| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 metres wide and not exceeding 1.5 metres deep for laying of drain pipes etc., for manholes and getting out in hard/dense soil complete all as specified and as directed |
| 2 | Excavation in post holes (or similar holes) each n. exc 0.5 cu.m, getting out, returning filling in and well ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm, watering and removing surplus soil to a distance n exc 50 m and making good surface in soft/loose soil complete all as specified and directed. |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 centimetres in each layer of the excavated soil complete all as specified and as directed |
| 4 | Removing the excavated material to a distance not exceeding 50 metres and deposited where directed at a level not exceeding 1.5 metres above the starting point complete all as specified and as directed |
| 5 | M&L PCC (1:4:8) type D2 (using 40mm aggregate stone aggregate) as in foundatons, filling and mass concrete complete all as specified and as directed. |
| 6 | M & L PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and directed. |
| 7 | M&L Providing PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating as directed chamfered necessary for work complete all as specified and directed. |
| 8 | M&L Providing precast RCC (1:2:4) type B1 (using 20mmgraded stone aggregate) as in pre cast posts,fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area but exc 100 and n exc 250 Sq cm, with or without chamfered angles and flat, splayed, rounded or mitred tops complete all as specified and as directed. |
| 9 | M & L Precast cement concrete block masonry with solid blocks exceeding 10cm in width by using precast cement concrete (1:3:6) type C1 (using 20 mm graded stone aggregate) and set in CM (1:6) complete all as specified and directed. |
| 10 | M&L 40 mm thick (measured solid),louvers and jallies with using precast cement concrete (1:2:4) type B0 (using 12.5 mm graded stone aggregate) including all mouldings set in CM (1:6) and complete all as specified and as directed. |
| 11 | Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles including removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 12 | M&L Brick work with using flyash bricks old size straight or curved on plan exceeding 6 m mean radius built in CM (1:6) complete all as specified and directed. |
| 13 | M & L Half brick work with using old size flyash bricks , straight or curved on plan exc 6.0 m mean raduis and built in CM (1:4) as in partition walls complete all as specified and directed. |
| 14 | M&L Cutting holes into or through brick/ stone walls built in cement mortar of superficial area n exc 150 Sq.cm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed |
| 15 | Taking down chowkats or frames with shutters (without taking off shutters from frames) of size not exceeding 1.5 Sqm each complete all as specified and as directed. |
| 16 | Taking down chowkats or frames with shutters (without taking off shutters from frames) of size exceeding 1.5 Sqm and not exc 4.00 sqm each complete all as specified and as directed. |
| 17 | M&L Cutting holes in brick wall built in cement mortor for inserting hold fast and making good the disturbed portion in cement mortor 1:3 depth of embeded portion exc half brick & N.exc one brick etc completed all as specified and directed by Engr-in-Charge. |
| 18 | S&F 125 x 60 mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc with one coat of primer complete all as specified and as directed |
| 19 | S & F 105 x 60mm pressed steel frame of size for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc with one coat of primer complete all as specified and as directed |
| 20 | M&L Providing PCC (1:2:4), type B1 (using 20 mm graded stone aggregate) as in filling back hollow portion of chowkats,etc complete all as specified and as directed. |
| 21 | S & F 40 mm thick flush shutters solid core construction with block board core and ply wood face panels, commercial type on both sides etc complete all as specified and directed. |
| 22 | S & F 30 mm thick factory made second class hardwood glazed /gauzed and skelton shutters, open rebated & prepared to recive glass/ gauged etc as in mosquito proof door shutter etc with out sash bars, edges of framing plain, chamfered or rounded,fitted with cut & mitred beads for securing glass, gauze etc, size of members of shutters as specified in SSR Part I section 8, clause 8.20 (a) and fixed to chowkats complete all as specified and directed. |
| 23 | S&F 200 mm long mild steel helical door ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed. |
| 24 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 25 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/sqmm, modulus of elasticity 850 N/sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 26 | S & F PVC solid ventilator frame size 55 X 47mm with wall thickness of 5mm made out of extruded 5mm PVC sheet, mitre cut at two comers and jointed with 2 Nos of 150mm long brackets of 15 x 15mm MS square tube the two vatted profiles are to be reinforced with 19 x 19mm MS squre tube the 50% of bottom portion is fixed with 4mm pin headed glass and balance 50% of top portion is fixed with 4mm thick pin headed glass lowers and cover with 0.36mm dia stainless steel wire mesh at top portion including necessary PVC beading with screws and 3 Nos 12mm dia MS guard, bars fixed in ventilator frame including two coats of synthetic enamel paint over a coat of red oxide primer to MS guard bars etc all as per specified and directed (Make SINTEX or epuivalent in RAJSHRI/NANDI make as approved by accepting officer) complete all as specified and as directed |
| 27 | S&F Steel windows (fly proof and glazed shutter) made with galvanised steel colour coated/ powder coated (Base steel as per IS 513 'D', galvanised as per IS 277 with zinc of 120gm/sqm) with total coating thickness of 0.60mm (outside for glazing and inside gauged shutter) Sections for frame should be of 72mmx55mm, section for mullian should be 72mm x 50mm section for shutter frame should be 47mmx 20mm and section for fixing glass bead should be 12mm x 12mm and section for fly mesh shutter frame should be 40mm x 20mm mesh fixing should be of 18mm x 0.6mm. Stainless steel wire mesh of 0.45mm dia and average width of aperture 1.4mm shall be used for fly proofing 4mm thick plain sheet glass to be used for glazing of glazed shutters complete all as specified and directed. |
| 28 | S&F 100 mm size mild steel butt hinges medium weight, cold rolled, mild steel complete all as specified and as directed. |
| 29 | S&F 100 mm size Butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type C-21 complete all as specified and as directed. |
| 30 | S&F 150 mm long aluminium anodised barrel tower bolt of extruded section with bright bolt complete all as specified and as directed |
| 31 | S&F 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed |
| 32 | S&F 150 mm size handles, extruded aluminium alloy fabricated type, anodised, complete all as specified and as directed. |
| 33 | S & F Mild steel sliding bolt 300 mm long plate type stove enameled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fix complete all as specified and as directed. |
| 34 | S&F in repairs 140 mm long double legged door stopper of aluminium anodized with rubber shoe, nut (2 each on one stopper) with spring complete all as directed complete all as specified and as directed. |
| 35 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets or frame work complete all as specified and directed. |
| 36 | S&F false ceiling at allheights with fully perforated 12mm thick micro tegular edged or 10mm thick square edged GRG false ceiling tiles of size 595 x 595 mm of approved texture design and patterns having moisture content less than 2% humidity resistance of 99% NRCO.50 to .75 as per IS 8225:1987, Noncobustible as per BS 476part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000m, cross-T of size 15 x 32 mm of length 1200 mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanized @ 80 grams per sqm) i.e, 50mm long , 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanized iron perimeter wall angle of size 24x 24x0.40mm of length 3000mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 37 | M&L Providing MS round bars up to 5 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for posts, including stituups,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips,complete all as specified and directed. |
| 38 | S&F Rolled mild steel sections of Fe 410-W (GDE E-250) QUALITY “A” frame work as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and as directed. |
| 39 | S&F Steel structure/ frame made of MS box/pipe sections ERW or induction butt weld tubes conforming to IS-1161-1979 grade St 240 as in column, purlins and truss complete fittings complete all as specified and directed. |
| 40 | S&F Wind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 etc complete all as specified and directed. |
| 41 | Dismantling timber Scantling framed work in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed. |
| 42 | Dismantling timber Scantling framed work 40 sqcm and over in section, in any position and removing store complete all as specified and as directed. |
| 43 | Dismantling of asbestos cement sheet /Plain or corrugated steel sheeting, (corrugated or semi corrugated) in roof covering complete all as specified and as directed. |
| 44 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as inroof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 45 | S&F Pre painted Galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 46 | Taking down of old bituminous tarfelt or any other type of roof treatment from roof/ concrete surfaces/cement morter 10mm rendering including removal of rubbish/ demolished materials out of MD land and including cleaning of the roof surface with wire brush to make it free from dust, dirt etc complete all as specified and as directed. |
| 47 | Demolition of cement concrete of any description and in any position not otherwise specifically provided in roof padding concrete etc including removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 48 | M&L Providing PCC (1:2:4) Type B0 (using 12.5 mm graded stone aggregate) with 2% by weight of cement or as per manufacturer's instructions water proofing as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc all as specified and directed. |
| 49 | M&L Rendering 10mm thick in CM (1:4) on top of roof surfaces duly mixing with water proofing compound at the rate of 3% by weight of cement and finished even and smooth complete all as specified and as directed.Note: Water proofing compound will be measured and paid separately under relevant item in this schedule |
| 50 | Supply only water proofing compound |
| 51 | M & L Providing water proofing treatment with APP based polymeric membrane minimum weighing 3 kg/ Sqm and minimum 3mm thick reinforced with polyester non oven fabric ( weight not less than 150gm/Sqm) applied on one coat of oil based bitumen emulsion primer @ 0.3 lit per sqm ( OR as per the directions of manufacturer instructions) including cleaning of surface thoroughly from dust, dirt and projections. Laying of membrane by forced ( torch) application with 10cm overlaps . A coat of blown bitumen 85/25 grade @ 1.2 Kg/sqm to be applied on top of membrane, finally coating the surface with bituminous aluminium paint @ 100gm/Sqm complete all as specified and as directed. |
| 52 | M&L Making the grooves to 'V' section in existing parapet walls/columns over RCC roofs, cleaning out and tacked the polymeric membrane in to the grooves and sealed solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc complete all as specified and directed. |
| 53 | Demolition of Cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 54 | Dismantling stone slabs and tiles of any description or thickness in floor, aprons laid bedded and pointed in any mortar including removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 55 | M&L 40 mm thick PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in flooring complete all as specified and directed. |
| 56 | M&L 75 mm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base to floor complete all as specified and as directed. |
| 57 | M&L 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in sub base to floor complete all as specified and as directed. |
| 58 | M&L 75 mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth sealed with sealing compound grade ‘A’ complete all as specified and directed. |
| 59 | M & L Vitrified Ceramic tiles 10 mm thick (Light shade of square/ rectangular) polished, area of each tiles size not exceeding 0.30 sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 10 mm thick CM (1:4) screed bed complete all as specified and as directed. |
| 60 | M & L Vitrified Ceramic tiles 10 mm thick (Light shade of square/ rectangular) polished, area of each tiles size not exceeding 0.30 sqm as in walls,skirting,dado,etc set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 10 mm thick CM (1:4) screed bed complete all as specified and as directed. |
| 61 | M&L Non skid coloured ceramic tiles 7 to 8 mm thick of size exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors,set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15 mm thick CM (1:6) screed bed complete all as specified and as directed. |
| 62 | M&L Non skid coloured ceramic tiles 7 to 8 mm thick of size exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors,set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15 mm thick CM (1:6) screed bed complete all as specified and as directed. |
| 63 | M&L Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15 mm thick CM (1:6) screed bed complete all as specified and as directed. |
| 64 | M&L LEAD free ceramic tiles/radiation shielding tiles size 600 mmx600mm,7 to 8 mm thick as in floors,set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 20 mm thick CM (1:6) screed bed complete all as specified and as directed. |
| 65 | M&L LEAD free ceramic tiles/radiation shielding tiles size 450 mmx300mm,7 to 8 mm thick as in walls,dado,set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 10 mm thick CM (1:4) backing coat complete all as specified and as directed. |
| 66 | M&L Glazed ceramic coloured wall tiles of approved colour of size 300 mm x 450 mm x 8 to 9 mm / 450 mm x350 mm x 8 to 9 mm thick on vertical surfaces as in dado/wall set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 10 mm thick CM (1:4) backing coat complete all as specified and as directed |
| 67 | M&L Endura heavy duty tiles of size 300 mm x300 mm x10 mm thick as in floors,set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15 mm thick CM (1:6) screed bed complete all as specified and as directed. |
| 68 | M&L 18 to 20 mm thick Machine cut granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like laid over & including 10mm thick bedding /backing coat in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of slab complete all as specified and as directed. |
| 69 | M&L Providing 60 mm thickness, M-35 Grade, machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of with grey cement and pigment complete all as specified and directed. |
| 70 | M&L Sand/ grit cushioning below interlocking tiles including spreading and levelling complete all as specified and as directed. |
| 71 | M&L Rendering 15 mm thick in CM (1:6) on brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and as directed. |
| 72 | M&L Rendering 15 mm thick CM (1:4) on fair faces of brick work or stone masonary surfaces and finished the surface smooth and even without using extra cement complete all as specified and as directed |
| 73 | M&L Rendering 12 mm thick CM (1:4) on fair faces of brick work or concrete surfaces without using extra cement complete all as specified and as directed |
| 74 | M & L Rendering 5 mm thick in CM (1:3) on concrete surfaces of ceiling finished even and smooth without using extra cement in patches n exc 3 sqm each patch all as specified and as specified. |
| 75 | M & L Preparing newly plastered wall surfaces and applying three coats of white wash complete all as specified and as directed. |
| 76 | M & L Preparing newly plastered wall surfaces and applying two coats of white wash complete all as specified and as directed. |
| 77 | M&L Preparation of newly plastered ceiling surfaces and applying three coats of white wash on celings complete all as specified and as directed |
| 78 | M & L Preparing newly plasterd wall surfaces of walls and applying two coats of Acrylic distemper over and including a coat of primer using chalk whiting over and including 3 mm thick wall care putty in two layers complete all as specified and as directed. |
| 79 | M&L Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified and as directed |
| 80 | M&L Preparation of new surfaces of steel, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 81 | Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20 mm complete all as specified and directed. |
| 82 | Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 25 mm complete all as specified and directed. |
| 83 | Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 40 mm complete all as specified and directed. |
| 84 | Cutting and grooving of wall for fixing of CPVC pipe lines and after fixing of CPVC pipe line and making good of all cutting surfaces etc complete all as specified and as directed. |
| 85 | S&F CPVC pipes, SDR 11, 20 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets , male and femaleThreaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed. |
| 86 | S&F Water closet (pedestal pattern) coloured with combined flush tank (Cascade type) with Lid, seat cover, cistern fittings and all accessories complete all as specified and as directed MAKE: CAT No 92072 of HINDWARE (S-10/P-18) Pastel colour or equivalent model in PARRYWARE/CERA as approved |
| 87 | S&F CP brass 32 mm bottle trap for wash basins / urinals with inlet and outlet screwed for pipe connections including necessary packing , union and cap and fixed complete all as directed. Make :Jaguar, Code ALD 769 |
| 88 | S&F Toilet paper holder with flap, brass chromium plated, fixed to walls with chromium plated brass screws complete all as specified and as directed.Make: CAT No F880003 or HINDWARE or equivalent model in PARRYWARE/CERA as approved |
| 89 | S&F 15mm dia brass chromium plated Two way Bib tap with wall flange type, fancy type, and high pressure, with flange screwed, and screwed both ends for iron pipe or for unions complete all as specified and as directed.MAKE: CAT No F200004FT of HINDWARE or equivalent model in PARRYWARE/CERA as approved |
| 90 | S&F 15mm dia brass chromium plated Bib tap with wall flange type, fancy type, and high pressure, with flange screwed, and screwed both ends for iron pipe or for unions complete all as specified and as directed.MAKE: CAT No F200004FT of HINDWARE or equivalent model in PARRY WARE/CERA as approved |
| 91 | S&F Brass chromium plated concealed stop cock,regular body with adjustable wall flange screwed down, high pressure, with crutch handle, screwed both ends for 15mm dia bore iron pipe or for unions complete all as specified and as directed. MAKE: CAT No F200005FT of HINDWARE or equivalent model in JAQUAR/ PARRYWARE/CERA as approved |
| 92 | S&F 15 mm bore brass chromium plated Pillar cock long neck with aerator,high pressure with crutch handle, screwed down, and screwed for iron pipe or for unions complete all as specified and as directedMAKE: CAT No F330002CP of HINDWARE or equivalent model in JAQUAR/ PARRYWARE/CERA as approved |
| 93 | S&F in repairs of 15 mm bore stop cock, brass chromium plated angle cock with wall flange type, fancy type, and high pressure, with flange screwed, and screwed both ends for iron pipe or for unions complete all as specified and as directed.MAKE: CAT No F200005FT of HINDWARE or equivalent model in PARRYWARE/CERA as approved |
| 94 | S&F in repairs of 15 mm brass chromium plated concealed stop cock regular body with adjustable wall flange, screwed, and screwed both ends for iron pipe or for unions complete all as specified and as directed.MAKE: CAT No F200007FT of HINDWARE or equivalent model in JAQUAR/ PARRYWARE/CERA as approved |
| 95 | S&F Soap dish brass complete all as specified and as directedMake: CAT No F880011 of HINDWARE or equivalent model in PARRYWARE/ CERA as approved. |
| 96 | S&F Brass chromium plated towel rack 600 mm long with lower hangers, brass screws and wooden/plastic cleats complete all as specified and as directed.Make: CAT No F840010 or HINDWARE or equivalent in PARRYWARE/ CERA as approved |
| 97 | M&L Cutting of granite slab for fixing of under counter wash basin including rounded and grinding the stone with necessary arrangments complete all as specified and as directed |
| 98 | S&F Wash down water closet (pedestal pattern) white and including plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device (excluding flushing cistern ) etc complete all as specified and directed. |
| 99 | S&F Vitreous china wash basin, white, flat back, size 580mm X 450mm including CI brackets, 32mm dia brass chromium plated waste fittings with long screwed shanks and fly nuts flanged end bedded in red lead cement and other end fixed with & including cutting for & pinning in end of brackets and 15mm bore pillar tap, cast copper alloy fancy type chromium plated, screwed down high pressure including waste pipe complete all as specified and as directed. |
| 100 | S & F 10 litres capacity PVC low level flushing cistern including brackets complete, fixed all as directed and as specified complete all as speciified and as directed. |
| 101 | S&F Vitreous China counter top wash basin of size 600 x 450 x 190 mm with 32mm dia brass chromium plated waste coupling and cast iron brackets complete all as specified and as directed.MAKE: CAT No Jaquar Code- QNS-WHT-7601AT No 10051 or equivalent model in HINDWARE PARRYWARE/CERA as approved |
| 102 | S&F 600 X 450mm bevelled edge mirror, 5mm thick selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed with wooden plugs to wall with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 103 | S&F 40 mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed to wall ceiling or in floors etc. complete all as specified and as directed |
| 104 | S&F CP corner glass 12mm thick with brass bracket screws etc complete all as specified and directed. |
| 105 | S&F 15mm size PVC connection with PTMT nuts 600mm length.complete all as specified and directed. |
| 106 | S&F Rotational moulded polyethylene water storage tank 3 layer white colour waterr tank , non- toxic effect, algea formation protection (made from Virgin grade of polyetjylene material which is duly stablized with anti-oxidentPlastic) of capacity 1000 litres, (cylindrical vertical one piece moulded with closed top), the internal and external surfaces of tanks are smooth, clean and free from any hidden internal defects, hoisted and fixed in position including S & F necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer, 20mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 210gms) complete including dismantling existing water tank all as specified and directed. Make: Cat No. HSWS-0100-01-Pure of M/s Sintex |
| 107 | S&F Ball valve of size 15mm dia high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed. |
| 108 | Dismantling / taking down PVC/ Cast iron soil /waste pipes 100 mm / 75mm bore including all fitting like bends etc complete all as specified and directed |
| 109 | S&F PVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4) & including removing old trap and fixing of stainless steel grating in ground shape etc complete all as specified and as directed. |
| 110 | S&F 110 mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed. |
| 111 | S&F 75 mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed. |
| 112 | S&F 110mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed. |
| 113 | S&F 110 mm bore PVC (SWR) junction single (single T ) equal or unequal with access doors etc, complete all as specified and as directed. |
| 114 | S&F for 110 mm bore PVC (SWR) vent cowl etc, complete all as specified and as directed. |
| 115 | S&F 20mm gun meteal,globe or gate valves, with iron wheel head screwed both ends for iron pipe and fixed complete all as directed. |
| 116 | M&L On site LLDPE septic tank designed to carry sewage and sullage water capacity 30 users capacity , including excavation in any type of soil, PCC 1:4:8 below foundation, with up flow filter incuding media,vent shaft connections etc, complete all as directed by Eng-in-charge. |
| 117 | M&L Construction of Soakage wells excavation, inany type of soil, foundation in PCC (1:3:6) type D2 (using 40 mm graded stone aggregate) with walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4m dia x 3.0 m effective depth as per drawing No.TD/ST/747, sheet No 1/1 dt 22 Jan 2011 complete all as directed by Eng-in-charge. |
| 118 | M&L DWPE (SN8) 180 (OD)/ 163 (ID) mm diameter pipes of length 0.70 to 1.65 m laid on 150 mm thick bed including excavation in any type of soil, including manholes/ drop manhole of standard size made of brick masonry/ RCC/ Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional complete all as directed by Eng-in-charge. |
| 119 | M&L Providing point wiring on concealed conduit with 1.5 Sq mm FRLS copper conductor single core PVC insulated sheathed 1100 V multistranded drawn through including rigid PVC conduit of dia medium grade and modular accessories including fixing/grouting sunken/ surface along with modular flush box of sutiable thickness covered with suitable modular cover plate including running up of 1.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc for one light/fan controlled by one, one way switch 6A, SP, complete all as specified and directed. Note: Rate of Modular Flush box and Cover plate are inclusive of rate quoted by the contractor |
| 120 | All as per Item No.119 above, but one 3 Pin 5 Amps switch socket outlet point controlled by one switch on Independt board. |
| 121 | All as per Item No.119 above, but one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 122 | S & F Modular switch 1 way, 10 A, 1 Module capacity 230 volts complete all as specified and directed. |
| 123 | S&F Modular socket outlet multipurpose 2/3 Pin, 6 amps, 230 volts combined 2 Module complete all as specified and directed. |
| 124 | S & F Ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and as directed. |
| 125 | S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 126 | S&F Round shape 12 watt 220 volts AC surface mounted type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 127 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 128 | S &F Sheet metal enclosure MCB DB SPN 4 way with suitable rated bus bar 240 Volts double door with magnetic locking system complete all as specified and as directed. |
| 129 | S&F MCB, SP 6-32 Amps, 240 volts of rupturing capacity 10 KA, 'C' series complete all as specified and as directed. |
| 130 | S&F MCB, SPN 32 Amps, 240 volts of rupturing capacity 10 KA, 'C' series complete all as specified and as directed. |
| 131 | S&F PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circular 10 Sqmm,1100 volts grade heavy duty cable suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, complete all as specified and as directed. |
| 132 | S & F Exhaust fan made of sturdy engineering plastic of 250 mm sweep 1200 RPM, voltage 230v, 50Hz, copper winding,complete with louvers shutter, including provision for fixing complete all as specified and directed. |
| 133 | M&L Earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed.NOTE: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |