ceilings and sloping roofs including necessary repairs to scratches complete.Extra over item 33 for removing dry oil bound distemper on ceilingsand sloping roofs. Please Enable Macros to View BoQ information |