Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earthwork in stoney earth and gravels mixed with stone and boulder not exceeding 0.014 cum in volume within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3min depth and as per specification approved by the department |
| 2 | Filling foundation trenches with excavated earth including watering ramming and compacting in layer not exceeding 150 mm thick including labour sundries T & P etc complete and as per direction of Engineer-in- charge |
| 3 | Filling foundation and plinth with sand well watered and rammed including cost conveyance royalty of sand and labour etc complete. |
| 4 | P.C.C. (1:3:6) as per drawing & technical specification including cost of all materials labour T&P etc complete. |
| 5 | Plain Cement Concrete M-20 Grade using 40mm size hard granite H.B. metal approved quality from approved quarry including hoisting laying using concrete mixture and vibrators including cost, carriage, royalty, cost of all labour T.&P. etc complete and as directed by E.I.C. |
| 6 | Providing, lifting, hoisting and laying Reinforoad Comer Concrsis of M-25 grade in Column base, Column Footings, Raft Foundation,Stem of the Columns, beams, chaujja, fin, lintel, stair Case, jali , shelves and slab etc as per approved designs and drawings having a minimum Compressive strength ( in work test) 20N. / Square mm. in 15cm. cubes at 28 days after mixing and test conducted in accordance with 1.S. 456 and 1.S. 516 using screened & washed sharp Hiver sand far mertar and 18mm. to 20 mm. size black hand crusher broken granite stone chips of Spproved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement Including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days including, centering and shuttering then after {dismantfing and removing the debrises away from the work site and finishing the exposed ~ fSurface -smooth. providing grooves-or beads: wherever necessary. including: cost, conveyance, loading, unloading, royalties and taxes of all materials , cost of all labours, scaffolding, sundries,T&P required for the work etc. Complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Stee! and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in. proper position as directed by the Engineer-in-charge. |
| 7 | Plinth Bend |
| 8 | Column Ground Floor |
| 9 | 1st Floor |
| 10 | 2nd Floor |
| 11 | 3rd Floor |
| 12 | 4th Floor |
| 13 | Ground Floor Lintel |
| 14 | Roof Beam Ground Floor |
| 15 | 1st Floor |
| 16 | 2nd Floor |
| 17 | 3rd Floor |
| 18 | Roof Slab Ground Floor |
| 19 | 1st Floor |
| 20 | 2nd Floor |
| 21 | Stair Case Ground Floor |
| 22 | 1st Floor |
| 23 | Chajja Ground Floor |
| 24 | Fin Drupss (0.075m) thick |
| 25 | Cutting, Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or| jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost,canveyance,loading,..unloading & taxes of M.S PlaiwHYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, TP and Scaffolding complete in alt respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.SPiainHYSD/TMT reinforcement bars consumed in the work only. |
| 26 | First Floor |
| 27 | Second Floor |
| 28 | Fly-Ash Brick masonary with c.m (1:6) in foundation and Plinth using Fly-Ash Bricks 250 x 120 x 80mm size watering ,curing etc complete including cost of materials, labour all comp.complete as per the direction of Engineer-In-Charge |
| 29 | Brick work with Fly Ash bricks 25cm x 12cm x 8cm size having crusing Strength not less then 75kg/cm2 in cement mortar (1:6) in superstructure including all cost complete as per direction of Enginner-In-Charge. |
| 30 | First Floor |
| 31 | Fly-Ash Brick Masonary with C.M (1:4) in Superstructure using Flyash Brick of size 250x120x80mm, watering curing etc complete for the work. |
| 32 | Providing 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to out, Side smooth surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface Smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required omamental finish as per drawing, watering, curing, Scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all Jabour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 33 | Ground Floor |
| 34 | 16mm thick cement plaster (1:6) on brick work inside wall including all cost conveyance royalty & taxes etc, to work site as per direction of Engineer-In-Charge |
| 35 | First Floor |
| 36 | 6mm thick cement plaster (1:4) over R.C.C surface including all cost and conveyance, royalty, taxes of all materials etc.complete as directed by the Engineer in Charge. |
| 37 | First Floor |
| 38 | Second Floor |
| 39 | Providing and Painting wall Surface one coat with Wall Primer to give an even shed before applying weather coat to Exterior walls including cost of Primer , labour, T&P all comp. |
| 40 | Wall painting 2 coats with weather coat over a coat of primer to inside and out side smooth surface with all cost of labour, T&P material etc complete. |
| 41 | First Floor |
| 42 | Second Floor |
| 43 | Wall painting 2 coats with plastic emulsion paint of approved shade on new work to give an even shade including cost of paint etc complete. |
| 44 | Finishing wall surface of walls with Acrylic wall putty (Water based ) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete. |
| 45 | Providing,Fitting & Fixing of Granite Stone in Floors, steps &Landing slab over 25mm thick cement plaster in Cement Mortar (1:1) including cost of Tiles, Labour, T&P all comp. |
| 46 | First Floor |
| 47 | Providing, Fitting & Fixing of Granite Stone in Walls on 12mm thick Cement Plaster in Cement mortar (1:3) jointed with neat cement Slurry mixed with Pigments including cost of Tiles, labour, T&P all comp. |
| 48 | Supplying, fitting and fixing vitrified tile (Plain) in floors of size 600mm x 600mm of approved make conformaing to IS : 13755 laid on 20 mm thick cement mortar (1:4) (1 cement :4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the worl all complete as per direction of E.I.C. (For New work only) |
| 49 | First Floor |
| 50 | Second Floor |
| 51 | Providing, Fitting & Fixing of Virtified tiles in Walls on 12mm thick Cement Plaster in Cement mortar (1:3) jointed with neat cement Slurry mixed with Pigments including cost of Tiles, labour, T&P all comp. |
| 52 | Providing,Fitting & Fixing of Kota Stone in Floors, steps &Landing slab over 20mm thick cement plaster in Cement Mortar (1:4) including cost of Tiles, Labour, T&P all comp. |
| 53 | Providing, fitting and fixing the M.S. grills and placing 12mm Sq bars in position including cost, covenyance and royalty of all materials and cost of all labour etc. |
| 54 | Painting two coats to new Steel work with any approved shade over a coat of primer.including cost of all materials and labour T&p etc. |
| 55 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 56 | Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 57 | Supplying, Fitting and Fixing of Stainless Steel hand railing using 50mm dia of 2mm thick circular pipe as Balustrade as per approved design and specifications all comp. |
| 58 | Providing and fixing of 8mm thk toughend glass on Allumunium frame work (Mulliun & transom) including cover plate and pressure plate with all other accessorries, According drawing and design. |
| 59 | Providing and fitting of glass pane (5 mm thick Black Glass) for slinding windows and ventilators including cost of all materials, labour T&P etc. complete. (Measurement to be taken as per actual) |
| 60 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips complete all as per direction of Engineer-in-Charge. |
| 61 | PAVER BLOCKConstruction of granular sub-base by providing Grading - VI Material as per table 400-2, mixing in a mechanical mix plant at OMC, carraige of mixed Material to work site, spreding in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401SDB. |
| 62 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018. |
| 63 | Supplying and fixing of Pre cast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. |
| 64 | ELECTRICAL WORK Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make of Modular GI box - Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) |
| 65 | Group B |
| 66 | Group C |
| 67 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 68 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION) |
| 69 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 70 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 71 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 72 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 73 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 74 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 75 | Supplying and fixing of following sizes of medium class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/ BEC/ Precision/ Norpak |
| 76 | 25 MM |
| 77 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 78 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 230 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 79 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year. |
| 80 | Fittings & Fixtures Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 81 | SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) |
| 82 | SITC of 120W Outdoor Flood LED lights with polycarbonate module lens provided with silicon gasket for efficient ingree protection with silicon potted driver, IP66, IK08 , bottom opening maintanance , LPW not less than 120.Input Voltage: 85-265V AC ,Body : pressure Die cast Aluminium housing designed to act as heat sink for proper heat dissipation, IP66, CRI greater than eual to 70, burning hours 50,000 hrs, pf greater than 0.95, THD less than 10% as per the Drawing for inspection as required Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj as rerquired & as per direction of Engg.-in-Charge.The luminaire should be Replacement Warranty will be 2 years . |
| 83 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 84 | Supply, Installation, Testing & Commissioning of of IP65 (10-12)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole & PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10%. CRI>70, PF>.95. CCT - 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100-275)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved.Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge. Make-K-LITE/Philips/LT/PANASONIC/Havells/Bajaj/Crompton/Wipro |
| 85 | Supply delivery, installation, testing & commissioning of following types of 10 watt LED based BULK HEAD with PDC aluminium with CCT:3000K OPAL DIFFUSER complete etc.as required and as per the direction of E.I.C. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 86 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm 1700 cmh air delivery with louvers of exhaust fan in the existing wall, including fixing & conntection complete etc.as required and as per the direction of E.I.C..(Make-USHA (Model.Turbo HDEF 1400 RPM ISI)/Eq. model of /Havells/ ALmonrad/ Crompton |
| 87 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery 215m3/min Make Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg. in Charge,Replacement Warranty will be 4 years.(fan Regulator compatible) . |
| 88 | SF of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make Schneider(Zencelo) legrand( Myrius)/Panasonic (vision) |
| 89 | MAIN - FEDDER PANEL:S/I/T&Commissioning of LT outdoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 65 kA 3P+N type 1+2 SPD with 63 A 4P MCB, C series, 10 kA. Incomer:1 160A 4P MCCB(36KA) with Microprocessor based release having LSING protection and Icu=Ics=Icw for 1 sec with high speed closing feature with earthing, door interlock, automatic safety shutters ,,Bus bar: 04 numbers of 200Amps copper bus bar Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator Outgoing: 5 Nos 63A 4P MCB 10 ka , 5 Nos 63A DP MCB 10 ka ,3 NOS 63 AMP 4P MCCB & Ics = 100% of Icu with all MCCB ,SPD 4 Pole 65 KA type ( 1+2) Instrument- (i) phase indicating lamp with toggle switch & HRC fuse in all the incomers All the feeders shall have ON/OFF/TRIP indication All the outgoing feeders shall have digital ammeter with suitable rating of Class 1 CT as per the feeder rating.(Sicure/L&T/ABB/Schneider/Siemens/Legrand)(iii) All the incoming feeders shall have digital multifunction (Bidirectional ) meter(V+A+F+KwH+KVAR+KVAH+THD+Import/Export |
| 90 | FLOOR PANEL:S/I/T&Commissioning of LT outdoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 80X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 65 kA 3P+N type 1+2 SPD with 63 A 4P MCB, C series, 10 kA. Incomer:125 A 4P MCCB (36 KA) with adjustable thermal setting Ics = 100% of Icu Bus bar: 4 nos. 150 A CU Busbar duly sleeved Instruments: 1 set.LED type phase indicating lamps with control fuses Outgoing : 2 NOS 63 A 4P MCCB (16 KA) with adjustable thermal setting Ics = 100% 2 Nos 40A DP MCB. (10 KA) , Instrument- (i) phase indicating lamp with toggle switch & HRC fuse in all the incomers All the feeders shall have ON/OFF/TRIP indication All the outgoing feeders shall have digital ammeter with suitable rating of Class 1 CT as per the feeder rating.(Sicure/L&T/ABB/Schneider/Siemens/Legrand)(iii) All the incoming feeders shall have digital multifunction (Bidirectional ) meter(V+A+F+KwH+KVAR+KVAH+THD+Import/Export |
| 91 | STREET LIGHT PANEL :S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 32A TPN MCCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 32 A 3P contactor, OLR,RYB,ON,OFF trip indication, Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer.,04 nos 10A 4P MCB,C,10KA as outgoing Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 year of acceptance of materials |
| 92 | CABLE Supplying, laying & testing of following size of PVC insulated XLPE shethed / strip armoured aluminium / Copper conductor power cables of 1100 volt grade laid directly unground with sand cushioning, brick protection, clamped on surface of the walss / columns / existing RCC / inside masonry cable trenches / on the cable tray /throuth G.I Pipes / hume pipes / PVC pipes as the case may be, including cost of shaddles/ clamps/ markers etc but excluding the cost of G.I. Pipes / Hume pipes cpmplete with making good to the damages as required and as per direction of Engineer-in-charge. MAKE: FINOLEX/ KEI/ POLYCAB/HAVELLS/RR CABLE |
| 93 | 3.5 core x 50 sq mm Aluminium armoured Cable.(FOR FLOOR PANEL) |
| 94 | 3.5 core x 25 sq mm Aluminium armoured Cable.(FOR LIFT PANEL) |
| 95 | 3 core 2.5 sqmm control Aluminium armoured Cable |
| 96 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable. |
| 97 | 3.5 core x 50 sq mm brass double compression gland and aluminium lugs |
| 98 | 3.5 core x 25 sq mm brass double compression gland and aluminium lugs |
| 99 | 4 core x 16 sq mm brass double compression gland and aluminium lugs |
| 100 | Supplying,installation,testing & commissioning Of Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. |
| 101 | Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required. |
| 102 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 103 | Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room. |
| 104 | Supplying of following Materials. Supply installation of 33kV 3mm thick Class-C Rubber Mat as per IS-15652 and complete as per direction of Eng-in-charge.(Size-10mx1m) |
| 105 | Danger Board. |
| 106 | Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room.. |
| 107 | Supply and delivery ,installation of 12'' x8'' size ILLUMINATED EXIT SIGNS With 3 hours battery back up including all conection as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-chargeMAKE:COSIGN/EQ |
| 108 | Supply delivery ,installation andcommissioning of LED Sign Board as per below specification of Box type Display Matter:-1-I LOVE MANINAGESWARI TEMPLE (English Letter Red Color) Letter Height 24 Inch.2- (Odiya Letter Red Color) Letter Height 24 Inch3-Government of Odisha,Tourism department Logo (24X24 Inch) ACP Sheet:- Aluminum composite panel sheet(ACP) Outdoor type 3 mm (Viva, Alomax, Imperia Décor, Citi Bond ) Supporting of English Letter.Plastics Sheet: - 3mm Plastics Sheet (Yellow, Red) Color & Raising of 2.5 inch.(Gray) (Acast)L.E.D :- 0.3 to 1.5 Watts (Yellow, Red) Color (Samsung, GE, Osaram, Philips, LG) Power Supply: - SMPS (Switch mode Power Supply), RPS (Regulate Power Supply).In put Voltage 160 to 230 A.C./ Out put Voltage 12/24 Volts D.C. (Samsung, GE, Osaram, Philipes, LG). The panel should be supplied with astronomical timer and contactor for auto ON/OFF . The panel should be supplied with overvoltage and undervoltage relay with 20 kA TYPE 2 SPD.The panel should be outdoor type. The letter structure to be installed on the top of the building. It shall withstand 200 km/hr wind velocity, MS ANGLE with primer and paint as per need for sustainable fixture 2 inch Ms pipe fastened with concerte. The cost is inclusive of all the structures, LED light, timer control panel and all other accessories. Make-Cosign/Sign media |
| 109 | SIGNAGES:-Providing and installing in position the following type of sign boards made out of 3mm thick flexyle photoluminescent based glow in dark sheeting with luminous properties enclosed in a weather proof Uvstabilized film with UV screen printing by imported links pasted over3 mm thick cast acrylic from front side with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use, greenish yellow, glow visible upto 4-6 hr in total darkness.Make-Prolite/Bajaj , |
| 110 | Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge. Make-Safex/Fireshield/Ceasefire/FLAMEKLOG |
| 111 | Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete. Make-Safex/Fireshield/Ceasefire/FLAMEKLOG |
| 112 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 113 | Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature).The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . In case, the distance between ODU and IDU exceeds 3 mtr, then only the item of copper pipe shall be executed without any joint and equivalent mtr shall be deducted from the copper pipe item. 1.5 TR with 5 Star BEE Rating (Hitachi-RAS.V518PCDIBT1/ Toshiba-RAS-18G3KCV5SG/ Voltas-VOLTAS SAC 185INV VECTRA ELEGANT) |
| 114 | Supply and fixing of 4kVA Voltage stabilizer (130-230V) (Make-V-Guard/Microtek) |
| 115 | Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. |
| 116 | Supply,installation & fabrication of MS base frame for outdoor unit and other nesessary material to complete the job. |
| 117 | CCTV Supply, Installation, Testing and Commissioning of 5MP IP Network TDN Low Light IR Fixed Lens Dome/Bullet Camera, 1/2 8 CMOS or better 5MP (2592 x 1944) 25fps or better four stream at various resolution and Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 1/100,000 Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5, V 73.8(dome)/ Field of View FoV H 94.1, V71(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics Video Motion Detection, Tampering, Loitering, Intrusion, People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES 128/256 SSH/Telnet closed Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range 30 C to 60 C. Certifications ONVIF Profile S/G/T compliant CE (EN 50130 4) FCC Part 15 EN 55032 and RoHS (EN63000),NDA,STQC compliant. Make Honeywell Value series/Pelco/Axis/Bosch |
| 118 | Supply Installation Testing AND Commissioning of 5MP IP Network TDN Low Light IR motorized Lens Dome/Bullet Camera 1/2.8 CMOS or better 5MP (2592 x 1944) 25fps or better four stream at various resolution and Frame Rates Min. Illumination required 0.005 lux (color) 0 Lux IR On 3 IR LEDs Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100000 Adavance Video Compression technology such as H 265 HEVC/ H 264 / MJPEG Fixed Lens 2.713.5mm motorized, Field of View FoV H 100 28 5 V73 21 4, BLC HLC WDR 2D/3DNR White Balance Auto/Manual/Day/Night/timing Minimum Edge Intelligence Video Analytics Video Motion Detection Tampering, Loitering, Intrusion, and People Counting 5 Privacy Mask 6 Region Of Intreset Defog HTTPS IP Filter TLS1 2 AES128/256 SSH/Telnet closed Stream Encryption 2TB SD card support PoE (802.3 af) and 12V DC IP 66/67 and IK10 Vandal proof with Die Cast Aluminium Housing Having Operating temp range 30 C to 60 C. Certifications ONVIF Profile S/G/T compliant CE (EN 50130 4), FCC Part 15 EN 55032 and RoHS (EN63000)NDA STQC compliant. Make Honeywell value series/Pelco/Axis/Bosch |
| 119 | Supply Installation testing commissioning of 64 Channel NVR with 8 SATA 384 Mbps incoming bandwidth Up to 8 Megapixels Resolution Display and Recording H 265 video compression technology with real time encoding Full function CMS (Central monitoring software) supported Two way audio supported Dual streaming technology to encode recording stream and network stream separately Supports remote monitoring on Mobile Client Android IOS TCP / IP PPPoE DHCP DNS DDNS UPnP NTP SMTP Time/ Date Alarm Motion Detection and Exact Search (accurate to second Record Snapshot FTP Preset Calling Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous CE FCC RoHS Make Honeywell value series /Pelco/Axis/Bosch |
| 120 | Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba |
| 121 | SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony |
| 122 | SITC of 4 pair Cat6 23 awg U/UTP outdoor double jacketed LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA 568 C.2 and ISO/IEC 11801 Class E 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from 20 to 70 C Cable support Conductor Resistance 9.38 /100m Max Cable support Delay Skew 45 ns/100m Operating Voltage 72V Impedance 100 15 100 MHz. and Propagation Delay 250 MHz 536 ns/100m ETL Verified 4 connector channel performance up to 700 MHz RoHS Compliant. Make Systimax, Legrand, Panduit. |
| 123 | SITC of Cat6 I/O with single Face plate The Outlet shall meet or exceed requirement as per ANSI/TIA 568C 2 ISO/IEC 11801 and EN50173. The information outlet NEXT PSNEXT FEXT ELFEXT PSELFEXT and return loss should be verified for CAT6 250Mhz and CAT6A 500Mhz. The information outlet connector shall be of gold/nickel thickness of gold 0 8 m. The connectors shall be compatible as per IEEE 802 3af standard for POE application. The PVC material of Face plate should complie ABS /UL94 V O certified. Make Systimax Legrand Panduit |
| 124 | SITC of Cat 6 24 port loaded 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make Systimax Legrand Panduit |
| 125 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA 568 C.2 Standard. Supports Data Networks Speeds Up to 10/100 Base T and 1000 Base T. Available In LSZH Jacket Reduced Toxic Gasses Emitted During Combustion RJ45 8P8C 2 FORK 50 Gold Plated Contacts 100 Factory Tested Transparent Boot Cable Assemblies. Make Systimax, Legrand, Panduit(1 mtr length) |
| 126 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA 568 C 2 Standard. Supports Data Networks Speeds Up to 10/100 Base T and 1000 Base T. Available In LSZH Jacket Reduced Toxic Gasses Emitted During Combustion RJ45 8P8C 2 FORK 50 Gold Plated Contacts 100 Factory Tested Transparent Boot Cable Assemblies. Make Systimax Legrand Panduit(2 mtr length) |
| 127 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved ISO 11801 2nd edition/ EN 501731 2002 / IEC 607941/IEC 60793 2 50 class B13 / EN 60793 2 50 class B .3 / ITU Recommendation G 652 D the oder ITU designations A B and C are also fulfilled / OS1/ISO/IEC 24702 2006 cat OS2 also OS1 requirements are fulfilled/IEEE 802 3 2002 incl 802 3ae ) Jacket. Make Systimax Legrand Panduit |
| 128 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19 Dimensions (mm) 430 X 220 X 1U Cold Rolled Steel as Raw Material Consist of Top Cover and Bottom Panel Easy to Assemble and Dissemble Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp 12 Duplex SC or LC Adapter Interface Splice 24 Fibers at Most with 1 Tray Adaptor SM Duplex SC PC Type Pigtail Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR 326 Core . Make Systimax Legrand Panduit |
| 129 | SITC of OFC Patch Cor SM (OS2 Duplex LC SC LC LC PC Type 3M LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber Insertion Loss 0 2 db Max 0 3db/MTRJ Max 0.5db Return Loss Pc 45db UPC 50db APC 60db. Make Systimax Legrand Panduit |
| 130 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear |
| 131 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 380W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP, Netgear |
| 132 | Supply ,installation ,testing & commissioning of 5KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer of 1ph in put to 1 ph output,230V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 26AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for services building |
| 133 | 20 PASSENGER LIFT Supply,Installation, Testing & Commissioning of of 20 Passenger-cum-stretcher lift gearless with Machine room LESS Capacity 1360 kg , travel distance-12-17 mtr ,car size shall be (2400 mm)front to back and (1300mm or more) left to right Elevator with ACVVVF drive/Control for constant load of 1360 kg ARD >=1.25 MPS SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc .All SS materials shall be of grade SS-304 with thickness not less than 1.2mm. Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons (v) provision of flat cat-6 cable for cctv with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room less,scaffolding ,floor cutting including Fireman's switch complete in all respect.The Elevator should be suitable for stretcher lift & physically handicapped person. make:OTIS/Mitsubishi/Johnson/Schindler |
| 134 | Supply,installation,testing and commissioning of 12M high mast shaft in two sections suitable for 55 m/sec wind speed along with head frame, luminaires carriage suitable for 6 luminaires in symmetrical arrangement and other accessories manufactured in factory. ( Bottom 360mm / Top -150mm, 3mm thickness, 445PCD, diameter of base plate 520mm including supplying of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaire & MCB in base compartment are not included and are a part of installation)along with foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template along with Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour.Erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour . Provision of GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. (2nos per mast required) Approved colour after treatment along with provision of masonary pedestal duly finished with plaster and painting with GI pipe for cable entering as required.. (2nos per mast required) (Make:-Bajaj/ Utkarsh/ Vakrangee/RR ISPAT/Valmont |
| 135 | Supply, fitting and fixing Double dome aviation light etc. complete with transportation, T&P and labour charges as per the direction of the Engineer-in-Charge. |
| 136 | PANEL: S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,08 nos 16A DP MCB,C,10KA ,02 nos 16A 4P MCB,C,10KAas outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 137 | SITC of 250W Outdoor Flood LED lights with polycarbonate module lens provided with silicon gasket for efficient ingree protection with silicon potted driver, IP66, IK08 , bottom opening maintanance , LPW not less than 120.Input Voltage: 85-265V AC ,Body : pressure Die cast Aluminium housing designed to act as heat sink for proper heat dissipation, IP66, CRI greater than eual to 70, burning hours 50,000 hrs, pf greater than 0.95, THD less than 10% as per the Drawing for inspection as required Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj as rerquired & as per direction of Engg.-in-Charge.The luminaire should be Replacement Warranty will be 2 years . |
| 138 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 139 | 4 core x 6 sqmm A2XFY |
| 140 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required including the cost of material ,labor T & P as required as EIC. |
| 141 | Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required. |
| 142 | STREET LIGHT Supply of Elegant look 60 W(190lm/W) AIO LED Solar Street lights having extruded alluminium housing 180Wp or more (subjected to final panel backup calculation with dimming profile of 100 output for 2 hrs 90 output for 1 hr 60 output for 1 hr and 50 output for 8 hrs per day. The calculation is to approved by SE Electrical Circle (RandB) and CE Buildings Odisha BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing maintenance free 12.8 volts 96 Ah or more (subjected to final battery calculation with dimming profile of 100 output for 2 hrs 90 output for 1 hr 60 output for 1 hr and 50 output for 8 hrs per day. The calculation is to approved by SE Electrical Circle (RandB) and CE Buildings Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) BMS MPPT charge controller PIR sensor( when there will be no movement the lumens output will be 30 output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components IK 08 and having lumen output of11400 lumens as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their companys letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE Electrical Circle (RandB) and CE Buildings Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) 3 IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 MPPT Efficiency 5. IEC61547 6. IEC61000 3 2 EMC 7. IEC 60598 23 8. IEC 62109 1 ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light )Make (Philips/Panasonict/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect. |
| 143 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 4 mm thick or more base plate as per IS 2062 complete with 4 nos En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg in Charge. |
| 144 | Installation of 60W AIO LED solar street light on 8 mtr octagonal pole. |
| 145 | SITC of Street light- 120W,130 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66, IK 08 roadway luminaire with high power LED as light source with acrylic cover(Make:LT/ /Philips/Wipro/Havells/Crompton/Bajaj/PANASONIC ) (5Years Warranty) |
| 146 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 147 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative DOUBLE arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 148 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 149 | STREET LIGHT: S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 16A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 150 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 151 | 4 core x 10 sqmm A2XFY |
| 152 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 153 | LANDSCAPE LIGHT Supply, Installation, Testing & Commissioning of of IP65 (10-12)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole & PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10%. CRI>70, PF>.95. CCT - 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100-275)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved.Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge. Make-K-LITE/Philips/LT/PANASONIC/Havells/Bajaj/Crompton/Wipro |
| 154 | SITC of high quality spotlight/SPIKE LIGHT, Power:3W, CCT:3000K/5600K/Amber, Protection Rating:IP65 ,additional wall mount yoke arrangements for fixing the lights.Beam Angle15º/25º ,Body:Diecasted/extruded aluminium,Optics Designed to minimize hotspots.Power Input:DC24V (without DC Driver) Make-K-LITE/Philips/LT/PANASONIC/Havells/Bajaj/Crompton/Wipro |
| 155 | SITC of 200W Outdoor Flood LED lights with polycarbonate module lens provided with silicon gasket for efficient ingree protection with silicon potted driver, IP66, IK08 , bottom opening maintanance , LPW not less than 120.Input Voltage: 85-265V AC ,Body : pressure Die cast Aluminium housing designed to act as heat sink for proper heat dissipation, IP66, CRI greater than eual to 70, burning hours 50,000 hrs, pf greater than 0.95, THD less than 10% as per the Drawing for inspection as required Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj as rerquired & as per direction of Engg.-in-Charge.The luminaire should be Replacement Warranty will be 2 years . |
| 156 | OUTDOOR PANEL: S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 16A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 157 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 158 | 4 core x 10 sqmm A2XFY |
| 159 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 160 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required including the cost of material ,labor T & P as required as EIC. |
| 161 | Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required. |
| 162 | Supply, delivery, laying, testing complete as required & as per the direction of Engineer-in-charge of 4 x 10sqmm Al. Ar PVC cable with its protection 40mm dia HDPE (H) pipes with excavation of 750mm deep cable trench in all kinds of soil & rock (other than granite) and back filling with excavated soil from panel to pole. The cable shall have ISI marking and name of the manufacturer on the body of the cable. |
| 163 | DG SET Supply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of 58.5KVA ( Make -Kirloskar / Jakson/TMTL/Mahindra/Captiva/Sterling) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB IV+ norms etc as per following specifications mentioned below. Warrentee period must be 2 years ALTERNATOR:The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21.ENGINE: Diesel Engine start, developing suitable BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 58.5KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 12 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc.01. Exhaust pipe of required size and length with insulation or clading.02. Diesel tank suitable for 8 to 10 Hours running capacity.03. Residential Silencer.04. SMF Batteries with leads as per the Manufacturer standardsAMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors, Switches, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 58.5 KVA DG Set complete with Battery Charger & leads as required. BASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channel and vibration damping arrangement with cushy foor mounting including paintng etc. as required. FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system. , control cable of 15mtr 2.5sqmm 6core , civil foundation work. (The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work) |
| 164 | PH WORK Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes confirming to CPVC/UPVC ASTM-D- 1785/89 (Sch-80) and pipe fittings of the following nominal borewith clamps including making good the wall , ceiling and floor, testing all complete as per specification and direction of the Engineer in charge. |
| 165 | 25 mm CPVC (Sch-80) pipes |
| 166 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/04 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) Ground Floor 25mm UPVC ASTM Pipe |
| 167 | 32mm UPVC ASTM Pipe |
| 168 | 32mm dia HDPE pipe |
| 169 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of E.I.C. |
| 170 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. |
| 171 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. |
| 172 | 15mm dia. C.P angle stop cock (Plaza/Aquatic/Amber/Cera/Kerovit/Hydro/Somany) |
| 173 | 15mm dia CP Pillar cock (Plaza/Aquatic/Amber/Cera/Kerovit/Hydro/Somany) |
| 174 | 15mm dia CP Pillar cock (Jaquar)CON-CHR-021KN |
| 175 | 15mm dia PVC Health faucet.(Plaza/Aquatic/Amber/Cera/Kerovit/Hydro/Somany) |
| 176 | 15mm dia Two way Bib Cock (Plaza/Aquatic/Amber/Cera/Kerovit/Hydro/Somany) |
| 177 | 15mm dia Two way Bib Cock (Jaquar)-CON-CHR-041KN |
| 178 | 15mm CP wall mixture with telephonic shower(3 in 1)(CON-CHR-281KN) |
| 179 | Over Head Shower 100mm dia round with Arm (OHS-CHR1999) + (SHA-CHR-477) |
| 180 | 15 mm dia CP Sink cock(CON-CHR-347FKN) |
| 181 | 25mm dia C-PVC ball valve |
| 182 | 32mm dia C-PVC ball valve |
| 183 | 15mm dia CP Flange |
| 184 | 15mm dia CP Extention Nipple |
| 185 | 125mm CP grating |
| 186 | Corner shelf with Bracket (ACN-CHR-1173) |
| 187 | 25mmx600mm long CP towel rail |
| 188 | CP ring towel rail |
| 189 | CP soap Dish holder (ACN-CHR-1131N) |
| 190 | Soap dispensing with glass bottle(ACN-CHR-1137N) |
| 191 | CP soap holder |
| 192 | 15mm dia PVC inlet connection pipe 0.45m long |
| 193 | 32mm dia PVC waste pipe with brass coupling nut |
| 194 | Supplying all materials, labour, T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701--1996 including cutting holes through the tank and fixing mild steel ltubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting up to a height of 5 meters above ground level and placing the tank to the required position and providing 1st class Fly ash.Brick work in cement mortar (1:6) of 0.46mt. height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C.slab of size 1.60mt.x1.60mt. and 0.10mt. thick, R.C.C.beam of 0.25mt.x0.30mt. and 2.60mt. average length in cement concrete (1:2:4) using 12mm size h.g.chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. |
| 195 | 1000 litre capacity water storage tanks -In 1st floor |
| 196 | Supplying all materials labour Tand P and fitting and fixing U PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non heat application method/as per manufacturers specification testing earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge.110mm dia U PVC SWR pipes(Supreme/Ashirvad) |
| 197 | 75mm dia U PVC SWR pipes(Supreme/Ashirvad) |
| 198 | 110mm dia U-PVC 'P' trap |
| 199 | 110mm dia U-PVC Door Tee |
| 200 | 100mm dia U-PVC Plain Bend |
| 201 | 100mm dia U-PVC Door Bend |
| 202 | 100mm U-PVC Door Cross Tee |
| 203 | 75mm dia U-PVC Door Bend. |
| 204 | 75mm dia U-PVC Plain Bend. |
| 205 | 110mm dia Vent cowl. |
| 206 | PVC Clamp suitable for 75mm to 110mm dia pipe |
| 207 | Supplying all materials,labour T&P and cutting holels through existing brick or laterite masonry wall for taking H.C.I pipes and fittings including making good the damages etc. all complete as per P.H.Specification and direction of the Engineer in charge. |
| 208 | Supplying all materials, labour T&P and and fixing 10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main etc all complete as per the specification and direction of the Engineer in charge |
| 209 | Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Jaquar/Parryware / Hindware make). URS-WHT-13253N Urinal (Back Inlet) |
| 210 | 15mm dia urinal spreader |
| 211 | 32mm dia C.P. dome waste |
| 212 | Supplying all materials,labour,T&P and fixing the following vitreous china wash down water closet(European type W.C.pan) with integral 'P' or 'S' trap to the fllor with wooden plugs and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar(1:1)fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc.all complete as per specification and direction of the Engineer-in-charge. |
| 213 | Supplying all materials labour TAND P and fixing vitreous china water closet squatting pan Indian type WC pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI P or S trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge580mm size Orissa pan (Parryware/Cera/ Nycer Make) |
| 214 | Supplying all materials labour T AND P and fixing the following vitreous china Wash Down Water Closet European type WC pan with integral P or S trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in chargeCascade dual flushset (Hindware)No.92099 |
| 215 | Supplying all materials labour T and P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs screws and cement etc fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws shanks and back nuts of 15mm dia nominal bore fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks (Plaza make)and supply mains for wash basin fixing 32mm dia CP brass waste etc all complete as per specification and direction of the Engineer in charge |
| 216 | Half pedestal Basin(Hindware)No.91049+91115 |
| 217 | Supplying all materials ,labour ,T&P and fixing wash kitchen sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste , fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc. including cutting holes in walls and making good the damages etc.all complete as per specification and direction of Engineer-in-charge |
| 218 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in chargeDesign mirror(Parryware) |
| 219 | Supplying all materials, labour, T&PProviding,fitting & fixing of toilet Cubicle made out of the material and specification as detailed below:(Cubicle)(1000mm(W)81550mm(D)x2003mm(H)Providing Intermediate panel,Plaster & door: The intermediate panel is one continued panel without any joints. All intermediate panel is one continued panel without any joints. All intermediate panels,pilasters and doors shall be 12mm thick with edges chamfered. The solid compact laminate(Phenolic Core board)is based on thermosetting resins,homogeneously reinforced with celluloselfibres. Top surface on both sides is melamine coated which is scratch and impact resistant.Providing Hardware and fixing: All pilasters are to be supported by adjustable foot and non corrosive inserts. Top rail and wall fixing with and exteror polyamid coating quarantees resistance to breakage,heat,humidity and chemicals. The base of the adjustable foot will be anchored to the floor with a clearance height of 100mm. Aluminum U-Channel will be used for the fixing of intermediate panels to the wall.1 unit. |
| 220 | Supplying all materials, labour, T&P and fitting & fixing of toilet front partition size 0.12x0.5 with door made 12mm thick solid compact laminated (Phenolic core board) reinforced with celluse fibres, the partision fixed in wall hanging with clamps complete etc as per specification and direction of the Engineer in charge. |
| 221 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 222 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 223 | Supplying all materials labour T and P and laying in trenches to level or slope unplasticized PVC pipes conforming to IS 4985/2000 of the following outside dia for class 3(0.60mpa) including jointing with supply of approved solvent cement by non heat application method/as per manufacturers specification providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C 1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm all round concrete |
| 224 | 160mm dia u pvc pipe alround concrete |
| 225 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm |
| 226 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, Ground class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm |
| 227 | Supplying all materials, labour, T&P and providing 450mm dia x 50mm thick RCPC man hole cover in cement concrete (1:2:4) using 12mm size h.g chips, placing the cover on the man hole/ inspection chamber and finishing smooth all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in chargeR.C.P.C. Cover(20\\"/22\\" round Man hole cover) |
| 228 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeMan hole chamber Inside size 910mmx910mmx910mm |
| 229 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class Fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.Brick masonry soakway pit 1.40m dia x 2.00m deep |
| 230 | Construction 1 nos 30 users RCC Septic tank Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 231 | - do - with addl. Depth of 1.5 m |
| 232 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge |
| 233 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 234 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 235 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 236 | For RCC wall |
| 237 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 238 | Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 239 | Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge |
| 240 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 241 | Supplying all materials, labour,T&P and providing Vent base in cement concrete(1:2:4) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 242 | Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. |
| 243 | 110mm dia U-PVC Plain shoe bend |
| 244 | 110mm dia U-PVC Cowl |
| 245 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail