| 1 | Electrical work : |
| 2 | Wiring for light & fan point with 2 X 1.5 sq. mm. PVC insulated copper conductor cable (FR) in PVC casing and capping complete with PVC surface modular switch board with cover plate and 10A. modular switch including connection etc. as required a) Short Point :- |
| 3 | b) Medium point:- |
| 4 | c) Long point:- |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socketincluding connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socketincluding connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required |
| 7 | Wiring for circuit/sub-main wiring with theFollowingsizesPVCinsulatedcopperconductorcable (FR) in PVC casing capping including connection etc. as required. 2X1.5sq.mm. |
| 8 | 2X2.5sq.mm. |
| 9 | c) 2 x 4.00 sq mm |
| 10 | d) 4 x 16 sq mm |
| 11 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- 1 X 1.5 sq mm |
| 12 | b)1 X 2.5 |
| 13 | Providing earthingsystem with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mmx 6mm including accessories with masonry enclosure of CI cover plate size 12\\"x 12\\" having locking arrangement including CC works etc as required:- |
| 14 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod ,canopies ,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 15 | Supplying and fixing of 12 watt LED downlight with integral driver and high quality polycarbonate diffuser surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 16 | Supplying and fixing of 60 watt LED street light fixture with integral driver and secondary lens (IP 66) outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of100 lm/watt):- |
| 17 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-20 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 18 | 12 watt LED retrofit lamp with polycarbonate body and aluminium heat sink. |
| 19 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:-a)200 amps 415 volts four strip Copper busbar chamber 4 ways of size (455mmx330mmx120mm):- |
| 20 | b)100 amps 415 volts four strip Copper busbar chamber 4 ways of size (455mmx330mmx120mm):- |
| 21 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:- a)200 amps 415 volts TPN main switch (rewireable):- |
| 22 | b)100 amps 415 volts TPN main switch (rewireable):- |
| 23 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. a)4 way SPN MCB DB (single door):- |
| 24 | b)4 way horizontal TPN MCB DB (Double door):- |
| 25 | c)6 way horizontal TPN MCB DB (Single door):- |
| 26 | Supplying and laying of the 3 core 4 Sq mmsizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required. |
| 27 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required:- |
| 28 | Supplying and installation of fuse unit kitkat/HRC/HBC of the100 amps kitkat porcelain fuse unit with base(rewireable) ratings in existing main switch/panel board including necessary connection etc as required:- |
| 29 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of 6 to 32 amps SP MCBratings in the existing MCB DB including connection asrequired:- |
| 30 | Supplying & fixing of the following electrical accessories etc. i/c necessary connection as required as per design / direction of the Engg-In-Ch. a) 25 mm dia heavy duty PVC gland (DAR) |
| 31 | b) 25 mm dia heavy duty PVC flexible pipe (DAR) |
| 32 | c) 10 sq mm copper terminal ends. |
| 33 | d) 16 sq mm copper terminal ends. |
| 34 | e) 06 sq mm copper terminal ends. |
| 35 | f) 4 step fan regulator (1M):- |
| 36 | Supplying and fixing of 40 mm dia G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall / RCC base with necessary M.S. clamp, nut bolts etc as required |
| 37 | Painting of 40 mm dia G.I. pipes and fitting with synthetic enamel white paint over a ready mixed priming coat, both of approved quality for new work. (TSR-2017) Please Enable Macros to View BoQ information |