| 1 | Civil Work |
| 2 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 3 | Glazed vitrified floor tiles polished finish of size |
| 4 | Size of Tile 600 x 600 mm |
| 5 | Size of Tile 600 x 1200 mm |
| 6 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 7 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 8 | 12 mm cement plaster of mix : |
| 9 | 1:4 (1 cement: 4 coarse sand) |
| 10 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 11 | 1:4 (1 cement: 4 fine sand) |
| 12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 13 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 14 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : |
| 15 | New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 16 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 17 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 18 | One or more coats on old work |
| 19 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 20 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 21 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 22 | Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) |
| 23 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 24 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in- harge. |
| 25 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 26 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge |
| 27 | In cement mortar |
| 28 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 29 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 30 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 31 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 32 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 33 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 34 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 35 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with 959 SUB HEAD : 12- ROOFING galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 36 | GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece |
| 37 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 38 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 39 | Kitchen sink without drain board |
| 40 | 610x510 mm bowl depth 200 mm |
| 41 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 42 | 250x16 mm |
| 43 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 44 | 150x10 mm |
| 45 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 46 | 125 mm |
| 47 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 48 | For fixed portion |
| 49 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 50 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 51 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 52 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge. |
| 53 | Pre-laminated particle board with decorative lamination on both sides |
| 54 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 55 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 56 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors |
| 57 | 100 mm inlet and 75 mm outlet |
| 58 | Sand Cast Iron S&S as per IS- 3989 |
| 59 | Providing and Fixing Frost filming on the glass doors and partition as per the given design |
| 60 | Providing and Fixing Megnetic Catcher on backside of glass doors |
| 61 | Providing and fixing of wood panelling with wooden ply 12 mm thick and 1 mm thick laminate over it in specified design complete in all respect |
| 62 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 63 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 64 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 65 | 1.0 mm thick |
| 66 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
| 67 | 2nd class teak wood |
| 68 | 50x12 mm |
| 69 | Providing and fixing bright/Matt finished stainless steel fancy handles of approved quality and make complete in all respect. |
| 70 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 71 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 72 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarsesand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as perdirection of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 73 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 74 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 75 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 76 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 77 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe including painting with anticorrosive bitumastic paint, cutting chases and making good the wall: |
| 78 | 15 mm dia nominal bore |
| 79 | 20 mm dia nominal bore |
| 80 | Providing and fixing C.P long body Bib Cock with wall flange of Make Jaquar Model or equivalaent model of approved make. |
| 81 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 82 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 83 | Granite stone slab colour black, Cherry/Ruby red |
| 84 | Area of slab over 0.50 sqm |
| 85 | Total Civil Work |
| 86 | ELECTRICAL WORK |
| 87 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 88 | Group C |
| 89 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 90 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 91 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 92 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 93 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 94 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 95 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 96 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 97 | Group C |
| 98 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 99 | 3 x 1.5 sq. mm |
| 100 | 3 x 2.5 sq. mm |
| 101 | 4 x 2.5 sq. mm |
| 102 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 103 | 20 mm |
| 104 | 25 mm |
| 105 | 32 mm |
| 106 | 40 mm |
| 107 | 50 mm |
| 108 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 109 | 100 mm X 100 mm X 60 mm deep |
| 110 | 200 mm X 150 mm X 60 mm deep |
| 111 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 112 | 5/6 A switch |
| 113 | 15/16 A switch |
| 114 | 3 pin 5/6 A socket outlet |
| 115 | 6 pin 15/16 A socket outlet |
| 116 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 117 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 118 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 119 | 1 or 2 Module |
| 120 | 6 Module |
| 121 | 12 Module |
| 122 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 123 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 124 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 125 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 126 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 127 | Group C |
| 128 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 129 | 100 A/63 Amp, 16 KA,TPMCCB |
| 130 | 125 A,36KA,FPMCCB |
| 131 | 200 A,36KA,FPMCCB |
| 132 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 133 | 12 way , Double door |
| 134 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MOB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 135 | 6 way (4 + 18), Double door |
| 136 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required. |
| 137 | Single pole |
| 138 | Triple pole and neutral |
| 139 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc.as required. |
| 140 | For 10 way, Double door SPN MCBDB |
| 141 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. |
| 142 | For 6 way, Double door TPN MCBDB |
| 143 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. |
| 144 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 145 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 146 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 147 | Providing and fixing 25 mm X 5 mm GI. strip on surface or in recess for connections etc. as required. |
| 148 | Providing and fixing 6 SWG dia GI. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ subnnain wiring/ cable as required. |
| 149 | Supply ,installation, testing and commissioning of recessed type LED panel 2'x 2',having CRCA housing duly painted with diffuser, minimum 4200 lumens (120 lumens/watt),5700K/6500K and 50000 burning hours of make Philips RC 380-B LED 42S-6500-G6/ Wipro CRCO10R036HE57G3 / Havells PLANO 2X2 PLR 36W LED865TAPS/Bajaj-BZRSQL43L-LEDGXPROWH.The job inculdes the cost of testing, commisisoning and making connection with 3*1.5 sq mm copper wire upto 1.5mt from adjacent light point, other petty material and labour etc as required to complete the same to the entire satisfaction of Engineer in Charge. |
| 150 | Supply ,installation, testing and commissioning of recessed type down lighter 15 watt of 4000K/5700K/6500K (as approved by engineer in charge) having synthetic/powder coated pressure diecast alulminium body having high efficiency diffuser with more than 85% transmittance with rated life of L-70 @50,000 hours having system lumens more than 1500 lumens and efficacy better than 110 lumens/watt with CRI >80 and drivers efficiency >85% , THD less than 10% with inbuilt surge protection upto 2.5 KV. The job includes fixing down lighter and connection with 3x1.5sqmm copper wire upto 1.5mtr length from adjacent light point with all petty material and labour required to complete the job in all respect. Makes Havells-INTEGRAHE-DLR 15W LED/ Wipro-LD06-171XXX-HE/ Panasonic-PDLP35-15W/ Philips-Green perform sleek G2 DN296B-LED15S-PSE-WHS1. |
| 151 | Supply ,installation, testing and commissioning of recessed type down lighter 12 watt of 4000K/5700K/6500K (as approved by engineer in charge) having synthetic/powder coated pressure diecast alulminium body having high efficiency diffuser with more than 85% transmittance with rated life of L-70 @50,000 hours having system lumens more than 1200 lumensand efficacy better than 110 lumens/watt with CRI >80 and drivers efficiency >85% , THD less than 10% with inbuilt surge protection upto 2.5 KV. The job includes fixing down lighter and connection with 3x1.5sqmm copper wire upto 1.5mtr length from adjacent light point with all petty material and labour required to complete the job in all respect. Makes Havells-INTEGRAHE-DLR 12W LED/ Wipro-LD06-151XXX-HE/ Panasonic-PDLM35-12W/ Philips-Green perform sleek G2 DN296B-LED12S-PSE-WHS1. |
| 152 | Providing and Fixing of PVC Rigid drain Pipe surface/recess with necessary repair to the original condition, complete in all respects from indoor unit to Disposal Points as directed by the E.I.C. Size ¾” including specials- Make- Diplast or Equalivent. |
| 153 | Fixing of existing floor mounted panel by grouting angle iron legs in floor with cement concrete and necessary connections. |
| 154 | Providing and fixing of terminal box made of 1.6mm thick sheet steel enclosure duly painted with three phase and neutral terminals of 4 nos alumnium strips,suitable for 125 amp capacity completed in all respect with all petty material and labour required. |
| 155 | Dismantling and reinstalation of existing aluminium/ copper conductor cables on surface/duly recessed in wall or floor and making good the same with necessary repair as required with necessary connections including all petty material and labour required to complete size upto 50mmsqx 3.5 core cable |
| 156 | Supply, erection testing and commissioning of UTP cat 6 information outlest (RED for Data- User End) complete in all respect upto the entire satisfaction of Enigneer In-charge of the work make- Molex/R&M/Semon/D-Link |
| 157 | Supply, erection, testing and commissioning UTP face plate (Single/dual) along with modular box75mmx75mm complete in all respect upto he entire satisfaction of Enigneer In-charge of the work make- Molex/R&M/Semon/D-Link |
| 158 | Suppply and erection of AC ceiling fan 1400mm sweep with copper winding but without regulator complete with MS blades, plastic canopies 2 nos double ball bearing, MS hanging rods (As per site requirement), condenser, reels, clamps erc. The body of fan and blades should be white in colour. The job includes the cost of making necessary connections from the adjacent light point with 1.5mm2 single core copper consuctor cable and 3mm thick white BL sheet cover for fan box of suitable size. The sample of fans shall be got approved from the SDE in charge of work before installation at site. The job also includes the cost of carriage, erection, testing, commissioning of fan, all labour and petty material required to complete the job to the entire satisfaction of the Engineer in charge.Makes Havells-Velocity/Orient-New Breeze/Crompton-High Speed/ Usha-Strikers/Bajaj- Sabse-tej only |
| 159 | Supply and errection of 1x20 watt 4' long LED box / Patti type fittings with decortative end caps of make Crompton CAT no. DMLNILT8-16+LT8-20-865-2 or equivalent models of make Philips/Surya make only .The LED tube rod 20 watt polycarbonate with inbuilt driver, extruded aluminium heat sink, 50000 burning hours at 70% lumens maintenance of makes Philips/Havells/Wipro/Crompton/Bajaj. The job includes carriage, erection, making connections with 3x1.5 sq.mm copper wire from adjacent light point, testing and commissioning of the fittings etc. as requried to complete the same to the entire satisfaction of engineer in charge. |
| 160 | Supply and erection of fan rod 24\\" length made of seemless MS pipe dia duly powder coated complete in all respect. Make National |
| 161 | Supply and fixing of 63 amp rating, TP MCB 415V, 10KA\\"C\\" curve miniature circuit breaker suitable for inductive load of following poles in the existing DB complete with connections, testing and commissioning as required.Makes Havels/ABB/L&T/Schnieder |
| 162 | Supply and fixing of 63 amp rating, TPN MCB 415V, 10KA\\"C\\" curve miniature circuit breaker suitable for inductive load of following poles in the existing DB complete with connections, testing and commissioning as required.Makes Havels/ABB/L&T/Schnieder |
| 163 | Supply and fixing of 63 amp rating, DPMCB 415V, 10KA\\"C\\" curve miniature circuit breaker suitable for inductive load of following poles in the existing DB complete with connections, testing and commissioning as required. |
| 164 | Supply and erection of exhaust fan metalic body, Size 380mm'' sweep 900 RPM complete in all respect with necessary connections. The job includes Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Makes:- Havells- turbo force SP/crompton- EXHD 380-6-1/Bajaj-Supreme Plus. |
| 165 | Supply and erection of National make louver shutter with aluminium wings for exhaust fan of size 300mm on exisiting hole complete with petty material and labour requierd to complete the job. |
| 166 | Providing and fixing of 19mm thick ply wood frame (ISI marked) of size 24\\"X27\\" with cutting hole for Exhaust fan 380mm, duly painting on both side one coat of primer and two coats of approved paints to be fixed on existing wooden ventilator for fixing fresh air fan by cutting existing 3 no MS bars with all petty material and labour required to complete the job |
| 167 | Supplying and fixing of Surface/recess mounting 8 way TP &N vertical load line distribution board double door steel, dust protected, duly powder coating inclusive of tinned copper bus bars,200 amp neutral link earth bar with provision of in commer MCCB (W/o MCCB) and outgoing MCB's (Without MCB's) complete in with all petty material and labour required.Makes Havels/ABB/L&T/Schnieder |
| 168 | Supply and fixing of TPN Sheet Steel enclosure on surface /recess along with 63 Amp 415V, 10KA\\"C\\" curve TPN MCB complete with connections, testing and commissioning as required. Makes Havells/ABB/L&T/Schnieder |
| 169 | Supply and installation of sheet steel enclosure for TP/FPMCCB up to 100amp with neutral link on existing board/recessed in wall with all petty material and labour required to complete the job in all respect. Make Havells/ABB/L&T/Schnieder Please Enable Macros to View BoQ information |