| 1 | S & F in repair PVC (SWR) Pipes 110mm dia single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed. |
| 2 | S & F in repair PVC (SWR) bends any radius 110mm dia. |
| 3 | M & L for ready mix plain cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate and mixed with 2% integral water proofing compound as in padding over roof slab and benching etc, finished surface even and smooth without using extra cement including demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.NOTE: (i) WPC shall measured and paid seperately. |
| 4 | M&L for readymix plaster of thickness 12 mm to 15 mm on roof finished even and smooth without using extra cement and taking down cement or cement lime plaster, raking out joints and preparing the surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-in-Charge including WPC as per manufacturer's instructions complete all as specified and directed. (Note :- WPC shall be measured and paid separately) |
| 5 | Supply only Integral water proofing compound confirming to IS-2645-2003 of approved make. |
| 6 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position incl reqd pipes/ fittings.exc 250 Ltr but n.exc 500 ltr in capacity (Cleaning repairing, etc. measured separately |
| 7 | S&F in repair float ball 15/ 20/ 25 mm bore high presure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 210 grams) complete all as specified and directed. |
| 8 | S&F in repair PVC water tank cover for 500/ 1000ltrs tanks complete all as specified. |
| 9 | S & F 500 ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) incl 20mm float valve hoisted & fixed in position and incl reqd pipes/ fittings including dismantling water tanks of capacity exc 250 & n. exc 500 ltr complete all as specified and directed. |
| 10 | M & L for cleaning all around at the mouth of existing rain water pipe properly at terrace, wetting and grouting with CM 1:4 and mixed with 3% water proofing compound, area of each grouting n. exc. 0.10 sqm complete all as specified and directed. |
| 11 | M&L for old size brick work with fly ash brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.including demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc all as specified and directed. |
| 12 | M & L for applying two coats of cement based paint on wall surface over a coat of alkali resistant primer including preparing of undecorated surfaces complete all as specified and directed. |
| 13 | S & F mild steel work as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintel hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290, Gde E-165 complete all as specified and directed. |
| 14 | (a) Taking down existing water proofing treatment incl dismantling roof tiles and cleaning of roof surface by washing and rubbing etc. and removing the retrieved material to a distance not exceeding 500m where directed.(b) Providing and applying fibre reinforced liquid applied elastomeric membrane made of PU Poly urethane with self priming in 1:1 ratio and let it dry for 4-6 hrs. Further apply 2 coats of undiluted water proofing treatment fibre reinforced liquid applied elastomeric membrane made of PU Polyurethane in a gap of 4-6hrs. The applied material should have specific gravity of 1.25g/cc with minimum recommended coverage of 2- 2.2 Kg/Sqm in 2-3 coats to built DFT of 1.2mm the cured membrane shall exhibit - 1. ) Tensile Strength ASTM D412 : 1.4-2.5 MPa2.) Elongation ASTM D412 : 400-500%3.) Adhesion Strength : 1.5N/sqm as per ASTM D45414.) Crack Bridging Ability : >3-4mm as per AS/NZS 4548:5:19995.) Water Permeability : NIL as per DIN 1048 (c) Separation layer of geo-textile membrane 40-45gsm with overlaps of 50mm in both directions over the Ist coat when the surface is still tacky. |
| 15 | S & F 25mm dia CPVC pipes SDR 11 & incl Plain CPVC SDR 11 Fittings fixed on walls/ ceiling or laying in floors incl connection to existing pipe and taking up or down existing PLP fittings complete all as specified and directed |
| 16 | M&L uprooting of plants (girth n.exc 20 cm of trunk to any type of plants grown along the pipes or walls chajjas, parapets and roof of building and removing all roots from structure and pouring acid not less than 100 ml for each plant in the roof to avoid further growth and making good the disturbed surface in CM 1:4 or PCC 1:2:4 type B-0 as required at site to match the existing surface and removing the rubbish to a distance n. exc 50m complete all as specified and directed by Engr-in-Charge.NOTE: The work shall be executed up to 15.00m height of bldg with all safety measures and no extra payment shall be paid to contractor on this account. Please Enable Macros to View BoQ information |