| 1 | Repair, Rewinding & Servicing of various types of Pumps & motors |
| 2 | Providing and fixing of water seal suitable to 0.75 HP/1HP monoblock motor with necessary accessories etc as required. |
| 3 | Providing and fixing of Condensor for 1 Ph / Pump oil suitable to 0.75 HP/1 HP/ 1.5 HP monoblock motor with necessaryaccessories etc as required. |
| 4 | Rewinding of 01 HP submersible motor with all necessary materials. The motor is to be wound taking the no. of coil turns and pitch etc as reqd as it was originally wound with reqd. size of super enamelled copper wire with \\"E\\" class insulating materials, varnishing, greasing & testing as required i/c transportation from site & back (Including less cost of scap material) |
| 5 | Providing and fixing of ball bearing suitable to 1 HP monoblock motor with necessary accessories etc as required. |
| 6 | Rewinding of 1.5 HP monoblock / submersible motor with all necessary materials. The motor is to be wound taking the no. of coil turns and pitch etc as reqd as it was originally wound with reqd. size of super enamelled copper wire with \\"E\\" class insulating materials, varnishing, greasing & testing as required i/c transportation from site & back (Including less cost of scapmaterial) |
| 7 | Providing and fixing of water seal suitable to 1.5 HP monoblock / submersible motor with necessary accessoriesetc as required. |
| 8 | Providing and fixing of ball bearing suitable to 1.5 HPmonoblock / submersible motor with necessary accessories etc as required. |
| 9 | Rewinding of 03 HP monoblock motor with all necessary materials. The motor is to be wound taking the no. of coil turns and pitch etc as reqd as it was originally wound with reqd. size of super enamelled copper wire with \\"E\\" class insulating materials, varnishing, greasing & testing as required i/c transportation from site & back (Including less cost of scrapmaterial) |
| 10 | Providing and fixing of water seal suitable to 3 HP monoblock motor with necessary accessories etc as required. |
| 11 | Providing and fixing of ball bearing suitable to 3 HP monoblock motor with necessary accessories etc as required. |
| 12 | Rewinding of 05 HP Submersible motor with all necessary materials. The motor is to be wound taking the no. of coil turns and pitch etc as reqd as it was originally wound with reqd. size of super enamelled copper wire with \\"E\\" class insulating materials, varnishing, greasing & testing as required i/c transportation from site & back (Including less cost of scap material) |
| 13 | Providing and fixing of water seal suitable to 5 HPsubmersible motor with necessary accessories etc as required. |
| 14 | Providing and fixing of ball bearing suitable to 5 HPsubmersible motor with necessary accessories etc as required. |
| 15 | Providing and fixing of Oil seal suitable to 0.75/1/1.5 HPmonoblock / submersible motor with necessary accessories etc as required. |
| 16 | Providing and fixing of 'O' ring suitable to 0.75/1/1.5 HPmonoblock / submersible motor with necessary accessories etc as required. |
| 17 | Repair, Rewinding & Servicing of various types of fans (Rate including cost of extract item) |
| 18 | Rewinding of 1200/1400 mm Celling Fan by using 36 Gauge winding Wire, varnishing , heating reassembling etc as required as per specification of manufacturer (Including less cost of scrap material) |
| 19 | Providing and fixing of Celling Fan bearing 6201/6202 in the existing ceiling fan etc as required. |
| 20 | Providing and fixing of Celling Fan Capacitor(2.5 MFD, Keletron Make) etc as required |
| 21 | Providing and fixing of Celling Fan Fixing Clip/Clamp etc as required |
| 22 | Providing and fixing of Celling Fan Shaft etc as required |
| 23 | Rewinding of 250/300mm Exhaust Fan Using 38 Gauge Wire , varnishing , heating reassembling etc as required as per specification of manufacturer (Including less cost of scrap material) |
| 24 | Spray Painting of 1200/1400 mm Ceiling Fan including canopy, blades, down rod with Enamel Paint etc as required |
| 25 | Repair, Maintenance and AMC of Sewage Treatment Plant |
| 26 | Removal of sludge from Collection, Aeration, Settling and Filtered water tanks and disposing removed sludges etc as required as per direction of engineer in charge |
| 27 | Supply of micro organism- Bio culture for STP as per specifications |
| 28 | Supply of micro nutrients (Jaggery) as required |
| 29 | Repair Maintenance of Solar Water Heater |
| 30 | Servicing of 1500 Ltrs Solar Water Heating system by chemical washing of inner tubes of solar panels , cleaning of solar panel glasses, storage tank, pipe lines, checking of joints etc as required |
| 31 | Supply and Installation of neuoprint rubber insulation over hot water 32MM GI Pipe including removing rust, painting with synthetic enamel paint etc as required. (Need to Replace old Pipe) |
| 32 | Servicing, Maintenance & Testing of Transformers & Control Panels) |
| 33 | Servicing Charges for 500KVA Transformer including Silica gel replacement, filtration of transformer oil through stream line filter unit , Transformer testing and Issuing test certificates for Di- electric strength & acidity test of transformer oil etc as required. |
| 34 | OLTC servicing, Oil draining and filtration, moving and fixed contacts checking, on load tap changer drive mechanism, adjustment and issuing test certificates as required. |
| 35 | Insulation Resistance, Ratio Test , Winding Resistance, Magnetic Current, Magnetic balance testing of Kirloskar make 500KVA Transformer and Issuing test certificates as required. |
| 36 | Testing of RTCC panel and submission of test report as required. |
| 37 | Servicing and testing of Over current/Earth fault relay via secondary injection, TCS relay, Master trip & auxiliary relay testing of 11 KV HT panel of make ABB and submission of report as required. |
| 38 | Servicing of HT Vacuum Circuit breaker 11 KV, ABB make, Checking the condition of all components in Breaker and control, General servicing of cleaning and greasing of mechanical moving parts, checking of mechanical and electrical ON/OFF operation of breaker, checking of manual / motorized spring charging, Tripping / Closing lever alignment checking, Rack-in, Rack-out arrangement, etc |
| 39 | HT VCB ABB make 11KV Insulation resistance, contact resistance test, time interval test, CT/PT healthiness checking, Busbar tightness, Polarity Test, Winding Resistance and Winding Ratio test, etc and submission of test report as required. |
| 40 | 11 KV Double Pole Structure Maintenance & Painting work by carrying out AB switch alignment, general servicing, testing, operation/ healthiness checking of structure with insulators and painting of DP structure and fencing with one coat primer and two coats of synthetic enamel paint etc as required |
| 41 | Servicing and testing of ACB's of make L&T on LT side like Cleaning of breaker with agents, Re-greasing, Checking and fixing of Arcing contact gap between fixed and moving, Tripping of ACB through protection release, checking alignment of Pole assembly/Jaw contact/cradle terminals/SIC &scrap earthlings contact/front cover/push button, Check U/V release pickup/ACB tripping/spring charge motor/EDO ACB/continuity and proper changeover of Aux.contact/CTs, ACB in built release testing, etc as required. |
| 42 | Servicing and testing of MC61 relay on LT panel and submission of test report as required. |
| 43 | Servicing and testing of Capacitor bank healthiness for power factor correction and submitting test report as required. |
| 44 | Supply and Installation Of Indication Lamps in the existing panel board etc as required. |
| 45 | Supply and Installation of Over Current /Earth Fault Relay ABB make REJ601,5A,24-240 V AC/DC in the existing HT panel for 500 KVA Transformer protection etc as required. |
| 46 | Supply and Installation Of Ammeters With 125/5A, 100/5A, 120/5A, 200/5A With LT Tape Insulated CT-3 Nos with wiring replacement in the existing panel etc as required. |
| 47 | Supply and Installation Of Digital Ammeter (Ratio:500/5A) for existing Essential Panel-1 at Sub station |
| 48 | Supply and Installation Of Analog Voltmeter for existing Essential Panel-2 at Sub station |
| 49 | Supply and Installation Of Analog Ammeter (Ratio:200/5A) for existing Essential Panel-2 at Sub station |
| 50 | Supply and Installation Of Ammeter Selector Switch |
| 51 | Supply and Installation Of Voltmeter Selector Switch |
| 52 | Supply and Installation Of Digital Voltmeter |
| 53 | Supply and Installation of 200A, 3 Pole MCCB |
| 54 | Supply and Installation of 125A, 4 Pole MCCB |
| 55 | Supply of 4 KVA AC Stabilizer (V-Guard) |
| 56 | Supply and installation of of 5 KVA wall mounted AC Stabilizer 170 to 270 volts range(V-Guard/ micro tech) |
| 57 | Supply and installation of Geyser 25 Ltrs, 2000 watts, pressure 8 bar etc as required Please Enable Macros to View BoQ information |