| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 2 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 3 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. |
| 4 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure aboveplinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : With F.P.S.(non modular) bricks |
| 5 | 20 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing andreinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 8 | Additional for pump service require. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 10 | Suspended floors, roofs, landings, balconies and access platform |
| 11 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 12 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. |
| 13 | Providing and fixing Upvc Window (wood look colur) 3 Track sliding channels with 6 mm thick toughned glass and s.s. mesh all complete as per direction of Engineer-in-charge. |
| 14 | Providing and fixing wooden door Frame with Glass on top complete as per required. Size 8'x 3.5' |
| 15 | Providing and fixing wooden door Shutter including all hardware complete as per required. Size 7'x 3'. |
| 16 | Supply and installation of Door Closer. |
| 17 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 18 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. |
| 19 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 20 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work 2 coat |
| 21 | Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 22 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. 110 mm diameter |
| 23 | Bend 87.5° 110 mm bend |
| 24 | Providing & applying waterproof coating with fiber mesh including all five layer of coating complete as per approved. |
| 25 | Providing and laying vitrified floor tiles (Tempshield Biano) on roof in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointin with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 26 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. size 600x 600 mm |
| 27 | Providing and laying vitrified floor tiles Skirting 100 mm. |
| 28 | Demolishing mud phaska in terracing and disposal of material within 50 metres lead. |
| 29 | Supply & installation of pvc conduit pipe 25 mm dia including cost of chasing of wall and repair same. |
| 30 | Supply & installation of main wiring from panel to DB 10 sqmm x3 wire. |
| 31 | Supply & installation of Circuit wiring for Power Supply with 2.5 sqmm x3 wire. |
| 32 | Supply & installation of 3 module m.s. box, pvc plate, 1 nos 16 amp switch/socket complete set. |
| 33 | Supply & installation of Circuit wiring for light 1.5 sqmm x3 (upto 15 mtr) wire including switch, socket, box, plate, etc. |
| 34 | Supply & installation of Distribution Board 4 way TPNdouble door complete as per require. |
| 35 | Supply & installation of MCB 4P 63 Amp. |
| 36 | Supply & installation of MCB 32 amp SP. |
| 37 | LED Modern 4 Feet LED Profile Linear Light 36 Watt for Office, Corporate, Residences, Aluminium Pendant Fixture with Adjustable Hanging Wire (Natural White-36 Watts) |
| 38 | Supply & installation of Circuit wiring for AC with 4 sqmm x3 wire. |
| 39 | Supply & installation of MCB with 3 module box, face plate, 16 amp socket, etc. |
| 40 | Supply & installation of copper piping with insulation, drain pipe for AC including chasing of wall and repair same etc. |
| 41 | Supply & installation of 1.5 TR split AC 3 star inverter type. |
| 42 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (150 cft per trip). Please Enable Macros to View BoQ information |