| 1 | M & L for vitrified double charge tiles light shed 10 mm thick ( square or rectangular) polished, area of each tiles exc 0.36 sqm but not exc 0.42 Sqm each in floors etc. set and jointed with cement and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with CM 1:4 complete all as specified and directed. |
| 2 | M & L coloured Non Skid ceramic coloured jointless tiles (square/rectangular) area of each tile exc 0.06 Sqm but not exc. 0.16 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer with CM 1:6 complete all as specified and directed. |
| 3 | M & L coloured digital Glazed ceramic coloured tiles in vertical surfaces 300*450 mm 7-8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 5 | S & F 18/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work in cup board and pelmet boxes etc. complete all as specified and directed. |
| 6 | S & F continuous (Piano) hinges,mild steel, bright finish or electro galvanised, width of flaps (when open) 30 mm complete all as specified and directed. |
| 7 | M & L for 30 mm thick Flush shutters, solid core construction, with block board core and 5 mm thick plywood face panels on both side, commercial type on both sides covered face veneered decorative complete all as specified and directed.. |
| 8 | M&L for Glazed and skeleton shutters 35mm thick, 2nd class hardwood open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified, supplied and fitted to chowkats complete all as specified and directed. |
| 9 | M & L for pressed steel door frame size 165 mm x 60 mm made of 1.25 mm thick sheet including necessary fixing lugs, hinges, lock strike plate etc., complete all as specified and directed. |
| 10 | M&L for providing PCC 1:3:6, type C-0 (using 12.5 mm graded stone aggregate) as in filling of pressed steel door frame and holdfasts including necessary formwork complete all as specified and directed. |
| 11 | S&F in Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.18mm and fixed with beeding/Staples complete all as specified and directed. |
| 12 | S&F 4mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares of any size n. exc 0.50 Sqm each complete all as specified and directed |
| 13 | S&F 4mm thick figured glass pin head type and glazing with oil putty or wooden beads in squares n exc 0.50 Sqm each pane complete all as specified and directed. |
| 14 | S&F in repair 20-25mm bore cut to length as required mild steel chromium plated decorative draphery rods as required of colour as selected & directed |
| 15 | S&F in repair 20-25mm bore dia mild steel chromium plated decorative brackets and finails as required of colour as selectedcomplete all as specified and directed. |
| 16 | S&F in repair 15 mm dia bore bib taps, cast copper alloy chromium plated fancy type with crutch alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed. |
| 17 | S&F in repair 15 mm dia stop valves/angle valve, cast copper alloy,fancy type chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions.complete all as specified and directed. |
| 18 | S&F in repair PVC connections 15mm size with PTMT nuts of length 600 mm all as specified and as directed. |
| 19 | S&F in repair 25 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed |
| 20 | S&F PVC waste pipe size 32 mm X 800 mm flexible with coupling for Urinal/WHB/Sink etc. complete all as specified and directed. |
| 21 | S & F in repair 100 mm/ 125mm dia mild steel chromium plated grating (double Q) fixed on floor trap / nahani trap in Cement mortar 1:6 , complete all as specified and directed. |
| 22 | S & F Male Brass Threaded Adaptor (MTA/ MBTA/Female Brass Threaded adaptor (FTA/ FBTA) 20 mm dia complete all as specified and directed. |
| 23 | S & F Supplying and laying of CPVC pipes 20 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed |
| 24 | S & F Supplying and laying of CPVC pipes 25 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed |
| 25 | Taking up or down steel tubing of 15 mm dia and connections, including cleaning for re fixing or removal to store complete all as specified and directed. |
| 26 | Taking up or down steel tubing of 20mm dia and connections, including cleaning for re fixing or removal to store |
| 27 | S & F in repair rotational three layer moulded polyethylene water storage tanks (cylinderical vertical with closed top) capacity 1000 Ltr hoisted and fixed in position all as specified and directed |
| 28 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 29 | M&L Brick work using old size bricks with fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 30 | Taking down cement plaster any description on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 31 | M&L for rendering 10mm thick internal surfaces on fair faces of brick work in cm 1:6 as directed |
| 32 | M&L for rendering 15mm thick external surfaces on brick/concrete in CM 1:4 finished even and fair without using extra cement with WPC 2% by wt of cement. Note:-WPC measured and paid separatly |
| 33 | M&L for applying 1.50 mm thick wall care putty in two coats incl preparation of newly plastered wall surfaces complete all as specified and directed. |
| 34 | M&L for applying 1.50 mm thick wall care putty in two coats incl preparation of old plastered wall including complete removal of existing treated surfaces complete all as specified and directed. |
| 35 | M&L for applying two coat of acrylic distemper over a coat of primer incl preparation of new plastered wall surfaes complete all as specified and directed. |
| 36 | M&L for rendering 10 mm thick in ceiling on brick work or concrete surfaces in CM 1:4, finished even and fair complete all as specified and directed. |
| 37 | M&L for applying two coat of acrylic distemper as in ceiling incl removal of existing treatment of old treated ceiling surfaces complete all as specified and directed. |
| 38 | M&L for applying two coat of acrylic distemper as in ceiling new treated ceiling surfaces |
| 39 | M&L for two coat cement base paint over a coat of primer including preparation of newly plastered external wall surfaces complete all as specified and directed |
| 40 | Demolition of Concrete in ground floors and pavings including floor tiles n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 41 | M & L for Cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate), 25 mm thick in flooring etc complete all specified and as directed |
| 42 | M & L for 75 mm thick Cement concrete type C- 1, 1:3:6 (20mm graded aggregate) as in sub base |
| 43 | M & L two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of new steel surfaces complete all as specified and directed. |
| 44 | M & L two coats of synthetic enamel painting on wooden surfaces exc 10 cm width or girth over one coat of pink primer including preparation of new wooden surfaces. |
| 45 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipe etc complete all as specified and directed. |
| 46 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe etc complete all as specified and directed |
| 47 | Demolition and breaking up drain pipes upto 100 mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar |
| 48 | S&F PVC (SWR) bends ISI marked any radius of 110 mm bore with access door complete all as specified and directed. |
| 49 | S&F PVC (SWR) bends ISI marked any radius of 75 mm bore with access door complete all as specified and directed. |
| 50 | S&F PVC (SWR) junction single, (single T) equal or un equal of 110 mm bore of pipe with access door complete all as specified and directed |
| 51 | S & F of PVC (SWR) vent cowl for 110 mm bore pipe |
| 52 | S&F Aluminium handles cast type anodised handles, D shape of size 150mm complete. ISI marked |
| 53 | S & F as in repair alluminum alloy, anodised, cast type or extruded section, sliding door bolt with hasp & staple (bolt type) with fixing clips and bolts and 300 mm long complete all as specified. |
| 54 | S & F Powder coated aluminium frame/shutters for windows, ventilators sliding/openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws, etc complete all as specified. Make : JINDAL/HINDALCO/INDALCO. Note : (i) Glazing and wire mesh shall be measured and paid separetely only as the labour element included in the relavent item.(ii) Item shall be paid as per weight of aluminium section (iii) The rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight (iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. |
| 55 | Dismantling of asbestos cement (corrugated, semicorrugated etc,) sheets in roof coverings. |
| 56 | S & F Pre- painted galvalume aluminum zinc coating (AZ 150) GI based corrugated steel sheet 0.50mm thick, coloured having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws at every alternate corrugations as specified and directed. |
| 57 | S & F pre-painted galvalume aluminum zinc coating (AZ 150) GI based plain steel sheet 0.5mm thick of any coloure in ridge having tensile strength of 550 Mpa fixed with self tapping screws as complete all as specified and directed.. |
| 58 | S&F of Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing including distance pieces, cleats etc Fe 410 W (Gde E - 250 quality). |
| 59 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 60 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 61 | S & F in repair vitreous china wash basin oval shape white flat back size 550 x 400mm waste, chain & plug and porcelain stopper but including brackets or fixed to walls with anchor fastners all as specified and directed |
| 62 | S & F of Vitreous China wash down water closet pan (pedestal pattern), white including fixing bolts, but excuding flushing cistern and flush pipe complete all as specified and directed. |
| 63 | S & F as in repair 10 litre PVC valveless, syphonic action type, Dual type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 64 | S & F mild steel butt hinges, medium weight cold rolled of size 100 mm . |
| 65 | S & F 150 mm long aluminium anodised barrel tower bolt of extruded section |
| 66 | S & F 200 mm long aluminium anodised barrel tower bolt of extruded section |
| 67 | Taking down chowkhats or frames not exc 1.5 Sqm ( without taking shutters from the frame). |
| 68 | Taking down chowkhats for frames exc 1.5 Sqm but n exc 4.00 Sqm (without taking shutters from the frame). |
| 69 | M & L for 12 mm thick dark shed endura parking tile (square/rectangular) area of each tile exc 0.09 Sqm but not exc. 0.16 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over complete all as specified and directed |
| 70 | M&L for 15mm thick screed bed or bedding layer with CM 1:6 complete all as specified and directed |
| 71 | M & L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded aggregate as in plinth protection and finishing surfaces even and smooth without using extra cement. complete all as specified and directed. |
| 72 | S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet & edges will be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing |
| 73 | S & F Solid PVC factory made Door shutter of 30mm (style) consisting of frame made out of MS tubes for top bottom rails MS frame shall be covered with heat moulded plain coloured PVC 'C' channel having a PVC sheet strip 20mm width stuck inside with solvent cement for stilesa and plain coloured PVC sheets for top rail, lock & bottom rail on either sides & as gap insert for top rail & bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beeding and jointed together with solvent cement as pere specification and drawing complete all as specified and directed. |
| 74 | M &L for Surface Preperation - Removal of all loose particles, dust,dirt,oil , grease,algae and fungus use wire mesh . Clean the surface and allow it to dry completely indetify and mark all visible cracks . Fill hairline cracks with smartC are crackseal . for wider cracks , use polymer modified mortar allow sufficient curing time as per product guidelines. Supply and application of smartcare PU infinia in three coats, with a minimum coverage of 1.8 kg / sqm, incorporating a fleece layer sandwiched between the first and second coats. the application is to be carried out over a surface primed with smartcare PU infinia primer , applied at a minimum coverage of 0.2 kg/sqm . The membrane exhibits the following properties:- elongation with fleece : 80% elongation without fleece : 400% crack bridging capability : upto 6.5 mm pull off strength : 1.5 mpa puncture resistance : greater than 200 N |
| 75 | Supply only liquid water proofing compound ISI marked. |
| 76 | Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site. |
| 77 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch/Busbar including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 78 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 79 | Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as specified and as directed note :- quoted price include transportataion to mes yard. |
| 80 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- |
| 81 | (a) One light point controlled by one, one way switch 5 Amps |
| 82 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 83 | (c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 84 | (d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 85 | Description all as per item No 80 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLSH insulated unsheathed 1100 volts grade for 5/15 amps point including necessary running of 2.5 sq mm copper FRLSH wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 86 | Description all as per item No 80 here in before but using 4 sq mm single core copper conductor cable of multistranded FRLSH insulated unsheathed 1100 volts grade for 5/15 amps point controlled with modular motor starter for air conditioner including necessary running of 4 sq mm copper FRLSH wire as earth continuity conductor along with wiring and connecting to the common earth dolly. for cooler complete all as specified and directed. |
| 87 | S & F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and directed |
| 88 | S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified and directed |
| 89 | S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 90 | S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed |
| 91 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified |
| 92 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 93 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 2.5 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 2.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 2.5 sqmm cable,one run of 1 sqmm cable and one run of PVC conduit will be measured as one unit |
| 94 | S & F for sheet metal enclosure MCB DB vertical TPN 8 way suitable for MCCB with 200 Amps rated bus bar 440 volts double door with locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to mtch with existing colour of wall complete all as specified and as directed. |
| 95 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to mtch with existing colour of wall complete all as specified and as directed. |
| 96 | S & F for MCB Single pole and neutral rated capacity 40 TO 63 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 97 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 98 | S & F for MCCB four pole rated capacity 125 Amps, 440 Volts breaking capacity 16 KA complete all as specified and as directed. |
| 99 | S & F LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 100 | Re-fixing of ceiling fan which had been taken down beforestarting of work. |
| 101 | M & L for earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 5 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-1 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and connected to earthing point complete all as specified and as directed. |
| 102 | M&L for laying, comnecting and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 1100 volts Earthed, grade cross sectional area 70 sq. mm. of 3.5 core all as specified and directed |
| 103 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying of pipe, cable, foundation of electric pole etc and getting out in soft/loose soil, complete all as specified & directed. |
| 104 | Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. |
| 105 | Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed. |
| 106 | Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 107 | Supply and laying for brick of common burnt clay, sub class 'B' old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other complete all as specified and directed. note :-all measurement in meter |
| 108 | Supply,laying galvanised steel tubing light grade complete with all fitting of size 50 mm dia for cable protection along with pole across road etc. Complete all as specified and directed |
| 109 | Supply and fixing LED street light fitting of 70 Watt 230 V AC outdoor type as building security light with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with bracket mounted on roof of bulding complete all as specified and directed. |
| 110 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers all as specified and directed Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. Please Enable Macros to View BoQ information |