| 1 | Supply and delivery of Ceilling fan 48... Sweep Crompton Greaves make |
| 2 | Fixing only ceiling fan complete with blades, canopy, FORk, rubber bush etc. incl. S&F connecting wire FOR down rod upto 30 cm incl. painting the rod with(approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 3 | Supply and delivery of 230V,50Hz Heavy duty Metal 12\\"exhuast fan. |
| 4 | Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) FOR 30 cm (12\\") Exhaust fan |
| 5 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection FOR exhaust of following diameter:30 cm (12\\") dia |
| 6 | Supply and delivery of Wall fan 16... Sweep metal blade Crompton Greaves make |
| 7 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length |
| 8 | SUPPLY & DELIVERY OF 18/20 WATT LED TUBE LIGHT RETROFIT TYPE 4FT |
| 9 | Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc. |
| 10 | Fan :Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with rein FORcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. |
| 11 | Concealed Wiring With PVC Insulated and Sheathed Wires in Polythene Pipes - Laying & Fixing Polythene Pipe, MS Boxes, Switches etc. Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction )(c)25mm dia 3mm thick Polythene Pipe |
| 12 | Concealed Wiring With PVC Insulated and Sheathed Wires in Polythene Pipes - Laying & Fixing PolythenePipe, MS Boxes, Switches etc.Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works 25 mm dia 3 mm thick polythene pipe with 1x14 SWG GI earth continuity wire |
| 13 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand(approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm) |
| 14 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand(approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 36/0.3 (2.5 sqmm) |
| 15 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand(approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 56/0.3 (4 sqmm) |
| 16 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 3. Cable end box (16SWG) FOR TPN SFU enclosure 200A |
| 17 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection L&T FP 160A |
| 18 | Supplying and fixing MCCB SS enclosure with IP- 20/30 protection, pwder coated provision FOR housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish / on flat iron frame incl. painting, connection & provision FOR earthing attachment Standard (SKB8) |
| 19 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection L&T 63A DP |
| 20 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection L&T 6-32A DP |
| 21 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection L&T 6-32A SP |
| 22 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision FOR earthing attachment .Legrand 2+8 way Enclosure (607711) |
| 23 | Fittings :Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board |
| 24 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 60.16SWG MS Box (250X200X65mm) 10\\"x8\\"x2.5\\" |
| 25 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 97. 2 row 12 module Cover plate |
| 26 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 77. 5 A, piano key type Switch |
| 27 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 81. 20A Piano key type Switch |
| 28 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 82. 5 A, 3 pin Piano flush type Socket |
| 29 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 83. 15A flushed type 3 pin Plug Socket |
| 30 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 84.....Step Type Electronics Fan regulator |
| 31 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 86. 1 module GI box |
| 32 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 92. 1 module Cover plate |
| 33 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 168. Rag bolt FOR stay |
| 34 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 112. 20/25A starter |
| 35 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 113. 20/25A plug top |
| 36 | SUPPLY AND INSTALLATIONOF SPLIT TYPE ROOM AIR CONDITIONING MACHINE OF FOLLOWING TONNAGE CAPACITY 3 STAR RATING FIFLED WITH ROTARY CROMPRESSER AND COOLING CAPACITY MIN. 6000 K CAL/HR., MINIMUM DISCHARGE AIR FLOW 800CUM MTR, 800EER ( W/W) 2.7-2.89. (RATES ARE INCLUSIVE OF EXTRA REFRIGERANT PIPE DRAIN PIPE CONNECTING CABLE) UP TO THE SATISFACTION OF THE EIC.2.0 TON (MAKE : VOLTAS) 3 STAR NON-INVERTER TYPE AS PER IRRIGATION AND WATERWAYS SCHEDULE, 2022 |
| 37 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF SUCTION/ DISCHARGE COPPER PIPE LINE IN SPLIT AIR CONDITIONING UNIT 1.0/1.5 TR/2 TR/3 TR CAPACITY INCLUDING BRAZING, NITRILE RUBBER INSULATION 6/9MM THICK CLASS 'O', ETC COMPLETE AS REQUIRED. COPPER TUBE 1/2? AS PER IRRIGATION AND WATERWAYS SCHEDULE, 2022 |
| 38 | SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation by GI pipe ... (FOR Sub(station Neutral/Equipment earthing)Earthing with 80 mm dia GI pipe (TATA(Medium)x 3.0 Mts. long and 1 x 19/8 stranded GI (HOT Dip) wire (4 Mts. long), 25 mm dia x 150 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (h)ot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts |
| 39 | Supply and Fixing of 2 mm Polyvinyl glow sign board made of 22 SWG GI sheet box with 1...X1... aluminum channel for fixing the vinyl board after necessary cutting the letter as required & s\f LED tube light fittings along with all accessories |
| 40 | SUPPLY AND FIXING OF HAVELLS POST TOP LUMINARIES MODEL NO : CORAL PT35WLED (35WAFL) OVER THE PREINSTALLED GI PIPE OVER THE GATE STRUCTURE OR SIMILAR STRUCTURE INCL. CONNECTION BY 1.5 SQ MM CU WIRE FROM LOOP BOX TO THE LIGHT |
| 41 | SUPPLY & DELIVERY OF LED OUTDOOR STREET LIGHT FITTINGS OF 100WATT AS PER LAST STORE PURCHASE RATE OF STORE AND SUPPLY DEPARTMENT, KMC |
| 42 | (H) Street lights :2. Distribution wiring FOR steel light on pole FOR outdoor fluorescent/SV/MV light fitting with 2x1/1.40 PVC insulated and sheathed wire (single core) in 15 mm dia GI Pipe (ISI Medium), without control switch, incl. fitting and fixing the light fitting by providing 32 mm dia GI Pipe bracket of lengh 1.05 mts, on pole incl. S&F sutable MS flat clamps with bolts, nuts etc. as required and painting |
| 43 | Supply, and fixing of 2 HP Centrifugal Monoblock pump Make- KSB, AGRIBLOC 20-5050 |
| 44 | Fixing only starters ( FOR motor control) on flat iron frame / angle iron frame on wall Direct on Line starter FOR motor (upto 5 HP) On flat iron frame ( FOR lower rating) |
| 45 | Supply Delivery and installation of ABC Powder type fire extinguishers (stored pressure) HSN code-84241000 conforming to IS:15683 and complete in all respect as per direction of EIC 06 Kg with ISI marked Mono Ammonium Phosphate base ABC power conforming to IS:14609 and pressurized with nitrogen gas. Suitable for operating between (-)30...C to (+)55...C. Fire rating -2A & 21B |
| 46 | Sub Total |
| 47 | GST 18% |
| 48 | CESS 1% Please Enable Macros to View BoQ information |