| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 2 | Removing dry or oil bound distemper, water proofing cement paintand the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 3 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion. |
| 4 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 5 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 6 | With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 7 | 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 8 | 1:6 (1 cement: 6 coarse sand) |
| 9 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 10 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 11 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: |
| 12 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50gram/litre |
| 13 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer, including applying additional coats wherever required to achieve even shade and colour. |
| 14 | Old work (one or more coats) |
| 15 | Laboratory Table with Granite Top: Size: 5’ (L) x 3’ (W) x 3’ (H).Providing and placing laboratory table with Granite Top as per following specification. C-Frame Structure: CRCA MS rectangular tube of cross section of 60×30×2 mm (IS: 7138 & IS: 513) Powder-coated (pure epoxy, 40–50 microns),Open front design for knee space, adjustable feet (tolerance from -5 to +20 mm) , includes horizontal members(Horizontal Members: 60 × 30 × 2 mm CRCA MS tube connecting C-frames) powder-coated, removable back panels & Cover panel(made of CRCA, 1mm thickness, with pure epoxy powder coated), skirting, and drainage support. Worktop: Jet Black Granite, 18 mm (±2 mm) thick,Chamfered & polished with V-groove edge, Backed with 6 mm neoprene mat, sealed with black silicone, Overhang: 25 mm (front), 30 mm (sides). Reagent Shelf: Fixed-type, single-sided (3x1500 mm), 2-tier CRCA MS Powder-coated, with provisions for electrical sockets. Storage Cabinet (Suspended Type): W600mm, D530mm, H635mm, Configuration: 2 Shutters + 1 Drawer,CRCA MS construction (1.2 mm & 0.8 mm thick panels),Epoxy coated, removable back panel, recessed aluminum handle (160 mm CTC), SS304 hinges, 500 mm ball slide for drawer, sound-dampened shutters,180° 10-lever cam lock, roller catch, and knee space panel (22-gauge MS). All complete as per direction of Engineer-in-charge. |
| 16 | Roller Blind:Providing & fixing Roller blinds (double) with approved fabric ( Sunscreen) combination of PVC and Polyester and approved color with mount and roll mechanism (back or front) with chain drive dropped not less than 500mm with side control (left or right) and spring assist for smooth operation including necessary anodized/powdered coated aluminium member for top of required size and bottom roller (not less than 38mm dia.) member. All complete as per diirection of Engineer-In-Charge. |
| 17 | Supplying and Placing of Height adjustable Revolving Stool for Laboratory.Specifications: size of round seat not less than 14\\".Base: Constructed with a reinforced nylon base featuring five feet for enhanced stability and durability.Mobility: Equipped with five twin-wheel swivel casters, diameter Ø 50 mm, allowing smooth and 360° multidirectional movement.Height Adjustment: Fitted with a gas lift mechanism for seat height adjustment ranging from 520 mm to 710 mm, ensuring ergonomic seating comfort for various users.Seat and Backrest: Seat Type: High backrest design.Upholstery: Covered with high-quality leatherite finish for easy cleaning and professional appearance.Padding: Padded with 50 mm thick high-density foam for long-lasting comfort and support. All complete as per direction of Engineer-in-charge. |
| 18 | Supplying, fitting and fixing of false ceiling framework with powder coated exposed G.I. grid suspension system (E-Grid T 2430/1510 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6mm dia G.I. wire from purlins / soffit. all complete as per drawing & directions of Engineer-in-charge. |
| 19 | Supplying ,fitting & fixing Eco-friendly, Water Resistance and Incombustable Calcium Silicate board/tiles (Density >900 Kg per Cu.M.) of approved design and brand placed in the grid module to form a false ceiling all complete as per drawing & direction of Engineer - in- Charge. False ceiling with 6mm thick square edged Calcium Silicate tiles (size 595mm X 595mm) |
| 20 | Godrej Hydraulic door closer fitted and fixed complete. Heavy type |
| 21 | Supply of 1.1 KV grade following PVC insulated Armoured cable confirming the IS 7098 (Part 1) 1988 specification, complete in all respect as per the direction of the Engineer-In charge. :- |
| 22 | 4Cx16 sq.mm Copper cable. |
| 23 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 24 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 25 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 26 | 4 X 16 sq. mm (28mm) |
| 27 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) |
| 28 | 4 way (4 + 12), Double door |
| 29 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete connections, testing and commissioning etc. as required. Single pole |
| 30 | SP MCB |
| 31 | Double pole |
| 32 | Triple pole |
| 33 | Triple pole and neutral |
| 34 | Supplying and fixing 63 A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete connections, testing and commissioning etc. as required,complete in all respect as per the direction of the Engineer-In charge. |
| 35 | 63 Amp Four Pole. |
| 36 | Providing and fixing Sheet steel duly powder coated metal enclosure for FP MCB complete in all respect as per the direction of the Engineer-In charge. |
| 37 | Suuply, installation & testing of 20 amps. TPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure complete in all respect as per the direction of the Engineer-In charge. |
| 38 | Sheet steel DP MCB enclosure complete in all respect as per the direction of the Engineer-In charge. |
| 39 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing recessed steel/ PVC conduit as required. |
| 40 | 3 x 1.5 sq. mm |
| 41 | 3 x 2.5 sq. mm |
| 42 | 3 x 4 sq. mm |
| 43 | 6 x 4 sq. mm |
| 44 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 45 | Finishing of end termination with proper size of pin / ring type copper solderless socket by crimping method of following sizes PVC insulated copper conductor complete in all respect as per the direction of the Engineer-In charge. |
| 46 | 1 x 2.5 sq. mm |
| 47 | 1 x 4 sq. mm |
| 48 | Supplying and fixing modular Plastic box of following sizes (nominal size) on surface for modular switch socket fixtures complete in all respect as per the direction of the Engineer-In charge. |
| 49 | 6 Modular |
| 50 | Supplying and fixing modular Cover Plate of following sizes (nominal size) on surface for modular switch socket fixtures complete in all respect as per the direction of the Engineer-In charge. |
| 51 | 6 Modular |
| 52 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 53 | 5/6 A switch |
| 54 | 15/16 A switch |
| 55 | 3 pin 5/6 A socket outlet |
| 56 | 6 pin 15/16 A socket outlet |
| 57 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) |
| 58 | 36 watt |
| 59 | Supply, Installation, Testing and Commissioning of ceiling fan with BrushLess Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, steel/Al body Power Factor not less than 0.9,Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS :374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fanSupply, earthing etc. complete as required. |
| 60 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 61 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Please Enable Macros to View BoQ information |