| 1 | Demolition of brick work /stone masonry/PCC block masonry built in cement mortar of any description complete all as specified and as directed |
| 2 | Taking down cement plaster of any description hacking for key or raking out joint on old brick work/ stone /concrete surface etc complete all as specified and as directed |
| 3 | Demolition of Stone slab and tiles incl backing coat of any description or thickness in floors, aprons etc (Laid dry or laid dry and pointed) etc complete all as specified and as directed |
| 4 | Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed. |
| 5 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description & in any position not specifically provided for complete all as specified and as directed |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and as directed |
| 7 | Dismantling plain or corrugated steel sheeting any gauge thickness including nanital or similar pattern roof covering complete all as specified and as directed |
| 8 | Demolition and breaking up drain pipes up to 100 mm dia bofe (Salt glazed ware, AC or Reinforced concrete) set in cement mortar etc complete all as specified and as directed |
| 9 | Material and labour for Sand filling under floors or in foundations including watering and consolidation under bedding for interlocking tiles etc complete all as specified and as directed |
| 10 | Material and labour for plain cement concrete Type D-2 1:4:8 (with using 40 mm graded stone aggregates) as in foundations and mass concrete etc complete all as specified and as directed |
| 11 | Material and labour for Cement Concrete Type 1:2:4 B-0, (using 12.50 mm graded stone aggregate) as in surface channels and drains etc complete all as specified and directed. |
| 12 | Material and labour for providing cement concrete type 1:2:4 B 0 (12.50mm graded stone aggregate) in copings, leveling concrete, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed |
| 13 | Material and labour for Precast cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 etc complete all as specified and directed. |
| 14 | Material and labour for Reinforced cement concrete (nominal mix) type B-1 (1:2:4) with using 20 mm graded stone aggregates as Columns, pillars, piers, posts, ftg, etc struts etc complete all as specified and as directed |
| 15 | Material and labour for Providing 25mm thick precast cement concrete louvres Type B-0 , 1:2:4 (with using 12.5 mm graded stone aggregaes) set in CM 1:6 as and jallies, 25mm thick (measured solid), including all mouldings but excluding frame (Pre -cast frame shall be measured separately and paid for under item) etc complete all as specified and as directed |
| 16 | Supply only water proofing compound. |
| 17 | Material and labour for Brickwork (Old size Brick) with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 etc complete all as specified and as directed |
| 18 | Material and labour for brick work with sub class \\"B\\" bricks, straight or curved on plan exc to any radius in half brick thick walls built in built in CM 1:4 complete all as specifed and directed |
| 19 | Material and labour for 18 to 20mm thick granite Granite stone slab (of any type) work (table rubbed and polished) Granite (of any type) work for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab including grinding the edges half round etc complete all as specified and as directed |
| 20 | Material and labour for formwork with square / rectangular pillars, posts, struts, piers, columns and, ftg etc, stanchions with rough finished surface of concrete etc complete all as specified and as directed |
| 21 | Material and labour TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 22 | All as per item No 21 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and as directed |
| 23 | Material and labour for structural steel work with rolled mild steel sections as in main and cross beams, hip and jack rafters, trusses, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confoRMing to Fe-290 (Gde E-165) quality A complete all as specified and directed. |
| 24 | Supply and fix pre-painted hot dip aluminium zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick (total coated thickness), any patteren corresponding to IS 15965: 2012 of durability class 3, four (4) coat atmospheric classification category 3, coating class AZ 150 of an approved colour havingb yield strength of 550MPa as in roof covering/wall cladding, fixed with self tapping screws as complete all as specified and as directed. |
| 25 | Supply and fix pre-painted hot dip aluminium zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick (total coated thickness), any patteren corresponding to IS 15965: 2012 of durability class 3, four (4) coat atmospheric classification category 3, coating class AZ 150 of an approved colour havingb yield strength of 550MPa as in roof covering/wall cladding, fixed with self tapping screws as specified and as directedNote: To be executed for provison of ridges and hips, valley etc complete all as specifed and as directed |
| 26 | Material and labour for machine presssd Pre-Cast concrete interlocking coloured paving Block of glass fibre reinfoced glossy finished vibro compacted any shape and size confirming to IS-15658-2006 of 60 mm thick, M-35 grade to match with grey cement and pigment etc complete all as specified and as directed |
| 27 | Supply and fix exterior grade, coloured glossy finish rubber pressed, cement concrete designer chequered tiles of size 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles over etc complete all as specified and directed. |
| 28 | Material and labour for heavy duty parking tiles size 300mm X 300 mm X 10 mm thick white cement and pigments of approved maked jointed with cement slurry and pointed with white cement mixed with pigment to match with the tiles complete all as specified and directed. |
| 29 | Material and labour for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and Mirror polishing incl cutting edges etc etc complete all as specified and as directed complete all as specified and as directed |
| 30 | Material and labour for machine cut Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with including 10mm thick rendering in CM 1:4 etc set and jointed in neat cement slurry complete all as specified and directed. |
| 31 | Material and labour for Screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes etc complete all as specified and as directed |
| 32 | Material and labour for 100mm thick cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate ) as in flooring, hardstanding complete all as specified and directed. |
| 33 | Material and labour for 100 mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation, floor etc complete all as specified and directed. |
| 34 | Material and labour for 25 mm thick PCC (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in floor finished rough to receive tiles complete all as specified and as directed. |
| 35 | Material and labour for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surface finsihed even and smooth (without using extra cement) etc complete all as specified and as directed |
| 36 | Material and labour for rendering for ceiling 5 mm thick in CM 1:3 on fair faces of brick work or concrete surface finished even and smooth without using extra cement etc complete all as specified and as directed |
| 37 | Material and labour for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surface finsihed even and smooth (without using extra cement) mixed with water proofing compound as per manufacture instruction etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately |
| 38 | Material and Labour for preparing new plastered surface of wall and applying two coat of cement base paint ove a coat of cement primer etc complete all as specified and as directed |
| 39 | Material and labour for preparation new plastered surface of wall and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance (Apex Ultima), dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. etc complete all as specified and as directed |
| 40 | Material and labour for preparation of newly plastered surface of ceiling and applying three coats of white wash including preparation complete all as specified and as directed. |
| 41 | Complete removal exising treatment by means of wire brushing, sand paper, manually or mechanically up to visible of plastered surface incl rubbing and washing etc complete all as specified and as directed |
| 42 | Material and labour for preparation of Old plastered surface of wall and applying two coat of cement base paint etc complete all as specified and as directed |
| 43 | Material and labour for preparation old plastered surface of wall and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance (Apex Ultima), dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. etc complete all as specified and as directed |
| 44 | Material and labour for Preparation New of previously un treated steel and iron surface of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed |
| 45 | Supply and fix 110 mm PVC, SWR pipes, single socketed in any length with rubber ring joint fixed to walls/floor etc etc complete all as specified and directed |
| 46 | Supply and fix 75 mm PVC, SWR pipes, single socketed in any length with rubber ring joint fixed to walls /Floor etc complete all as specified and directed |
| 47 | Supply and fix PVC bends (any radius) of 110mm dia with access door etc complete all as specified and as directed |
| 48 | Supply and fix PVC bends (any radius) of 75mm dia with access door etc complete all as specified and as directed |
| 49 | Material and labour for spraying antiweed / non toxic solution / chemicals containing Glyphosate as per manufacture instructions and removing the weed including the roots after ensuring complete de-germification of palnt/weed and cutting down the plant/trees off from roof/top sides of external walls of bldgs, in chajjas, wall junctions, junctions of GI/CI/AC/PVC pipes and taking out roots entered in wall/slabs, including making good the surface using PCC 1:2:4 type B1 or cement mortar (1:2) or brick work in CM(1:4) plastered with CM(1:4) to match with existing surface and repairing the pipes and joints which was affected by cutting down/taking out process all as specified and as directed for plants / trees located in the buildings at any height of bldgs, complete all as specified and directed. |
| 50 | Maintenance/cleaning of masonry of concrete drains ( cross sectional area not exceeding 1.20 sqm) by desilting of all deposited soil/silts and other materials including removing all vegetation from side and bottom of drains to a distance exceeding 250m and not exceeding 500m and depositing in layers not exceeding 25cm thick complete to the original shape of drains and free flow of water and complete all as specified and directed. Please Enable Macros to View BoQ information |