| Sl. No. | Item Description |
| 1 | Civil work Boundary Wall 20` |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 4 | CEMENT PLASTER (IN COARSE SAND) 12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) HSR 11.8 |
| 5 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 6 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor four level, excluding the cost of centering, shuttering and finishing: 1. 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). HSR 6.2 |
| 7 | E READY MIX CEMENT CONCRETE Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2.3. All works up to Plinth Level :M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) HSR 6.22 |
| 8 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24 |
| 9 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24 |
| 10 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR 6.30 |
| 11 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. HSR 6.30 |
| 12 | N EXPANSION JOINTS Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminium base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings and complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminium profiles exhibiting minimal exposed aluminium surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 1. Wall Joint of 100 mm gap HSR 6.62 |
| 13 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 14 | Boundary Wall 16` |
| 15 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 16 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 17 | CEMENT PLASTER (IN COARSE SAND) 12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) HSR 11.8 |
| 18 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 19 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor four level, excluding the cost of centering, shuttering and finishing: 1. 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). HSR 6.2 |
| 20 | E READY MIX CEMENT CONCRETE Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2.3. All works up to Plinth Level :M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) HSR 6.22 |
| 21 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24 |
| 22 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24 |
| 23 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR 6.30 |
| 24 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. HSR 6.30 |
| 25 | N EXPANSION JOINTS Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminium base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings and complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminium profiles exhibiting minimal exposed aluminium surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 1. Wall Joint of 100 mm gap HSR 6.62 |
| 26 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 27 | Construction of Watch Tower (7 nos.) |
| 28 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. HSR 4.1 |
| 29 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 30 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter HSR 9.57 |
| 31 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5°150 mm bend HSR 9.58 |
| 32 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 33 | Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% HSR 4.39 |
| 34 | CEMENT CONCRETE FLOORING Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. HSR 10.1 |
| 35 | CEMENT CONCRETE FLOORING Providing and laying of screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. HSR 10.4 |
| 36 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR 11.4 |
| 37 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR 11.6 |
| 38 | CEMENT PLASTER (IN COARSE SAND) 12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) HSR 11.8 |
| 39 | KOTA STONE FLOORING Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick HSR 10.37 |
| 40 | KOTA STONE FLOORING Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. HSR 10.38 |
| 41 | POINTING ON BRICK WORK Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): 1. Flush / Ruled/ Struck or weathered pointing HSR 11.25 |
| 42 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing hard drawn steel wire fabric 75 mm X 25 mm rectangular mesh with 3.25 mm dia wire fixed on steel windows of standard rolled sections with 3 mm thick flat iron cover moulding of 12.5 mm width fixed with machine screws welded complete in all respect. HSR 13.18 |
| 43 | CERAMIC GLAZED TILES Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. HSR 10.57 |
| 44 | INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.60 |
| 45 | INTERIOR FINISHING Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer HSR 11.64 |
| 46 | INTERIOR FINISHING Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works HSR 11.68 |
| 47 | INTERIOR FINISHING Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre HSR 11.69 |
| 48 | INTERIOR FINISHING Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats HSR 11.75 |
| 49 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 |
| 50 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 51 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 1. New work (Two or more coats applied @ 1.43 litre/ 10 sqm Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm HSR 11.98 |
| 52 | WINDOW GRILLS, METAL MESH, WIRE GAUGE ETC. Providing and fixing M.S. grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 1. Fixed to steel windows by welding HSR 12.50 |
| 53 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. HSR 28.16 |
| 54 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 withC.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: 1.2. Kitchen sink with drain board 510x1040 mm bowl depth 225 mm HSR 22.10 |
| 55 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 1.1. Semi rigid pipe32 mm dia HSR 22.14 |
| 56 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1. White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests HSR 22.22 |
| 57 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 1. Single half stall urinal with 5 litre P.V.C. automatic flushing cistern HSR 22.26 |
| 58 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 4. Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern HSR 22.26 |
| 59 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement mortar 1:6 (1 cement : 6 coarse sand) HSR 7.21 |
| 60 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.22 |
| 61 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.85 |
| 62 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR 22.86 |
| 63 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 6. 50 mm nominal outer dia Pipes HSR 22.87 |
| 64 | BRASS FITTINGS Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore HSR 22.101 |
| 65 | C.P. BRASS FITTINGS Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore HSR 22.105 |
| 66 | C.P. BRASS FITTINGS Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore HSR 22.108 |
| 67 | LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181 |
| 68 | M Masonry Chambers Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR 21.84 |
| 69 | M Masonry Chambers Extra for every 0.30 metre depth of Inspection chamber 3. 600 mm x 900 mm inside HSR 21.85 |
| 70 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 71 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 72 | D REINFORCED CEMENT CONCRETE Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) HSR 6.14 |
| 73 | D REINFORCED CEMENT CONCRETE Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) HSR 6.15 |
| 74 | D REINFORCED CEMENT CONCRETE Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). HSR 6.16 |
| 75 | D REINFORCED CEMENT CONCRETE Reinforced cement concrete work in arches, arch ribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). HSR 6.18 |
| 76 | D REINFORCED CEMENT CONCRETE Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size). HSR 6.21 |
| 77 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24 |
| 78 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24 |
| 79 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR 6.30.1 |
| 80 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. HSR 6.30.2 |
| 81 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR 6.30.3 |
| 82 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR 6.30.5 |
| 83 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts HSR 6.30.6 |
| 84 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 8. Spiral staircases (including landing) HSR 6.30.8 |
| 85 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 14. Extra for shuttering in circular work (20% of respective centering and shuttering items) HSR 6.30.14 |
| 86 | I CENTRING AND SHUTTERING (FORM WORK) Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1. Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) HSR 6.32 |
| 87 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more HSR 6.33 |
| 88 | Male Barrack Type- I (3 nos.) |
| 89 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. HSR 4.1 |
| 90 | B ROOFING 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10 HSR 9.11 |
| 91 | B ROOFING Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase HSR 9.17 |
| 92 | B ROOFING Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. HSR 9.18 |
| 93 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 94 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter HSR 9.57 |
| 95 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.1. Coupler 75 mm HSR 9.58 |
| 96 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 2.3. Single push fit Coupler 150 mm HSR 9.58 |
| 97 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5°110 mm bend HSR 9.58 |
| 98 | RAIN WATER SPOUTS AND PIPES Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. HSR 9.60 |
| 99 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 100 | Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% HSR 4.39 |
| 101 | CEMENT CONCRETE FLOORING Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. HSR 10.1 |
| 102 | C FIXING INCLUDING CARRIAGE Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge HSR 21.28 |
| 103 | CEMENT CONCRETE FLOORING Providing and laying of Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling. HSR 10.9 |
| 104 | CEMENT CONCRETE FLOORING Providing and laying cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 1. 18 mm thick HSR 10.13 |
| 105 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR 11.4 |
| 106 | TERRAZO FLOORING Providing and laying of marble chips skirting up to 30 cm height, rubbed and polished to granolithic finish, top layer 6 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from smallest to 4 mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume : 1.1. 18 mm thick with under layer 12 mm thick in cement plaster 1:3 (1 cement : 3 coarse sand) :Dark shade pigment with ordinary cement HSR 10.25 |
| 107 | G STONE WARE INTERCEPTING TRAPS, FLAP VALVES, ROAD GULLIES ETC. Fixing cast iron road gully grating and frame complete including carriage from the stores of the Engineer-in-charge of the works, loading, fixing and erecting the same in position to correct lines and levels in 1:2 cement sand mortar and painting of grating and frame with coal tar. HSR 21.48 |
| 108 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) HSR 11.6 |
| 109 | TILE FLOORING Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 2. Medium shade pigment using 50% white cement, 50% ordinary cement HSR 10.29 |
| 110 | CEMENT PLASTER (IN COARSE SAND) 12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) HSR 11.8 |
| 111 | CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge HSR 11.17 |
| 112 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 1. Using M.S. angels 40x40x6 mm for diagonal braces HSR 13.6 |
| 113 | KOTA STONE FLOORING Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick HSR 10.37 |
| 114 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3 mm and nuts and bolts complete. 2. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides HSR 13.9 |
| 115 | KOTA STONE FLOORING Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. HSR 10.38 |
| 116 | MARBLE STONE FLOORING Providing and laying Baroda Green marble stone 17mm and above thick in risers of step, skirting , dado, pillars and wall lining included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR 10.47 |
| 117 | MARBLE STONE FLOORING Providing and laying Baroda Green marble stone 17mm and above thick flooring included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR 10.48 |
| 118 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing hard drawn steel wire fabric 75 mm X 25 mm rectangular mesh with 3.25 mm dia wire fixed on steel windows of standard rolled sections with 3 mm thick flat iron cover moulding of 12.5 mm width fixed with machine screws welded complete in all respect. HSR 13.18 |
| 119 | GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. HSR 10.50 |
| 120 | PRE-PAINTED / POWDER COATED GALVANISED SHEET DOOR/WINDOW FRAMES AND WINDOW SHUTTERS Supply and fixingWindows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm and Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 1. Door Frame of size 80mm x 50mm with 37mm wide single rebate for 35mm door shutter HSR 13.21 |
| 121 | CERAMIC GLAZED TILES Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. HSR 10.62 |
| 122 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR 13.29 |
| 123 | RENDERING ON RCC SURFACE Smooth finishing of the exposed surface of R.C.C. work with 10 mm thick cement mortar 1:4 (1 Cement : 4 fine sand). HSR 11.51 |
| 124 | INTERIOR FINISHING Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete HSR 11.58 |
| 125 | INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.60 |
| 126 | INTERIOR FINISHING Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre HSR 11.69 |
| 127 | INTERIOR FINISHING Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats HSR 11.75 |
| 128 | INTERIOR FINISHING Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR 11.76 |
| 129 | INTERIOR FINISHING Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. HSR 11.77 |
| 130 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 |
| 131 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 132 | FLUSH DOOR SHUTTERS Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws HSR 12.37 |
| 133 | STAINLESS STEEL FITTINGS Providing and fixing bright /matt finished Stainless Steel handles of approved quality and make with necessary screws etc all complete. 1. 125 mm HSR 12.75 |
| 134 | HYDRAULIC DOOR CLOSERS Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. HSR 12.89 |
| 135 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm HSR 12.98 |
| 136 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 250x10 mm HSR 12.99 |
| 137 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 200x10 mm HSR 12.99 |
| 138 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. HSR 28.16 |
| 139 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2. Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests HSR 22.22 |
| 140 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing partitions for different type of urinals. 1.1.1. Vitreous Chinaware Partition plate.Small size 680mm x 330 mm White HSR 22.50 |
| 141 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.21 |
| 142 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.22 |
| 143 | HALF BRICK MASONRY Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) HSR 7.28 |
| 144 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.85 |
| 145 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes HSR 22.85 |
| 146 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia Pipes HSR 22.86 |
| 147 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR 22.86 |
| 148 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.86 |
| 149 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes HSR 22.86 |
| 150 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 1. 15 mm nominal outer dia Pipes HSR 22.87 |
| 151 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 3. 25 mm nominal outer dia Pipes HSR 22.87 |
| 152 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 4. 32 mm nominal outer dia Pipes HSR 22.87 |
| 153 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 5. 40 mm nominal outer dia Pipes HSR 22.87 |
| 154 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore HSR 22.98 |
| 155 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore HSR 22.98 |
| 156 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. HSR 22.98 |
| 157 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore HSR 22.98 |
| 158 | BRASS FITTINGS Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore HSR 22.101 |
| 159 | BRASS FITTINGS Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore HSR 22.103 |
| 160 | C.P. BRASS FITTINGS Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore HSR 22.104 |
| 161 | C.P. BRASS FITTINGS Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore HSR 22.105 |
| 162 | C.P. BRASS FITTINGS Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore HSR 22.106 |
| 163 | C.P. BRASS FITTINGS Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore HSR 22.107 |
| 164 | C.P. BRASS FITTINGS Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore HSR 22.108 |
| 165 | C.P. BRASS FITTINGS Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. HSR 22.109 |
| 166 | STONE WARE PIPES AND FITTINGS Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 3.1. 180x150 mm size P typeWith common burnt clay non-modular bricks of class designation 7.5 HSR 22.166 |
| 167 | LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181 |
| 168 | M Masonry Chambers Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR 21.84 |
| 169 | N MANHOLE CHAMBERS Construction of rectangular standard brick masonry manhole chambers to standard drawings on S.W. pipe sewers or other circular pipe sewers up to the required depth in 1.5 cement sand mortar, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium silicate on interior surface where required, reinforced cement concrete slab 180mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. the rate covers the cost of M.S. steel for R.C.C. slab labour for fixing and carriage of C.I. manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also include the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. sodium silicate shall be supplied free of cost at the stores of the Engineer-in-charge. 2.1. On 150 mm internal diameter pipe sewer - for 1.20 meters depth below ground level HSR 21.90 |
| 170 | N MANHOLE CHAMBERS Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening HSR 21.93 |
| 171 | HDPE pipes for Drainage Providing and Supplying of class SN 8 structured wall Polyethylene Piping system (Pipe with online/ offline coupler and elastomeric sealing ring) with non smooth external annular corrugated and smooth internal surface (double wall) for non-pressure underground sewerage and drainage application as confirm to IS 16098 (part II):2013 including transportation, frieght charges, inspection charges, loading, unloading, complete as specified and directed by Engineer In-Charge. 1. 250 mm Internal Diameter HSR 22.218 |
| 172 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 173 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 174 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.4. Single Socket Type B 75mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 175 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 176 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24 |
| 177 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24 |
| 178 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR 6.30.1 |
| 179 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. HSR 6.30.2 |
| 180 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR 6.30.3 |
| 181 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) HSR 6.30.4 |
| 182 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR 6.30.5 |
| 183 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts HSR 6.30.6 |
| 184 | I CENTRING AND SHUTTERING (FORM WORK) Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1. Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) HSR 6.32 |
| 185 | Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. HSR 4.16 |
| 186 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 187 | Female Barrack |
| 188 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. HSR 4.1 |
| 189 | B ROOFING 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10 HSR 9.11 |
| 190 | B ROOFING Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase HSR 9.17 |
| 191 | B ROOFING Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. HSR 9.18 |
| 192 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 193 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter HSR 9.57 |
| 194 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.1. Coupler 75 mm HSR 9.58 |
| 195 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 2.3. Single push fit Coupler 150 mm HSR 9.58 |
| 196 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5°110 mm bend HSR 9.58 |
| 197 | RAIN WATER SPOUTS AND PIPES Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. HSR 9.60 |
| 198 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shadeArea of slab over 0.50 sqm HSR 8.26 |
| 199 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 200 | Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% HSR 4.39 |
| 201 | CEMENT CONCRETE FLOORING Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. HSR 10.1 |
| 202 | C FIXING INCLUDING CARRIAGE Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge HSR 21.28 |
| 203 | CEMENT CONCRETE FLOORING Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4 HSR 10.7 |
| 204 | CEMENT CONCRETE FLOORING Providing and laying of Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling. HSR 10.9 |
| 205 | CEMENT CONCRETE FLOORING Providing and laying cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 1. 18 mm thick HSR 10.13 |
| 206 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR 11.4 |
| 207 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb HSR 13.3 |
| 208 | G STONE WARE INTERCEPTING TRAPS, FLAP VALVES, ROAD GULLIES ETC. Fixing cast iron road gully grating and frame complete including carriage from the stores of the Engineer-in-charge of the works, loading, fixing and erecting the same in position to correct lines and levels in 1:2 cement sand mortar and painting of grating and frame with coal tar. HSR 21.48 |
| 209 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR 11.6 |
| 210 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) HSR 11.6 |
| 211 | TILE FLOORING Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 2. Medium shade pigment using 50% white cement, 50% ordinary cement HSR 10.29 |
| 212 | CEMENT PLASTER (IN COARSE SAND) 12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) HSR 11.8 |
| 213 | CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge HSR 11.17 |
| 214 | KOTA STONE FLOORING Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick HSR 10.37 |
| 215 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3 mm and nuts and bolts complete. 2. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides HSR 13.9 |
| 216 | MARBLE STONE FLOORING Providing and laying Baroda Green marble stone 17mm and above thick in risers of step, skirting , dado, pillars and wall lining included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR 10.47 |
| 217 | MARBLE STONE FLOORING Providing and laying Baroda Green marble stone 17mm and above thick flooring included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR 10.48 |
| 218 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing hard drawn steel wire fabric 75 mm X 25 mm rectangular mesh with 3.25 mm dia wire fixed on steel windows of standard rolled sections with 3 mm thick flat iron cover moulding of 12.5 mm width fixed with machine screws welded complete in all respect. HSR 13.18 |
| 219 | GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. HSR 10.50 |
| 220 | CERAMIC GLAZED TILES Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. HSR 10.62 |
| 221 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR 13.29 |
| 222 | ROLLING/COLLAPSIBLE/SLIDING DOOR SHUTTERS Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 1. 80x1.25 mm M.S. laths with 1.25 mm thick top cover HSR 13.37 |
| 223 | ROLLING/COLLAPSIBLE/SLIDING DOOR SHUTTERS Providing and fixing ball bearing for rolling shutters. HSR 13.38 |
| 224 | ROLLING/COLLAPSIBLE/SLIDING DOOR SHUTTERS Extra for providing mechanical device chain and crank operation for operating rolling shutters. 1. Exceeding 10.00 sqm and up to 16.80 sqm in the area HSR 13.39 |
| 225 | RENDERING ON RCC SURFACE Smooth finishing of the exposed surface of R.C.C. work with 10 mm thick cement mortar 1:4 (1 Cement : 4 fine sand). HSR 11.51 |
| 226 | PVC/LINOLEUM FLOORING Providing and fixing of P.V.C. sheet flexible type conforming to I.S.3462-1966 flooring plain coloured marble or mottled finish on a smooth damp proof base laid with adhesive recommended by manufacturer including pressing the sheet with a suitable tool to get a smooth surface all complete as directed by the Engineer-in-Charge. 2. 2.00 mm thick HSR 10.82 |
| 227 | INTERIOR FINISHING Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete HSR 11.58 |
| 228 | INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.60 |
| 229 | INTERIOR FINISHING Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works HSR 11.68 |
| 230 | INTERIOR FINISHING Applying priming coat: 4. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) HSR 11.68 |
| 231 | INTERIOR FINISHING Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre HSR 11.69 |
| 232 | INTERIOR FINISHING Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats HSR 11.75 |
| 233 | INTERIOR FINISHING Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR 11.76 |
| 234 | INTERIOR FINISHING Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. HSR 11.77 |
| 235 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 |
| 236 | INTERIOR FINISHING Painting the wooden / metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work HSR 11.82 |
| 237 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 238 | FLUSH DOOR SHUTTERS Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws HSR 12.37 |
| 239 | STAINLESS STEEL FITTINGS Providing and fixing bright /matt finished Stainless Steel handles of approved quality and make with necessary screws etc all complete. 1. 125 mm HSR 12.75 |
| 240 | HYDRAULIC DOOR CLOSERS Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. HSR 12.89 |
| 241 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm HSR 12.98 |
| 242 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 250x10 mm HSR 12.99 |
| 243 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 200x10 mm HSR 12.99 |
| 244 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-1. White vitreous chinaware Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer HSR 22.2 |
| 245 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing white vitreous chinaware pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. HSR 22.5 |
| 246 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. HSR 28.16 |
| 247 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 withC.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: 2.1. Kitchen sink without drain board 610x510 mm bowl depth 200 mm HSR 22.10 |
| 248 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2. Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests HSR 22.22 |
| 249 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. HSR 22.33 |
| 250 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. HSR 22.38 |
| 251 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing toilet paper holder : 1. C.P. brass HSR 22.42 |
| 252 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.21 |
| 253 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.22 |
| 254 | HALF BRICK MASONRY Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) HSR 7.28 |
| 255 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.85 |
| 256 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia Pipes HSR 22.86 |
| 257 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR 22.86 |
| 258 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.86 |
| 259 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 1. 15 mm nominal outer dia Pipes HSR 22.87 |
| 260 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 3. 25 mm nominal outer dia Pipes HSR 22.87 |
| 261 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 4. 32 mm nominal outer dia Pipes HSR 22.87 |
| 262 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 5. 40 mm nominal outer dia Pipes HSR 22.87 |
| 263 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 6. 50 mm nominal outer dia Pipes HSR 22.87 |
| 264 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 10. 150 mm nominal inner dia Pipes HSR 22.87 |
| 265 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore HSR 22.98 |
| 266 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore HSR 22.98 |
| 267 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. HSR 22.98 |
| 268 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore HSR 22.98 |
| 269 | BRASS FITTINGS Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore HSR 22.101 |
| 270 | BRASS FITTINGS Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore HSR 22.103 |
| 271 | C.P. BRASS FITTINGS Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore HSR 22.104 |
| 272 | C.P. BRASS FITTINGS Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore HSR 22.105 |
| 273 | C.P. BRASS FITTINGS Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore HSR 22.108 |
| 274 | C.P. BRASS FITTINGS Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. HSR 22.109 |
| 275 | PTMT FITTINGS Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 1. 15 mm nominal bore, 105 mm long, weighing not less than 138 gms HSR 22.124 |
| 276 | PTMT FITTINGS Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1. 15 mm nominal bore, weighing not less than 32 gms HSR 22.129 |
| 277 | STONE WARE PIPES AND FITTINGS Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 3.1. 180x150 mm size P typeWith common burnt clay non-modular bricks of class designation 7.5 HSR 22.166 |
| 278 | SOAK PITS Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. HSR 22.172 |
| 279 | LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181 |
| 280 | M Masonry Chambers Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR 21.84 |
| 281 | M Masonry Chambers Extra for every 0.30 metre depth of Inspection chamber 2. 450 mmx 600 mm inside HSR 21.85 |
| 282 | N MANHOLE CHAMBERS Construction of rectangular standard brick masonry manhole chambers to standard drawings on S.W. pipe sewers or other circular pipe sewers up to the required depth in 1.5 cement sand mortar, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium silicate on interior surface where required, reinforced cement concrete slab 180mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. the rate covers the cost of M.S. steel for R.C.C. slab labour for fixing and carriage of C.I. manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also include the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. sodium silicate shall be supplied free of cost at the stores of the Engineer-in-charge. 2.1. On 150 mm internal diameter pipe sewer - for 1.20 meters depth below ground level HSR 21.90 |
| 283 | N MANHOLE CHAMBERS Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening HSR 21.93 |
| 284 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 285 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 286 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.4. Single Socket Type B 75mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 287 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 288 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24 |
| 289 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24 |
| 290 | G DESIGN MIX CONCRETE Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level HSR 6.25 |
| 291 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR 6.30.1 |
| 292 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. HSR 6.30.2 |
| 293 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR 6.30.3 |
| 294 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) HSR 6.30.4 |
| 295 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR 6.30.5 |
| 296 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts HSR 6.30.6 |
| 297 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 14. Extra for shuttering in circular work (20% of respective centering and shuttering items) HSR 6.30.14 |
| 298 | I CENTRING AND SHUTTERING (FORM WORK) Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1. Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) HSR 6.32 |
| 299 | Schedule A By Mechanical Transport including loading, unloading and stacking 2. Earth HSR 3.1 |
| 300 | Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. HSR 4.16 |
| 301 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 302 | Special Security Enclosures (3nos.) |
| 303 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. HSR 4.1 |
| 304 | B ROOFING 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10 HSR 9.11 |
| 305 | B ROOFING Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase HSR 9.17 |
| 306 | B ROOFING Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. HSR 9.18 |
| 307 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 308 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter HSR 9.57 |
| 309 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5°110 mm bend HSR 9.58 |
| 310 | RAIN WATER SPOUTS AND PIPES Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. HSR 9.60 |
| 311 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 312 | Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% HSR 4.39 |
| 313 | CEMENT CONCRETE FLOORING Providing and laying of Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling. HSR 10.9 |
| 314 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 1. 1:2 (1 cement: 2 fine sand) HSR 11.4 |
| 315 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR 11.4 |
| 316 | CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand) HSR 11.5 |
| 317 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR 11.6 |
| 318 | CEMENT PLASTER (IN COARSE SAND) 12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) HSR 11.8 |
| 319 | KOTA STONE FLOORING Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick HSR 10.37 |
| 320 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3 mm and nuts and bolts complete. 2. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides HSR 13.9 |
| 321 | KOTA STONE FLOORING Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. HSR 10.38 |
| 322 | CERAMIC GLAZED TILES Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. HSR 10.60 |
| 323 | CERAMIC GLAZED TILES Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. HSR 10.62 |
| 324 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR 13.29 |
| 325 | INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.60 |
| 326 | GLASS/ ALUMINIUM/ PVC STRIPS IN FLOORING Providing and fixing glass strips,4 mm thick in terrazzo/ cement concrete floors. 1. 40 mm wide HSR 10.85 |
| 327 | INTERIOR FINISHING Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer`s specification. 1. Two or more coats on new work HSR 11.65 |
| 328 | INTERIOR FINISHING Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre HSR 11.69 |
| 329 | INTERIOR FINISHING Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats HSR 11.75 |
| 330 | INTERIOR FINISHING Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR 11.76 |
| 331 | INTERIOR FINISHING Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. HSR 11.77 |
| 332 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 |
| 333 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 334 | FLUSH DOOR SHUTTERS Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws HSR 12.37 |
| 335 | WINDOW GRILLS, METAL MESH, WIRE GAUGE ETC. Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. HSR 12.52 |
| 336 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 250x10 mm HSR 12.99 |
| 337 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm HSR 12.102 |
| 338 | Clearing and Grubbing Road Land . Compaction 1. Extra for laying earth/fly ash as per specifications in 20 cm layers and dressing but excluding the cost of rolling HSR 17.8 |
| 339 | Clearing and Grubbing Road Land . Compaction 2. Extra for watering the earth/fly ash laid in 20 cm layers as per specifications HSR 17.8 |
| 340 | Clearing and Grubbing Road Land . Compaction 3. Extra for rolling to specifications HSR 17.8 |
| 341 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. HSR 28.16 |
| 342 | Clearing and Grubbing Road Land . Granular Sub-Base with Close Graded Material - (Table:- 400-1) Plant mix methodConstruction of granular sub-base by providing Material as per Grading III (Table 400-I of MORTandH 5th revision) mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORTandH specifications 3. Grading III material HSR 17.14 |
| 343 | CEMENT CONCRETE PAVEMENTS Cement Concrete Pavement Construction of un-reinforced M-40 grade concrete pavement with dowel jointed, over a prepared sub base with 43 grade OPC cement concrete coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a fully computerised batching and mixing plant as per approved mix design, transported to site in transit mixer with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing, complete as per clause 602 of MORT&H specifications. HSR 17.45 |
| 344 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2. Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests HSR 22.22 |
| 345 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. HSR 22.33 |
| 346 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. HSR 22.38 |
| 347 | TUBEWELLS Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. 1.3. All types of soil400 mm dia HSR 33.6 |
| 348 | TUBEWELLS Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed and approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire and labour charges, fittings and accessories, all complete, for all depths, as per direction of Engineer-in-charge. 2. 150 mm nominal size dia having minimum wall thickness 5.00 mm HSR 33.10 |
| 349 | TUBEWELLS Supplying, filling, spreading and levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge. HSR 33.12 |
| 350 | TUBEWELLS Supplying, filling, spreading and levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer -in-charge. HSR 33.14 |
| 351 | HALF BRICK MASONRY Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) HSR 7.28 |
| 352 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.85 |
| 353 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes HSR 22.85 |
| 354 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR 22.86 |
| 355 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 4. 32 mm nominal outer dia Pipes HSR 22.87 |
| 356 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 6. 50 mm nominal outer dia Pipes HSR 22.87 |
| 357 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore HSR 22.98 |
| 358 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore HSR 22.98 |
| 359 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. HSR 22.98 |
| 360 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore HSR 22.98 |
| 361 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 5. 50 mm nominal bore HSR 22.98 |
| 362 | BRASS FITTINGS Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 2. 20 mm nominal bore HSR 22.100 |
| 363 | BRASS FITTINGS Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore HSR 22.101 |
| 364 | BRASS FITTINGS Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore HSR 22.103 |
| 365 | C.P. BRASS FITTINGS Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore HSR 22.104 |
| 366 | C.P. BRASS FITTINGS Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore HSR 22.105 |
| 367 | C.P. BRASS FITTINGS Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore HSR 22.108 |
| 368 | C.P. BRASS FITTINGS Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. HSR 22.109 |
| 369 | PTMT FITTINGS Providing and fixing PTMT grating of approved quality and colour. 1.1. Circular type 100 mm nominal dia HSR 22.123 |
| 370 | LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181 |
| 371 | M Masonry Chambers Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR 21.84 |
| 372 | M Masonry Chambers Extra for every 0.30 metre depth of Inspection chamber 3. 600 mm x 900 mm inside HSR 21.85 |
| 373 | HDPE pipes for Drainage Providing and Supplying of class SN 8 structured wall Polyethylene Piping system (Pipe with online/ offline coupler and elastomeric sealing ring) with non smooth external annular corrugated and smooth internal surface (double wall) for non-pressure underground sewerage and drainage application as confirm to IS 16098 (part II):2013 including transportation, frieght charges, inspection charges, loading, unloading, complete as specified and directed by Engineer In-Charge. 1. 250 mm Internal Diameter HSR 22.218 |
| 374 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 375 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.4. Single Socket Type B 75mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 376 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) HSR 6.1 |
| 377 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 378 | D REINFORCED CEMENT CONCRETE Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size). HSR 6.21 |
| 379 | E READY MIX CEMENT CONCRETE Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1.3. All works above plinth and up to floor IV level :M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) HSR 6.22 |
| 380 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24 |
| 381 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24 |
| 382 | G DESIGN MIX CONCRETE Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level HSR 6.25 |
| 383 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR 6.30.1 |
| 384 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. HSR 6.30.2 |
| 385 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR 6.30.3 |
| 386 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR 6.30.5 |
| 387 | I CENTRING AND SHUTTERING (FORM WORK) Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1. Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) HSR 6.32 |
| 388 | Schedule A By Mechanical Transport including loading, unloading and stacking 2. Earth HSR 3.1 |
| 389 | Schedule A By Mechanical Transport including loading, unloading and stacking 2. Earth HSR 3.1 |
| 390 | Schedule B By Manual Labour including loading, unloading and stacking for lead less than 0.50 KM 2. Earth HSR 3.2 |
| 391 | Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.1. All kind of soil Pipes, cables etc, not exceeding 80 mm dia . HSR 4.16 |
| 392 | Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. HSR 4.16 |
| 393 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 394 | Factory Shed / Correctional Compound |
| 395 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. HSR 4.1 |
| 396 | B ROOFING 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10 HSR 9.11 |
| 397 | B ROOFING Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase HSR 9.17 |
| 398 | B ROOFING Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. HSR 9.18 |
| 399 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 400 | CEILING Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 1. 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fibre manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rock wool of 48 kg /cum backing. HSR 9.50 |
| 401 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter HSR 9.57 |
| 402 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter HSR 9.57 |
| 403 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 4.2. Single tee without door110x110x110 mm HSR 9.58 |
| 404 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5°110 mm bend HSR 9.58 |
| 405 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5°150 mm bend HSR 9.58 |
| 406 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shadeArea of slab over 0.50 sqm HSR 8.26 |
| 407 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite work HSR 8.27 |
| 408 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. HSR 8.28 |
| 409 | Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% HSR 4.39 |
| 410 | CEMENT CONCRETE FLOORING Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. HSR 10.1 |
| 411 | A DOOR FRAMES, SHUTTERS AND WINDOWS Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : 8. Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading HSR 12.9 |
| 412 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 1. 1:2 (1 cement: 2 fine sand) HSR 11.4 |
| 413 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR 11.4 |
| 414 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb HSR 13.3 |
| 415 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.2. Profile B Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) HSR 13.3 |
| 416 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR 11.6 |
| 417 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) HSR 11.6 |
| 418 | TILE FLOORING Providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 3. Dark shade pigment using ordinary cement HSR 10.30 |
| 419 | CEMENT PLASTER (IN COARSE SAND) 12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) HSR 11.8 |
| 420 | KOTA STONE FLOORING Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick HSR 10.37 |
| 421 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1. 4.0 mm thick glass panes HSR 13.10 |
| 422 | CERAMIC GLAZED TILES Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. HSR 10.62 |
| 423 | VITRIFIED FLOOR TILES Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 3. Size of Tile 800x800 mm HSR 10.63 |
| 424 | VITRIFIED FLOOR TILES Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 3. Size of Tile 800x800 mm HSR 10.67 |
| 425 | VITRIFIED FLOOR TILES Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 3. Size of Tile 800x800 mm HSR 10.70 |
| 426 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR 13.29 |
| 427 | INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.60 |
| 428 | INTERIOR FINISHING Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer HSR 11.64 |
| 429 | INTERIOR FINISHING Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre HSR 11.69 |
| 430 | INTERIOR FINISHING Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats HSR 11.75 |
| 431 | INTERIOR FINISHING Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR 11.76 |
| 432 | INTERIOR FINISHING Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. HSR 11.77 |
| 433 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 |
| 434 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 435 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 1. New work (Two or more coats applied @ 1.43 litre/ 10 sqm Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm HSR 11.98 |
| 436 | FLUSH DOOR SHUTTERS Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws HSR 12.37 |
| 437 | WINDOW GRILLS, METAL MESH, WIRE GAUGE ETC. Providing and fixing M.S. grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 1. Fixed to steel windows by welding HSR 12.50 |
| 438 | HYDRAULIC DOOR CLOSERS Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. HSR 12.89 |
| 439 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm HSR 12.98 |
| 440 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm HSR 12.98 |
| 441 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 4. 150x10 mm HSR 12.99 |
| 442 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 5. 100x10 mm HSR 12.99 |
| 443 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm HSR 12.102 |
| 444 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 1. Single rubber stopper HSR 12.103 |
| 445 | C ALUMINIUM WORK Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) HSR 12.157 |
| 446 | C ALUMINIUM WORK Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 1. With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) HSR 12.159 |
| 447 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 5. White vitreous chinaware Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tap HSR 22.1 |
| 448 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing white vitreous chinaware pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. HSR 22.5 |
| 449 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. HSR 28.16 |
| 450 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing 15 mm C.P. brass Laboratory cock swan neck of best quality (to the approval of Engineer-in-charge). 1. One way HSR 22.8 |
| 451 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 1.1. Semi rigid pipe32 mm dia HSR 22.14 |
| 452 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge. HSR 22.15 |
| 453 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing in position brass oxidized gas taps (to the approval of the Engineer-in-charge) complete in all respects. 1. One way HSR 22.18 |
| 454 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2. Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests HSR 22.22 |
| 455 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 1.W.C. pan with ISI marked white solid plastic seat and lid HSR 22.23 |
| 456 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 1. Single half stall urinal with 5 litre P.V.C. automatic flushing cistern HSR 22.26 |
| 457 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. HSR 22.38 |
| 458 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) HSR 7.22 |
| 459 | HALF BRICK MASONRY Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) HSR 7.28 |
| 460 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.85 |
| 461 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes HSR 22.85 |
| 462 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR 22.86 |
| 463 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.86 |
| 464 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 5. 40 mm nominal outer dia Pipes HSR 22.87 |
| 465 | GI PIPES Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 3. 25 mm nominal bore HSR 22.94 |
| 466 | GI PIPES Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 5. 40 mm nominal bore HSR 22.94 |
| 467 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore HSR 22.98 |
| 468 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore HSR 22.98 |
| 469 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. HSR 22.98 |
| 470 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore HSR 22.98 |
| 471 | BRASS FITTINGS Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 2. 20 mm nominal bore HSR 22.100 |
| 472 | BRASS FITTINGS Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore HSR 22.101 |
| 473 | BRASS FITTINGS Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 1. 15 mm nominal bore HSR 22.103 |
| 474 | C.P. BRASS FITTINGS Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore HSR 22.104 |
| 475 | C.P. BRASS FITTINGS Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore HSR 22.105 |
| 476 | C.P. BRASS FITTINGS Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore HSR 22.107 |
| 477 | C.P. BRASS FITTINGS Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore HSR 22.108 |
| 478 | C.P. BRASS FITTINGS Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. HSR 22.109 |
| 479 | PTMT FITTINGS Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 2. 20 mm nominal bore, weighing not less than 40 gms HSR 22.129 |
| 480 | STONE WARE PIPES AND FITTINGS Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.1. 100x100 mm size P typeWith common burnt clay non-modular bricks of class designation 7.5 HSR 22.166 |
| 481 | LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181 |
| 482 | M Masonry Chambers Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 2. Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping) HSR 21.84 |
| 483 | M Masonry Chambers Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR 21.84 |
| 484 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade and PN- 4 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 3. 250 mm Outside Dia. HSR 21.96 |
| 485 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 486 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 487 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) HSR 6.1 |
| 488 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 489 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 8. 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 490 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24.1 |
| 491 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24.2 |
| 492 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR 6.30.1 |
| 493 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR 6.30.3 |
| 494 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR 6.30.5 |
| 495 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts HSR 6.30.6 |
| 496 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases HSR 6.30.7 |
| 497 | I CENTRING AND SHUTTERING (FORM WORK) Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1. Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) HSR 6.32 |
| 498 | Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. HSR 4.16 |
| 499 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 500 | Dietary Godown |
| 501 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. HSR 4.1 |
| 502 | B ROOFING 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10 HSR 9.11 |
| 503 | B ROOFING Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase HSR 9.17 |
| 504 | B ROOFING Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. HSR 9.18 |
| 505 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 506 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter HSR 9.57 |
| 507 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter HSR 9.57 |
| 508 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 4.2. Single tee without door110x110x110 mm HSR 9.58 |
| 509 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5°110 mm bend HSR 9.58 |
| 510 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5°150 mm bend HSR 9.58 |
| 511 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 512 | Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% HSR 4.39 |
| 513 | CEMENT CONCRETE FLOORING Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. HSR 10.1 |
| 514 | CEMENT CONCRETE FLOORING Providing and laying of Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling. HSR 10.9 |
| 515 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR 11.4 |
| 516 | CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand) HSR 11.5 |
| 517 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb HSR 13.3 |
| 518 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR 11.6 |
| 519 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) HSR 11.6 |
| 520 | TILE FLOORING Providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 4. Ordinary cement without any pigment HSR 10.30 |
| 521 | CEMENT PLASTER (IN COARSE SAND) 12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) HSR 11.8 |
| 522 | CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge HSR 11.17 |
| 523 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 1. Using M.S. angels 40x40x6 mm for diagonal braces HSR 13.6 |
| 524 | KOTA STONE FLOORING Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick HSR 10.37 |
| 525 | KOTA STONE FLOORING Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. HSR 10.38 |
| 526 | GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. HSR 10.50 |
| 527 | CERAMIC GLAZED TILES Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. HSR 10.60 |
| 528 | CERAMIC GLAZED TILES Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. HSR 10.62 |
| 529 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR 13.29 |
| 530 | STAINLESS STEEL RAILING Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). HSR 13.41 |
| 531 | INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.60 |
| 532 | INTERIOR FINISHING Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre HSR 11.69 |
| 533 | INTERIOR FINISHING Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats HSR 11.75 |
| 534 | INTERIOR FINISHING Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR 11.76 |
| 535 | INTERIOR FINISHING Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. HSR 11.77 |
| 536 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 |
| 537 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 538 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 1. New work (Two or more coats applied @ 1.43 litre/ 10 sqm Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm HSR 11.98 |
| 539 | FLUSH DOOR SHUTTERS Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws HSR 12.37 |
| 540 | WINDOW GRILLS, METAL MESH, WIRE GAUGE ETC. Providing and fixing M.S. grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 1. Fixed to steel windows by welding HSR 12.50 |
| 541 | WINDOW GRILLS, METAL MESH, WIRE GAUGE ETC. Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. HSR 12.52 |
| 542 | STAINLESS STEEL FITTINGS Providing and fixing bright /matt finished Stainless Steel handles of approved quality and make with necessary screws etc all complete. 1. 125 mm HSR 12.75 |
| 543 | STAINLESS STEEL FITTINGS Providing and fixing bright /matt finished Stainless Steel handles of approved quality and make with necessary screws etc all complete. 2. 100mm HSR 12.75 |
| 544 | HYDRAULIC DOOR CLOSERS Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. HSR 12.89 |
| 545 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm HSR 12.98 |
| 546 | FRP DOOR/WINDOW FRAMES AND SHUTTERS Providing and fixing factory made Fibreglass Reinforced plastics (F.R.P.) chajja 4 mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology, resulting in void free compact laminate in single piece, having smooth gradual slope curvature for easy drainage of water and duly reinforced by 2 Nos. vertically and 1 Nos. horizontally 50x2 mm thick M.S. flat with 12 mm in built hole for grouting on the existing wall along with the 50 mm flanges duly inserted and sealed in the wall complete in one single piece casted monolithically, including all necessary fittings . The FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746, duly reinforced with fibre glass chopped strand mat (CSM) as per IS: 11551 complete with protective Gel coat U/V coating on Top for complete resistance from the extreme of temperature, weather and sunlight (Only plan area of chajjas shall be measured for making payment). HSR 12.145 |
| 547 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 5. White vitreous chinaware Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tap HSR 22.1 |
| 548 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing white vitreous chinaware pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. HSR 22.5 |
| 549 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. HSR 28.16 |
| 550 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 1.W.C. pan with ISI marked white solid plastic seat and lid HSR 22.23 |
| 551 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. HSR 22.38 |
| 552 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.21 |
| 553 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.22 |
| 554 | HALF BRICK MASONRY Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) HSR 7.28 |
| 555 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.85 |
| 556 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR 22.86 |
| 557 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.86 |
| 558 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 5. 40 mm nominal outer dia Pipes HSR 22.87 |
| 559 | GI PIPES Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 3. 25 mm nominal bore HSR 22.94 |
| 560 | GI PIPES Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 5. 40 mm nominal bore HSR 22.94 |
| 561 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore HSR 22.98.1 |
| 562 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore HSR 22.98.2 |
| 563 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. HSR 22.98.3 |
| 564 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore HSR 22.98.4 |
| 565 | BRASS FITTINGS Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 3. 25 mm nominal bore HSR 22.100.3 |
| 566 | BRASS FITTINGS Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore HSR 22.101 |
| 567 | BRASS FITTINGS Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 1. 15 mm nominal bore HSR 22.103 |
| 568 | C.P. BRASS FITTINGS Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore HSR 22.105 |
| 569 | C.P. BRASS FITTINGS Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore HSR 22.107 |
| 570 | C.P. BRASS FITTINGS Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore HSR 22.108 |
| 571 | C.P. BRASS FITTINGS Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. HSR 22.109 |
| 572 | LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181 |
| 573 | M Masonry Chambers Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR 21.84 |
| 574 | N MANHOLE CHAMBERS Construction of rectangular standard brick masonry manhole chambers to standard drawings on S.W. pipe sewers or other circular pipe sewers up to the required depth in 1.5 cement sand mortar, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium silicate on interior surface where required, reinforced cement concrete slab 180mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. the rate covers the cost of M.S. steel for R.C.C. slab labour for fixing and carriage of C.I. manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also include the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. sodium silicate shall be supplied free of cost at the stores of the Engineer-in-charge. 2.1. On 150 mm internal diameter pipe sewer - for 1.20 meters depth below ground level HSR 21.90 |
| 575 | HDPE pipes for Drainage Providing and Supplying of class SN 8 structured wall Polyethylene Piping system (Pipe with online/ offline coupler and elastomeric sealing ring) with non smooth external annular corrugated and smooth internal surface (double wall) for non-pressure underground sewerage and drainage application as confirm to IS 16098 (part II):2013 including transportation, frieght charges, inspection charges, loading, unloading, complete as specified and directed by Engineer In-Charge. 1. 250 mm Internal Diameter HSR 22.218 |
| 576 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 577 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 578 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24 |
| 579 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24 |
| 580 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR 6.30.1 |
| 581 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. HSR 6.30.2 |
| 582 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR 6.30.3 |
| 583 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) HSR 6.30.4 |
| 584 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR 6.30.5 |
| 585 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts HSR 6.30.6 |
| 586 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 14. Extra for shuttering in circular work (20% of respective centering and shuttering items) HSR 6.30.14 |
| 587 | I CENTRING AND SHUTTERING (FORM WORK) Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1. Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) HSR 6.32 |
| 588 | B0247. Polycarbonate sheet 2mm thick HSR 2 |
| 589 | Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. HSR 4.16 |
| 590 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 591 | Hospital Block |
| 592 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. HSR 4.1 |
| 593 | B ROOFING 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10 HSR 9.11 |
| 594 | B ROOFING Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase HSR 9.17 |
| 595 | B ROOFING Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. HSR 9.18 |
| 596 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 597 | CEILING Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 1. 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fibre manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rock wool of 48 kg /cum backing. HSR 9.50 |
| 598 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter HSR 9.57 |
| 599 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter HSR 9.57 |
| 600 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 3.2. Single tee with door110x110x110 mm HSR 9.58 |
| 601 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 4.2. Single tee without door110x110x110 mm HSR 9.58 |
| 602 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5°110 mm bend HSR 9.58 |
| 603 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5°150 mm bend HSR 9.58 |
| 604 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shadeArea of slab over 0.50 sqm HSR 8.26 |
| 605 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite work HSR 8.27 |
| 606 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. HSR 8.28 |
| 607 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 608 | Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% HSR 4.39 |
| 609 | CEMENT CONCRETE FLOORING Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. HSR 10.1 |
| 610 | A DOOR FRAMES, SHUTTERS AND WINDOWS Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : 8. Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading HSR 12.9 |
| 611 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 1. 1:2 (1 cement: 2 fine sand) HSR 11.4 |
| 612 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR 11.4 |
| 613 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb HSR 13.3 |
| 614 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.2. Profile B Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) HSR 13.3 |
| 615 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR 11.6.1 |
| 616 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) HSR 11.6.2 |
| 617 | TILE FLOORING Providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 3. Dark shade pigment using ordinary cement HSR 10.30 |
| 618 | CEMENT PLASTER (IN COARSE SAND) 12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) HSR 11.8 |
| 619 | KOTA STONE FLOORING Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick HSR 10.37 |
| 620 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1. 4.0 mm thick glass panes HSR 13.10 |
| 621 | GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. HSR 10.50 |
| 622 | CERAMIC GLAZED TILES Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. HSR 10.62 |
| 623 | VITRIFIED FLOOR TILES Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 3. Size of Tile 800x800 mm HSR 10.63 |
| 624 | VITRIFIED FLOOR TILES Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 3. Size of Tile 800x800 mm HSR 10.67 |
| 625 | VITRIFIED FLOOR TILES Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 3. Size of Tile 800x800 mm HSR 10.70 |
| 626 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR 13.29 |
| 627 | INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.60 |
| 628 | INTERIOR FINISHING Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre HSR 11.69 |
| 629 | INTERIOR FINISHING Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats HSR 11.75 |
| 630 | INTERIOR FINISHING Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR 11.76 |
| 631 | INTERIOR FINISHING Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. HSR 11.77 |
| 632 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 |
| 633 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 634 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 1. New work (Two or more coats applied @ 1.43 litre/ 10 sqm Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm HSR 11.98 |
| 635 | FLUSH DOOR SHUTTERS Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws HSR 12.37 |
| 636 | WINDOW GRILLS, METAL MESH, WIRE GAUGE ETC. Providing and fixing M.S. grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 1. Fixed to steel windows by welding HSR 12.50 |
| 637 | HYDRAULIC DOOR CLOSERS Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. HSR 12.89 |
| 638 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm HSR 12.98 |
| 639 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm HSR 12.98 |
| 640 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 4. 150x10 mm HSR 12.99 |
| 641 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 5. 100x10 mm HSR 12.99 |
| 642 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm HSR 12.102 |
| 643 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 100 mm HSR 12.102 |
| 644 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 1. Single rubber stopper HSR 12.103 |
| 645 | PTMT (Polytetra Methylene Terephthalate) FITTINGS Providing and fixing of roller blinds on windows complete with material and labour complete with push up and down arrangement as per approved design / colour and Engineer-in-charge. HSR 12.114 |
| 646 | C ALUMINIUM WORK Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) HSR 12.157 |
| 647 | C ALUMINIUM WORK Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 1. With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) HSR 12.159 |
| 648 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 5. White vitreous chinaware Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tap HSR 22.1 |
| 649 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing white vitreous chinaware pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. HSR 22.5 |
| 650 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing white vitreous chinaware laboratory sink including making all connections excluding cost of fittings : 2. Size 600x450x200 mm HSR 22.7 |
| 651 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. HSR 28.16 |
| 652 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing 15 mm C.P. brass Laboratory cock swan neck of best quality (to the approval of Engineer-in-charge). 1. One way HSR 22.8 |
| 653 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 withC.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: 2.1. Kitchen sink without drain board 610x510 mm bowl depth 200 mm HSR 22.10 |
| 654 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 1.1. Semi rigid pipe32 mm dia HSR 22.14 |
| 655 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge. HSR 22.15 |
| 656 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing in position brass oxidized gas taps (to the approval of the Engineer-in-charge) complete in all respects. 1. One way HSR 22.18 |
| 657 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 1.W.C. pan with ISI marked white solid plastic seat and lid HSR 22.23 |
| 658 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 1. Single half stall urinal with 5 litre P.V.C. automatic flushing cistern HSR 22.26 |
| 659 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. HSR 22.38 |
| 660 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) HSR 7.22 |
| 661 | HALF BRICK MASONRY Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) HSR 7.28 |
| 662 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.85 |
| 663 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes HSR 22.85 |
| 664 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR 22.86 |
| 665 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.86 |
| 666 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 5. 40 mm nominal outer dia Pipes HSR 22.87 |
| 667 | GI PIPES Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 3. 25 mm nominal bore HSR 22.94 |
| 668 | GI PIPES Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 5. 40 mm nominal bore HSR 22.94 |
| 669 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore HSR 22.98.1 |
| 670 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore HSR 22.98.2 |
| 671 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. HSR 22.98.3 |
| 672 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore HSR 22.98.4 |
| 673 | BRASS FITTINGS Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 2. 20 mm nominal bore HSR 22.100.2 |
| 674 | BRASS FITTINGS Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore HSR 22.101 |
| 675 | BRASS FITTINGS Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 1. 15 mm nominal bore HSR 22.103 |
| 676 | BRASS FITTINGS Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore HSR 22.103 |
| 677 | C.P. BRASS FITTINGS Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore HSR 22.104 |
| 678 | C.P. BRASS FITTINGS Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore HSR 22.105 |
| 679 | C.P. BRASS FITTINGS Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore HSR 22.107 |
| 680 | C.P. BRASS FITTINGS Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore HSR 22.108 |
| 681 | C.P. BRASS FITTINGS Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. HSR 22.109 |
| 682 | PTMT FITTINGS Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 2. 20 mm nominal bore, weighing not less than 40 gms HSR 22.129 |
| 683 | STONE WARE PIPES AND FITTINGS Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.1. 100x100 mm size P typeWith common burnt clay non-modular bricks of class designation 7.5 HSR 22.166 |
| 684 | LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181 |
| 685 | M Masonry Chambers Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 2. Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping) HSR 21.84 |
| 686 | M Masonry Chambers Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR 21.84 |
| 687 | N MANHOLE CHAMBERS Construction of rectangular standard brick masonry manhole chambers to standard drawings on S.W. pipe sewers or other circular pipe sewers up to the required depth in 1.5 cement sand mortar, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium silicate on interior surface where required, reinforced cement concrete slab 180mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. the rate covers the cost of M.S. steel for R.C.C. slab labour for fixing and carriage of C.I. manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also include the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. sodium silicate shall be supplied free of cost at the stores of the Engineer-in-charge. 2.1. On 150 mm internal diameter pipe sewer - for 1.20 meters depth below ground level HSR 21.90 |
| 688 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade and PN- 4 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 3. 250 mm Outside Dia. HSR 21.96 |
| 689 | BATHROOM ACCESSORIES Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. HSR 22.209 |
| 690 | BATHROOM ACCESSORIES Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 4. Rectangular shape 1500x450 mm HSR 22.210 |
| 691 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 692 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 693 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) HSR 6.1 |
| 694 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 695 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24 |
| 696 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24 |
| 697 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR 6.30.1 |
| 698 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR 6.30.3 |
| 699 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) HSR 6.30.4 |
| 700 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR 6.30.5 |
| 701 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts HSR 6.30.6 |
| 702 | I CENTRING AND SHUTTERING (FORM WORK) Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1. Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) HSR 6.32 |
| 703 | Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. HSR 4.16 |
| 704 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 705 | Male Barrack Type- II (1 no.) |
| 706 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. HSR 4.1 |
| 707 | B ROOFING 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10 HSR 9.11 |
| 708 | B ROOFING Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase HSR 9.17 |
| 709 | B ROOFING Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. HSR 9.18 |
| 710 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 711 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter HSR 9.57 |
| 712 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.1. Coupler 75 mm HSR 9.58 |
| 713 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 2.3. Single push fit Coupler 150 mm HSR 9.58 |
| 714 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5°110 mm bend HSR 9.58 |
| 715 | RAIN WATER SPOUTS AND PIPES Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. HSR 9.60 |
| 716 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 717 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. HSR 4.33 |
| 718 | Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% HSR 4.39 |
| 719 | CEMENT CONCRETE FLOORING Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. HSR 10.1 |
| 720 | C FIXING INCLUDING CARRIAGE Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge HSR 21.28 |
| 721 | CEMENT CONCRETE FLOORING Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4 HSR 10.7 |
| 722 | CEMENT CONCRETE FLOORING Providing and laying of Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling. HSR 10.9 |
| 723 | CEMENT CONCRETE FLOORING Providing and laying cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 1. 18 mm thick HSR 10.13 |
| 724 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR 11.4 |
| 725 | TERRAZO FLOORING Providing and laying of 40 mm thick marble chips flooring, rubbed and polished to granolithic finish, under layer 28 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) and top layer 12 mm thick with white, black, chocolate, grey yellow or green marble chips of sizes from 7 mm to 10 mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 2:3 (2 cement marble powder mix : 3 marble chips) by volume, including cement slurry etc. complete : 2. Light shade pigment with white cement HSR 10.21 |
| 726 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb HSR 13.3 |
| 727 | G STONE WARE INTERCEPTING TRAPS, FLAP VALVES, ROAD GULLIES ETC. Fixing cast iron road gully grating and frame complete including carriage from the stores of the Engineer-in-charge of the works, loading, fixing and erecting the same in position to correct lines and levels in 1:2 cement sand mortar and painting of grating and frame with coal tar. HSR 21.48 |
| 728 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) HSR 11.6 |
| 729 | TILE FLOORING Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 2. Medium shade pigment using 50% white cement, 50% ordinary cement HSR 10.29 |
| 730 | CEMENT PLASTER (IN COARSE SAND) 12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) HSR 11.8 |
| 731 | CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge HSR 11.17 |
| 732 | KOTA STONE FLOORING Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick HSR 10.37 |
| 733 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3 mm and nuts and bolts complete. 2. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides HSR 13.9 |
| 734 | KOTA STONE FLOORING Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. HSR 10.38 |
| 735 | MARBLE STONE FLOORING Providing and laying Baroda Green marble stone 17mm and above thick in risers of step, skirting , dado, pillars and wall lining included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR 10.47 |
| 736 | MARBLE STONE FLOORING Providing and laying Baroda Green marble stone 17mm and above thick flooring included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR 10.48 |
| 737 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing hard drawn steel wire fabric 75 mm X 25 mm rectangular mesh with 3.25 mm dia wire fixed on steel windows of standard rolled sections with 3 mm thick flat iron cover moulding of 12.5 mm width fixed with machine screws welded complete in all respect. HSR 13.18 |
| 738 | GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. HSR 10.50 |
| 739 | CERAMIC GLAZED TILES Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. HSR 10.62 |
| 740 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR 13.29 |
| 741 | RENDERING ON RCC SURFACE Smooth finishing of the exposed surface of R.C.C. work with 10 mm thick cement mortar 1:4 (1 Cement : 4 fine sand). HSR 11.51 |
| 742 | INTERIOR FINISHING Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete HSR 11.58 |
| 743 | INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.60 |
| 744 | INTERIOR FINISHING Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works HSR 11.68 |
| 745 | INTERIOR FINISHING Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre HSR 11.69 |
| 746 | INTERIOR FINISHING Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats HSR 11.75 |
| 747 | INTERIOR FINISHING Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR 11.76 |
| 748 | INTERIOR FINISHING Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. HSR 11.77 |
| 749 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 |
| 750 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 751 | FLUSH DOOR SHUTTERS Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws HSR 12.37 |
| 752 | STAINLESS STEEL FITTINGS Providing and fixing bright /matt finished Stainless Steel handles of approved quality and make with necessary screws etc all complete. 1. 125 mm HSR 12.75 |
| 753 | BRASS FITTINGS Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 2. 200x10 mm HSR 12.78 |
| 754 | HYDRAULIC DOOR CLOSERS Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. HSR 12.89 |
| 755 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm HSR 12.98 |
| 756 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 250x10 mm HSR 12.99 |
| 757 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 200x10 mm HSR 12.99 |
| 758 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 4. 150x10 mm HSR 12.99 |
| 759 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. HSR 28.16 |
| 760 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2. Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests HSR 22.22 |
| 761 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing partitions for different type of urinals. 1.1.1. Vitreous Chinaware Partition plate.Small size 680mm x 330 mm White HSR 22.50 |
| 762 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.21 |
| 763 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.22 |
| 764 | HALF BRICK MASONRY Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) HSR 7.28 |
| 765 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.85 |
| 766 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia Pipes HSR 22.86 |
| 767 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR 22.86 |
| 768 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.86 |
| 769 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 1. 15 mm nominal outer dia Pipes HSR 22.87 |
| 770 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 3. 25 mm nominal outer dia Pipes HSR 22.87 |
| 771 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 4. 32 mm nominal outer dia Pipes HSR 22.87 |
| 772 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 5. 40 mm nominal outer dia Pipes HSR 22.87 |
| 773 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore HSR 22.98 |
| 774 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore HSR 22.98 |
| 775 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. HSR 22.98 |
| 776 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore HSR 22.98 |
| 777 | BRASS FITTINGS Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore HSR 22.101 |
| 778 | BRASS FITTINGS Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore HSR 22.103 |
| 779 | C.P. BRASS FITTINGS Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore HSR 22.104 |
| 780 | C.P. BRASS FITTINGS Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore HSR 22.105 |
| 781 | C.P. BRASS FITTINGS Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore HSR 22.108 |
| 782 | C.P. BRASS FITTINGS Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. HSR 22.109 |
| 783 | STONE WARE PIPES AND FITTINGS Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 3.1. 180x150 mm size P typeWith common burnt clay non-modular bricks of class designation 7.5 HSR 22.166 |
| 784 | LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181 |
| 785 | M Masonry Chambers Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR 21.84 |
| 786 | N MANHOLE CHAMBERS Construction of rectangular standard brick masonry manhole chambers to standard drawings on S.W. pipe sewers or other circular pipe sewers up to the required depth in 1.5 cement sand mortar, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium silicate on interior surface where required, reinforced cement concrete slab 180mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. the rate covers the cost of M.S. steel for R.C.C. slab labour for fixing and carriage of C.I. manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also include the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. sodium silicate shall be supplied free of cost at the stores of the Engineer-in-charge. 2.1. On 150 mm internal diameter pipe sewer - for 1.20 meters depth below ground level HSR 21.90 |
| 787 | N MANHOLE CHAMBERS Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening HSR 21.93 |
| 788 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 789 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 790 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.4. Single Socket Type B 75mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 791 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 792 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24 |
| 793 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24 |
| 794 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR 6.30.1 |
| 795 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. HSR 6.30.2 |
| 796 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR 6.30.3 |
| 797 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) HSR 6.30.4 |
| 798 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR 6.30.5 |
| 799 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts HSR 6.30.6 |
| 800 | I CENTRING AND SHUTTERING (FORM WORK) Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1. Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) HSR 6.32 |
| 801 | Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. HSR 4.16 |
| 802 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 803 | Cook House |
| 804 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. HSR 4.1 |
| 805 | B ROOFING 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10 HSR 9.11 |
| 806 | B ROOFING Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase HSR 9.17 |
| 807 | B ROOFING Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. HSR 9.18 |
| 808 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 809 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1. 75 mm diameter HSR 9.57 |
| 810 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter HSR 9.57 |
| 811 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5°110 mm bend HSR 9.58 |
| 812 | RAIN WATER SPOUTS AND PIPES Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 2. 110 mm HSR 9.59 |
| 813 | RAIN WATER SPOUTS AND PIPES Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. HSR 9.60 |
| 814 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 815 | Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% HSR 4.39 |
| 816 | CEMENT CONCRETE FLOORING Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. HSR 10.1 |
| 817 | CEMENT CONCRETE FLOORING Providing and laying of Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling. HSR 10.9 |
| 818 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 1. 1:2 (1 cement: 2 fine sand) HSR 11.4 |
| 819 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR 11.4 |
| 820 | CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand) HSR 11.5 |
| 821 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb HSR 13.3 |
| 822 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR 11.6 |
| 823 | TILE FLOORING Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 2. Medium shade pigment using 50% white cement, 50% ordinary cement HSR 10.29 |
| 824 | KOTA STONE FLOORING Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick HSR 10.37 |
| 825 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3 mm and nuts and bolts complete. 2. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides HSR 13.9 |
| 826 | MARBLE STONE FLOORING Providing and laying Baroda Green marble stone 17mm and above thick in risers of step, skirting , dado, pillars and wall lining included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR 10.47 |
| 827 | MARBLE STONE FLOORING Providing and laying Baroda Green marble stone 17mm and above thick flooring included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR 10.48 |
| 828 | GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. HSR 10.50 |
| 829 | CERAMIC GLAZED TILES Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. HSR 10.60 |
| 830 | CERAMIC GLAZED TILES Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. HSR 10.62 |
| 831 | VITRIFIED FLOOR TILES Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm HSR 10.64 |
| 832 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR 13.29 |
| 833 | ROLLING/COLLAPSIBLE/SLIDING DOOR SHUTTERS Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 1. 80x1.25 mm M.S. laths with 1.25 mm thick top cover HSR 13.37 |
| 834 | ROLLING/COLLAPSIBLE/SLIDING DOOR SHUTTERS Providing and fixing ball bearing for rolling shutters. HSR 13.38 |
| 835 | ROLLING/COLLAPSIBLE/SLIDING DOOR SHUTTERS Extra for providing mechanical device chain and crank operation for operating rolling shutters. 1. Exceeding 10.00 sqm and up to 16.80 sqm in the area HSR 13.39 |
| 836 | INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.60 |
| 837 | INTERIOR FINISHING Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre HSR 11.69 |
| 838 | INTERIOR FINISHING Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats HSR 11.75 |
| 839 | INTERIOR FINISHING Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR 11.76 |
| 840 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 |
| 841 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 842 | FLUSH DOOR SHUTTERS Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws HSR 12.37 |
| 843 | WINDOW GRILLS, METAL MESH, WIRE GAUGE ETC. Providing and fixing M.S. grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 1. Fixed to steel windows by welding HSR 12.50 |
| 844 | WINDOW GRILLS, METAL MESH, WIRE GAUGE ETC. Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. HSR 12.52 |
| 845 | HYDRAULIC DOOR CLOSERS Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. HSR 12.89 |
| 846 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 200x10 mm HSR 12.99 |
| 847 | ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm HSR 12.102 |
| 848 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing white vitreous chinaware pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. HSR 22.5 |
| 849 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing white vitreous chinaware laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 2. Size 600x450x200 mm HSR 22.6 |
| 850 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. HSR 28.16 |
| 851 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 withC.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: 2.2. Kitchen sink without drain board610x460 mm bowl depth 200 mm HSR 22.10 |
| 852 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 1.1. Semi rigid pipe32 mm dia HSR 22.14 |
| 853 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 1. Single half stall urinal with 5 litre P.V.C. automatic flushing cistern HSR 22.26 |
| 854 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. HSR 22.33 |
| 855 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. HSR 22.38 |
| 856 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.21 |
| 857 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.22 |
| 858 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) HSR 7.22 |
| 859 | HALF BRICK MASONRY Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 1. Cement mortar 1:3 (1 cement :3 coarse sand) HSR 7.28 |
| 860 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia Pipes HSR 22.85 |
| 861 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.85 |
| 862 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia Pipes HSR 22.86 |
| 863 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.86 |
| 864 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 1. 15 mm nominal outer dia Pipes HSR 22.87 |
| 865 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 3. 25 mm nominal outer dia Pipes HSR 22.87 |
| 866 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore HSR 22.98.1 |
| 867 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore HSR 22.98.2 |
| 868 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. HSR 22.98.3 |
| 869 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore HSR 22.98.4 |
| 870 | BRASS FITTINGS Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 3. 25 mm nominal bore HSR 22.100 |
| 871 | BRASS FITTINGS Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore HSR 22.101 |
| 872 | BRASS FITTINGS Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.2. 45 cm length 20 mm nominal bore HSR 22.101 |
| 873 | BRASS FITTINGS Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore HSR 22.103 |
| 874 | C.P. BRASS FITTINGS Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore HSR 22.104 |
| 875 | C.P. BRASS FITTINGS Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore HSR 22.105 |
| 876 | C.P. BRASS FITTINGS Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore HSR 22.108 |
| 877 | C.P. BRASS FITTINGS Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. HSR 22.109 |
| 878 | PTMT FITTINGS Providing and fixing PTMT grating of approved quality and colour. 1.1. Circular type 100 mm nominal dia HSR 22.123 |
| 879 | STONE WARE PIPES AND FITTINGS Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 3.1. 180x150 mm size P typeWith common burnt clay non-modular bricks of class designation 7.5 HSR 22.166 |
| 880 | SOAK PITS Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. 1. With common burnt clay non-modular bricks of class designation 7.5 HSR 22.171 |
| 881 | LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181 |
| 882 | M Masonry Chambers Extra for every 0.30 metre depth of Inspection chamber 1. 450 mm x 450 mm inside HSR 21.85 |
| 883 | N MANHOLE CHAMBERS Construction of rectangular standard brick masonry manhole chambers to standard drawings on S.W. pipe sewers or other circular pipe sewers up to the required depth in 1.5 cement sand mortar, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium silicate on interior surface where required, reinforced cement concrete slab 180mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. the rate covers the cost of M.S. steel for R.C.C. slab labour for fixing and carriage of C.I. manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also include the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. sodium silicate shall be supplied free of cost at the stores of the Engineer-in-charge. 2.1. On 150 mm internal diameter pipe sewer - for 1.20 meters depth below ground level HSR 21.90 |
| 884 | N MANHOLE CHAMBERS Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening HSR 21.93 |
| 885 | Providing salt glazed stone ware pipes grade ‘A’ in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 including the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. 1. 100mm i/d HSR 21.94 |
| 886 | HDPE pipes for Drainage Providing and Supplying of class SN 8 structured wall Polyethylene Piping system (Pipe with online/ offline coupler and elastomeric sealing ring) with non smooth external annular corrugated and smooth internal surface (double wall) for non-pressure underground sewerage and drainage application as confirm to IS 16098 (part II):2013 including transportation, frieght charges, inspection charges, loading, unloading, complete as specified and directed by Engineer In-Charge. 1. 250 mm Internal Diameter HSR 22.218 |
| 887 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 888 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 889 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.4. Single Socket Type B 75mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 890 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) HSR 6.1 |
| 891 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 892 | Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 10.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in allrespect 10. Discharge Capacity (LPM) - 500 Power Capacity (BHP) - 2 HSR 21.104 |
| 893 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24.1 |
| 894 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24.2 |
| 895 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR 6.30.1 |
| 896 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR 6.30.3 |
| 897 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR 6.30.5 |
| 898 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts HSR 6.30.6 |
| 899 | I CENTRING AND SHUTTERING (FORM WORK) Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1. Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) HSR 6.32 |
| 900 | Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.1. All kind of soil Pipes, cables etc, not exceeding 80 mm dia . HSR 4.16 |
| 901 | Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. HSR 4.16 |
| 902 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 903 | Control Room HSR |
| 904 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. HSR 4.1 |
| 905 | B ROOFING 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10 HSR 9.11 |
| 906 | B ROOFING Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase HSR 9.17 |
| 907 | B ROOFING Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. HSR 9.18 |
| 908 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil HSR 4.12 |
| 909 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter HSR 9.57 |
| 910 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.1. Coupler 75 mm HSR 9.58 |
| 911 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 2.3. Single push fit Coupler 150 mm HSR 9.58 |
| 912 | RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5°110 mm bend HSR 9.58 |
| 913 | RAIN WATER SPOUTS AND PIPES Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. HSR 9.60 |
| 914 | KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shadeArea of slab over 0.50 sqm HSR 8.26 |
| 915 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR 4.32 |
| 916 | Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% HSR 4.39 |
| 917 | CEMENT CONCRETE FLOORING Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. HSR 10.1 |
| 918 | C FIXING INCLUDING CARRIAGE Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge HSR 21.28 |
| 919 | CEMENT CONCRETE FLOORING Providing and laying of screed of 40 mm thick cement concrete 1:4:8 to be laid below the topping. HSR 10.6 |
| 920 | CEMENT CONCRETE FLOORING Providing and laying of Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling. HSR 10.9 |
| 921 | CEMENT PLASTER (IN FINE SAND) 10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR 11.4 |
| 922 | STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb HSR 13.3 |
| 923 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR 11.6 |
| 924 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) HSR 11.6 |
| 925 | TILE FLOORING Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 2. Medium shade pigment using 50% white cement, 50% ordinary cement HSR 10.29 |
| 926 | CEMENT PLASTER (IN COARSE SAND) 12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) HSR 11.8 |
| 927 | CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge HSR 11.17 |
| 928 | MARBLE STONE FLOORING Providing and laying Baroda Green marble stone 17mm and above thick in risers of step, skirting , dado, pillars and wall lining included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR 10.47 |
| 929 | MARBLE STONE FLOORING Providing and laying Baroda Green marble stone 17mm and above thick flooring included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR 10.48 |
| 930 | GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. HSR 10.50 |
| 931 | GRANITE FLOORING Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. HSR 10.51 |
| 932 | CERAMIC GLAZED TILES Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. HSR 10.62 |
| 933 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR 13.29 |
| 934 | STAINLESS STEEL RAILING Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). HSR 13.41 |
| 935 | INTERIOR FINISHING Providing and laying average 6mm thick POP Coating on walls, Ceiling, beams and lintels etc. complete in all respects as approved by the Engineer-In-Charge. HSR 11.57 |
| 936 | INTERIOR FINISHING Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete HSR 11.58 |
| 937 | INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.60 |
| 938 | INTERIOR FINISHING Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre HSR 11.69 |
| 939 | INTERIOR FINISHING Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats HSR 11.75 |
| 940 | INTERIOR FINISHING Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR 11.76 |
| 941 | INTERIOR FINISHING Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. HSR 11.77 |
| 942 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR 11.78 |
| 943 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR 11.95 |
| 944 | CUPBOARD SHUTTERS Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately):2. 18 mm thick HSR 12.26 |
| 945 | CUPBOARD SHUTTERS Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 2. 25 mm thick HSR 12.27 |
| 946 | CUPBOARD SHUTTERS Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge HSR 12.3 |
| 947 | FLUSH DOOR SHUTTERS Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws HSR 12.37 |
| 948 | FLUSH DOOR SHUTTERS Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 3. 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws HSR 12.37 |
| 949 | WINDOW GRILLS, METAL MESH, WIRE GAUGE ETC. Providing and fixing M.S. grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 1. Fixed to steel windows by welding HSR 12.50 |
| 950 | STAINLESS STEEL FITTINGS Providing and fixing bright /matt finished Stainless Steel handles of approved quality and make with necessary screws etc all complete. 1. 125 mm HSR 12.75 |
| 951 | BRASS FITTINGS Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 2. 200x10 mm HSR 12.78 |
| 952 | HYDRAULIC DOOR CLOSERS Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. HSR 12.89 |
| 953 | PTMT (Polytetra Methylene Terephthalate) FITTINGS Providing and fixing of roller blinds on windows complete with material and labour complete with push up and down arrangement as per approved design / colour and Engineer-in-charge. HSR 12.114 |
| 954 | ALUMINIUM FALSE CEILING Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 1. With toughened glass panes of 6 mm thickness (weight not less than 15 kg/sqm) HSR 12.177 |
| 955 | WATERPROOFING TREATMENT TO RETAINING WALL AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENTPITCH FREE POLYURETHANE COATING Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. HSR 28.16 |
| 956 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 withC.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: 2.1. Kitchen sink without drain board 610x510 mm bowl depth 200 mm HSR 22.10 |
| 957 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing 100 mm sand cast Iron grating for gully trap. HSR 22.19 |
| 958 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 2. Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests HSR 22.22 |
| 959 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 1. Single half stall urinal with 5 litre P.V.C. automatic flushing cistern HSR 22.26 |
| 960 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. HSR 22.33 |
| 961 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. HSR 22.38 |
| 962 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing toilet paper holder : 1. C.P. brass HSR 22.42 |
| 963 | WCs, URINALS AND URINAL PARTITIONS Providing and fixing partitions for different type of urinals. 1.1.1. Vitreous Chinaware Partition plate.Small size 680mm x 330 mm White HSR 22.50 |
| 964 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.21 |
| 965 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR 7.22 |
| 966 | HALF BRICK MASONRY Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) HSR 7.28 |
| 967 | SEWERAGE DISPOSAL SYSTEMS Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) including disposal of malba. HSR 22.84 |
| 968 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR 22.85 |
| 969 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR 22.85 |
| 970 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR 22.86 |
| 971 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 2. 20 mm nominal outer dia Pipes HSR 22.87 |
| 972 | C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 3. 25 mm nominal outer dia Pipes HSR 22.87 |
| 973 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore HSR 22.98 |
| 974 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. HSR 22.98 |
| 975 | BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore HSR 22.98 |
| 976 | BRASS FITTINGS Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore HSR 22.101 |
| 977 | BRASS FITTINGS Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore HSR 22.103 |
| 978 | C.P. BRASS FITTINGS Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore HSR 22.104 |
| 979 | C.P. BRASS FITTINGS Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore HSR 22.105 |
| 980 | C.P. BRASS FITTINGS Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore HSR 22.106 |
| 981 | C.P. BRASS FITTINGS Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore HSR 22.107 |
| 982 | C.P. BRASS FITTINGS Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore HSR 22.108 |
| 983 | C.P. BRASS FITTINGS Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. HSR 22.109 |
| 984 | STONE WARE PIPES AND FITTINGS Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.1. 100x100 mm size P typeWith common burnt clay non-modular bricks of class designation 7.5 HSR 22.166 |
| 985 | LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181 |
| 986 | M Masonry Chambers Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR 21.84 |
| 987 | M Masonry Chambers Extra for every 0.30 metre depth of Inspection chamber 2. 450 mmx 600 mm inside HSR 21.85 |
| 988 | N MANHOLE CHAMBERS Construction of rectangular standard brick masonry manhole chambers to standard drawings on S.W. pipe sewers or other circular pipe sewers up to the required depth in 1.5 cement sand mortar, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium silicate on interior surface where required, reinforced cement concrete slab 180mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. the rate covers the cost of M.S. steel for R.C.C. slab labour for fixing and carriage of C.I. manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also include the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. sodium silicate shall be supplied free of cost at the stores of the Engineer-in-charge. 2.1. On 150 mm internal diameter pipe sewer - for 1.20 meters depth below ground level HSR 21.90 |
| 989 | N MANHOLE CHAMBERS Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening HSR 21.93 |
| 990 | BATHROOM ACCESSORIES Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 4. Rectangular shape 1500x450 mm HSR 22.210 |
| 991 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 992 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.4. Single Socket Type B 75mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 993 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 994 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24.1 |
| 995 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level HSR 6.24.2 |
| 996 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR 6.30.1 |
| 997 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR 6.30.3 |
| 998 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) HSR 6.30.4 |
| 999 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR 6.30.5 |
| 1000 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts HSR 6.30.6 |
| 1001 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases HSR 6.30.7 |
| 1002 | I CENTRING AND SHUTTERING (FORM WORK) Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1. Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) HSR 6.32 |
| 1003 | Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. HSR 4.16 |
| 1004 | J STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR 6.34 |
| 1005 | Earth Filling for buildings internal portion, Brickwork Below Plinth Level to retain Earthwork HSR |
| 1006 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. HSR 4.14 |
| 1007 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. HSR 4.33 |
| 1008 | C FIXING INCLUDING CARRIAGE Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge HSR 21.28 |
| 1009 | INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR 11.60 |
| 1010 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement mortar 1:6 (1 cement : 6 coarse sand) HSR 7.21 |
| 1011 | A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR 6.1 |
| 1012 | B DAMP-PROOF COURSE Providing and laying damp-proof course with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size) 2. 40 mm thick HSR 6.9 |
| 1013 | B DAMP-PROOF COURSE Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. HSR 6.10 |
| 1014 | F READY MIX CEMENT CONCRETE WITH FLYASH Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level HSR 6.24 |
| 1015 | I CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR 6.30.5 |
| 1016 | Schedule A By Mechanical Transport including loading, unloading and stacking 2. Earth HSR 3.1 |
| 1017 | Schedule A By Mechanical Transport including loading, unloading and stacking 2. Earth HSR 3.1 |
| 1018 | Schedule A By Mechanical Transport including loading, unloading and stacking 2. Earth HSR 3.1 |
| 1019 | Public Health misc. fittings for all buildings |
| 1020 | WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 1.2. Semi rigid pipe40 mm dia HSR 22.14 |
| 1021 | PTMT FITTINGS Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. HSR 22.118 |
| 1022 | PTMT FITTINGS Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 2. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. HSR 22.119 |
| 1023 | PTMT FITTINGS Providing and fixing PTMT grating of approved quality and colour. 1.1. Circular type 100 mm nominal dia HSR 22.123 |
| 1024 | PTMT FITTINGS Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. HSR 22.127 |
| 1025 | STONE WARE PIPES AND FITTINGS Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 3.1. 180x150 mm size P typeWith common burnt clay non-modular bricks of class designation 7.5 HSR 22.166 |
| 1026 | LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181 |
| 1027 | N MANHOLE CHAMBERS Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening HSR 21.93 |
| 1028 | HDPE pipes for Drainage Providing and Supplying of class SN 8 structured wall Polyethylene Piping system (Pipe with online/ offline coupler and elastomeric sealing ring) with non smooth external annular corrugated and smooth internal surface (double wall) for non-pressure underground sewerage and drainage application as confirm to IS 16098 (part II):2013 including transportation, frieght charges, inspection charges, loading, unloading, complete as specified and directed by Engineer In-Charge. 1. 250 mm Internal Diameter HSR 22.218 |
| 1029 | HDPE pipes for Drainage Lowering, Laying and jointing of class SN 8 structured wall (External Annular Corrugated and Smooth Internal Surface Polyethylene Piping and fitting with the help of coupler(online/ offline) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the spigot end, lowering the same into the trench, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient, depth and alignment, testing the water tightness of the joints, ensuring the continuity tests of specified pipe segment etc. complete as per drawing, specification and detailed engineering, including cartage of pipes and fitting etc. as per direction of Engineer-in-charge. 1. 1250 mm Internal Diameter HSR 22.219 |
| 1030 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 1031 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 1032 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 1033 | HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 ofE.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.4. Single Socket Type B 75mm o/d SWR UPVC pipe lines laid complete HSR 22.222 |
| 1034 | NS items |
| 1035 | Providing and fixing of SS 304 grade 1.2mm thick Wall hung Urinal of size (475mm H X 330 W X 230mm D) flush type and waste coupling of Required dia complete in all respect. Make- Silver Shine (Bluestar), Jayna, Neelkanth) |
| 1036 | PROVIDING AND FIXING OF 5MM THICK ACRYLIC SHEET COMPLETE IN ALL RESPECT |
| 1037 | Providing and fixing of SS 304 grade 1.2mm thick Wall hung Urinal of size (475mm H X 330 W X 230mm D) flush type and waste coupling of Required dia complete in all respect. Make- Silver Shine (Bluestar), Jayna, Neelkanth) |
| 1038 | PROVIDING AND FIXING OF 5MM THICK ACRYLIC SHEET COMPLETE IN ALL RESPECT |
| 1039 | Electrical Sub Component -Dietary Godown (HSR) |
| 1040 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1) |
| 1041 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.2) |
| 1042 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.3.6.3) |
| 1043 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) (HSR 23.3.6.5) |
| 1044 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.6) |
| 1045 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C (HSR 23.4.1.3) |
| 1046 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.3. Wiring in PVC conduit system for 3-pin5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C (HSR 23.4.4.3) |
| 1047 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3. Wiring in PVC conduit system for 3-pin15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C (HSR 23.4.5.3) |
| 1048 | EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. (HSR 24.1.1) |
| 1049 | EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2) |
| 1050 | EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. (HSR 24.1.7) |
| 1051 | EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.8) |
| 1052 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1) |
| 1053 | MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia (HSR 24.5.2.3) |
| 1054 | MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 90/75 mm outer dia/inner dia (HSR 24.5.2.4) |
| 1055 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2) |
| 1056 | FITTING AND ACCESSORIES 1.5. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type (HSR 23.8.1.5) |
| 1057 | FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. (HSR 23.8.1.12) |
| 1058 | FITTING AND ACCESSORIES 2.2. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 3 mm thick (HSR 23.8.2.2) |
| 1059 | FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. (HSR 23.8.4) |
| 1060 | FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data (HSR 23.8.10.1) |
| 1061 | FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7) |
| 1062 | FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type (HSR 23.8.11.8) |
| 1063 | FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate (HSR 23.8.11.10) |
| 1064 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA (HSR 23.22.1.9) |
| 1065 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.10. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 6 way ( 8 incoming 3phase*6 outgoing) (HSR 23.22.4.10) |
| 1066 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.11. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 8 way ( 8 incoming 3phase*8 outgoing) (HSR 23.22.4.11) |
| 1067 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1) |
| 1068 | MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire (HSR 23.23.8.1) |
| 1069 | SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. (HSR 23.26.1) |
| 1070 | CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) (HSR 20.71.1) |
| 1071 | CEILING FAN/ EXHAUST FAN Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. (HSR 20.72.) |
| 1072 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38. 35Sq mm 3.5 core (Arm.) (HSR 24.13.38) |
| 1073 | Electrical Sub Component- Female Barrack (HSR) |
| 1074 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1) |
| 1075 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm)(HSR 23.3.6.2) |
| 1076 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.3.6.3) |
| 1077 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) (HSR 23.3.6.5) |
| 1078 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm)(HSR 23.3.6.6) |
| 1079 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C (HSR 23.4.1.3) |
| 1080 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.3. Wiring in PVC conduit system for 3-pin5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C (HSR 23.4.4.3) |
| 1081 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3. Wiring in PVC conduit system for 3-pin15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C (HSR 23.4.5.3) |
| 1082 | EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. (HSR 24.1.1) |
| 1083 | EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2) |
| 1084 | EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. (HSR 24.1.3) |
| 1085 | EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. (HSR 24.1.5) |
| 1086 | EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. (HSR 24.1.7) |
| 1087 | EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.8) |
| 1088 | LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core (HSR 24.2.7.2) |
| 1089 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1) |
| 1090 | STREET LIGHT 5. Supply and erection of Single Phase weather proof M.S. box of size 20 cm x 15 cm x 10 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A Bakelite connector, 1 no. 6 amp SP MCB and 1 Nos. 16 amp. neutral links fixed on Bakelite sheet in the M.S. box including painting and necessary connections. (HSR 24.4.5) |
| 1091 | MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia (HSR 24.5.2.3) |
| 1092 | MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 90/75 mm outer dia/inner dia (HSR 24.5.2.4) |
| 1093 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2) |
| 1094 | FITTING AND ACCESSORIES 1.5. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type (HSR 23.8.1.5) |
| 1095 | FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. (HSR 23.8.1.12) |
| 1096 | FITTING AND ACCESSORIES 2.2. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 3 mm thick (HSR 23.8.2.2) |
| 1097 | FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. (HSR 23.8.4) |
| 1098 | FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data (HSR 23.8.10.1) |
| 1099 | FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7) |
| 1100 | FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type (HSR 23.8.11.8) |
| 1101 | FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate (HSR 23.8.11.10) |
| 1102 | FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type (HSR 23.8.11.11) |
| 1103 | Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required (HSR 23.20) |
| 1104 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA (HSR 23.22.1.9) |
| 1105 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1) |
| 1106 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE (HSR 23.22.5.3) |
| 1107 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE (HSR 23.22.5.8) |
| 1108 | MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire (HSR 23.23.8.1) |
| 1109 | MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required |(HSR 23.23.9) |
| 1110 | SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. (HSR 23.26.1) |
| 1111 | Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 3. M.S. pedestal of size 750 mm wide , 1200 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . (HSR 23.27) |
| 1112 | CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) (HSR 20.71.1) |
| 1113 | CEILING FAN/ EXHAUST FAN Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. (HSR 20.72) |
| 1114 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16Sq mm 4 core (Arm.) (HSR 24.13.24) |
| 1115 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38. 35Sq mm 3.5 core (Arm.) (HSR 24.13.38) |
| 1116 | Electrical Sub Component- Male Barrack Type-I (HSR) |
| 1117 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1) |
| 1118 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.2) |
| 1119 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm)(HSR 23.3.6.3) |
| 1120 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) (HSR 23.3.6.5) |
| 1121 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.6) |
| 1122 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C (HSR 23.4.1.3) |
| 1123 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.3. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C (HSR 23.4.4.3) |
| 1124 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3. Wiring in PVC conduit system for 3-pin15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C (HSR 23.4.5.3) |
| 1125 | 1 EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.(HSR 24.1.1) |
| 1126 | EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2) |
| 1127 | EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. (HSR 24.1.3) |
| 1128 | EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. (HSR 24.1.5) |
| 1129 | EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. (HSR 24.1.7) |
| 1130 | EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.8) |
| 1131 | LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core (HSR 24.2.7.2) |
| 1132 | LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm (HSR 24.2.8.4) |
| 1133 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1) |
| 1134 | STREET LIGHT 5. Supply and erection of Single Phase weather proof M.S. box of size 20 cm x 15 cm x 10 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A Bakelite connector, 1 no. 6 amp SP MCB and 1 Nos. 16 amp. neutral links fixed on Bakelite sheet in the M.S. box including painting and necessary connections. (HSR 24.4.5) |
| 1135 | MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia (HSR 24.5.2.3) |
| 1136 | MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 90/75 mm outer dia/inner dia (HSR 24.5.2.4) |
| 1137 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2) |
| 1138 | FITTING AND ACCESSORIES 1.5. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type (HSR 23.8.1.5) |
| 1139 | FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. (HSR 23.8.1.12) |
| 1140 | FITTING AND ACCESSORIES 2.2. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 3 mm thick (HSR 23.8.2.2) |
| 1141 | FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.(HSR 23.8.4) |
| 1142 | FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data (HSR 23.8.10.1) |
| 1143 | FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7) |
| 1144 | FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type (HSR 23.8.11.8) |
| 1145 | FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate (HSR 23.8.11.10) |
| 1146 | FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type (HSR 23.8.11.11) |
| 1147 | Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work. (HSR 23.9) |
| 1148 | Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required (HSR 23.20) |
| 1149 | Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required (HSR 23.21) |
| 1150 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA (HSR 23.22.1.9) |
| 1151 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1) |
| 1152 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE (HSR 23.22.5.3) |
| 1153 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE (HSR 23.22.5.8) |
| 1154 | MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire (HSR 23.23.8.1) |
| 1155 | MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required (HSR 23.23.9) |
| 1156 | SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. (HSR 23.26.1) |
| 1157 | Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 3. M.S. pedestal of size 750 mm wide , 1200 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . (HSR 23.27) |
| 1158 | CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) (HSR 20.71.1) |
| 1159 | CEILING FAN/ EXHAUST FAN Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. (HSR 20.72) |
| 1160 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16Sq mm 4 core (Arm.) (HSR 24.13.24) |
| 1161 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38. 35Sq mm 3.5 core (Arm.) (HSR 24.13.38) |
| 1162 | Electrical Sub Component- Male Barrack type -II (HSR) |
| 1163 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1) |
| 1164 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.2) |
| 1165 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.3.6.3) |
| 1166 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) (HSR 23.3.6.5) |
| 1167 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.6) |
| 1168 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C (HSR 23.4.1.3) |
| 1169 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 3.3. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group C (HSR 23.4.3.3) |
| 1170 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3. Wiring in PVC conduit system for 3-pin15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C (HSR 23.4.5.3) |
| 1171 | EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. (HSR 24.1.1) |
| 1172 | EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2) |
| 1173 | EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. (HSR 24.1.3) |
| 1174 | EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. (HSR 24.1.5) |
| 1175 | EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. (HSR 24.1.7) |
| 1176 | EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.8) |
| 1177 | EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. (HSR 24.1.13) |
| 1178 | LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core (HSR 24.2.7.3) |
| 1179 | LT CABLE 8.5. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 25 sqmm (HSR 24.2.8.5) |
| 1180 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1) |
| 1181 | STREET LIGHT 5. Supply and erection of Single Phase weather proof M.S. box of size 20 cm x 15 cm x 10 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A Bakelite connector, 1 no. 6 amp SP MCB and 1 Nos. 16 amp. neutral links fixed on Bakelite sheet in the M.S. box including painting and necessary connections. (HSR 24.4.5) |
| 1182 | MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia (HSR 24.5.2.3) |
| 1183 | MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 90/75 mm outer dia/inner dia (HSR 24.5.2.4) |
| 1184 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2) |
| 1185 | FITTING AND ACCESSORIES 1.5. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type (HSR 23.8.1.5) |
| 1186 | FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. (HSR 23.8.1.12) |
| 1187 | FITTING AND ACCESSORIES 2.2. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 3 mm thick (HSR 23.8.2.2) |
| 1188 | FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. (HSR 23.8.4) |
| 1189 | FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7) |
| 1190 | FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type (HSR 23.8.11.8) |
| 1191 | FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate (HSR 23.8.11.10) |
| 1192 | Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required (HSR 23.20.) |
| 1193 | Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required (HSR 23.21) |
| 1194 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA (HSR 23.22.1.9) |
| 1195 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) (HSR 23.22.4.5) |
| 1196 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.6. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing) (HSR 23.22.4.6) |
| 1197 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.9. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 4 way ( 8 incoming and 3phase*4 outgoing) (HSR 23.22.4.9) |
| 1198 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1) |
| 1199 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.5. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs TRIPLE POLE (HSR 23.22.5.5) |
| 1200 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.6. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs TRIPLE POLE (HSR 23.22.5.6) |
| 1201 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.7. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs FOUR POLE (HSR 23.22.5.7) |
| 1202 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE (HSR 23.22.5.8) |
| 1203 | MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire (HSR 23.23.8.1) |
| 1204 | SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. (HSR 23.26.1) |
| 1205 | CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) (HSR 20.71.1) |
| 1206 | CEILING FAN/ EXHAUST FAN Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. (HSR 20.72) |
| 1207 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25Sq mm 4 core (Arm.) (HSR 24.13.32) |
| 1208 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38. 35Sq mm 3.5 core (Arm.) (HSR 24.13.38) |
| 1209 | ElectricalSub Component- Hospital block (HSR) |
| 1210 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1) |
| 1211 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.2) |
| 1212 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.3.6.3) |
| 1213 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) (HSR 23.3.6.5) |
| 1214 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.6) |
| 1215 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C (HSR 23.4.1.3) |
| 1216 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 2.3. Wiring for Twin control light point with 2 nos, 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C (HSR 23.4.2.3) |
| 1217 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.3. Wiring in PVC conduit system for 3-pin5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C (HSR 23.4.4.3) |
| 1218 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3. Wiring in PVC conduit system for 3-pin15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C (HSR 23.4.5.3) |
| 1219 | EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. (HSR 24.1.1) |
| 1220 | EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2) |
| 1221 | EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. (HSR 24.1.3) |
| 1222 | EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. (HSR 24.1.5) |
| 1223 | EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. (HSR 24.1.7) |
| 1224 | EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.8) |
| 1225 | EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. (HSR 24.1.13) |
| 1226 | LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core (HSR 24.2.7.2) |
| 1227 | LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm (HSR 24.2.8.4) |
| 1228 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1) |
| 1229 | MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia (HSR 24.5.2.3) |
| 1230 | MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 90/75 mm outer dia/inner dia (HSR 24.5.2.4) |
| 1231 | MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 120/105 mm outer dia/ inner dia (HSR 24.5.2.5) |
| 1232 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2) |
| 1233 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.3. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 32 mm dia. (HSR 23.7.6.3) |
| 1234 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia. (HSR 23.7.6.4) |
| 1235 | FITTING AND ACCESSORIES 1.5. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type (HSR 23.8.1.5) |
| 1236 | FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. (HSR 23.8.1.12) |
| 1237 | FITTING AND ACCESSORIES 2.2. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 3 mm thick (HSR 23.8.2.2) |
| 1238 | FITTING AND ACCESSORIES 9. Supply and erection direct reading LCD Display Digital Ammetre/Voltmetre ( without CT or PT ) on wall/existing penal complete in all respect with necessary connections (HSR 23.8.9) |
| 1239 | FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data (HSR 23.8.10.1) |
| 1240 | FITTING AND ACCESSORIES 10.4. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules (HSR 23.8.10.4) |
| 1241 | FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch (HSR 23.8.11.1) |
| 1242 | FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket (HSR 23.8.11.4) |
| 1243 | FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7) |
| 1244 | FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type (HSR 23.8.11.8) |
| 1245 | FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate (HSR 23.8.11.10) |
| 1246 | FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type (HSR 23.8.11.11) |
| 1247 | Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work. (HSR 23.9) |
| 1248 | Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required (HSR 23.20) |
| 1249 | Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required (HSR 23.21) |
| 1250 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA (HSR 23.22.1.9) |
| 1251 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA (HSR 23.22.1.11) |
| 1252 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP (HSR 23.22.2.1) |
| 1253 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.2. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. S.P.N. or DP enclosure suitable for DP MCB (HSR 23.22.3.2) |
| 1254 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) (HSR 23.22.4.2) |
| 1255 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.9. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 4 way ( 8 incoming and 3phase*4 outgoing) (HSR 23.22.4.9) |
| 1256 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.10. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 6 way ( 8 incoming 3phase*6 outgoing) (HSR 23.22.4.10) |
| 1257 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1) |
| 1258 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE (HSR 23.22.5.3) |
| 1259 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.6. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs TRIPLE POLE (HSR 23.22.5.6) |
| 1260 | MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire (HSR 23.23.8.1) |
| 1261 | MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required (HSR 23.23.9) |
| 1262 | MS STAND, BUS BAR CHAMBER AND PANELS 4.2. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 8 way 250 amp. (HSR 23.24.4.2) |
| 1263 | SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. (HSR 23.26.1) |
| 1264 | CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) (HSR 20.71.1) |
| 1265 | CEILING FAN/ EXHAUST FAN Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. (HSR 20.72) |
| 1266 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16Sq mm 4 core (Arm.) (HSR 24.13.24) |
| 1267 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38. 35Sq mm 3.5 core (Arm.) (HSR 24.13.38) |
| 1268 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 56. 70Sq mm 4 core (Arm.) (HSR 24.13.56) |
| 1269 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 62. 95Sq mm 3.5 core (Arm.) (HSR 24.13.62) |
| 1270 | Electrical Sub Component- Control Room (HSR) |
| 1271 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1) |
| 1272 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.2) |
| 1273 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.3.6.3) |
| 1274 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) ((HSR 23.3.6.5)) |
| 1275 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm)(HSR 23.3.6.6) |
| 1276 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C (HSR 23.4.1.3) |
| 1277 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 2.3. Wiring for Twin control light point with 2 nos, 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C (HSR 23.4.2.3) |
| 1278 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.3. Wiring in PVC conduit system for 3-pin5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C (HSR 23.4.4.3) |
| 1279 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3. Wiring in PVC conduit system for 3-pin15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C (HSR 23.4.5.3) |
| 1280 | EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. (HSR 24.1.1) |
| 1281 | EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2) |
| 1282 | EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. (HSR 24.1.5) |
| 1283 | EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. (HSR 24.1.7) |
| 1284 | EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.8) |
| 1285 | EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.11) |
| 1286 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1) |
| 1287 | MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 90/75 mm outer dia/inner dia (HSR 24.5.2.4) |
| 1288 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2) |
| 1289 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia. (HSR 23.7.6.4) |
| 1290 | FITTING AND ACCESSORIES 1.5. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type (HSR 23.8.1.5) |
| 1291 | FITTING AND ACCESSORIES 1.6. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Call bell 220/230 volts musical type (HSR 23.8.1.6) |
| 1292 | FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. (HSR 23.8.1.12) |
| 1293 | FITTING AND ACCESSORIES 2.2. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 3 mm thick (HSR 23.8.2.2) |
| 1294 | FITTING AND ACCESSORIES 9. Supply and erection direct reading LCD Display Digital Ammetre/Voltmetre ( without CT or PT ) on wall/existing penal complete in all respect with necessary connections (HSR 23.8.9) |
| 1295 | FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data (HSR 23.8.10.1) |
| 1296 | FITTING AND ACCESSORIES 10.4. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules (HSR 23.8.10.4) |
| 1297 | FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch (HSR 23.8.11.1) |
| 1298 | FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket (HSR 23.8.11.4) |
| 1299 | FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7) |
| 1300 | FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type (HSR 23.8.11.8) |
| 1301 | FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate (HSR 23.8.11.10) |
| 1302 | FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type (HSR 23.8.11.11) |
| 1303 | Erection of cabin fan complete with necessary earthling including carriage from PWD store to the site of work. (HSR 23.10) |
| 1304 | Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required (HSR 23.20) |
| 1305 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA (HSR 23.22.1.9) |
| 1306 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.10. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 6 way ( 8 incoming 3phase*6 outgoing) (HSR 23.22.4.10) |
| 1307 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1) |
| 1308 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE (HSR 23.22.5.8) |
| 1309 | MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire (HSR 23.23.8.1) |
| 1310 | MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required (HSR 23.23.9) |
| 1311 | SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. (HSR 23.26.1) |
| 1312 | CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) (HSR 20.71.1) |
| 1313 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 54. 70Sq mm 3.5 core (Arm.) (HSR 24.13.54) |
| 1314 | Electrical Sub Component- Cook House (HSR) |
| 1315 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1) |
| 1316 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.2) |
| 1317 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.3.6.3) |
| 1318 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) (HSR 23.3.6.5) |
| 1319 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.6) |
| 1320 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C (HSR 23.4.1.3) |
| 1321 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.3. Wiring in PVC conduit system for 3-pin5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C (HSR 23.4.4.3) |
| 1322 | EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. (HSR 24.1.3) |
| 1323 | EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. (HSR 24.1.5) |
| 1324 | EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. (HSR 24.1.7) |
| 1325 | EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.8) |
| 1326 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1) |
| 1327 | MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia (HSR 24.5.2.3) |
| 1328 | MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 90/75 mm outer dia/inner dia (HSR 24.5.2.4) |
| 1329 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2) |
| 1330 | FITTING AND ACCESSORIES 1.5. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type (HSR 23.8.1.5) |
| 1331 | FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. (HSR 23.8.1.12) |
| 1332 | FITTING AND ACCESSORIES 2.2. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 3 mm thick (HSR 23.8.2.2) |
| 1333 | FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. (HSR 23.8.4) |
| 1334 | FITTING AND ACCESSORIES 9. Supply and erection direct reading LCD Display Digital Ammetre/Voltmetre ( without CT or PT ) on wall/existing penal complete in all respect with necessary connections (HSR 23.8.9) |
| 1335 | FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data (HSR 23.8.11.10.1) |
| 1336 | FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7) |
| 1337 | FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type(HSR 23.8.11.8) |
| 1338 | FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate (HSR 23.8.11.10) |
| 1339 | Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work. (HSR 23.9) |
| 1340 | Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required (HSR 23.20) |
| 1341 | Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required (HSR 23.21) |
| 1342 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA (HSR 23.22.1.9) |
| 1343 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1) |
| 1344 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE (HSR 23.22.5.3) |
| 1345 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE (HSR 23.22.5.8) |
| 1346 | MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire (HSR 23.23.8.1) |
| 1347 | SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. (HSR 23.26.1) |
| 1348 | Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 3. M.S. pedestal of size 750 mm wide , 1200 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . (HSR 23.27) |
| 1349 | CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) (HSR 20.71.1) |
| 1350 | CEILING FAN/ EXHAUST FAN Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. (HSR 20.72) |
| 1351 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38. 35Sq mm 3.5 core (Arm.) (HSR 24.13.38) |
| 1352 | Electrical Sub Component- Special Security Enclosures (3nos.) (HSR) |
| 1353 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1) |
| 1354 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.2) |
| 1355 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.3.6.3) |
| 1356 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) (HSR 23.3.6.5) |
| 1357 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.6.) |
| 1358 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C (HSR 23.4.1.3)\ |
| 1359 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3. Wiring in PVC conduit system for 3-pin15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C (HSR 23.4.5.3) |
| 1360 | EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. (HSR 24.1.1) |
| 1361 | EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2) |
| 1362 | EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. (HSR 24.1.7) |
| 1363 | EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.8) |
| 1364 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1) |
| 1365 | MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia (HSR 24.5.2.3) |
| 1366 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2) |
| 1367 | FITTING AND ACCESSORIES 2.2. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 3 mm thick (HSR 23.8.2.2) |
| 1368 | FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. (HSR 23.8.4) |
| 1369 | FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7) |
| 1370 | FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate (HSR 23.8.11.10) |
| 1371 | Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required (HSR 23.20.) |
| 1372 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA (HSR 23.22.1.9) |
| 1373 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1) |
| 1374 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.5. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs TRIPLE POLE (HSR 23.22.5.5) |
| 1375 | CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) (HSR 20.71.1) |
| 1376 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 30. 25Sq mm 3.5 core (Arm.) (HSR 24.13.30) |
| 1377 | Electrical Sub Component- Factory Shed / Correctional Compound (HSR) |
| 1378 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1) |
| 1379 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Vo lts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.2) |
| 1380 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.3.6.3.) |
| 1381 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) (HSR 23.3.6.5) |
| 1382 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.6) |
| 1383 | COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.8. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 4 Sqmm(1/2.24mm) (HSR 23.3.6.8) |
| 1384 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B (HSR 23.4.1.2) |
| 1385 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 2.2. Wiring for Twin control light point with 2 nos, 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B (HSR 23.4.2.2) |
| 1386 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 3.2. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group B (HSR 23.4.3.2) |
| 1387 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.2. Wiring in PVC conduit system for 3-pin5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B (HSR 23.4.4.2) |
| 1388 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.2. Wiring in PVC conduit system for 3-pin15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B (HSR 23.4.5.2) |
| 1389 | EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. (HSR 24.1.1) |
| 1390 | EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2) |
| 1391 | EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. (HSR 24.1.3) |
| 1392 | EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. (HSR 24.1.5) |
| 1393 | EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. (HSR 24.1.7) |
| 1394 | EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.8) |
| 1395 | EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.11) |
| 1396 | EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. (HSR 24.1.13) |
| 1397 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1) |
| 1398 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.5.6.3) |
| 1399 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.4. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) (HSR 23.5.6.4) |
| 1400 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.5. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) (HSR 23.5.6.5) |
| 1401 | MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia (HSR 24.5.2.3) |
| 1402 | MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 120/105 mm outer dia/ inner dia (HSR 24.5.2.5) |
| 1403 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2) |
| 1404 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia. (HSR 23.7.6.4) |
| 1405 | FITTING AND ACCESSORIES 1.5. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type (HSR 23.8.1.5) |
| 1406 | FITTING AND ACCESSORIES 1.6. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Call bell 220/230 volts musical type (HSR 23.8.1.6) |
| 1407 | FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. (HSR 23.8.1.12) |
| 1408 | FITTING AND ACCESSORIES 2.2. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 3 mm thick (HSR 23.8.2.2) |
| 1409 | FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. (HSR 23.8.4) |
| 1410 | FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data (hSR 23.8.10.1) |
| 1411 | FITTING AND ACCESSORIES 10.4. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules (HSR 23.8.10.4) |
| 1412 | FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch (HSR 23.8.11.1) |
| 1413 | FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket (HSR 23.8.11.4) |
| 1414 | FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7) |
| 1415 | FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type (HSR 23.8.11.8) |
| 1416 | FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate (HSR 23.8.11.10) |
| 1417 | FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type (HSR 23.8.11.11) |
| 1418 | Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required (HSR 23.20) |
| 1419 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA (HSR 23.22.1.10) |
| 1420 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA (HSR 23.22.1.11) |
| 1421 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.2. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. S.P.N. or DP enclosure suitable for DP MCB (HSR 23.22.3.2) |
| 1422 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.3. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. TPN enclosure suitable for TP , TPN or FP MCB (HSR 23.22.3.3) |
| 1423 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.9. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 4 way ( 8 incoming and 3phase*4 outgoing) (HSR 23.22.4.9) |
| 1424 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.10. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 6 way ( 8 incoming 3phase*6 outgoing) (HSR 23.22.4.10) |
| 1425 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1) |
| 1426 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE (HSR 23.22.5.3) |
| 1427 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.5. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs TRIPLE POLE (HSR 23.22.5.5) |
| 1428 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.7. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs FOUR POLE (HSR 23.22.5.7) |
| 1429 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE (HSR 23.22.5.8) |
| 1430 | MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire (HSR 23.23.8.1) |
| 1431 | MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required (HSR 23.23.9.) |
| 1432 | MS STAND, BUS BAR CHAMBER AND PANELS 4.1. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 4 way 250 amp. (HSR 23.24.4.1) |
| 1433 | CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) (HSR 20.71.1) |
| 1434 | CEILING FAN/ EXHAUST FAN Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. (HSR 20.72) |
| 1435 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16Sq mm 4 core (Arm.) (HSR 24.13.24) |
| 1436 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 29. 25Sq mm 3.5 core (UnArm.) (HSR 24.13.29) |
| 1437 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25Sq mm 4 core (Arm.) (HSR 24.13.32) |
| 1438 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 45. 50Sq mm 3.5 core (UnArm.) (HSR 24.13.45) |
| 1439 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 46. 50Sq mm 3.5core (Arm.) (HSR 24.13.46) |
| 1440 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 62. 95Sq mm 3.5 core (Arm.) (HSR 24.13.62) |
| 1441 | Electrical Sub Component- Watch Tower |
| 1442 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A (HSR 23.4.1.1) |
| 1443 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 5.1. Wiring in existingconduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch etc complete as required Group A (HSR 23.5.5.1) |
| 1444 | STREET LIGHT 2.1. Supply and erection of GI bracket made of 32 mm dia medium class GI pipe, having 15 deg angle from horizontal, suitable for fixing on top of Street Light pole 60 cm long. (HSR 24.4.2.1) |
| 1445 | STREET LIGHT 5. Supply and erection of Single Phase weather proof M.S. box of size 20 cm x 15 cm x 10 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A Bakelite connector, 1 no. 6 amp SP MCB and 1 Nos. 16 amp. neutral links fixed on Bakelite sheet in the M.S. box including painting and necessary connections. |(HSR 24.4.5) |
| 1446 | MISCELLANEOUS ITEMS 2.1. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 40/32 mm outer dia/ inner dia (HSr 24.5.2.1) |
| 1447 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2) |
| 1448 | FITTING AND ACCESSORIES 10.6. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 12 Modules (HSR 23.8.10.6) |
| 1449 | FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch (HSR 23.8.11.1) |
| 1450 | FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket (HSR 23.8.11.4) |
| 1451 | Erection of cabin fan complete with necessary earthling including carriage from PWD store to the site of work. (HSR 23.10) |
| 1452 | Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required (HSR 23.20.) |
| 1453 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.1. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 4 way ( 2 incoming and 2 outgoing) (HSR 23.22.4.1) |
| 1454 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1) |
| 1455 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE (HSR 23.22.5.3) |
| 1456 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 14. 10Sq mm 2core (Arm.) (HSR 24.13.14) |
| 1457 | Electrical Sub Component- Fire Fighting System (HSR) |
| 1458 | Central Air Conditioning : Low side Items Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 6. 100mm dia. (HSR 25.3.6) |
| 1459 | Central Air Conditioning : Low side Items Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 7. 80mm dia. (HSR 25.3.7) |
| 1460 | Central Air Conditioning : Low side Items Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 9. 50 mm dia. (HSR 25.3.9) |
| 1461 | Central Air Conditioning : Low side Items Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 4. 100mm dia. (HSr 25.4.4) |
| 1462 | SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia). (HSR 23.26.4) |
| 1463 | LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (HSR 22.181) |
| 1464 | Electrical Sub Component- Dietary Godown (NS) |
| 1465 | Supply of Integrated LED tube light = 18 watt, Rated Life: = 25,000 burning hours , 4 feet long, minimum lumen efficiency 100 lm/watti.e. 1800 lumens for 18 watt light, CRI = 80, Color Temp. (CCT) =4000 K- Natural White, Polycarbonate body, minimum IP20, Power Factor: = 0.9 , Driver Type: Constant current LED driver (inbuilt), Surge Protection: 2.5–4 kV, BIS certified, conforming to IS 10322 complete with screw- nut as required for erection. |
| 1466 | Supply, installation, testing and commissioning of LED flood light = 50 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor =0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection =4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect |
| 1467 | Supply of 15` exhaust fan (375mm)metal body, minimum 900 RPM Heavy duty with louver shutter having air delivery not less than 2000 CMH and single phase power supply, 230V, 50 Hz AC having high grade aluminum / FRP/Powder coated steel blade/ body/louver shutter, power consumption= min. 135 w , motor, IP44 or better protection including nut , bolts complete in all respect. Make-Crompton or as per approved brand list of HPHC. |
| 1468 | S/E of min. 2200 VA (volt- amp) or above rating double battery Sine wave inverter along with built in input MCB for short -circuit and overload protection instead of just a glass fuse having CCCV or 3-stage charging, Input Voltage Range: 140V – 300V AC, Output Voltage: 220–240V AC ±10% , Frequency: 50 Hz ± 0.5 Hz , Transfer Time: (10 ms (UPS mode), LED/LCD display, automatic changeover, and complete protections including overload, short circuit, deep discharge, and overcharge protection, conforming to IS 16242/IEC 62040, BIS certified, Efficiency: =85–95% and THD (Total Harmonic Distortion): (3–5% having warranty of minimum 24 months with 2 nos 12/24V tubular type batteries of rating 200 Ah (Amp – hours ) each 48 months warranty including MS stand / trolly complete in all respect. |
| 1469 | Electrical Sub Component- Female Barrack (NS) |
| 1470 | S/E of 2200 VA (volt- amp) or above rating double battery Sine wave inverter along with built in input MCB for short -circuit and overload protection instead of just a glass fuse having CCCV or 3-stage charging and Total harmonic Distortion (3% having warranty of minimum 24 months with 2 nos tubular type batteries of rating 200 Ah (Amp – hours ) each 48 months warranty including MS stand/ trolly complete in all respect. |
| 1471 | Supply of Integrated LED tube light = 18 watt, Rated Life: = 25,000 burning hours , 4 feet long, minimum lumen efficiency 100 lm/watti.e. 1800 lumens for 18 watt light, CRI = 80, Color Temp. (CCT) =4000 K- Natural White, Polycarbonate body, minimum IP20, Power Factor: = 0.9 , Driver Type: Constant current LED driver (inbuilt), Surge Protection: 2.5–4 kV, BIS certified, conforming to IS 10322 complete with screw- nut as required for erection. |
| 1472 | Supply and erection of LED flood light 100 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor=0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection =4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect |
| 1473 | SITC of 50 LPH (50 ltr per hour) capacity RO, Commercial type including Pre-filters complete in all respect with making necessary connections, should be suitable for raw water TDS upto 2000 ppm, the water should be filtered with PH value (range minimum 6.5 to maximum 8.0), TDS should be less than 100 ppm, recovery should be greater than 40%, and work shall be done as per entire satisfaction of Engineer-in-charge. |
| 1474 | Supply of 15` exhaust fan (375mm)metal body, minimum 900 RPM Heavy duty with louver shutter having air delivery not less than 2000 CMH and single phase power supply, 230V, 50 Hz AC having high grade aluminum / FRP/Powder coated steel blade/ body/louver shutter, power consumption= min. 135 w , motor, IP44 or better protection including nut , bolts complete in all respect. Make-Crompton or as per approved brand list of HPHC. |
| 1475 | Supply, installation, testing and commissioning of 4 kVA automatic voltage stabilizer, single phase, having input voltage range 170–280V AC (or wider), output 220–240V AC ±3%, Relay type, frequency 50 Hz ± 5%, efficiency =95%, copper wound transformer, with digital display, fully automatic operation, and protections including high/low voltage cut-off, overload, short circuit and thermal protection, conforming to relevant IS standards and BIS certified. complete in all respect. Make -Microtek, Livguard, Crompton. |
| 1476 | Supply of 12 watt LED round shape downlight offering high brightness (lumens efficiency ) 100 lumnes/watt) and long life span - 25000 hours, Beam angle 120° constant current drive, operate on 80V-300V A.C and made by polycarbonate material complete in all respect. Make as per approved brand list of HPHC. |
| 1477 | SITC of 150 ltr capacity water cooler having fully stainless steel corrosion resistance (grade SS304) body with puff insulation, 150/150 ltr i.e. 150 ltr per hour cooling and 150 ltr water storage capacity, Suitable for operation at ambient temp. upto 45 °C and inlet water temp. upto 30 °C, capable of delivering chilled water at 7 -12 °C , PUF insulation of min. 40 mm thickness, R134a refrigerant type, water tank sheet thickness )= 0.6 mm, Cooler Cabinet sheet thickness: 0.8mm (min), Water tank cover and lid bottom sheet material: High Impact Polystyrene (HIP) and Thickness:1.5mm (min) , Number of faucet-02, Two drainpipes shall be metallic or PVC (Poly Vinyl Chloride) , Plastic used in storage tank or in any part coming in contact with water shall be of food grade. Warranty on machine: 2 years. Warranty on compressor- 5 year, BIS Certification as per IS-1475 (Latest) complete in all respect with making necessary connections and work shall be done as per entire satisfaction of Engineer-in-charge. |
| 1478 | Supply, installation, testing and commissioning of LED flood light 50 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor )0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection )4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect |
| 1479 | S/E of min. 2200 VA (volt- amp) or above rating double battery Sine wave inverter along with built in input MCB for short -circuit and overload protection instead of just a glass fuse having CCCV or 3-stage charging, Input Voltage Range: 140V – 300V AC, Output Voltage: 220–240V AC ±10% , Frequency: 50 Hz ± 0.5 Hz , Transfer Time: (10 ms (UPS mode), LED/LCD display, automatic changeover, and complete protections including overload, short circuit, deep discharge, and overcharge protection, conforming to IS 16242/IEC 62040, BIS certified, Efficiency: =85–95% and THD (Total Harmonic Distortion): (3–5% having warranty of minimum 24 months with 2 nos 12/24V tubular type batteries of rating 200 Ah (Amp – hours ) each 48 months warranty including MS stand / trolly complete in all respect. |
| 1480 | Electrical Sub Component- Male Barrack Type-I (NS) |
| 1481 | Supply of Integrated LED tube light = 18 watt, Rated Life: = 25,000 burning hours , 4 feet long, minimum lumen efficiency 100 lm/watti.e. 1800 lumens for 18 watt light, CRI = 80, Color Temp. (CCT) =4000 K- Natural White, Polycarbonate body, minimum IP20, Power Factor: = 0.9 , Driver Type: Constant current LED driver (inbuilt), Surge Protection: 2.5–4 kV, BIS certified, conforming to IS 10322 complete with screw- nut as required for erection. |
| 1482 | Supply and erection of LED flood light 100 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor=0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection =4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect |
| 1483 | SITC of 50 LPH (50 ltr per hour) capacity RO, Commercial type including Pre-filters complete in all respect with making necessary connections, should be suitable for raw water TDS upto 2000 ppm, the water should be filtered with PH value (range minimum 6.5 to maximum 8.0), TDS should be less than 100 ppm, recovery should be greater than 40%, and work shall be done as per entire satisfaction of Engineer-in-charge. |
| 1484 | Supply of 15` exhaust fan (375mm)metal body, minimum 900 RPM Heavy duty with louver shutter having air delivery not less than 2000 CMH and single phase power supply, 230V, 50 Hz AC having high grade aluminum / FRP/Powder coated steel blade/ body/louver shutter, power consumption= min. 135 w , motor, IP44 or better protection including nut , bolts complete in all respect. Make-Crompton or as per approved brand list of HPHC. |
| 1485 | Supply, installation, testing and commissioning of 4 kVA automatic voltage stabilizer, single phase, having input voltage range 170–280V AC (or wider), output 220–240V AC ±3%, Relay type, frequency 50 Hz ± 5%, efficiency =95%, copper wound transformer, with digital display, fully automatic operation, and protections including high/low voltage cut-off, overload, short circuit and thermal protection, conforming to relevant IS standards and BIS certified. complete in all respect. Make -Microtek, Livguard, Crompton. |
| 1486 | Supply of 12 watt LED round shape downlight offering high brightness (lumens efficiency ) 100 lumnes/watt) and long life span - 25000 hours, Beam angle 120° constant current drive, operate on 80V-300V A.C and made by polycarbonate material complete in all respect. Make as per approved brand list of HPHC. |
| 1487 | SITC of 150 ltr capacity water cooler having fully stainless steel corrosion resistance (grade SS304) body with puff insulation, 150/150 ltr i.e. 150 ltr per hour cooling and 150 ltr water storage capacity, Suitable for operation at ambient temp. upto 45 °C and inlet water temp. upto 30 °C, capable of delivering chilled water at 7 -12 °C , PUF insulation of min. 40 mm thickness, R134a refrigerant type, water tank sheet thickness )= 0.6 mm, Cooler Cabinet sheet thickness: 0.8mm (min), Water tank cover and lid bottom sheet material: High Impact Polystyrene (HIP) and Thickness:1.5mm (min) , Number of faucet-02, Two drainpipes shall be metallic or PVC (Poly Vinyl Chloride) , Plastic used in storage tank or in any part coming in contact with water shall be of food grade. Warranty on machine: 2 years. Warranty on compressor- 5 year, BIS Certification as per IS-1475 (Latest) complete in all respect with making necessary connections and work shall be done as per entire satisfaction of Engineer-in-charge. |
| 1488 | Supply, installation, testing and commissioning of LED flood light 50 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor )0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection )4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect |
| 1489 | S/E of min. 2200 VA (volt- amp) or above rating double battery Sine wave inverter along with built in input MCB for short -circuit and overload protection instead of just a glass fuse having CCCV or 3-stage charging, Input Voltage Range: 140V – 300V AC, Output Voltage: 220–240V AC ±10% , Frequency: 50 Hz ± 0.5 Hz , Transfer Time: (10 ms (UPS mode), LED/LCD display, automatic changeover, and complete protections including overload, short circuit, deep discharge, and overcharge protection, conforming to IS 16242/IEC 62040, BIS certified, Efficiency: =85–95% and THD (Total Harmonic Distortion): (3–5% having warranty of minimum 24 months with 2 nos 12/24V tubular type batteries of rating 200 Ah (Amp – hours ) each 48 months warranty including MS stand / trolly complete in all respect. |
| 1490 | Electrical Sub Component- Male Barrack type -II (NS) |
| 1491 | Supply of Integrated LED tube light = 18 watt, Rated Life: = 25,000 burning hours , 4 feet long, minimum lumen efficiency 100 lm/watti.e. 1800 lumens for 18 watt light, CRI = 80, Color Temp. (CCT) =4000 K- Natural White, Polycarbonate body, minimum IP20, Power Factor: = 0.9 , Driver Type: Constant current LED driver (inbuilt), Surge Protection: 2.5–4 kV, BIS certified, conforming to IS 10322 complete with screw- nut as required for erection. |
| 1492 | Supply and erection of LED flood light 100 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor=0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection =4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect |
| 1493 | SITC of 50 LPH (50 ltr per hour) capacity RO, Commercial type including Pre-filters complete in all respect with making necessary connections, should be suitable for raw water TDS upto 2000 ppm, the water should be filtered with PH value (range minimum 6.5 to maximum 8.0), TDS should be less than 100 ppm, recovery should be greater than 40%, and work shall be done as per entire satisfaction of Engineer-in-charge. |
| 1494 | Supply of 15` exhaust fan (375mm)metal body, minimum 900 RPM Heavy duty with louver shutter having air delivery not less than 2000 CMH and single phase power supply, 230V, 50 Hz AC having high grade aluminum / FRP/Powder coated steel blade/ body/louver shutter, power consumption= min. 135 w , motor, IP44 or better protection including nut , bolts complete in all respect. Make-Crompton or as per approved brand list of HPHC. |
| 1495 | Supply, installation, testing and commissioning of 4 kVA automatic voltage stabilizer, single phase, having input voltage range 170–280V AC (or wider), output 220–240V AC ±3%, Relay type, frequency 50 Hz ± 5%, efficiency =95%, copper wound transformer, with digital display, fully automatic operation, and protections including high/low voltage cut-off, overload, short circuit and thermal protection, conforming to relevant IS standards and BIS certified. complete in all respect. Make -Microtek, Livguard, Crompton. |
| 1496 | Supply of 12 watt LED round shape downlight offering high brightness (lumens efficiency ) 100 lumnes/watt) and long life span - 25000 hours, Beam angle 120° constant current drive, operate on 80V-300V A.C and made by polycarbonate material complete in all respect. Make as per approved brand list of HPHC. |
| 1497 | SITC of 150 ltr capacity water cooler having fully stainless steel corrosion resistance (grade SS304) body with puff insulation, 150/150 ltr i.e. 150 ltr per hour cooling and 150 ltr water storage capacity, Suitable for operation at ambient temp. upto 45 °C and inlet water temp. upto 30 °C, capable of delivering chilled water at 7 -12 °C , PUF insulation of min. 40 mm thickness, R134a refrigerant type, water tank sheet thickness )= 0.6 mm, Cooler Cabinet sheet thickness: 0.8mm (min), Water tank cover and lid bottom sheet material: High Impact Polystyrene (HIP) and Thickness:1.5mm (min) , Number of faucet-02, Two drainpipes shall be metallic or PVC (Poly Vinyl Chloride) , Plastic used in storage tank or in any part coming in contact with water shall be of food grade. Warranty on machine: 2 years. Warranty on compressor- 5 year, BIS Certification as per IS-1475 (Latest) complete in all respect with making necessary connections and work shall be done as per entire satisfaction of Engineer-in-charge. |
| 1498 | Supply, installation, testing and commissioning of LED flood light 50 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor )0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection )4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect |
| 1499 | S/E of min. 2200 VA (volt- amp) or above rating double battery Sine wave inverter along with built in input MCB for short -circuit and overload protection instead of just a glass fuse having CCCV or 3-stage charging, Input Voltage Range: 140V – 300V AC, Output Voltage: 220–240V AC ±10% , Frequency: 50 Hz ± 0.5 Hz , Transfer Time: (10 ms (UPS mode), LED/LCD display, automatic changeover, and complete protections including overload, short circuit, deep discharge, and overcharge protection, conforming to IS 16242/IEC 62040, BIS certified, Efficiency: =85–95% and THD (Total Harmonic Distortion): (3–5% having warranty of minimum 24 months with 2 nos 12/24V tubular type batteries of rating 200 Ah (Amp – hours ) each 48 months warranty including MS stand / trolly complete in all respect. |
| 1500 | Electrical Sub Component- Hospital block (NS) |
| 1501 | Supply of Integrated LED tube light = 18 watt, Rated Life: = 25,000 burning hours , 4 feet long, minimum lumen efficiency 100 lm/watti.e. 1800 lumens for 18 watt light, CRI = 80, Color Temp. (CCT) =4000 K- Natural White, Polycarbonate body, minimum IP20, Power Factor: = 0.9 , Driver Type: Constant current LED driver (inbuilt), Surge Protection: 2.5–4 kV, BIS certified, conforming to IS 10322 complete with screw- nut as required for erection. |
| 1502 | Supply of 2`×2` (600×600 mm) LED panel light fitting of min. 32 watt, integrated type, having, efficacy =100 lm/W, CRI =80, CCT 4000K/6500K as required, Polycarbonate body, minimum IP20, Power Factor: = 0.9 min, THD =10%, glare-free diffuser with UGR (19, BIS plus LM79 plus LM80, Class II, complete with constant current driver, suitable for recessed mounting in false ceiling, Driver Surge Protection: = 2.5 kV, Rated Life: = 25,000 burning hours conforming to IS 10322 and BIS certified, complete in all respect. |
| 1503 | Supply and erection of LED flood light 100 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor=0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection =4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect |
| 1504 | SITC of 50 LPH (50 ltr per hour) capacity RO, Commercial type including Pre-filters complete in all respect with making necessary connections, should be suitable for raw water TDS upto 2000 ppm, the water should be filtered with PH value (range minimum 6.5 to maximum 8.0), TDS should be less than 100 ppm, recovery should be greater than 40%, and work shall be done as per entire satisfaction of Engineer-in-charge. |
| 1505 | Supply of 400 mm size wall fan, 60 watt rating, 1350 RPM speed, 205 CMM air delivery, IS 374, in-build speed regulator, blades material =plastic (polypropylene) complete with screw- nut as required for erection. |
| 1506 | Supply, installation, testing and commissioning of 4 kVA automatic voltage stabilizer, single phase, having input voltage range 170 280V AC (or wider), output 220–240V AC ±3%, Relay type, frequency 50 Hz ± 5%, efficiency =95%, copper wound transformer, with digital display, fully automatic operation, and protections including high/low voltage cut-off, overload, short circuit and thermal protection, conforming to relevant IS standards and BIS certified. complete in all respect. Make -Microtek, Livguard, Crompton. |
| 1507 | Supply of 12 watt LED round shape downlight offering high brightness (lumens efficiency ) 100 lumnes/watt) and long life span - 25000 hours, Beam angle 120° constant current drive, operate on 80V-300V A.C and made by polycarbonate material complete in all respect. Make as per approved brand list of HPHC. |
| 1508 | SITC of 150 ltr capacity water cooler having fully stainless steel corrosion resistance (grade SS304) body with puff insulation, 150/150 ltr i.e. 150 ltr per hour cooling and 150 ltr water storage capacity, Suitable for operation at ambient temp. upto 45 °C and inlet water temp. upto 30 °C, capable of delivering chilled water at 7 -12 °C , PUF insulation of min. 40 mm thickness, R134a refrigerant type, water tank sheet thickness )= 0.6 mm, Cooler Cabinet sheet thickness: 0.8mm (min), Water tank cover and lid bottom sheet material: High Impact Polystyrene (HIP) and Thickness:1.5mm (min) , Number of faucet-02, Two drainpipes shall be metallic or PVC (Poly Vinyl Chloride) , Plastic used in storage tank or in any part coming in contact with water shall be of food grade. Warranty on machine: 2 years. Warranty on compressor- 5 year, BIS Certification as per IS-1475 (Latest) complete in all respect with making necessary connections and work shall be done as per entire satisfaction of Engineer-in-charge. |
| 1509 | Supply, installation, testing and commissioning of LED flood light 50 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor )0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection )4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect |
| 1510 | S/E of min. 2200 VA (volt- amp) or above rating double battery Sine wave inverter along with built in input MCB for short -circuit and overload protection instead of just a glass fuse having CCCV or 3-stage charging, Input Voltage Range: 140V – 300V AC, Output Voltage: 220–240V AC ±10% , Frequency: 50 Hz ± 0.5 Hz , Transfer Time: (10 ms (UPS mode), LED/LCD display, automatic changeover, and complete protections including overload, short circuit, deep discharge, and overcharge protection, conforming to IS 16242/IEC 62040, BIS certified, Efficiency: =85–95% and THD (Total Harmonic Distortion): (3–5% having warranty of minimum 24 months with 2 nos 12/24V tubular type batteries of rating 200 Ah (Amp – hours ) each 48 months warranty including MS stand / trolly complete in all respect. |
| 1511 | Electrical Sub Component- Control Room (NS) |
| 1512 | SITC of 1.5 Ton Air Conditioner, High wall, 5 Star, inverter type Split A.C with cordless remoter control, 100% copper coils indoor and outdoor unit, eco-friendly Refrigeration gas R32/R410 for cooling, A.C. should be bear working on ambient temperature 52°C or above. 3 mtr copper refrigerant pipe and 3 mtr flexible drain pipe, Warranty of unit 1 year and 10 years on compressor, including cost of wall mounted / floor mounted (as required) MS Stand power coated complete in all respect. |
| 1513 | Supply and Installation of 25 mm dia PVC Hard drain pipe for A.C. , should be bear 10 kgf/cm² pressure, recess/ surface (as required), including cost of jointing of pipe complete in all respect. Make: D-plast/ Supreme/ Finolex. |
| 1514 | Supply of Integrated LED tube light = 18 watt, Rated Life: = 25,000 burning hours , 4 feet long, minimum lumen efficiency 100 lm/watti.e. 1800 lumens for 18 watt light, CRI = 80, Color Temp. (CCT) =4000 K- Natural White, Polycarbonate body, minimum IP20, Power Factor: = 0.9 , Driver Type: Constant current LED driver (inbuilt), Surge Protection: 2.5–4 kV, BIS certified, conforming to IS 10322 complete with screw- nut as required for erection. |
| 1515 | Supply of 2`×2` (600×600 mm) LED panel light fitting of min. 32 watt, integrated type, having, efficacy =100 lm/W, CRI =80, CCT 4000K/6500K as required, Polycarbonate body, minimum IP20, Power Factor: = 0.9 min, THD =10%, glare-free diffuser with UGR (19, BIS plus LM79 plus LM80, Class II, complete with constant current driver, suitable for recessed mounting in false ceiling, Driver Surge Protection: = 2.5 kV, Rated Life: = 25,000 burning hours conforming to IS 10322 and BIS certified, complete in all respect. |
| 1516 | Supply of 400 mm size wall fan, 60 watt rating, 1350 RPM speed, 205 CMM air delivery, IS 374, in-build speed regulator, blades material =plastic (polypropylene) complete with screw- nut as required for erection. |
| 1517 | Supply and Installation of Copper refrigerant pipe (with 2.5 sqmm 3/4 core copper flexible cable of approved make) for A.C. of suitable size with tubular insulation nitrile rubber of thickness min 9 mm to 13 mm , recess/ surface (as required), including cost of jointing of pipe, Silver Brazing with Nitrogen purging, complete in all respect with clamps / support etc as required and as per entire the satisfaction of Engineer - in - charge. Make- Totaline/(RAJCO). |
| 1518 | S/E of min. 2200 VA (volt- amp) or above rating double battery Sine wave inverter along with built in input MCB for short -circuit and overload protection instead of just a glass fuse having CCCV or 3-stage charging, Input Voltage Range: 140V – 300V AC, Output Voltage: 220–240V AC ±10% , Frequency: 50 Hz ± 0.5 Hz , Transfer Time: (10 ms (UPS mode), LED/LCD display, automatic changeover, and complete protections including overload, short circuit, deep discharge, and overcharge protection, conforming to IS 16242/IEC 62040, BIS certified, Efficiency: =85–95% and THD (Total Harmonic Distortion): (3–5% having warranty of minimum 24 months with 2 nos 12/24V tubular type batteries of rating 200 Ah (Amp – hours ) each 48 months warranty including MS stand / trolly complete in all respect. |
| 1519 | Electrical Sub Component- Cook House /(NS) |
| 1520 | Supply of 18/20 watt LED tube light, life minimum 25000 hours and above, 4 feet long, minimum lumen efficiency 100 lm/watt i.e. 1800/2000 lumens for 18/20 watt light respectively complete with screw- nut as required for erection. Make as per HPHC approved brand list |
| 1521 | Supply and erection of LED flood light 100 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor=0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection =4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect |
| 1522 | SITC of 50 LPH (50 ltr per hour) capacity RO, Commercial type including Pre-filters complete in all respect with making necessary connections, should be suitable for raw water TDS upto 2000 ppm, the water should be filtered with PH value (range minimum 6.5 to maximum 8.0), TDS should be less than 100 ppm, recovery should be greater than 40%, and work shall be done as per entire satisfaction of Engineer-in-charge. |
| 1523 | Supply of 15` exhaust fan (375mm)metal body, minimum 900 RPM Heavy duty with louver shutter having air delivery not less than 2000 CMH and single phase power supply, 230V, 50 Hz AC having high grade aluminum / FRP/Powder coated steel blade/ body/louver shutter, power consumption= min. 135 w , motor, IP44 or better protection including nut , bolts complete in all respect. Make-Crompton or as per approved brand list of HPHC. |
| 1524 | Supply, installation, testing and commissioning of 4 kVA automatic voltage stabilizer, single phase, having input voltage range 170–280V AC (or wider), output 220–240V AC ±3%, Relay type, frequency 50 Hz ± 5%, efficiency =95%, copper wound transformer, with digital display, fully automatic operation, and protections including high/low voltage cut-off, overload, short circuit and thermal protection, conforming to relevant IS standards and BIS certified. complete in all respect. Make -Microtek, Livguard, Crompton. |
| 1525 | Supply of 12 watt LED round shape downlight offering high brightness (lumens efficiency ) 100 lumnes/watt) and long life span - 25000 hours, Beam angle 120° constant current drive, operate on 80V-300V A.C and made by polycarbonate material complete in all respect. Make as per approved brand list of HPHC. |
| 1526 | SITC of 150 ltr capacity water cooler having fully stainless steel corrosion resistance (grade SS304) body with puff insulation, 150/150 ltr i.e. 150 ltr per hour cooling and 150 ltr water storage capacity, Suitable for operation at ambient temp. upto 45 °C and inlet water temp. upto 30 °C, capable of delivering chilled water at 7 -12 °C , PUF insulation of min. 40 mm thickness, R134a refrigerant type, water tank sheet thickness )= 0.6 mm, Cooler Cabinet sheet thickness: 0.8mm (min), Water tank cover and lid bottom sheet material: High Impact Polystyrene (HIP) and Thickness:1.5mm (min) , Number of faucet-02, Two drainpipes shall be metallic or PVC (Poly Vinyl Chloride) , Plastic used in storage tank or in any part coming in contact with water shall be of food grade. Warranty on machine: 2 years. Warranty on compressor- 5 year, BIS Certification as per IS-1475 (Latest) complete in all respect with making necessary connections and work shall be done as per entire satisfaction of Engineer-in-charge. |
| 1527 | S/E of min. 2200 VA (volt- amp) or above rating double battery Sine wave inverter along with built in input MCB for short -circuit and overload protection instead of just a glass fuse having CCCV or 3-stage charging, Input Voltage Range: 140V – 300V AC, Output Voltage: 220–240V AC ±10% , Frequency: 50 Hz ± 0.5 Hz , Transfer Time: (10 ms (UPS mode), LED/LCD display, automatic changeover, and complete protections including overload, short circuit, deep discharge, and overcharge protection, conforming to IS 16242/IEC 62040, BIS certified, Efficiency: =85–95% and THD (Total Harmonic Distortion): (3–5% having warranty of minimum 24 months with 2 nos 12/24V tubular type batteries of rating 200 Ah (Amp – hours ) each 48 months warranty including MS stand / trolly complete in all respect. |
| 1528 | Electrical Sub Component- Special Security Enclosures (3nos.) (NS) |
| 1529 | Supply and erection of LED flood light 100 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor=0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection =4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect |
| 1530 | SITC of 50 LPH (50 ltr per hour) capacity RO, Commercial type including Pre-filters complete in all respect with making necessary connections, should be suitable for raw water TDS upto 2000 ppm, the water should be filtered with PH value (range minimum 6.5 to maximum 8.0), TDS should be less than 100 ppm, recovery should be greater than 40%, and work shall be done as per entire satisfaction of Engineer-in-charge. |
| 1531 | Supply, installation, testing and commissioning of 4 kVA automatic voltage stabilizer, single phase, having input voltage range 170–280V AC (or wider), output 220–240V AC ±3%, Relay type, frequency 50 Hz ± 5%, efficiency =95%, copper wound transformer, with digital display, fully automatic operation, and protections including high/low voltage cut-off, overload, short circuit and thermal protection, conforming to relevant IS standards and BIS certified. complete in all respect. Make -Microtek, Livguard, Crompton. |
| 1532 | SITC of 150 ltr capacity water cooler having fully stainless steel corrosion resistance (grade SS304) body with puff insulation, 150/150 ltr i.e. 150 ltr per hour cooling and 150 ltr water storage capacity, Suitable for operation at ambient temp. upto 45 °C and inlet water temp. upto 30 °C, capable of delivering chilled water at 7 -12 °C , PUF insulation of min. 40 mm thickness, R134a refrigerant type, water tank sheet thickness )= 0.6 mm, Cooler Cabinet sheet thickness: 0.8mm (min), Water tank cover and lid bottom sheet material: High Impact Polystyrene (HIP) and Thickness:1.5mm (min) , Number of faucet-02, Two drainpipes shall be metallic or PVC (Poly Vinyl Chloride) , Plastic used in storage tank or in any part coming in contact with water shall be of food grade. Warranty on machine: 2 years. Warranty on compressor- 5 year, BIS Certification as per IS-1475 (Latest) complete in all respect with making necessary connections and work shall be done as per entire satisfaction of Engineer-in-charge. |
| 1533 | S/E of min. 2200 VA (volt- amp) or above rating double battery Sine wave inverter along with built in input MCB for short -circuit and overload protection instead of just a glass fuse having CCCV or 3-stage charging, Input Voltage Range: 140V – 300V AC, Output Voltage: 220–240V AC ±10% , Frequency: 50 Hz ± 0.5 Hz , Transfer Time: (10 ms (UPS mode), LED/LCD display, automatic changeover, and complete protections including overload, short circuit, deep discharge, and overcharge protection, conforming to IS 16242/IEC 62040, BIS certified, Efficiency: =85–95% and THD (Total Harmonic Distortion): (3–5% having warranty of minimum 24 months with 2 nos 12/24V tubular type batteries of rating 200 Ah (Amp – hours ) each 48 months warranty including MS stand / trolly complete in all respect. |
| 1534 | Electrical Sub Component- Factory Shed / Correctional Compound (NS) |
| 1535 | Supply of Integrated LED tube light = 18 watt, Rated Life: = 25,000 burning hours , 4 feet long, minimum lumen efficiency 100 lm/watti.e. 1800 lumens for 18 watt light, CRI = 80, Color Temp. (CCT) =4000 K- Natural White, Polycarbonate body, minimum IP20, Power Factor: = 0.9 , Driver Type: Constant current LED driver (inbuilt), Surge Protection: 2.5–4 kV, BIS certified, conforming to IS 10322 complete with screw- nut as required for erection. |
| 1536 | Supply of 2`×2` (600×600 mm) LED panel light fitting of min. 32 watt, integrated type, having, efficacy =100 lm/W, CRI =80, CCT 4000K/6500K as required, Polycarbonate body, minimum IP20, Power Factor: = 0.9 min, THD =10%, glare-free diffuser with UGR (19, BIS plus LM79 plus LM80, Class II, complete with constant current driver, suitable for recessed mounting in false ceiling, Driver Surge Protection: = 2.5 kV, Rated Life: = 25,000 burning hours conforming to IS 10322 and BIS certified, complete in all respect. |
| 1537 | Supply and erection of LED flood light 100 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor=0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection =4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect |
| 1538 | SITC of 50 LPH (50 ltr per hour) capacity RO, Commercial type including Pre-filters complete in all respect with making necessary connections, should be suitable for raw water TDS upto 2000 ppm, the water should be filtered with PH value (range minimum 6.5 to maximum 8.0), TDS should be less than 100 ppm, recovery should be greater than 40%, and work shall be done as per entire satisfaction of Engineer-in-charge. |
| 1539 | Supply, installation, testing and commissioning of 4 kVA automatic voltage stabilizer, single phase, having input voltage range 170 280V AC (or wider), output 220–240V AC ±3%, Relay type, frequency 50 Hz ± 5%, efficiency =95%, copper wound transformer, with digital display, fully automatic operation, and protections including high/low voltage cut-off, overload, short circuit and thermal protection, conforming to relevant IS standards and BIS certified. complete in all respect. Make -Microtek, Livguard, Crompton. |
| 1540 | SITC of 150 ltr capacity water cooler having fully stainless steel corrosion resistance (grade SS304) body with puff insulation, 150/150 ltr i.e. 150 ltr per hour cooling and 150 ltr water storage capacity, Suitable for operation at ambient temp. upto 45 °C and inlet water temp. upto 30 °C, capable of delivering chilled water at 7 -12 °C , PUF insulation of min. 40 mm thickness, R134a refrigerant type, water tank sheet thickness )= 0.6 mm, Cooler Cabinet sheet thickness: 0.8mm (min), Water tank cover and lid bottom sheet material: High Impact Polystyrene (HIP) and Thickness:1.5mm (min) , Number of faucet-02, Two drainpipes shall be metallic or PVC (Poly Vinyl Chloride) , Plastic used in storage tank or in any part coming in contact with water shall be of food grade. Warranty on machine: 2 years. Warranty on compressor- 5 year, BIS Certification as per IS-1475 (Latest) complete in all respect with making necessary connections and work shall be done as per entire satisfaction of Engineer-in-charge. |
| 1541 | Supply, installation, testing and commissioning of LED flood light 50 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor )0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection )4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect |
| 1542 | S/E of min. 2200 VA (volt- amp) or above rating double battery Sine wave inverter along with built in input MCB for short -circuit and overload protection instead of just a glass fuse having CCCV or 3-stage charging, Input Voltage Range: 140V – 300V AC, Output Voltage: 220–240V AC ±10% , Frequency: 50 Hz ± 0.5 Hz , Transfer Time: (10 ms (UPS mode), LED/LCD display, automatic changeover, and complete protections including overload, short circuit, deep discharge, and overcharge protection, conforming to IS 16242/IEC 62040, BIS certified, Efficiency: =85–95% and THD (Total Harmonic Distortion): (3–5% having warranty of minimum 24 months with 2 nos 12/24V tubular type batteries of rating 200 Ah (Amp – hours ) each 48 months warranty including MS stand / trolly complete in all respect. |
| 1543 | Electrical sub component-watch tower (NS) |
| 1544 | Supply of Integrated LED tube light = 18 watt, Rated Life: = 25,000 burning hours , 4 feet long, minimum lumen efficiency 100 lm/watti.e. 1800 lumens for 18 watt light, CRI = 80, Color Temp. (CCT) =4000 K- Natural White, Polycarbonate body, minimum IP20, Power Factor: = 0.9 , Driver Type: Constant current LED driver (inbuilt), Surge Protection: 2.5–4 kV, BIS certified, conforming to IS 10322 complete with screw- nut as required for erection. |
| 1545 | Supply and erection of LED flood light 100 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor=0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection =4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect |
| 1546 | Supply and erection of LED flood light 200 watt featuring min. IP 65 or better, water proofing coated and lumens efficiency = 100 lumens/watt, CRI =80, CCT 6500K and long life span =25000 hours, operate on 100-300 V , 50 Hz, A.C with 120 degree Beam angle, power factor=0.90, complete with inbuilt driver, die-cast aluminum housing with toughened glass cover, IP65 or better protection, surge protection =4 kV, suitable for outdoor applications, conforming to IS 10322 and BIS certified, complete in all respect. |
| 1547 | Supply of 400 mm size wall fan, 60 watt rating, 1350 RPM speed, 205 CMM air delivery, IS 374, in-build speed regulator, blades material =plastic (polypropylene) complete with screw- nut as required for erection. |
| 1548 | Electrical Sub Component- Fire Fighting System (NS) |
| 1549 | Providing and fixing of pressure switch in M.S. pipe line including connection etc. as required. (DSR 18.22) |
| 1550 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required (DSR 16.8) |
| 1551 | Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm internal diameter (DSR 18.7.7) |
| 1552 | Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm internal diameter (DSR 18.7.6) |
| 1553 | Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 50 mm internal diameter (DSR 18.7.4) |
| 1554 | Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm internal diameter (DSR 18.7.1) |
| 1555 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve and nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket. (DSR 18.17) |
| 1556 | Supplying and fixing single headed internal and External hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel (DSR 18.9.2) |
| 1557 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with Gl wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304) (DSR 18.16.2) |
| 1558 | Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: Stainless Steel (Grade 304) (DSR 18.18.2) |
| 1559 | Providing and fixing Weather proof hose cabinets fabricated from 16g M.S sheet with full glass door and locking arrangement, suitable to accommodate 2 nos. 15m long hose and 1 no branch pipe. The cabinet shall be painted with ane coat of primer and finished stove enamelled `Fire Red` , `Fire Hose ` written on front including suitably mountedon a raised masonry platfrom as required. (Approx 0.9mx0.6mx0.3m). |
| 1560 | Supplying and laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring and FRLS outer sheath complete as required.(DSR 17.5.2)) |
| 1561 | Providing, Installation, Testing and Commissioning of CO2 Type Fire Extinguisher complete with wheel valve arrangement, high-pressure wire braided hose pipe etc. As per IS : 2878 Capacity 4.5 Kg.... |
| 1562 | Supplying, installation , testing and commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/ zone covered complete with all connections, interconnections as required. DSR 17.1.9.1.- 4 zone control panel for fire alarm system |
| 1563 | Supplying, installation, testing and commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate and suitable for operation with amplifier i/c line matching transformer etc. complete as required. (DSR 17.1.6) |
| 1564 | Supplying, installation, testing and commissioning of manual call point of MS construction in surface /recess with stainless steel chain and Hammer assembly complete as required. DSR 17.1.3 |
| 1565 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 2 way - 100 mm dia M.S. Pipe (DSR 18.19.1) |
| 1566 | Providing, installation, testing and commissioning of Sluice Valve fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100mm dia (DSR 18.12.5 ) |
| 1567 | (A) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 (C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-`F` insulation, conforming to IS-325. (D) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 LPM 35M Head (DSR 18.4.1) |
| 1568 | (A) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 (C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-`F` insulation, conforming to IS-325. (D) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 LPM 35M Head (DSR 18.4.2) |
| 1569 | Providing, testing and commissioning OF DOL type fire pump panel suitable for 450 lpm fire pump 415 V plus /-6 volts, panel 7.5 HP Dual Starter, Power Connector 18A, Load relay 9-15A, Auto Manual Selector Switch, Push Button 2 Nos, Indication Lamp 6 Volts AC - 6 Nos, Power wiring 4mm, Control wiring Terminal, Panel Board 400x400x200mm. (Terrace Pump Panel) |
| 1570 | Providing, testing and commissioning OF DOL type fire pump panel suitable for 900 lpm fire pump 415 V plus /-6 volts, panel 10 HP Dual Starter, Power Connector 18A, Load relay 9-15A, Auto Manual Selector Switch, Push Button 2 Nos, Indication Lamp 6 Volts AC - 6 Nos, Power wiring 4mm, Control wiring Terminal, Panel Board 400x400x200mm. (Terrace Pump Panel) |
| 1571 | Providing , fixing, testing and commissioning of 15 mm dia. quartzoid bulb type Sprinkler of rating 68° C with required accessories: DSR 18.21.1) Pendent Sprinkler. |
| 1572 | Providing, Installation, Testing and Commissioning of Mono Ammonium Phosphate (ABC) type cartridge operated extinguishers. Capacity: 4 Kg ABC Power type fire extinguisher : conform to IS 15683 (ABC type extinguishers), extinguisher shall have minimum fire rating 2A/21B or higher, discharge time = 13 seconds and discharge range = 2 meters, ISI mark. |
| 1573 | Providing, Fixing of Self Glowing Exit Sign Board of size 12”x 6” double side printed made of Luminescent safety rigid sheet in standard colour, photo Luminescent sheet ( should be resistant moisture, UV degradation ) made of crystals consisting mainly Zinc Sulphide in protective glass like shell, green and yellow crystal Luminescent ( glass in dark) by action of light, afterglow duration (visible for 8-10 hours), Thickness ( 2-3 mm rigid sheet). |
| 1574 | Supply and erection of Fire Buckets , min 9 ltr capacity, Mild steel thickness min. 0.9 mm, Two Coats of White Paint Inside, Two Coats of Red Paint Outside, Ears and Handle Painted Black, `FIRE` painted centrally outside in Black, 75 mm high and approx. 12 mm thick, sand filling (clean dry sand) |
| 1575 | 23. Supply and Laying of 3 core x 2.5 sq mm FRLS PVC insulated copper conductor cable ( IS 694 ) in exisiting PVC conduit as required. |
| 1576 | Supply and installing ISI marked under (IS: 13386) 6 ltr. Capacity wet chemical fire extinguisher Stored Pressured with pressure gauge, fire rating min. Class-F, discharge performance(Time, Range) complete with discharge hose for Kitchen use.... Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail