| 1 | Boundary Wall Work |
| 2 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 12.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 4 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)SOR (5.2.2) |
| 5 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. 16.18.1 With G.I. barbed wire |
| 6 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 7 | Finishing walls with Putty approved brand and manufacture and of required shade on undacorated wall surface to give even shade over including curing and cost of all material, labour, T&P etc. required for proper completion of work. |
| 8 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 9 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 10 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)SOR (5.1.2) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 12 | Steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. thermo-mechanically treated bars of grade fe-500D or more. |
| 13 | SHADE ROOM AND OTHER PAINTING RELATED WORKS |
| 14 | Finishing walls with Putty approved brand and manufacture and of required shade on undacorated wall surface to give even shade over including curing and cost of all material, labour, T&P etc. required for proper completion of work. |
| 15 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 17 | 38 mm thick wood block flooring of first class teak wood laid over 25 mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete. |
| 18 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (13.48.2) |
| 19 | Providing and fixing 3 seater garden cast iron bench |
| 20 | Gypsum false ceiling including framework |
| 21 | Providing and fixing panelling or paneling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebated to be measured). Panelling for panelled and glazed shutters 25mm to 40mm thick: Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 12 mm thick conforming to IS:14587 |
| 22 | Backlit Fabric display signange 30 feetwalls ht:10' (4'x10') |
| 23 | Migratory bird HD mural wall installation |
| 24 | Central interactive table fabrication (10'x6') |
| 25 | Map of Sanjay Van (MS CNC) |
| 26 | Track light system (15W focus lights) Wipro make |
| 27 | LED strip cove lighting |
| 28 | Entrance Gate ACP work, Providing and fixing 4 mm ACP sheet on alluminium structure frame with screw/bolt of any color as per design |
| 29 | Entrance name \\"Sanjay van chetna kendra\\" and address as/design in acrylic with light |
| 30 | P/A ART WORK and painting by skilled painter with approved quality paint including all work |
| 31 | MS gazebo with 4\\"x4\\" MS Vertical pipe with gazebo roof frame with 1.5\\"x1.5\\" MS hollow pipe finished with MS Sheet,hexagonal shape with 10' Feet Dia. |
| 32 | \\" I love Sanjay van\\" Acrylic logo with backlit with MS frame 1M high |
| 33 | Dustbin FRP/Plastic |
| 34 | SWAN SCULPTURE |
| 35 | ELIPHANT SCULPTURE |
| 36 | TIGER SCULPTURE |
| 37 | PATH WORK FOR SANJAY VAN |
| 38 | Dismantling cement concrete or brick or granolithic floors including stacking of dismantled materials as directed by Engineer-In-Charge within a distance of 60 meters (200 feet). |
| 39 | E/W in Cutting or in embankment in ordinary soil excavation to be done in form of regular pits not exceeding 1/2 m in depth and work embankment to be in 20cm layers including ramming and dressing the surface to required level and slopes and also including 1.5 m lift and 30m lead. |
| 40 | Providing and laying in cement concrete in 8:4:1 ( stone ballast 8 (40 mm nominal size) : 4 approved coarse sand : 1 cement and curing complete, including cost of formwork in foundation and floors. (SOR 2023-24 4.1.8) |
| 41 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 42 | Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement: 3 coarse sand), including the cost of required centering, shuttering complete.1:12:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) UPPWD SOR 23-24 4.6.1 |
| 43 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 44 | With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 45 | Providing and laying 80mm thick rubber mould tiles of precast comprest CC paving minimum 30MPA compressive strength (ISI Marked) with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 46 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.uppwd sor23-24 (2.25a+2.25c) |
| 47 | Add extra 5 km cartage |
| 48 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres .DSR(Analysis) |
| 49 | ELECTRICAL WORKS |
| 50 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 51 | Group C |
| 52 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 53 | 2X1.5 sqmm + 1x1.5 sqmm earth wire |
| 54 | 2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 55 | 2X4.0 sqmm + 1x 4.0 sqmm earth wire |
| 56 | Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: |
| 57 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 58 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 59 | 1 or 2 module(75mm X 75 mm ) |
| 60 | Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required. |
| 61 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 62 | Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. |
| 63 | upto 450 mm sweep. |
| 64 | Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. |
| 65 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required. |
| 66 | Supplying and fixing following way, Horizontal type three pole and neutral MCB distribution board, 415 volts on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). |
| 67 | 6 way (4 + 18), Double door |
| 68 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 69 | Single Pole |
| 70 | Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required. |
| 71 | Supply and fixing following rateing four pole, 415 V, isolator in the existing existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 72 | Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. |
| 73 | 16 sqmm 4 core |
| 74 | Supply & fixing of 7/9 W LED BULB complete in all respect. |
| 75 | Supply of AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.-Make: Havells-STANDARD -Refresh Air-SPS |
| 76 | 300mm sweep. Please Enable Macros to View BoQ information |