Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation in hard soil or gravelly soil including dressing and leveling the bed and disposal of the excavated materials within initial leads and lifts as per direction of E.I.C. |
| 2 | Earthwork in stoney earth and gravels mixed with stone and boulder not exceeding 0.014 cum in volume within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3min depth and as per specification approved by the department |
| 3 | Filling foundation trenches with excavated earth including watering ramming and compacting in layer not exceeding 150 mm thick including labour sundries T & P etc complete and as per direction of Engineer-in- charge |
| 4 | Filling foundation and plinth with sand well watered and rammed including cost conveyance royalty of sand and labour etc complete. |
| 5 | P.C.C. (1:3:6) as per drawing & technical specification including cost of all materials labour T&P etc complete. |
| 6 | Plain Cement Concrete M-20 Grade using 40mm size hard granite H.B. metal approved quality from approved quarry including hoisting laying using concrete mixture and vibrators including cost, carriage, royalty, cost of all labour T.&P. etc complete and as directed by E.I.C. |
| 7 | Providing, lifting, hoisting and laying Reinforoad Comer Concrsis of M-25 grade in Column base, Column Footings, Raft Foundation,Stem of the Columns, beams, chaujja, fin, lintel, stair Case, jali , shelves and slab etc as per approved designs and drawings having a minimum Compressive strength ( in work test) 20N. / Square mm. in 15cm. cubes at 28 days after mixing and test conducted in accordance with 1.S. 456 and 1.S. 516 using screened & washed sharp Hiver sand far mertar and 18mm. to 20 mm. size black hand crusher broken granite stone chips of Spproved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement Including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days including, centering and shuttering then after {dismantfing and removing the debrises away from the work site and finishing the exposed ~ fSurface -smooth. providing grooves-or beads: wherever necessary. including: cost, conveyance, loading, unloading, royalties and taxes of all materials , cost of all labours, scaffolding, sundries,T&P required for the work etc. Complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Stee! and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in. proper position as directed by the Engineer-in-charge. |
| 8 | Plinth Bend |
| 9 | Column Ground Floor |
| 10 | 1st Floor |
| 11 | DRAIN Drain Base |
| 12 | Drain Wall |
| 13 | Drain Slab |
| 14 | Lintel Ground Floor |
| 15 | 1st Floor |
| 16 | Roof Beam Ground Floor |
| 17 | 1st Floor |
| 18 | Roof Slab Ground Floor |
| 19 | 1st Floor |
| 20 | Stair Case Ground Floor |
| 21 | Chajja Ground Floor |
| 22 | First Floor |
| 23 | Coping |
| 24 | Cutting, Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or| jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost,canveyance,loading,..unloading & taxes of M.S PlaiwHYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, TP and Scaffolding complete in alt respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.SPiainHYSD/TMT reinforcement bars consumed in the work only. |
| 25 | First Floor |
| 26 | Fly-Ash Brick masonary with c.m (1:6) in foundation and Plinth using Fly-Ash Bricks 250 x 120 x 80mm size watering ,curing etc complete including cost of materials, labour all comp.complete as per the direction of Engineer-In-Charge |
| 27 | Brick work with Fly Ash bricks 25cm x 12cm x 8cm size having crusing Strength not less then 75kg/cm2 in cement mortar (1:6) in superstructure including all cost complete as per direction of Enginner-In-Charge. |
| 28 | First Floor |
| 29 | Second Floor |
| 30 | Fly-Ash Brick Masonary with C.M (1:4) in Superstructure using Flyash Brick of size 250x120x80mm, watering curing etc complete for the work. |
| 31 | Providing 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to out, Side smooth surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface Smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required omamental finish as per drawing, watering, curing, Scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all Jabour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 32 | First Floor |
| 33 | 16mm thick cement plaster (1:6) on brick work inside wall including all cost conveyance royalty & taxes etc, to work site as per direction of Engineer-In-Charge |
| 34 | First Floor |
| 35 | 6mm thick cement plaster (1:4) over R.C.C surface including all cost and conveyance, royalty, taxes of all materials etc.complete as directed by the Engineer in Charge. |
| 36 | 20 mm thick Ornamental C.P (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment, watering,curing cost, carriage, royalty of all materials, labour, etc. |
| 37 | Providing and Painting wall Surface one coat with Wall Primer to give an even shed before applying weather coat to Exterior walls including cost of Primer , labour, T&P all comp. |
| 38 | Outer side |
| 39 | First Floor |
| 40 | Wall painting 2 coats with weather coat over a coat of primer to inside and out side smooth surface with all cost of labour, T&P material etc complete. |
| 41 | First Floor |
| 42 | Wall painting 2 coats with plastic emulsion paint of approved shade on new work to give an even shade including cost of paint etc complete. |
| 43 | First Floor |
| 44 | Finishing wall surface of walls with Acrylic wall putty (Water based ) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete. |
| 45 | First Floor |
| 46 | Painting two coats to Wooden Work with approved enamel paints over a coat of Primer of approved colour, shade including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge. |
| 47 | Providing,Fitting & Fixing of Granite Stone in Floors, steps &Landing slab over 25mm thick cement plaster in Cement Mortar (1:1) including cost of Tiles, Labour, T&P all comp. |
| 48 | First Floor |
| 49 | Providing,Fitting & Fixing of Tiles in Floors, steps &Landing slab over 25mm thick cement plaster in Cement Mortar (1:1) including cost of Tiles, Labour, T&P all comp. |
| 50 | Supplying, fitting and fixing vetrifed tile in floors of size 600mm x 600mm of approved make with application of polymer modified cement based water resistant adhesive bed of required thickness of 10mm and filling joints with epoxy grout of approved qualiy including cost of all materials, labour T&P etc required for the work. |
| 51 | First Floor |
| 52 | Providing, Fitting & Fixing of Virtified tiles in Walls on 12mm thick Cement Plaster in Cement mortar (1:3) jointed with neat cement Slurry mixed with Pigments including cost of Tiles, labour, T&P all comp. |
| 53 | First Floor |
| 54 | Providing, fitting and fixing the M.S. grills and placing 12mm Sq bars in position including cost, covenyance and royalty of all materials and cost of all labour etc. |
| 55 | Painting two coats to M.S.Grill with approved enamel paints over a coat of Primer of approved colour, shade including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge. |
| 56 | Painting two coats to new Steel work with any approved shade over a coat of primer.including cost of all materials and labour T&p etc. |
| 57 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 58 | Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 59 | Ground Floor |
| 60 | 20mm thick cement plaster 1:4 on roof slab as grading plaster finished smooth including cost of all materials, labour, T&P, etc. complete. (As per A.R. 106/17) |
| 61 | Supplying, Fitting and Fixing of Stainless Steel hand railing using 50mm dia of 2mm thick circular pipe as Balustrade as per approved design and specifications all comp. |
| 62 | Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect onforming to IRC SP-63:2018. |
| 63 | Supplying, Fitting & Fixing khandolite stone in floors approved qualiy including cost of all materials, labour T&P etc required for the work. |
| 64 | Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead |
| 65 | Dismantling and removing R.C.C.column,beam slab,staircase,landing,lintel incl.stacking the useful materials for reuse &removing the debris within 50m. lead etc. complete. |
| 66 | Dismantling brick or stone masonry in lime or cement mortar above 3m. height incl.stacking the useful materials for reuse & removing the debris within 50m. Lead etc. complete. |
| 67 | Dismantling and removing 2.5cm thick grading concrete from roof slab cleaning the surface lowring & removing debris within 50m. Lead. |
| 68 | Dismantling & removing 2.5cm.thick A.S.flooring incl.stacking the useful materials for reuse &removing the debris within 50m. Lead etc. complete. |
| 69 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips complete all as per direction of Engineer-in-Charge. |
| 70 | Providing, Fitting & Fixing of false Ceilling with Aluminium T-Section no-3215 with 0.60m C/C , l-Sections fixed in walls by means of steel screws and pvc plug and the aluminium grid 0.60X0.60M SUSPENDED FROM CELLING ALL COMP. |
| 71 | Windows |
| 72 | Dressed seasoned sal wood (50mm. to 150mm. & upto 2.75m. long.) work framed and fixed (wrought and put up) in trusses, purlins, frames of doors, windows, ventilators and beams |
| 73 | 32MM THICK Piasal wood or local teak wood pannelled shutters moulded panels with all labour, iron fittings,wooden cleats etc |
| 74 | Providing GSB- VI Material as per table 400-2, mixing in a mechanical mix plant at OMC, carraige of mixed Material to work site, spreding in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401SDB. |
| 75 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018. |
| 76 | Supplying and fixing of Pre cast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. |
| 77 | ELECTRICAL WORK FAÇADE LIGHTING Supply installation testing and commissioning of Colour Changing 55W RGBW surface mounted SPOT LIGHT Narrow/Medium beam luminaire suitable for outdoor applications of Facade Lighting Luminaires should be enabled with high power LEDs should consists of anti-aging and anti UV high optical efficiency temperature resistant lenses suitable for architectural lighting as per design requirement.Luminaire should have inbuilt DMX Chip and can be Controlled through DMX/Ethernet protocol using 8 bit DMX 512 Controller Controller can achieve 16.7M colors. Luminaire should be complete with dedicated lens for each LED. DMX enabler circuit should be inside luminaire only.The luminaire should be complete with dedicated Lens for each LED and should have options for various beam angles actual will depend on the design by the contractor and site requirement.Luminaire should be provided with suitable integral/separate non integral power supply unit.Lumen maintenance of at least L70B50 50000 BH (Ta 25 C).The luminaire should have Aluminium Die cast housing powder coated in Shiny Grey with minimum 3 4 mm thick : Toughened Glass.Ingress Protection IP 66 Impact resistance level IK 08. Adequate heat sink with proper thermal management shall be provided. Operating Temperature 10 C to +45 C Operating Humidity 10 90 . THD should be less than 10.Built in Surge protection DM 4kV CM 6KV .Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements.Connectors should have IP67 male/female connectors for DMX through wiring.The LED Luminaires and drivers should be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.LM79 and LM80 reports must be submitted. Make of LED must be validated through LM 79 for each type of fitting. Color rendering index 80 and power factor of complete luminaire 0.90, at white colour.The luminaire manufacturer must be having registered office and having service set up (Toll free base number to be provided )in the state to provide after sales service within 5 years warranty period.Make Leksha lighting/canara Lighting /LT/HALONIX |
| 78 | Supply, installation, testing and commissioning of Colour Changing 100W RGBW surface mounted FLOOD LIGHT Narrow/Medium beam luminaire suitable for outdoor applications of Facade Lighting,Luminaires should be enabled with high power LEDs, should consists of anti aging and anti UV high optical efficiency temperature resistant lenses suitable for architectural lighting as per design requirement.Luminaire should have inbuilt DMX Chip and can be Controlled through DMX/Ethernet protocol using 8 bit DMX 512 Controller, Controller can achieve 16.7M colors. Luminaire should be complete with dedicated lens for each LED. DMX enabler circuit should be inside luminaire only.The luminaire should be complete with dedicated Lens for each LED and should have options for various beam angles, actual will depend on the design by the contractor and site requirement.Luminaire should be provided with suitable integral/separate non integral power supply unit.Lumen maintenance of at least L70B50 50000 BH (Ta 25 C).The luminaire should have Aluminium Die cast housing powder coated in Shiny Grey with minimum 3 4 mm thick Toughened Glass.Ingress Protection IP 66 Impact resistance level IK 08 Adequate heat sink with proper thermal management shall be provided. Operating Temperature 10 C to +45 C, Operating Humidity 10 90 . THD should be less than 10 .Built in Surge protection DM 4kV CM 6KV .Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements.Connectors should have IP67 male/female connectors for DMX through wiring.The LED Luminaires and drivers should be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.LM79 and LM80 reports must be submitted. Make of LED must be validated through LM 79 for each type of fitting. Color rendering index 80 and power factor of complete luminaire 0.90 at white colour.The luminaire manufacturer must be having registered office and having service set up (Toll free base number to be provided )in the state to provide after sales service within 5 years warranty period.Make Leksha lighting/canara Lighting /LT/HALONIX |
| 79 | Supply, installation, testing & commissioning of 30W RGBW LED SPOT LIGHT with following technical features: Aluminium Die-casting body with Surface anodic oxidation and UV stabilized toughened glass front cover, luminary should be linear shaped suitable for illumination of wall facade lighting, Tilt : asper site requirement, IK08 and IP-66 or greater ingress protection for outdoor application suitability,secondary optical lenses provided on each LED of fitting with suitable narrow beam angle, DMX compatibility with inbuilt decoder. Control Mode: DMX512, DMX Controller can achieve 16.7M colors, Rated Input Supply of LED: Highly reliable DC 24V constant voltage power supply which drives the RGBW LEDs High Power LED Power Consumption : 24W to 30W (approx.) per fixture however as per requirement wattage may be increased /decreased to meet the desired effect of Façade. Power Efficiency : >85%, Power factor : >0.9, Operating Frequency: 50 Hz, Operating temperature: -10 to +45 degree centigrade, Life Span : >50000 hours, Product test reports: LM79 & LEDs test report- LM80 shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. The luminaire manufacturer must be having registered office and having service set up (Toll free base number to be provided )in the state to provide immediate after sales service within 5 years warranty period.Make :Make : Leksha lighting/canara Lighting /LT/HALONIX |
| 80 | Supply of Waterproof DMX Power Connectors for Light Fixture |
| 81 | Supply, installation, testing and commissioning of Controller capable of delivering light shows to installationswith up to 2048 unique light addresses. Software light show authoring software along with controller shouldadd new levels of sophistication and flexibility to lighting installations while eliminating the need forexpensive lighting boards and technical programming expertise. It should be compatible for programmingwith PC. There should be provision of MicroSD card. OS requirement for the controller is Windows 7/8/10 or latest version. Easy to use with factory preset shows, custom show authoring capabilities, an intuitive LCD interface,removable SD card storage, and on board light addressing features, controller should enable to spend more time on the creative aspects of lighting design and less time on setup.Packaged with software should light show authoring softwar software should give the flexibility to create and manage light shows using fully customizable effects, multi track editing, timeline layering, and transition styles.The controller should have variety of features including 1024 DMX channels, Ethernet facility, dry contact port triggering and multi zone SD card memory.Control 12 DMX universes controller should have 4 DMX output ports, each controlling a universe of 512 DMX channels. The luminaire manufacturer must be having registered office and having service set up (Toll free base number to be provided )in the state to provide immediate after sales service within 5 years warranty period.Make Leksha lighting/canara Lighting /LT/HALONIX |
| 82 | DMX Slave/ Booster should have a suitable output 8 port DMX/RDM splitter with DMX/RDM pass-throughsupporting bi directional communications for discovery, addressing and DMX control of Architectural lighting products.The unit should take the incoming DMX/RDM signal and split the signal into suitable separate output channels allowing for expanding the number of devices controlled from 32 to 6 X 32 or as per design / site requirement.The output terminals should electronically and optically isolated from the input and RDM through port and share a common ground reference. All output ports should have an independent output driver to boost the DMX/RDM signal. Splitters should be capable to amplify the DMX signal and allowing the data link to be extended by max 70 m (230 ft). DMX/RDM Splitter/ Booster, Isolated DMX/RDM Input/Outputs Surface or DIN rail mountable and AC adaptor included and it should be compatible with façade lighting products.Make Leksha lighting/canara Lighting /LT/HALONIX |
| 83 | PVC Copper unarmoured flexible FRLS insulated multicore cable 1100V grade confirming to IS694 size 3cx1.5 sq mm.Make : SBEE, KEI, Polycab, Walna |
| 84 | PVC Copper unarmoured flexible FRLS insulated multicore cable 1100V grade confirming to IS694 size 3cx2.5 sq mm.Make : SBEE, KEI, Polycab, Walna |
| 85 | Screened 5 core sheilded DMX signal cable for DMX network.Make : Falcon, Belden, |
| 86 | Direct Lighting Distribution Board with TPN incomer of suitable rating and and outgoing SP MCBs of suitable rating Make : Canara, ABB, L&T, Havells |
| 87 | Other accessories like Junction Boxes, nuts bolts clamps, conduits etc required for complete installation of the system |
| 88 | Installation Testing and Commissioining of the system . |
| 89 | PUMP Supplying, installation, testing and commissioning of Electric Motor Driven Pressurization booster Pump having discharge of 450 LPM at 35 Mtr head complete with Pump Set, Electric Motor suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame.Make-Wilo/KSB/Kirloskar |
| 90 | Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1)- 1 nos 63Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.as per direction of engineer in charge Control panel for fire pumps for auto action.make-Legrand/schneider/Siemens/eq. Model of ABB/L&T/Hager/C&S/Havells |
| 91 | 1100 V GRADE POWER/CONTROL CABLES :SITC of FRLS,PVC outer sheateh, steel armoured, aluminium, 1100v grade power cables with glands etc. The minimum size of the cables shall as mentioned below as per direction of engineer in charge.Make-Polycab/Havels/KEI. |
| 92 | Supply,Installation,Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield/Kartar |
| 93 | Supply,Installation,Testing & Commissioning of 20 MM cpvc Drip Irrigation Pipe - 20mm UV Resistant Pipe as mentioned below as per direction of engineer in charge |
| 94 | Toilet Internal Electrification Work Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 95 | GROUUP B |
| 96 | GROUUP C |
| 97 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION) |
| 98 | Supply and fixing of modular metal box on surface or recess with suitable size of modular cover in front including providing an fixing of ISI marked 16Amp modular plug with switch with all conection. on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION) |
| 99 | Supply& fixing of Modular type 6 Amp one way switch and 6 A socket outlet with metal box and modular cover Separate Board on surface or recess including all conection as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION)) |
| 100 | Submains:Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. |
| 101 | 2 x 2.5 sq.mm. + 1 x 1.5 sq.mm. |
| 102 | 2 x 4.0 sq.mm. + 1 x 1.5 sq.mm. |
| 103 | 4 x 6.0 sq.mm. + 2 x 4 sq.mm. |
| 104 | Supplying and fixing of following sizes of medium class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/ BEC/ Precision/ Norpak |
| 105 | 25 MM |
| 106 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 107 | Supplying and fixing 63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 3 years.. |
| 108 | Supplying and fixing 25 Amps rating,C series,10KA breaking capacity, DP, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 3 years. |
| 109 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years. |
| 110 | Fittings & Fixtures Supply of 20 watt Surface mounted indoor type BATTERN LED Luminaire with LED GLARE FREE opal diffuser , IP20 Efficency 120-130lm/w Lamp complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge |
| 111 | SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro |
| 112 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm 1700 cmh air delivery with louvers of exhaust fan in the existing wall, including fixing & conntection complete etc.as required and as per the direction of E.I.C..(Make-USHA (Model.Turbo HDEF 1400 RPM ISI)/Eq. model of /Havells/ ALmonrad/ Crompton |
| 113 | Supplying,installation,testing & commissioning Of Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc as required as per direction of Engg.-in-Charge. The entire earthing system should be Replacement Warranty will be 2 years |
| 114 | Extra for using salt and charcoal for G.I or copper plate earth as required |
| 115 | Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required. |
| 116 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 117 | CCTV CAMERA WITH MONITORING SYSTEM SITC of Bullet Camera of having 4MP resolution H.265 Codec 1/2.8 CMOS Shutter Speed of 1/3s 1/ 1,00,000 2.7 13.5 mm MFZ Lens VariantDC Iris 3DNR;BLC HLC WDR 140 dB 60 Mtr IR,Analytics Motion detection, Smart motion, Tampering, Intrusion, Multi loitering, People counter, Tripwire, Abandoned object, Missing object,Audio detectio ;Audio and Alarm 2 In/1 Out Aluminium housing SD Card Slots 1TB IP67 IK10 Cyber Security TLS1.2 only, Stream encryption, AES 256,Telnet closed, PCIDSS compliance, FIPS Chipset Built In ONVIF Profile G,S,T,M Certificates CE, FCC, RoHS, BIS,UL,05 Yrs OEM Warranty,OEM Authorisation,OEM should have factory in India since 2012 Preffered Make Honeywell/Bosch/Pelco/Hikvision |
| 118 | SITC of Dome 5 MP resolution H.265 Codec 1/2.8 CMOS Shutter Speed of 1/8 1/ 32,000 2.8mm Fix Lens 3DNR BLC HLC WDR 120 dB 40 Mtr IR,Analytics Analytics People Counter, Multi Loitering, Intrusion, Tampering, Smart Motion Detection (SMD), Motion Detect Aluminium housing SD Card Slots 256GB IP67 IK10 TLS1.2 only AES 256 SSH / Telnet closed sFTP by default PCIDSS compliance ONVIF Profile S,T and G Certificates CE, FCC, RoHS, BIS,UL, 05 Yrs OEM Warranty,OEM Authorisation,OEM should have factory in India since 2012 Preffered Make Honeywell/Bosch/Pelco/Hikvision |
| 119 | SITC of 32 Channel NVR Processor :32 ch NVR with ARM Processor, Embedded Linux;8 SATA up to 80 TB inbuilt storage supported ,3 x USB,Mamimum 16 user; 2 Way Audio;LAN x 1, WAN x 1, 2 x HDMI, 1 VGA;RAID 5,Dual Power Supply, Network throughput 400 Mbps ,Support redundancy Failover N+1, RS485 Supported,RS232 Supported,e-SATA Supported,Certificates -CE,FCC,RoHS,BIS,UL ;Preffered Make: Honeywell/Bosch/Pelco/Hikvision |
| 120 | SITC of 8 TB Surveillance Grade Hard Disk for NVR for 30 Days Back up; Make-Seagate/WD |
| 121 | SITC OF CAT 6 CABLE |
| 122 | Supply, Installation, Testing and Commissioning of 55 LED Display Panel, with 4K Resolution 3840 x 2160, 500 nits (cd/m2) Brightness, contrast ratio 4000 1, Viewing Angle 178 h/v, response time 8ms, Display Colors 16.7 Mill Built in Speaker 10W+10W Inputs HDMI x 2, DVI D, DisplayPort, Audio, RS 232 Control, 100 240 VAC 50/60Hz Power Supply, 24x7 Operation Preffered Make LG/Samsung/Panasonic |
| 123 | 50 KVA DG SET Ls. |
| 124 | Transformer work |
| 125 | Office Internal Electrification Work 20% of Civil Work |
| 126 | PH WORK Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes confirming to CPVC/UPVC ASTM-D- 1785/89 (Sch-80) and pipe fittings of the following nominal borewith clamps including making good the wall , ceiling and floor, testing all complete as per specification and direction of the Engineer in charge. |
| 127 | 25 mm CPVC (Sch-80) pipes |
| 128 | In first floor 20 mm CPVC (Sch-80) pipes |
| 129 | 25 mm CPVC (Sch-80) pipes |
| 130 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/04 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) Ground Floor 25mm UPVC ASTM Pipe |
| 131 | 32mm UPVC ASTM Pipe |
| 132 | 1st Floor 25mm UPVC ASTM Pipe |
| 133 | 32mm UPVC ASTM Pipe |
| 134 | 2nd Floor 40mm UPVC ASTM Pipe |
| 135 | 50mm UPVC ASTM Pipe |
| 136 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of E.I.C. |
| 137 | 250 mm thick wall in FF |
| 138 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. |
| 139 | In First floor |
| 140 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. |
| 141 | 15mm dia. C.P angle stop cock (Plaza/Aquatic/Amber/Cera/Kerovit/Hydro/Somany) |
| 142 | 20mm dia CP concealed stop cock(Plaza/Aquatic/Amber/Cera/Kerovit/Hydro/Somany) |
| 143 | 15mm dia CP Pillar cock (Plaza/Aquatic/Amber/Cera/Kerovit/Hydro/Somany) |
| 144 | 15mm dia PVC Health faucet. |
| 145 | 15mm dia Two way Bib Cock (Plaza/Aquatic/Amber/Cera/Kerovit/Hydro/Somany) |
| 146 | Revolving Shower with arm |
| 147 | 25mm dia C-PVC ball valve |
| 148 | 32mm dia C-PVC ball valve |
| 149 | 40mm dia C-PVC ball valve |
| 150 | 50mm dia C-PVC ball valve |
| 151 | 15mm dia CP Flange |
| 152 | 15mm dia CP Extention Nipple |
| 153 | 125mm CP grating |
| 154 | Acryalic Shelf |
| 155 | 25mmx600mm long CP towel rail |
| 156 | CP ring towel rail |
| 157 | CP soap holder |
| 158 | 15mm dia PVC inlet connection pipe 0.45m long |
| 159 | 32mm dia PVC waste pipe with brass coupling nut |
| 160 | Supplying all materials, labour, T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701--1996 including cutting holes through the tank and fixing mild steel ltubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting up to a height of 5 meters above ground level and placing the tank to the required position and providing 1st class Fly ash.Brick work in cement mortar (1:6) of 0.46mt. height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C.slab of size 1.60mt.x1.60mt. and 0.10mt. thick, R.C.C.beam of 0.25mt.x0.30mt. and 2.60mt. average length in cement concrete (1:2:4) using 12mm size h.g.chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. |
| 161 | 1000 litre capacity water storage tanks -In 2nd floor |
| 162 | Supplying all materials, labour, Tand P and fitting and fixing U PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge.110mm dia U PVC SWR pipes(Supreme/Ashirvad) |
| 163 | 75mm dia U-PVC SWR pipes(Supreme/Ashirvad) |
| 164 | 100mm dia U-PVC 'P' trap |
| 165 | 110mm dia U-PVC Door Tee |
| 166 | 100mm dia U-PVC Plain Bend |
| 167 | 100mm dia U-PVC Door Bend |
| 168 | 100mm U-PVC Door Cross Tee |
| 169 | 75mm dia U-PVC Door Bend. |
| 170 | 75mm dia U-PVC Plain Bend. |
| 171 | 110mm dia Vent cowl. |
| 172 | PVC Clamp suitable for 75mm to 110mm dia pipe |
| 173 | Supplying all materials,labour T&P and cutting holels through existing brick or laterite masonry wall for taking H.C.I pipes and fittings including making good the damages etc. all complete as per P.H.Specification and direction of the Engineer in charge. |
| 174 | Supplying all materials, labour T&P and and fixing 10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main etc all complete as per the specification and direction of the Engineer in charge |
| 175 | Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Jaquar/Parryware / Hindware make). URS-WHT-13253N Urinal (Back Inlet) |
| 176 | 15mm dia urinal spreader |
| 177 | 32mm dia C.P. dome waste |
| 178 | Supplying all materials,labour,T&P and fixing the following vitreous china wash down water closet(European type W.C.pan) with integral 'P' or 'S' trap to the fllor with wooden plugs and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar(1:1)fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc.all complete as per specification and direction of the Engineer-in-charge. |
| 179 | Matrix Set -1 (WB 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm) (head)70002 |
| 180 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks (Plaza make)and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge |
| 181 | Supplying all materials ,labour ,T&P and fixing wash kitchen sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste , fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc. including cutting holes in walls and making good the damages etc.all complete as per specification and direction of Engineer-in-charge |
| 182 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in charge. |
| 183 | Supplying all materials, labour, T&PProviding,fitting & fixing of toilet Cubicle made out of the material and specification as detailed below:(Cubicle)(1000mm(W)81550mm(D)x2003mm(H)Providing Intermediate panel,Plaster & door: The intermediate panel is one continued panel without any joints. All intermediate panel is one continued panel without any joints. All intermediate panels,pilasters and doors shall be 12mm thick with edges chamfered. The solid compact laminate(Phenolic Core board)is based on thermosetting resins,homogeneously reinforced with celluloselfibres. Top surface on both sides is melamine coated which is scratch and impact resistant.Providing Hardware and fixing: All pilasters are to be supported by adjustable foot and non corrosive inserts. Top rail and wall fixing with and exteror polyamid coating quarantees resistance to breakage,heat,humidity and chemicals. The base of the adjustable foot will be anchored to the floor with a clearance height of 100mm. Aluminum U-Channel will be used for the fixing of intermediate panels to the wall.1 unit. |
| 184 | Supplying all materials, labour, T&P and fitting & fixing of toilet front partition size 0.12x0.5 with door made 12mm thick solid compact laminated (Phenolic core board) reinforced with celluse fibres, the partision fixed in wall hanging with clamps complete etc as per specification and direction of the Engineer in charge. |
| 185 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 186 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 187 | Supplying all materials, labour, T and P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS 4985/2000 of the following outside dia for class 3(0.60mpa) including jointing with supply of approved solvent cement by non heat application method/as per manufacturer s specification providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C 1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm all round concrete |
| 188 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm |
| 189 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, Ground class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm |
| 190 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeMan hole chamber Inside size 910mmx910mmx910mm |
| 191 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class Fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.Brick masonry soakway pit 1.40m dia x 2.00m deep |
| 192 | Construction of 50 users Brick Septic tank Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 193 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 194 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 195 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
| 196 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 197 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) in F&P including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
| 198 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeR.C.C floor and roof slabs, landings, balconies, projecting sunshades and chajjas up to 4.30m height |
| 199 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 200 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 201 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.12mm thick CP (1:4) on bw- In gf |
| 202 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 203 | Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge160mm U-PVC plain Tee |
| 204 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge. |
| 205 | Construction of 20 users Brick Septic tankEarth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 206 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 207 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 208 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12m size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 209 | Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn F&P |
| 210 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 211 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 212 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs |
| 213 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 214 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 215 | Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge |
| 216 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 217 | Sinking of (200 x150)mm dia bore well - 1 No by DTH method. Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below first level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only |
| 218 | Drilling of 150mm dia bore 45 mtr to 150mtr |
| 219 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from first level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. |
| 220 | Cost of 200mm dia PVC (sch-80) pipe |
| 221 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
| 222 | Supplying all materials, labour, T&P for withdrawing casing pipes from the unsuccessful bore well including all necessary equipment and labour as per direction of the Engineer in charge . |
| 223 | Supplying all materials, labour, T&P and constructing Bore well protection chamber of the inside size 650x650x1000hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4) inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. |
| 224 | Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. 1.50 H.P single phase 3 stage head range 20 to 35 metres, discharge 145 to 110 L.P.M with outlet dia of 25mm |
| 225 | DOL controll pannel |
| 226 | 2.5 Sqmm flat cable |
| 227 | 32mm dia Steel short piece |
| 228 | Steel roop with cover |
| 229 | Well cap |
| 230 | 50mm size CI bracket |
| 231 | 20mm dia rigid UPVC pipe |
| 232 | 32mm Dia brass non return valve(Shakti make) |
| 233 | 32mm dia HDPE pipe |
| 234 | Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail