| 1 | M&L for preparation of old treated mangalore pattern roof tile surface by cleaning the surfaces with jet washing and wire brushes to remove all existing fungal, growth etc. and applying one coats of antifungal paint using Asian or equivalent tile guard paint complete all as per manufactures instructions and all as specified and as directedNote:- The work shall be carried out on upto double storey slopping roof, chajja etc. and contractor is required to make necessary arrangements for water and electricity required for jet washing and rate quoted is deemeed to be included for above |
| 2 | Dismantling single layer of Mangalore pattern tiles in roofing all as specified and as directed |
| 3 | M&L, roof tiles Mangalore pattern interlocking at side joints, laid dry all as specified and as directed |
| 4 | Ditto- all as per Serial item No 3 here in before but except tiles all as specified and as directed |
| 5 | M&L, ridge or hip tiles to suit Mangalore pattern or roofing tiles bedded and jointed in cement mortar 1:6 using water proofing Compound. |
| 6 | Dismantling plain or corrugated steel sheeting / galvalume sheets, any gauge, thickness as in roof covering including aluminium frame all as specified and as directed |
| 7 | Dismantling wrought iron or mild steel of any description not otherwise provided for all as specified and as directed |
| 8 | S & F Anodised aluminium frame for roofing tiles with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed specified |
| 9 | S& F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws with bitumen washer all as specified and as directed |
| 10 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws with bitumen washer as specified. |
| 11 | S&F steel work in tubular trusses (tubular, angle, square and rectangular etc ) including erection shaped washer etc. complete using ERW or induction butt welded tubes. conforming to IS 1161-1998 grade St-240 for round tubes complete all as specified and as directed |
| 12 | Erection and fixing only steel work in tubular trusses (tubular, angle, square and rectangular etc ) including shaped washer etc. complete using ERW or induction butt welded tubes. conforming to IS 1161-1998 grade St-240 for round tubes complete all as specified and as directed |
| 13 | Taking down cement or cement lime plaster of any description including raking out joints, hacking for key and scrubbing down with water all as specified and directed. |
| 14 | M&L for preparation of untreated surfaces exc 10cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide zinc chrome on steel/iron surfaces all as specified and as directed |
| 15 | M&L for preparation of old painted surfaces exc 10cm width or girth and applying one coat of synthetic enamel paint on steel/iron surfaces all as specified and as directed |
| 16 | M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of epoxy paint all as specified and as directed |
| 17 | M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying two coat of epoxy paint over a coat of epoxy primer all as specified and as directed |
| 18 | M&L for rendering 15 mm thick CM 1:4 using liquid WPC liquid WPC over fair faces of brick work or concrete surfaces finished even and smooth ( In Patches) all as specified and directed . Note : WPC shall be measured and paid under separately |
| 19 | Removing Shrubs, Vegitation, roots etc.. from External wall surfaces , by dismantling Brick work , RCC or taking down plastering as the case may be, including dismantling SWR pipes, OH PVC service tanks etc. and refixing the same in original position and making good the surface dismantled all as specified and as directed . (Area to be dismantled exc 1 Sqm and no Exc 3 Sqm) |
| 20 | M&L for treating holes cracks etc. up to 10 mm by making V groove using patti blades and filling the cracks with cement and sand aggrgate mixture developed with polymer modified mortat (PMM) with suitable polymer like home shield crack fill paste home shield advance latex plus and home shield cement mix plus (berger make or equivalent) and allowed to dry complete all as specified and as directed |
| 21 | Material & Labour for applying Two coats of 100% Premium acrylic exterior emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal/algae resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, coverage @ 6 to 7 Sqm / ltr (two coats) over and including priming coat of exterior primer applied @ 11 Sqm/ltr (for one coat) including preparation of new plaster surface all as specified and as directed |
| 22 | Material & Labour for applying Two coats of 100% Premium acrylic exterior emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal/algae resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, coverage @ 6 to 7 Sqm / ltr (two coats) over and including priming coat of exterior primer applied @ 11 Sqm/ltr (for one coat) over old painted surfaces including complete removal of existing treatment/ preparation of existing surfaces as per site condition and cleaning the surfaces with bio wash to receive new treatment all as specified and as directed |
| 23 | M&L for preparation of old treated celling surfaces and applying one coat of white wash on ceiling all as specified and as directed |
| 24 | M&L for preparation of old treated celling surfaces and applying one coat of oil emulsion distemper all as specified and as directed |
| 25 | M&L for preparation of old decorated wall surfaces and applying one coat of oil bound distemper complete all as specified and as directed |
| 26 | M&L for preparation of old treated surfaces and applying one coat of acrylic emulsion paint having VOC content less then 50 gms/lters (interior grade) on wall all as specified and as per manufacture's instructions. |
| 27 | M&L for complete removal of existing treatment and applying two coats of acrylic emulsion paint (interior grade) on wall over a coat of acrylic primer over a coat of putty all as specified and as per manufacturer's instructions and as directed |
| 28 | M&L for preparation of old painted surfaces n.exc 10cm width or girth and applying one coat of synthetic enamel paint on steel/iron surfaces all as specified and as directed |
| 29 | M&L for preparation of old painted wooden surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed |
| 30 | Supply only water proofing compound (WPC) Please Enable Macros to View BoQ information |