Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-05-2026 | AMENDMENT TO BOQ | BOQ | 09-06-2026 |
| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick or concrete surface including racking out joints hacking for keys scrubbing down with water etc.complete all as specified and directed by Engineer in charge. |
| 2 | Dismantaling floor, hearth or wall tiling including cement motar bedding(but not backing) removing servicable tiles to store and rubbish off premises complete all as specified and directed by Engineer in charge. |
| 3 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area exc 1.5 sqm but n.exc 4.0 sqm of any description each, complete all as specified and directed by Engineer in charge. |
| 4 | Taking down shutter of any description exc 1 sqm each and n exc 25 sqm each, complete all as specified and directed by Engineer-in-charge. |
| 5 | Taking down PVC chowkats or frames with shutters (without taking off shutters from the frame) each area n. exc 1.5 sqm complete all as specified and directed by Engineer in charge. |
| 6 | Dismentling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed by Engineer in charge. |
| 7 | Demolition of cement concrete in ground floor and paving n exc 15 cm thickness (below or ground level) complete all as specified and directed by Engineer in charge. |
| 8 | Demolition of brick work/stone masonry built in cement mortar including all quions, arches, pillars, etc but excluding ashlar, facing, dressed stone work and pre-cast concrete articles complete all as specified and as directed by Engineer-in-charge. |
| 9 | M & L for rendering 10mm thick in CM (1:6) on surfaces of brick work/ stone masonry /concrete surface of wall, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. |
| 10 | M&L for Preparation of newly plaster surfaces of wall by hand held sander/ long handle sander including cornices, pilasters etc completed all as specified directed and applying two coat of oil bound distemper over a coat of alkali resistant priming paint with roller finish, over a coat of 3mm thick wall care putty on walls complete all as specified and as directed by Engineer-In-Charge. |
| 11 | M&L for Preparation of old surfaces by complete removal of existing treatment of wall by hand held sander/ long handle sander including cornices, pilasters etc completed all as specified directed and applying two coat of oil bound distemper over a coat of alkali resistant priming paint with roller finish, over a coat of 3mm thick wall care putty on walls complete all as specified and as directed by Engineer-In-Charge. |
| 12 | M&L for rendering 15mm thick in two layers on ext stone masonary/brick/concrete surfaces of wall , 1st layer 10mm thick in CM 1:6 and 2nd layer 5mm thick in CM 1:4 with mixing of WPC for second layer finished fair and even without using extra cement complete all as specified and directed by Engineer-in-charge.(NOTE : Supply only WPC will be measured and paid for separately) |
| 13 | Supply only for integral water proofing compound as per manufactures instruction complete as specified and as directed by Engineer-in-charge. |
| 14 | M&L Preparation of newly plastered surface of wall by hand held sander/ long handle snader including cornices, pilasters etc and applying with airless spray two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete as specified and as directed by Engineer in charge. |
| 15 | M&L for Preparing of old surfaces by complete removal of existing treatment, scraping down, washing, rubbing down and stopping of painted surface of walls & ceiling including roof projection / chajjas and by hand held sander / long handle sander including cornices, pilasters etc (Plastered or unplastered surfaces) and applying Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade on Two coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.9lit/10 sqm complete all as specified and directed by Engineer-in-charge. |
| 16 | M&L for Preparation by hand held sander / long handle sander including cornices, pilasters etc of new plaster on wall completed all as specified and applying three coat of white washing with roller finish complete all as specified and as directed by Engineer-In-Charge. |
| 17 | M & L for rendering 5mm thick in CM (1:3) on concrete surface of ceiling, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. |
| 18 | M&L for Preparation of newly plaster surfaces of ceiling by hand held sander / long handle sander including cornices, pilasters etc completed all as specified directed and applying three coat of white washing with roller finish complete all as specified and as directed by Engineer-In-Charge. |
| 19 | M&L for Preparation of old surfaces by complete removal existing treatment of wall by hand held sander/ long handle sander including cornices, pilasters etc completed all as specified directed and applying two coat of oil bound distemper over a coat of alkali resistant priming paint with roller finish, over a coat of 3mm thick wall care putty on walls complete all as specified and as directed by Engineer-In-Charge. |
| 20 | M&L for peparation of old surface of wall removing nails including scraping down smoke soot, moulds, moss and effloresent salts and trading oil and greasy spots etc by hand held sander/ long handle sander including cornices, pilasters etc (plastered or unplastered surfaces), and applying one coat of oil bound distemper complete all as specified and as directed by Engineer-in-charge. |
| 21 | M&L for peparation of old surface of wall by hand held sander/ long handle sander including cornices, pilasters etc and applying one coat of white wash complete all as specified and as directed by Engineer-in-charge. |
| 22 | M&L for peparation of old surface of ceiling by hand held sander/ long handle sander including cornices, pilasters etc and applying one coat of white wash complete all as specified and as directed by Engineer-in-charge. |
| 23 | M&L for preparation of old wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directd by Engineer-in-charge. |
| 24 | Complete removal of existing roof treatment, removing rubbish off the premises, cleanning the surface and preparing to receive new roof treatment and applying roof treatment as under:- (a) Applying coat of bituminios primer @ 0.40 litre/ Sqm on prepared surfaces and allow to dry(the primer and the membrane to be used shall be of same manufacturer, (b) Supply and laying of minimum 3 mm thick APP modified polymeric membrane weighting not less than 3 KG/ Sqm black finish reinforcement with non woven polyster matt with help of torching with proplane or abutance gas using torch with minimum 75 mm side overlap and 100 mm end overlap. (c) two coat of approved aluminium paint over membrane complete. (d) all overlaps and joints shall be sealed as per manufacturers instruction complete all as specified and as directed by Engineer-In-Charge. |
| 25 | Roughening surfaces of old concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc incl brushing neat cement slurry with 3.0 kg of cement per sq metre complete all as specified and as directed by Engineer-In-Charge. |
| 26 | M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed by Engineer-In-Charge. |
| 27 | M&L for Rendering 10 mm thick in CM(1:3) with using water proofing compound on fair faces of brick work/ Fasia and roof surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer-In-Charge. |
| 28 | M&L 25mm thick PCC 1:2:4, type B0 (using 12.5mm size stone aggregate) as levelling course complete all as specified and as directed by Engineer-In-Charge. |
| 29 | S & F PVC door with chowkhats frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supply & fixing in opening as per specification & drawing complete all as specified and as directed by Engineer-In-Charge. |
| 30 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and as directed by Engineer-In-Charge. |
| 31 | M/L 2nd class Hardwood chowkhats, plain, solid, straight, wrought, framed, rebate on the solid,rounded or chamfered put together with glue pinned at joints complete all as specified and as directed by Engineer-In-Charge. |
| 32 | S&F rolled mild steel in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc, complete, Fe 410-W (Gde E-250) quality A drilled for fixing of steel sheeting or other covering Door etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting of other covering, running rails and guides and hanging ; also fastening and fixing complete all as specified and as directed by Engineer-In-Charge. |
| 33 | M&L for Hold fast for fixing of chowkats and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and as directed by Engineer-In-Charge. |
| 34 | Providing cement concrete 1:2:4 type BO using (12.5mm graded aggregate) in cills, steps, seismic and other similar bands plinth coureses string courses lacing courses parapets and railing copings kneelers apex bed plates kerbs. etc.. water troughs and the like including wethering slightly rounded or chamfered angles and throating complete all as specified and as directed by Engineer-In-Charge.. |
| 35 | S&F for 35 mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides and fitted to chowkhats complete all as specified and directed by Engineer-in-charge. |
| 36 | S&F Glazed and skelton shutters, 35mm thick of second class Hardwood open rebeted and prepared to receive glass, gauge etc ( without sash bars) edhe of franing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc, sizes of menbers of shutters as specified in SSR Part-I, Section 8.24 (a), chemically treated, complete all as specified and directed by Engineer-in-charge. |
| 37 | S&F powder coated anodised aluminium alloy sections 3 tier track sliding windows series B of size 92mm x 31.75mm x 1.2mm and shutter section 18mm x 43mm x 1.30mm weight 0.547 kg/m Jindal or equivalent duly fitted with neoprene beading, glazing clips, tinted glass panes 4.80/5.0 mm nominal thickness, stainless steel wire cloth 0.36 mm dia and average width of aperture 1.4 mm, aluminium alloy handles etc including taking down old window in any size and make. complete all as specified and directed by Engineer-in-charge.Note : rate shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle etc |
| 38 | S&F powder coated anodised aluminium fixed louvered ventilator frame of size 63.5 x 38.1 x 1.01 mm thick or equivalent section fixed in vertical position with aluminium vertical members and half portion to be provided with 4 mm thick pinhead glass and remaining portion to be louvered using 4 mm thick pinhead glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm incl necessary channel frame work, including rubber gasket and aluminium beading including taking down old ventilator in any size and complete all as specified and directed by Engineer-in-charge.Note : rates shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading etc |
| 39 | S & F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-charge. |
| 40 | M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge. |
| 41 | S&F Extruded aluminium alloy handles 125mm long, fabricated type, anodised.complete all as specified and directed by Engineer-in-charge. |
| 42 | S&F in repairs block board 18/19 mm thick grade 2 quality, interior grade, decorative type with veneer/laminated as approved in both face fixed with screws to timber and frame work complete all as specified and directed by Engineer-in-charge. |
| 43 | S&F 30mm width of flap continuous (piano) hinges, mild steel ,bright finish complete all as specified and directed by Engineer-in-charge. |
| 44 | S&F in repairs 300mm mild steel ordinary rat rail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-charge. |
| 45 | S&F in repairs Floor door stopper of aluminium alloy body and tongue, anodised, 140 mm with hard drawn steel spring, fixed in floor in repairs complete all as specified and directed by Engineer-in-charge. |
| 46 | S&F stainless steel wire cloth 0.36mm dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples in any type of windows/doors complete all as specified and directed by Engineer-in-charge. |
| 47 | M&L preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by Engineer in charge. |
| 48 | S & F 100mm Butt hinges, extruded aluminiumalloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and as directed by Engineer in charge. |
| 49 | S&F Aluminium anodised barrel tower bolts, 150mm long, of extruded section complete all as specified and as directed by Engineer in charge. |
| 50 | S&F Extruded aluminium alloy handles 125mm long, fabricated type, anodised complete all as specified and as directed by Engineer in charge. |
| 51 | S&F 250 mm long aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium complete as all specified and as directed by Engineer in charge. |
| 52 | S&F Aluminium anodised 75mm hasp and staple ,safety type with hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed by Engineer in charge. |
| 53 | M & L Non skid coloured ceramic tiles 7-8mm thick area of each tiles exceeding .06 Sqm but not exceeding .11 Sqm, in floors etc. set and jointed in neat cement slurry mixed with water proofing liquid compound and pointed in white or coloured grouting chemical to match, over 15mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer in charge. |
| 54 | M & L Non skid coloured ceramic tiles 7-8mm thick area of each tiles exc 0.18 Sqm but not exceeding .38 Sqm, in floors, skirting etc. set and jointed in neat cement slurry mixed with water proofing liquid compound and pointed in white or coloured grouting chemical to match, over 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-charge. |
| 55 | M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, incl 20 mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-charge. |
| 56 | M&L for Machine cut kota stone slab 18-20mm thick in stair treds, bathroom patforms, shelf platforms etc, bedded and jointed with grey cement slurry mixed with pigment to match the shade colour of slab including rubbing and polishing complete over and including ,15mm thick screed bed in CM (1:4) and polishing complet all as specified and directed by Engineer-in-charge. |
| 57 | M&L for Machine cut kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar etc, bedded and jointed with grey cement slurry mixed with pigment to match the shade colour of slab including rubbing and polishing complete over and including ,10mm thick screed bed in CM (1:3) and polishing complete all as specified and directed by Engineer-in-charge. |
| 58 | Moulding to Granite/kota stone (single or double) slab including rounding off edges for 20 mm thick slabs including grinding and polishing complete all as specified and directed by Engineer-in-charge. |
| 59 | M&L Glazed ceramic coloured designer tiles in vertical surface 350x250x7mm/450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick rendering in cement mortar (1:3) complete all as specified and directed by Engineer-in-charge. |
| 60 | M&L 75 mm thick Cement concrete type C-2, 1:3:6 (40 mm graded aggregate) as in plinth protection, Subbase complete all as specified and directed by Engineer-in-charge |
| 61 | Taking up or down 25 mm or 32mm bore steel water tubing and connection pipe from wall and floor complete all as per directed including cleaning for refixing or removal from site complete all as specified and directed by Engineer-in-charge |
| 62 | Supply and laying of 25mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fitings, connected joint with CPVC adhesive taflon tape in any requirment complete to walls and ceilings or laid in floorss including all connected brass CPVC fitting sand cutting grooves filled with CM (1:6) complete all as specified and directed by Engineer-in-charge |
| 63 | Taking up or down 20mm bore steel water tubing and connection pipe from wall and floor complete all as per directed including cleaning for refixing or removal from site complete all as specified and directed by Engineer-in-charge |
| 64 | S & F of 20mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fitings, connected joint with CPVC adhesive taflon tape in any requirment complete to walls and ceilings or laid in floors including all connected brass CPVC fitting sand cutting grooves filled with CM (1:6) complete all as specified and directed by Engineer-in-charge |
| 65 | Taking up or down 15mm bore steel water tubing and connection pipe from wall and floor complete all as per directed including cleaning for refixing or removal from site complete all as specified and directed by Engineer-in-charge |
| 66 | S & F of 16mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fitings, connected joint with CPVC adhesive taflon tape in any requirment complete to walls and ceilings or laid in floors including all connected brass CPVC fitting sand cutting grooves filled with CM (1:6) complete all as specified and directed by Engineer-in-charge |
| 67 | Dismantling water tanks and removing to store capacity exc 250 & n.exc 500 ltrs complete all as specified and directed by Engineer-in-charge |
| 68 | S&F 500ltr capacity HDPE three layer rotational moulded polyethylene water storage tanks with UV resistance, advanced storage solutions featuring distinct layers for durability, temperature control and hygiene (white colour) (cylindrical vertical with closed top) hoisted and fixed in position with 20mm ball/float valve complete all as specified and directed by Engineer-in-charge |
| 69 | S&F in repairs 20 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe/upvc pipe complete all as specified and directed by Engineer-in-charge |
| 70 | S&F in repairs fancy type bib taps cast copper alloy 15mm dia chromium plated, fancy type, long body, concealed type with crutch or butter fly handle, screwed down, screwed for iron pipe incl female brass threaded adaptor on CPVC pipes complete all as specified and directed by Engineer-in-charge |
| 71 | S&F in repairs Fancy type stop valves angle/concealed 15 mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions and fixed incl female brass threaded adaptor on CPVC pipes complete all as specified and directed by Engineer-in-charge |
| 72 | S & F in repair 15mm fancy type pillar taps, cast copper alloy, with long heads, chromium plated , screwed down high pressure, with or without lettered 'Hot or Cold ' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed cop complete all as specified and directed by Engineer-in-charge |
| 73 | S&F in repairs 600mm long PVC connection tubes 15mm Size with brass nuts. as selected, complete all as specified and directed by Engineer-in-charge |
| 74 | S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed by Engineer-in-charge |
| 75 | S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-charge |
| 76 | S&F in repairs PVC (SWR) junction single, (single T), equal or unequal 110mm bore provided wit access door complete all as specified and directed by Engineer-in-charge |
| 77 | S&F in repairs PVC(SWR) bend any radius,110 mm dia.provided with access door complete all as specified and directed by Engineer-in-charge. |
| 78 | S&F in repairs PVC(SWR) pipe 75 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed by Engineer-in-charge |
| 79 | S&F in repairs PVC(SWR) pipe 75 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-charge |
| 80 | S&F in repairs PVC(SWR) bend any radius,75 mm dia.provided with access door complete all as specified and directed by Engineer-in-charge. |
| 81 | S&F in repairs PVC(SWR) Tee any radius, 75 mm dia providedwith access door complete all as specified and directed by Engineer-in-charge. |
| 82 | M&L for PCC 1:2:4 type B-0 using (12.5 mm graded stone aggregate) sub base of floors, mass concrete complete all as specified and directed by Engineer-in-charge. |
| 83 | Supply and fix in repair 75 mm bore PVC (SWR) plain floor trap with CP grating complete all as specified and directed by the Engr-in-Charge. |
| 84 | S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and plastic water closet seat cover black closed pattern with flat bottom and cover and mild steel hinging device complete all as specified and directed by Engineer-in-charge. |
| 85 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer-in-charge. |
| 86 | S&F in repairs 10 litre capacity PVC flushing cistern (white), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete all as specified and as directed by Engineer in charge. |
| 87 | S&F in repair Vitreous china wash basin, white , flat back , size 550 x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets fixed, including waste coupling of PTMT 32mm dia (half or full threaded). (Minimum weight 45gms, washer and brass chromium plated bottle traps for wash with inlet and outlet screws for pope or connections including mecessary packing , union and cap and fixed complete all as specified and as directed by Engineer in charge. |
| 88 | S& F in repair Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx 460mm bowl size 410mm x 330mm x 160mm complete including removing existing sink complete all as specified and directed by Engineer-in-charge. |
| 89 | S&F in repairs glass corner shelf 300 mm (with ABS Bracket 300x 600) as selected including removing existing shelf ,complete all as specified and directed by Engineer-in-charge. |
| 90 | S & F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated braket guard and railing 60cm long complete all as specified and as directed by Engineer in charge. |
| 91 | S&F in Repairs Soap Dish of any type (S/S) approximate size 160x160 fixed to plugs with chromium plated brass screws as selected including old shop dish ,complete all as specified and as directed by Engineer in charge. |
| 92 | S&F in repair Brass chromium plated Tublar towel rail 20mm dia D type 60 cm long between flanges complete as specified and as directed by Engineer in charge. |
| 93 | S&F in repair 600 X 450 mm bevelled edge miror of selected guality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with CP brass screws and cup washer complete as specified and as directed by Engineer in charge. |
| 94 | S&F in repair 125 mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union,complete all as specified and directed by Engineer-in-charge. |
| 95 | S&F in repairs 25mm SS curtain rail, cut in required length and size to fit with opening incl fixing on bracket with necessary screws fitted on bracket and decorative nobs on sides with necessary arrangement complete all specified and as directed by Engineer-in-charge. |
| 96 | S&F in repairs curtain rod side brackets of stainless steel, angular, or cantilever type fixed to wall with 02 Nos screws on each bracket and fitted screws for fixinng curtain rod incl CP/stainless steel carved decorative design plain metal colour nobs with fixing arrangement for curtain rod using a screw complete all as approved and shown by Engr-in-charge. |
| 97 | M&L for racking of cracks upto 5 mm wide ,preparation and crack filling with ready to use crack fiber reinforced filler /chemical based crack fillers by approved manufacturer and filling as per manufacturer instructions in walls,roofs of any type or size complete all as specified and directed by Engineer-in-charge. |
| 98 | M&L for racking of cracks exc 5 mm but not exc 10mm wide ,preparation and crack filling with ready to use crack fiber reinforced filler /chemical based crack fillers by approved manufacturer and filling as per manufacturer instructions in walls,roofs of any type or size. complete all as specified and directed by Engineer-in-charge. |
| 99 | M&L 15mm thick rendering in cement plaster 1:3 with WPC on bottom and side walls of sunken floor incl finished even and smooth w/o using extra cement complete all as specified and as directed by Engineer in charge. |
| 100 | Removing the plant/growth of any description size, any location of external surfaces of walls shafts by cutting & remvoing the roots completely spraying the suitable chemical (each plant 100 ML) in the removed portion to avoid re-growth & making good damaged portion to match the existing surfaces by PCC type B0 (1:2:4) 12.5 mm graded aggregate complete all as directed by Engr In Charge (Chemical :- Gramzone/Roundup or equavalent suitable chemical to remove/destroy the plants/roots) |
| 101 | Removal of all loose/unsound/bad/damaged concrete or plaster existing RCC structure of slab/beams/walls/chajja by using chesel/hammar .Cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement . clean loose rust from bars manually with brush . fixing new supplymentary bars if required,either by tying it with existing bars or by welding on it. Applying eppoxy bonding agent and making good with polymer modified plaster/micro concrete as required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface in ground floor including formwork complete all as specified and directed by Engineer-in-charge. |
| 102 | M&L Cleaning vertical and horizontal surfaces of sunken slab using wire brushing followed by sanding with emery paper for loose materials/dust and applying two coats of epoxy resin component (Dr. Fixit DAMPGUARD or equivalent) solution/mix using nylon brush pouring Base part in appropriate container followed by the Hardner part and mix thoroughly to attain homogeneous smooth paste and dilute the mixed compound with water in ratio 1 part Base: 1 part Hardner: 1 part water by slow addition and mix thoroughly until a brushable consistency is obtained, first coat will be allowed to dry for 6 to 8 hrs before application of second/final coat) incl curing treated surface for 24 hrs complete incl applying evenly a coat of blown bitumen @ 1.5kg/sqm over entire treated surfaces incl spout holes complete and all as specified as per manufacturer instruction complete all as specified and directed by Engineer-in-charge. |
| 103 | M&L for 40 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate mixed with liquid water proofing compound as per manufacture instruction in bottom of sunken floors floors complete all as specified and directed by Engineer-in-charge.. |
| 104 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth on brick walls complete all as specified and directed by Engineer-in-charge. |
| 105 | M&L for Brickwork with fly ash moudular bricks built in CM (1:4) , straight or curved on plan exc 6m mean radius, complete all as specified and directed by Engineer-in-charge. |
| 106 | S&F in repairs 2 in 1 wall maounted mixer (15 mm bore) with quater turn fittings and provision for overhead shower with 115 mm bend pipe and wall flange, cast copper alloy with capstan heads, fancy type chromium plated (robotic electroplating for everlasting lustrous shine) with 2 water volume adjustment knobs one both side to control the flow of temperature ,screwed down, screwed for iron pipe or for brass ferrule and fixed includng neccesary fittings complete for mixing hot and cold water for tap and shower complete all as specified and directed by Engineer-in-charge. |
| 107 | Refixing of shutters of any description exc 1.0 Sqm but n exc 2.0 Sqm to same opening with necessary welding/ scres as per site requirment complete all as specified and directed by Engineer-in-charge. |
| 108 | S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and directed by Engineer-in-charge. |
| 109 | Demolition Cement Concrete (reinforced) in roofs, floors (other than ground floors), beams, shelfs, staircases landing, chajjas and similar suspended work complete all as specified and directed by Engineer-in-charge. |
| 110 | M&L RCC 1:2:4 type B-1 (20mm aggregate) nominal mix as slabs supported on walls, beams and colomns in floors, roofs etc. complete all as specified and directed by Engineer-in-charge. |
| 111 | M&L for formwork to flat soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-charge. |
| 112 | S&F Mild steel bars (TMT bars) 10mm and above, cut to length, bent to shape required, including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-charge. |
| 113 | Dismentling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-charge. |
| 114 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-charge. |
| 115 | M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engineer-in-charge. |
| 116 | Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exc. 1.5 mtr deep for laying of cables and getting out soft/loose soil complete all as specified and directed by Engr in Charge |
| 117 | M & L filling dry and clean sand in trenches for cable 8 cm deep below and 15 cm above for cable cushioning complete all as specified and directed by Engr in Charge |
| 118 | Supplying and laying un-reinforced precast concrete cable cover, LV low voltage type -I flat size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-In-charge. |
| 119 | Returning filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in trenches complete all as specified and directed by Engr in Charge |
| 120 | Removal of surplus soil obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr in Charge |
| 121 | M & L for XLPE insulated screened PVC bedded galvanised steel strip or wire armoured UG heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area of 25 sqmm 4 core size laid in trenches under floor/roads/hard standing along poles etc complete all as specified and directed by Engr in Charge. |
| 122 | Supply and fixing GI pipe light grade 40 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah including taking down old unserviceable GI pipe complete all as specified and directed by Engr-in-Charge . |
| 123 | Taking up/down GI tubing and connections 20mm size of pipes including all fittings complete all as specified and directed by Engineer-in-charge. |
| 124 | Taking up/down GI tubing and connections 25mm size of pipes including all fittings complete all as specified and directed by Engineer-in-charge. |
| 125 | S&F tube GI medium grade 20mm dia with all fittings laid in trenches complete all as specified and directed by Engineer-in-charge. |
| 126 | S&F tube GI medium grade 25mm dia with all fittings laid in trenches complete all as specified and directed by Engineer-in-charge. |
| 127 | S&F gun metal valvs with iron wheel head ,screwed both ends for iron pipe and fixed of size 20 mm complete all as specified and directed by Engineer-in-charge. |
| 128 | Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed by Engineer-in-charge. |
| 129 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed by Engineer-in-charge. |
| 130 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed by Engineer-in-charge. |
| 131 | Taking down existing geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to MES store yard of AGE E/M Jamnagar complete all as specified and directed by Engineer-in-charge. |
| 132 | Taking down ceiling fan/ Exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M Jamnagar complete all as specified and directed by Engineer-in-charge. |
| 133 | Taking down existing energy meter from site and deposit to MES storeyard and refixing the same meter after completion of work complete all as specified and directed by Engr-in-Charge. |
| 134 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- |
| 135 | (a) One light point controlled by one, one way switch 5 Amps |
| 136 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 137 | (c) One light point controlled by one, two way switch 5 Amps |
| 138 | (d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 139 | (e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 140 | (f) One bell point controlled by one, bell switch 5 Amps |
| 141 | Description all as per item No 134 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. (power point) |
| 142 | Description all as per item No 134 here in before but using 4.0 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 15 amps switch socket cobmination point including necessary running of 4.0 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. (power point) |
| 143 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and,cutting chases for concealed water,tubing or concealed conduit wiring,,etc., and making good, cutting not,exc 10 cm girth ®(stone massonary) complete all as specified and directed by Engineer-in-charge. |
| 144 | S & F for modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and directed by Engineer-in-charge. |
| 145 | S & F for modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified and directed by Engineer-in-charge. |
| 146 | S & F for modular switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified and directed by Engineer-in-charge. |
| 147 | S & F for modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed by Engineer-in-charge. |
| 148 | S & F for modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed by Engineer-in-charge. |
| 149 | S & F for modular step type fan regulator (BLDC) 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and directed by Engineer-in-charge. |
| 150 | S & F for Bell push modular 6 Amps single module complete all as specified and directed by Engineer-in-charge. |
| 151 | S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and directed by Engineer-in-charge. |
| 152 | S & F for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and directed by Engineer-in-charge. |
| 153 | S & F for lamp holder, PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed by Engineer-in-charge. |
| 154 | S & F for ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and directed by Engineer-in-charge. |
| 155 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and directed by Engineer-in-charge.. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 156 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and directed by Engineer-in-charge. Note:- Two runs of 4 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit |
| 157 | S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed by Engineer-in-charge. |
| 158 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed by Engineer-in-charge. |
| 159 | S & F for MCB Tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and directed by Engineer-in-charge. |
| 160 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and directed by Engineer-in-charge. |
| 161 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and directed by Engineer-in-charge. |
| 162 | S & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1 (5 star rated) as per BIS with blades, down rod & other necessary accessories with brushless direct current motor (BLDC) with out remote system and electrical connections from ceiling rose to fan teriminal complete all as specified and directed by Engineer-in-charge. |
| 163 | S & F for Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap of make Bajaj, Havells, HPL complete all as specified and directed by Engineer-in-charge. |
| 164 | S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired with warranty option of 5 years from date of installation and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and directed by Engineer-in-charge. Make :- Bajaj Cat No BIBWP 10W LED or its equvalent in Philips, Wipro. |
| 165 | S & F for LED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed by Engineer-in-charge. |
| 166 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed by Engineer-in-charge.. Make :- Make Bajaj Cat part No BCLAB 20W WH LED P, Wipro Cat part No LL20-281-XXX065-ALI or its equvalent in Philips, Havells. |
| 167 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make :- Bajaj Cat part No ENXT P 24L WH CR PC SD (Edge plus series) or its equvalent in Philips, Wipro. |
| 168 | S & F for energy efficient exhaust fan of 230 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted). |
| 169 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| 170 | S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engineer-in-charge. |
| 171 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail