| 1 | Dismantling of asbestos, cement (corrugated, semicorrugated, etc.) sheets in roof coverings , complelet all as specified and directed. |
| 2 | Dismantling timber scantlings (framed work) 40 Sqcm and over in section, in any position complete all as specified and as directed. |
| 3 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) of any type and any thickness including cover fillets/GI grid framework complete all as specified and directed. |
| 4 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 5 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. |
| 6 | Structural steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality B complete all as specified. |
| 7 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 8 | Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter, ridge & similar works fixed with self tapping screws complete all as specified. |
| 9 | Preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of anti corrosive synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed. |
| 10 | GI snap grid frame work (Grid size 600x600mm) with powder coated GI angle of size 25x25x3mm fixed along wall perimeter, main runner 'T' of size 25x40x3mm , secondary runner 'T' of size 25x30x3mm suspended with 3mm GI wire @ 1200mm c/c of ceiling by fasteners of adjustable guide hanger including clips/MS fitments to hold the panels including 4mm thick prelaminated designer ceiling board to be inserted in this GI snap grid complete all as specified. |
| 11 | Anodised aluminium snap grid frame work for false ceiling and providing and fixing gypsum board 12mm thick in ceiling fixed with screw as per manufacturers instruction fixed in repairs complete all as specified and directed. |
| 12 | 3 mm thick wall putty on platered wall surface of any description complete all as specified and directed. |
| 13 | Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper complete all as specified and as directed. |
| 14 | Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified and as directed. |
| 15 | Ditto all as per slr 14 here in before ,but except bricks |
| 16 | Rendering 15mm thick in cement mortar (1:4) on fair faces of the brick work or cement concrete surfaces, finishing the surface even and smooth without using extra cement, complete all as specified |
| 17 | Preparation of newly plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed. |
| 18 | Preparatiion of old existing painted surfaces incl washing, rubbing down and stopping of old plaster surfaces and applying one of cement base paint white or tined on wall surfaces complete all as specified and directed |
| 19 | Preparatiion of old existing painted surfaces incll washing, rubbing down and stopping of distemper surfaces and applying one coat of oil bound distemper on wall surfaces complete all as specified and directed |
| 20 | Demolition / taking down of existing old tarfelt , water proofing membrane, water proofing plaster of any description any type over RCC roof including any roof tiles, cement mortar screed, concrete screed of any thickness, for fixing of angle iron for water tank postion, incuding making good the surface by concrete to smooth surface complete all as specified and as directed. |
| 21 | Rendering 10 mm thick in cement and sand mortar 1:3 on fair faces even and smooth finish mixed with water compound as per manufactures's instructions complete all as specified and directed.Note : WPC Shall be measured and paid seperately under replacement iteam of schedule. |
| 22 | Supply only liquid water proofing admixture conforming to IS 2645-1975 of approved make complete all as specified and directed.(Dosage- @ 200ml per 50Kgs of Bags of cement) |
| 23 | Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course : Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course : APP (Atactic Polypropylene) modified polymeric membrane, 5 layered, 3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints and changes in direction should be covered with cement mortar 1:3 mixed with SBR latex @200ml/bag of cement and curved before laying of membarance.(c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrance and dusted with dry sand @ 0.50 to 1 Kg/sqm. Note:-(i) The water proofing treatment shall be got carried out from the authorised personal of the Company all as specified and directed. |
| 24 | Disconnecting existing tanks of capacity 250 to 500 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including necessary replacement of tanks joints of any size & description, complete all as specified and directed. |
| 25 | Disconnecting existing tanks of capacity 500 to 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including necessary replacement of tanks joints of any size & description, complete all as specified and directed. |
| 26 | Dismantling water tanks of cap exc 250 but n.exc 500 ltr all as specified and directed. |
| 27 | Dismantling water tanks of cap exc 500 but n.exc 1000 ltr all as specified and directed. |
| 28 | Rotational moulded polyethylene water storage tanks triple layer (Cylindrical vertical with closed top) hoisted and fixed in position all as spd in SSR Pt-I, of capacity 500 Ltrs with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and as directed. |
| 29 | Rotational moulded polyethylene water storage tanks triple layer (Cylindrical vertical with closed top) hoisted and fixed in position all as spd in SSR Pt-I, of capacity 1000 Ltrs with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and as directed. |
| 30 | Ball valves, high pressure 15 MM of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed (minimum weight 142 gms) complete all as specified and as directed. |
| 31 | S & F in repairs 20mm Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed (minimum weight 210 gms) complete all as specified and as directed. |
| 32 | Nipple 15 mm bore suitable for HDPE water tank.(Minimum weight 38gms) in repairs complete all as specified and as directed. |
| 33 | Nipple 20 mm bore suitable for HDPE water tank.(Minimum weight 38gms) in repairs complete all as specified and as directed. |
| 34 | Taking up or down steel tubing and connections, including cleaning for refixing or removal to store and supply and fixing G I tubing 15 mm bore medium grade, galvanised, with all fitting, laid in trenches or in floors/walls complete as specified and as directed. |
| 35 | Taking up or down stee incl tubing and connections, including cleaning for refixing or removal to store and supply and fixing G I tubing 20 mm bore medium grade, galvanised, with all fitting, laid in trenches or in floors/walls complete as specified and as directed. |
| 36 | S & F in repairs PVC (SWR) pipes, single socketed, in any length with rubber rings 75 mm dia as in spouts and rain water pipes etc complete all as specified and as directed. |
| 37 | S & F in repairs PVC (SWR) pipes, single socketed, in any length with rubber rings 110 mm dia as in spouts and rain water pipes etc complete all as specified and as directed. Please Enable Macros to View BoQ information |