| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 5 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete |
| 8 | Providing and fixing 16 gauge thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece |
| 9 | Steel work in built up tubular (round,square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding,welding with gusset plates and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes |
| 10 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) : Natural colour insulating board: 12 mm thick |
| 11 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of orrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 12 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 13 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. |
| 14 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc.complete : Kiln seasoned and chemically treated hollock wood( 50x20 mm ) |
| 15 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With ready mixed pink or grey primer on wood work hard and soft wood) having VOC content less than 50 grams/ litre |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 17 | Providing and fixing in wall lining medium density fibre board IS: 14587:1998 marked, Pre-laminated one side decorative lamination and other side balancing lamination, with necessary fixing arrangement and screws etc. 18 mm thick.complete. |
| 18 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost o .......... to IS: 1868, Minimum anodic coating of gradeAC 15) |
| 19 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 20 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer in-charge. Nominal concrete 1:3:6 or richer mix |
| 21 | Providing Stone soling of thickness 100mm in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. |
| 22 | Fabrication, providing and welding 1.5mm (16 gauge) thick plain GI sheet on room wall and gable fascia of watch tower on MS framework, including cost of plain sheet, cutting of plain sheet to the required size, cost of welding rods, providing and painting one coat of red oxide primer, cost of thinners, paint brushes, sand paper etc. complete as directed together with cost of scaffolding, all materials, labour, tools, plants etc. to the satisfaction of Engineer-in-Charge. (cost of providing and welding of MS framework shall be paid under relevant item). |
| 23 | Fabrication, welding and providing of 3mm thick MS chequered sheet on room flooring and ladder landing of watch tower on MS work, including cost of 3mm thick MS chequered sheet, cutting of sheet to the required size, cost of welding rods, providing and painting one coat of red oxide primer, cost of thinners, paint brushes, sand paper etc. complete as directed together with cost of scaffolding, all materials, labour, tools, plants etc. to the satisfaction of Engineer-in-Charge. (cost of providing and welding of MS framework shall be paid under relevant item). |
| 24 | Fabrication, welding and providing 8mm thick MS anchor plate to connect the base of the MS vertical post with the RCC column including providing and welding bracing on all four sides, cutting of 1ft x 1ft sheet to the required size, cost of welding rods, grinding, providing and painting one coat of red oxide primer, cost of thinners, paint brushes, sand paper, 16mm diameter nut & bolt for anchoring etc. complete as directed together with cost of scaffolding, all materials, labour, tools, plants etc. to the satisfaction of Engineer-in-Charge. The scope of work also incude erection of the vertical MS post with anchorage on the column to proper line, level and plumb, grouting of nut & bolt on RCC pillar etc. complete |
| 25 | Providing and fixing of 1.5mm thick PVC Carpet of room size 2.20 m length (1.40m width) including cost of PVC Carpet, Cutting & fixing of carpet with dendrite adhesive etc. complete as directed ,labour, carriage, wastage etc. to the satisfaction of Engineer-in-Charge. |
| 26 | Wiring for circuit/ submain wiring along with earth wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface medium class PVC conduit as required.. |
| 27 | Supplying and fixing of 6 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 28 | Supplying and fixing 5 A to 32 A (20 Amp) rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Double pole in the MCB DB complete with connections, testing and commissioning etc. as required |
| 29 | 18-22 Watt LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours 47 DELHI SCHEDULE OF RATES (E&M)-2025 with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 30 | Supplying and fixing of 25mm sizes of medium class PVC conduit along with accessories in surface including cutting the wall and making good the same in case of recessed conduit as required. |
| 31 | Supplying and fixing 8 Module (125mmX125mm) size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 32 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch |
| 33 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 socket outlet |
| 34 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 socket outlet |
| 35 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 switch |
| 36 | Note-1: General Notes 1.For their own interest, contractors are advised to inspect the site with prior permission before quoting their rates. 2. All the dismantled /demolished materials shall be dumped at one place as decided by the department within 150mtr lead. 3. All the samples of materials which are to be used shall be approved by the department in advance. 4. The contractor shall comply with the provision of the Payment of Wages act 5. Rates quoted shall be inclusive of all cost of materials, labour, carriage, taxes, GST, labourcess, water charges, elctricity charges, signorage charges, wastages etc.. 6. Rates quoted shall be excluding the amount of EPFO and ESIC contributions. EPFO and ESIC contributions are reimbursable on production of valid proof of payment made by the contractor as per CPWD norms. Please Enable Macros to View BoQ information |