| 1 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels |
| 2 | WS-Ex-DBW-AlS) Drilling of borewell anywhere including transportation from one place to another place within Tamilnadu in alluvial soil or sedimentary strata of clay and sand or sand, stone, shale, pebbles, boulders etc., by first taking a pilot bore of 140 mm/150mm diaWS-Ex-DBW-150) d) Drilling of borewell in above 120m to 150m |
| 3 | WS-Ex-DBW-HR)Drilling of (150mm) vertical bores in hard rock area to any required depth as desired by TNPHC officials including labour charges for grouting the casing pipe after inserting the casing pipe in the drilling hole etc., and including transporting charges for the rig and supporting vehicles from one place to another place including hire and fuel charges as directed by the departmental officers. |
| 4 | WS-Ex-DBW-180) Drilling of borewell anywhere including transportation from one place to another place within Tamilnadu in alluvial soil or sedimentary strata of clay and sand or sand, stone, shale, pebbles, boulders etc., by first taking a pilot bore of 140 mm/150mm diae) Drilling of borewell in above 150m to 180m |
| 5 | WS-Ex-DBW-210) f) Drilling of borewell in above 180m to 210m |
| 6 | WS-Ex-DBW-240) g) Drilling of borewell in above 210m to 240m |
| 7 | WS-Ex-DBW-270) h) Drilling of borewell in above 240m to 270m |
| 8 | WS-EX-CS-Dia) Supply and delivery of following dia PVC casing pipies without excise duty as per IS 12818/2010 of approved quality for bore wells with average wall thickness of 8.0mm and inter / outer threaded ends with slots in standard length of 1m to 8mm both in horizontal and vertical cutting including transporting charges to site of work and all other taxes etc.,PVC Pipes160mm dia |
| 9 | WS-Ex-PVC EC-160) supplying and fixing of 160mm dia pvc end cap for borewell casing pipe of approved brand etc., |
| 10 | Supply and fixing of Bore cap using M.S. Flat of size 1 cm x 3mm and M.S. sheet on top with boltingarrangements for securing the cap in position(Bore caps with M.S.Couplings need not be made)6” Casing Pipes |
| 11 | WS-Ex-Ny R-BW) supply and delivery of required dia nylon rope of superior quality for submersible pumpset in borewell and as directed by the departmental officers (the quality of nylon rope should be got approved by the executive engineer before supply) |
| 12 | WS-Ex-SP-150mmØ-lpm x m) THREE PHASE SUBMERSIBLE PUMPSET SUITABLE FOR 150MM DIA BOREWELL AS PER IS 8034/2002 WITHOUT PANEL BOARD Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 %WS-Ex-SP-150mmØ-50x250)50 lpm x250 m |
| 13 | WS-Ex-FCC-3c) Supply and laying of PVC insulated and sheathed following core and sq.mm flat type copper cable confirming to IS 694/1990,cable for submersible motor etc.,WS-Ex-FCC-3x4) c) 3 core 4 sq.mm flat type copper cable |
| 14 | WS-IN/EX-P-Dia) supplying and delivery of following dia pipe including cost of all materials of best approved superior quality with isi mark etc all complete and as directed by the departmental officers. (the pipe should be got approved from the executive engineer before use)WS-IN/EX-GI B-B) 4. BendWS-IN/EX-GI B-50) f.50 mm Dia |
| 15 | GI Couplingf.50 mm Dia |
| 16 | WS-IN/EX-GI EL-50) GI Elbowf.50 mm Dia |
| 17 | WS-IN/EX-GI HN-50)GI Hex Nipple f.50 mm Dia |
| 18 | WS-IN/EX-GI Un-50)GI Union f.50 mm Dia |
| 19 | WS-IN/EX-GM GV-50)Gun Metal Gate Valvef.50 mm Dia |
| 20 | EL-IN-EF-TPN) Supply and fixing of follwing Triple pole main switch with fuse and neutral link on a suitable well varnished teak wood board including necessary interconnection,cost of all materials etc., all complete as directed by the departmental officers. (The quality should be got approved by the Executive Engineer before use).EL-IN-EF-TPN-63ab)63 amps triple pole main switch with fuse and neutral link |
| 21 | WS-Ex-DOL-TPPB) THREE PHASE PANEL BOARD- D.O.L WITH TWO LEVEL GUARD AND AUTO START Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ (± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately).b. 5 HP |
| 22 | WS-IN/EX-P-Dia) supplying and delivery of following dia pipe including cost of all materials of best approved superior quality with isi mark etcWS-Ex-UPVC CP-50d. 50mm Column Pipe |
| 23 | WS-IN/EX-P-Dia) supplying and delivery of following dia pipe including cost of all materials of best approved superior quality with isi mark etc WS-IN/EX-GI-50f. 50mm dia GI Pipe |
| 24 | WS-Ex-LC-S BW/OW) Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. |
| 25 | CN-F&S-PCS-M20-20/40-(5F)) Providing precast concrete slab for cupboard ward robes shelves, cover slab for chambers, Baffle walls side slabs of boxing around windows and other similar works in Standardised concrete mix M20 CN-SS-PCS-M20-20I. 20mm thickCN-SS-PCS-M20-20-(2F)c. In Second Floor |
| 26 | CN-SS-PCS-M20-20-(3F) d. In Third Floor |
| 27 | CN-SS-PCS-M20-20-(4F) e. In Forth Floor |
| 28 | EL-IN-WR-2x4m2) Run of main with 2 wires of 4 sq.mm. PVC insulated single core multi strand fire retardant flexible copper cable |
| 29 | JN-UPVC W-UPVC-2S) Supply and installation of two-track sliding UPVC windows shall utilize UPVC profile sections with an outer wall thickness of 2.30mm (±0.2mm), featuring an outer frame of 60mm x 52mm, a shutter of 66mm x 42mm x 50mm, an interlock of 45mm x 36mm, and a glazing bead of 24.5mm x 16mm. All frame, sash, and mullion profiles shall be reinforced, where required, with a 1mm thick GI steel section, and windows are to be equipped with security devices such as touch locks or crescent locks, nylon rollers, and an aluminium track |
| 30 | IJN-UPVC W-UPVC-3S W) Supply and installation of three-track sliding UPVC windows shall utilize UPVC profile sections with an outer wall thickness of 2.30mm (±0.2mm), featuring an outer frame of 112mm x 52mm x 112mm, a shutter of 66mm x 42mm x 50mm, an interlock of 45mm x 36mm, and a glazing bead of 24.5mm x 16mm. All profiles of frames, sash, and mullion shall be reinforced, wherever required, with a 1mm thick GI steel section. Each window is to be equipped with various security devices, such as touch locks or crescent locks, along with nylon rollers and an aluminium track for smooth operation, all supplied as per requirements, compliant with relevant specification |
| 31 | supply and filling of red soil, organic compost, good earth, river sand the soil mix to be sorted, graded mixed spread and leveled in specified locations & quantity (in loads- 3 units) red soil and good earth (200 cft) deep red in color, weed free, clod free organic compost (100) cft) brownish black, odor free, weed free etc |
| 32 | Labour charges for the levelling supplied red soil in specified location etc., |
| 33 | Supplying and planting of Mexican Grass including cost of pest control, transport, labour charges etc., |
| 34 | Supplying and planting the following in the excavated pits of size 0.30 x 0.30m filling with garden soil and planting shrubs / trees specfied below of minimum 0.35m height with necessary maintenance for the period of 1 months etc., a.) Royal Palm (12' height) |
| 35 | b.) Ficus( 4' height) |
| 36 | c.) Flowering Plants Exora |
| 37 | d.) Specimen Plants |
| 38 | e.) Alamanda flower Plants |
| 39 | Supplying and planting of Trees including earth work excavation, filled with manure and filling with red earth in the same pit and planting the following trees to a height of 180cm to 200cm from the ground level and maintaining them for the period of one month including watering, periodical manuring and replacing the trees if dead etc, |
| 40 | Providing Grooving in Granite slab for staircase steps including labour charges, hire chargers for tools and plants etc., |
| 41 | Supply and fixing of GI Hot Dip / powder coated 16 SWG Cable tray with 300mm width and 50mm height |
| 42 | SINGLE PHASE DISTRIBUTION BOARD WITH MCBS8 way/12 way vertical SPMCB sheetsteel dis- tribution boards flush type / surface type fitted with bus bars and neutral links with single phase MCB outgoings and separate 2 way provision for accommodating One No. 2 pole incoming MCB / Isolator and another separate 2 way provision for accommodating One No. 2 pole ELCB / RCD with label holder and provisions for taking up cable for size not less than 35 sq.mm. 8 ways single phase DBNo. of ways incomer MCB / Isolator 2 No. of ways incomer ELCB / RCD-2 No. of outgoings ways - 6 |
| 43 | EL-IN-EF-AC Plug - 25A) Supply and fixingof 25A Flush typeWall Socket 25A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) including cost of materials and labour charges etc., |
| 44 | AC-IN-SAC-T-S) SUPPLY & INSTALLATION OF AIR-CONDITIONER WITH COPPER COILAC-IN-SAC-1.5 T5 )1.5 TR Split Type AC Unit - 5 Star Rated |
| 45 | AC-IN-S-4KVA) Supply and installation of 4 KVA capacity Automatic Voltage Stabilizer with time delay relay |
| 46 | AC-IN-CP-5/8\\") Supply and laying of 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit) |
| 47 | AC-Ex-OD-MSS) Supply and fixing of MS stand for fixing outdoor unit. |
| 48 | Supply and fabrication of two wheeler shed truss work by using MS pipe 6\\" dia 3.4mm thick vertical post, Truss alround using MS square tube 70x70x3mm and 40x40x3mm for truss intermediate, horizondal purlins including cost of labour charges for erection, fixing, transportation and one coat of red oxide primer etc., |
| 49 | Supply and fixing of Pre-fabricated Structural Steel, coated Galvalume ROOFING SHEET of 0.5mm thickness with SMP coating with colour bond XRW coating, having minimum of 550 33 Mpa yield strength, Coating 150 GSM as per ASTM 792 or equivalent standard. The structural roofing Panel shall have 1020 mm effective width, nominal 30 mm crest height at nominal 250 mm centre to centre pitch with the embossment (share grove) on top & side of ribs for better composite action including Flashing for joints, and all incidental charges. |
| 50 | Premium quality PP (Polypropylene ) Bottle Trap with horizontal PVC Pipe length 5 inches and vertical PVC pipe length 11.5 inches, PVC wall Flange and Rubber washer & Nuts etc., |
| 51 | Charges for Divining bore hole point including transport labour etc complete. |
| 52 | Supplying and laying of Galvanised Concertina wire fencing with the Specifications of Concertina wire 450mm dia with the M.S angle of 25x25x5mm including labour charges for fixing angle, binding the barbed wire, transportation charges etc.. Please Enable Macros to View BoQ information |