| 1 | S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall & Chajja, fixed with self tapping screws including dismantling CGI or PGI sheet of any gauge and thickness or any pattern roof covering complete all as specified and directed by Engr-in Charge. |
| 2 | S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling CGI or PGI sheet of any gauge and thickness or any pattern roof covering ccomplete all as specified and directed by Engr-in Charge. |
| 3 | S&F for 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with L- type or J- type or cranked hook bolts and washers or fixed with self tapping screws as specified, in roofs, walls etc. with grade of zinc coating 275 including dismantling CGI or PGI sheet of any gauge and thickness or any pattern roof covering complete all as specified and directed by Engr-in Charge. |
| 4 | S&F for 0.63mm thick Galvanised Plain mild steel sheeting of thickness 0.63mm in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 with L or J type or cranked hooks and washers bitumen washer or fixed with self tapping screws as specified, including dismantling CGI or PGI sheet of any gauge and thickness or any pattern roof covering complete all as specified and directed by Engr-in Charge. |
| 5 | Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre.including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold asteners 12.5mm dia. 40mm long complete all as specified & M & L 8 mm thick in calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid in Exposed metal frame ceiling all as specified and as directed. & including dismantling of wall and ceiling boards any thickness of any description including cover fillets complete all as specified and directed by Engr-in Charge. |
| 6 | Demolation of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for water tank staging complete all as specified and directed by Engr-in- Charge. |
| 7 | S&F structural steel work as in roof trusses (framed), trussed, purlins, rafter, crane gantries, rails, water tank staging, frame work chajja & fastenings & heavy brackets framing including distance pieces, cleats etc. confirming to Fe 410-W (E-250 grade quality A) complete all as specified and directed by Engr-in Charge. |
| 8 | M&L for preparation of new steel and iron surfaces and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in Charge. |
| 9 | S&F for rotational moulded High Density Poly-Ethylene water storage tanks of capacity 500 litre and conforming to IS, hoisted and fixed in any position includiing dismantling of water tanks capacity exc 250 ltrs but n.exc 500 ltrs and removing from the site or to store complete all as specified and directed by Engr-in Charge. |
| 10 | S&F rotational moulded High Density Poly-Ethylene water storage tanks of capacity 1000 litre and conforming to IS, hoisted and fixed in any position includiing dismantling of water tanks capacity exc 500 ltrs but n.exc 1000 ltrs and removing from the site or to store complete all as specified and directed by Engr-in Charge. |
| 11 | S&F for GI tubes medium grade 20mm dia, with all fittings and fixed complete to walls and ceiling or laid in floors, including taking up or down steel tubing of 20mm bore and connections complete all as specified and directed by Engr-in Charge. |
| 12 | S&F in repair ball valves suitable for 20 mm bore iron pipe high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball, screwed for iron pipe and fixed. (minimum weight 210 gms) complete all as specified and directed by Engr-in Charge. |
| 13 | M&L for preparation of old painted steel and iron surfaces of any description and in any position over 10 cm width or girth as in roof, not other wise specially described and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in Charge. |
| 14 | M&L for removing old paint by paint removers and cleaning with scrapers, any number of coats, any width or girth as in roof, not other wise specially described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in Charge. Please Enable Macros to View BoQ information |