| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.50M in width as well as 10 Sqm on plan) including disposal of excavated earth lead up to 50M and lift upto 1.50m and disposed earth to be levelled and neatly dressed : (a) All kind of soil |
| 2 | Dismantling RCC works including stacking of reclaimed MS reinforcement & disposal of unserviceable materials up to a distance of 50 M lead outside the periphery of area cleared |
| 3 | Dismantling AC Plain or corrugated / transparent sheets in roofing including ridges, hips, valleys and gutters etc. and stacking the material within 50 m lead |
| 4 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts,cutting rivets, welding etc. dismembering and stacking within 50 M lead |
| 5 | Dismantling CC works including disposal of unserviceable materials up to a distance of 50 M lead outside the periphery of area cleared |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.50m |
| 7 | Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m :All kinds of soil |
| 8 | Providing & laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering and reinforcement - all work upto plinth level RCC 1:2:4 (1 cement : 2 river sand : 4 stone aggregate 20 mm nominal size) |
| 9 | Providing & laying cement concrete 1:2:4 (1 cement : 2 river sand : 4 stone aggregate 20 mm nominal size) up to plinth level excluding the cost of centering and shuttering. |
| 10 | Centering and shuttering including strutting, propping etc and removal of form work for: (a) Foundation, footings, bases of columns etc. for mass concrete |
| 11 | Centering and shuttering including strutting, propping etc and removal of form work for: (b) Columns, piers, abutments, posts and struts |
| 12 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 13 | Reinforcement for RCC work including bending, binding and placing in position complete |
| 14 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes. |
| 15 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 16 | Half brick masonary with local best quality bricks in superstructures above plinth level upto floor five level in cement mortar 1: 4 (1 cement : 4 river sand). |
| 17 | Pucca brick work in foundation and plinth using common burnt clay local best quality bricks in cement mortar 1: 6 (1 cement : 6 river sand) including curing etc. complete . |
| 18 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 1:4 (1 cement : 4 coarse sand) |
| 19 | 12 mm cement plaster of mix 1 : 6 (1 cement : 6 river sand) at all height . |
| 20 | 15 mm cement plaster of mix (a) 1 : 6 (1 cement : 6 river sand) at all height |
| 21 | White washing with lime to give an even shade New work (three or more coats) : |
| 22 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 23 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 24 | Providing & fixing white vitreous china wash basin along including making all connections and the cost of fittings of following sizes (i) 550 x 400 mm |
| 25 | Providing and fixing PTMT stop cock of approved quality and colour 20 mm nominal bore, 89 mm long, weighing not less than 88 gms |
| 26 | Providing and fixing PTMT pillar cock of approved quality and colour.15 mm nominal bore, 107 mm long, weighing not less than 110 gms |
| 27 | Providing & fixing White vitreous china water closet squatting pan(Indian type) along with \\"S\\" or \\"P\\" trap including dismantling of oldWC seat and \\"S\\" or \\"P\\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern WC pan |
| 28 | Providing & fixing PVC waste of approved quality. |
| 29 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (external work) (b) 20 mm nomonal bore |
| 30 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall(c) 25 mm nominal bore |
| 31 | Applying priming coat with ready mixed red oxide Zinc chromate primer of approved brand & manufacture on steel galvanised iron / steel work |
| 32 | Painting with synthetic enamel paint of approved brand & manufacture in all shades to give an even & smooth shade including cleaning of surface :Old wood / steel works |
| 33 | Renewing approved quality glass panes with putty / wooden fillets and nails where ever necessary (b) 4mm thick @ 10 Kgs/ Sqm |
| 34 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 35 | Providing & fixing approved quality oxidised MS sliding door bolts with nuts & bolts etc. complete:(b) 300 x 16 mm |
| 36 | Providing and fixing approved quality MS bright finished handle with necessary screws etc. complete:(b) 100 mm |
| 37 | Providing and fixing approved quality MS pressed butt hinges bright finished with necessary screws etc. complete:(a) 125 x 65 x 2.12 mm |
| 38 | Providing and fixing ISI marked flush door shutters confirming to IS:2202 (Part-1), non decorative type , core or block board construction with frames of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands (ii) 30 mm thick |
| 39 | Providing & fixing plain AC sheet of approved quality with necessary screws / nails etc. complete at all height (frame work to be paid separately) (a) 4mm thick sheet |
| 40 | Providing & fixing wooden beading of size 50 x 12 mm of local hard wood in ceiling to support AC plain sheet at all height including nailing at 100 mm C/C as per the direction of Engineer - In- Charge. |
| 41 | Providing & fixing asbestos cement 6 mm thick corrugated sheets in roofing & side cladding and fixing with GI J or L hooks, bolts & nuts 8mm dia including GI plain & bitumen washers complete at all height excluding the cost of purlins, rafters, trusses (a) Height up to 5.00 M |
| 42 | Engagement of manpower for miscellenous civil work as per the direction of Engineer-In-Charge Please Enable Macros to View BoQ information |