| 1 | 11 KV line |
| 2 | Pole WPB GI 160x160 mm 9 Mtr |
| 3 | Conductor 55 Sq.mm ACSR Rabbit PVC Insulated |
| 4 | PG Clamp for 55 Sq.mm AAA Conductor |
| 5 | 11 KV Pin insulator polymer |
| 6 | HW Fittings(B&S) 70 KN,3 bolted |
| 7 | Disc Insulator(B&S) 70 KN Polymer |
| 8 | Non metallic Ties 11 KV ( For covered conductor) |
| 9 | Earthing of support(coil type) |
| 10 | Top Channel 100x50x6 mm,9.56 Kg/Mtr |
| 11 | Fish Plate 50x6 mm,2.36 Kg/Mtr |
| 12 | GI nut,bolt & wsher of different sizes |
| 13 | Black Paint |
| 14 | Yellow colour paint for Background |
| 15 | Civil work for 11 KV line |
| 16 | Couping of pole ratio( 1:1.5:3)(500x500x450mm)-6 Nos |
| 17 | Concreting of Pole ratio(1:1.5:3)(500mmx500mmx1500 mm)-6 Nos |
| 18 | 3 Phase LT Line |
| 19 | LT Stay set Complete |
| 20 | 7/12 SWG GI Stay wire,Grade-2 |
| 21 | LT Stay clamp(1.4 Kg/Pair) |
| 22 | LT Stay Insulator |
| 23 | Pole Clamp for Eye hookfor XLPE AB Cable |
| 24 | Eye hook for XLPE AB Cable |
| 25 | Dead end clamp |
| 26 | Suspension clamp with eye hook for AB cable |
| 27 | 3x95+1x70+1x16 Sq.mm AB Cable |
| 28 | 4 Way Service Distribution box with Kit Kat Fuse |
| 29 | Insulated Piercing connector |
| 30 | Danger Plate (LT) |
| 31 | Back clamp For Danger plate (25x3mm ) |
| 32 | Back clamp for Anticlimbing Device(25x3 mm) |
| 33 | GI barbed wire/Anticlimbing device |
| 34 | GI nut,bolt & washer of different sizes |
| 35 | Civil Work for 3 Phase LT line |
| 36 | Fixing of complete LT line stay set |
| 37 | 100 KVA ,11/0.4 KV Sub Station |
| 38 | WPB(GI) Pole 162x152(11 Mtr Long) |
| 39 | Top Channel GI 100x50x6 mm |
| 40 | Fish Plate 50x6 mm,2.36 Kg/Mtr |
| 41 | MU Channel GI 75x40x4.8 mm |
| 42 | Cantilever support angle 50x50x6 mm |
| 43 | 50x6 mm GI Flat for earthing |
| 44 | 100 KVA,11/0.4 KV(Al.) Transformer,BIS,Level-ll |
| 45 | LT Distribution box with MCCB,Aluminium Busbar,2 bay |
| 46 | 55 Sq.mm AAA Conductor |
| 47 | 4Cx 150 Sq.mm LT XLPE cable(Armoured) |
| 48 | AB Switch(11 kV,200 Amp,3 pole,50 Hz) |
| 49 | HG Fuse(11 KV,200 Amp,3 pole) |
| 50 | PG Clamp for 55 Sq.mm AAA Conductor |
| 51 | Disc Insulator (B&S) 70 KN Polymer |
| 52 | HW Fittings(B&S) 70 KN ( 3 bolted) |
| 53 | Lightning Arrester(12 KV,10 KA) Station Class |
| 54 | 11 KV Pin insulator polymer |
| 55 | HT Stay set complete |
| 56 | HT Stay clamp(1.9 Kg/Pair) |
| 57 | HT Stay insulator(Type-C) |
| 58 | 7/10 SWG GI Stay wire,Grade-2 |
| 59 | 40 mmdia Nominal bore GI Pipe |
| 60 | GI nut,bolt & washer of different sizes |
| 61 | GI barbed wire/Anticlimbing device |
| 62 | Back clamp for Anticlimbing Device(25x3 mm) |
| 63 | Danger Plate (HT) |
| 64 | Back clamp For Danger plate (25x3mm ) |
| 65 | Name Plate |
| 66 | Yellow colour paint for Background |
| 67 | Black Colour paint for numbering |
| 68 | Civil work for Sub-Station |
| 69 | Concreting of Pole ratio(1:1.5:3)(500mmx500mmx1800 mm)-2 Nos |
| 70 | Couping of Pole ration(1:1.5:3)(500x500x450 mm)-2 Nos |
| 71 | Fixing of stay set |
| 72 | Construction of earthing chamber |
| 73 | Laying of 4C x 150 mm2 LT XLPE Cable |
| 74 | Supply and erection of GI fencing with Grill gate,metal & sand spreading. Please Enable Macros to View BoQ information |