| 1 | Dismantling R.C. floor, roof, beams etc.including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. |
| 2 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 3 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in First floor as per relevant IS codes. |
| 4 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of First floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 5 | Brick work with 1st class bricks in cement mortar (1:4) |
| 6 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and real of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of First floor/upto 4 mTor steel/Mild Steel |
| 7 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (First floor). (Excluding cost of chipping over concrete surface)With 1:4 cement mortar (c) 10 mm thick plaster Ceiling Plaster |
| 8 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (First floor).[Excluding cost of chipping over concrete surface(i) With 1:4 cement mortar (c) 15 mm thick plaster Celling Plaster |
| 9 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer):(Two coats) ) ii. Luxury Quality |
| 10 | M.S. or W.I. Ornamental grill of approved design joints continuously welded with MS, WI Flats and bars of ) Grill weighing above 10 Kg./sq.mtr |
| 11 | Supplying fitting & fixing in position suspended false celling with frame work of aluminium hollow section of size 50mm X 25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm X 25mm having size of 600mm x 600mm ceiling with aluminium composit panels (ACP)- Interior grade of thickness 3.0mm, comprising of proctective film, polyester coating, primer, aluminium coll, adhesive film, polyethylene core again with one layer adhesive flm, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealentcomplete. |
| 12 | Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Thermoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Two Coat outside |
| 13 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the farme exluding cost of concrete, Iron Butt Hinges and M.5 clamps. (The quantum should be correted upto three decimals) (a) 1st class Best Indian teak. |
| 14 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in positon but excluding the cost of hinge and other fittings. In First floor (iv) 25mm thick shutters with 12mm thick panel of size 30 to 45 Cm.(a) Ordinary Teak Wood |
| 15 | Supplying fitting and fixing 15 to 18 mm thick Marble slab/Tile in riser of step or skirting (upto 300 mm ht) over 15mm (avg) thick base of Cement mortar (1:2) laid with white cement surry 4.4 kg/Sqm at back side of marble and jointed with white cement slurry 2.2 kg Sqm with necessary pigments including grinding and Granite Polishing [White cement and Pigment to be supplied by the Agency]a with Makrana plain pink / Adrangs Pink/Garbh Gulabi/ Maypur Pink/Udaypur green/Back Bhalsana(i) Area of each Slab/tile upto 0.3 sqm. |
| 16 | Electrification Work |
| 17 | Sub Total |
| 18 | GST 18% |
| 19 | CESS 1% Please Enable Macros to View BoQ information |