| 1 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 3 | Size of Tile 600x600 mm |
| 4 | 12 mm cement plaster of mix : |
| 5 | 1:4 (1 cement: 4 fine sand) |
| 6 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour |
| 7 | Two coats |
| 8 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 9 | In cement mortar |
| 10 | Dismantling old plaster/facia granite/skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 11 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 12 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 13 | For fixed portion |
| 14 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 15 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) |
| 16 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 17 | Providing and fixing of hydraulic floor spring to bear weight 80 kg for 12mm thichToughned glass door with all accessories and fixtures complete in all respect as per the entire satisfaction of engineer-in-charge. |
| 18 | Providing and fixing of wall panel of 12mm thichToughned glass inculding a openable shutter fixing with hydraulic floor spring with all accessories and fixtures complete in all respect as per the entire satisfaction of engineer-in-charge |
| 19 | Providing and applying white cement based putty of average thickness 1 mm @ 6 kg per 10 sqm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |